• 제목/요약/키워드: small-scale H

검색결과 423건 처리시간 0.026초

하이브리드 AMB를 포함한 초전도 플라이휠 에너지 저장장치의 실험평가 (Experimental Evaluation of Superconductor Flywheel Energy Storage System with Hybrid Type Active Magnetic Bearing)

  • 이정필;김한근;한상철
    • Progress in Superconductivity
    • /
    • 제13권3호
    • /
    • pp.195-202
    • /
    • 2012
  • In this paper, we designed Active Magnetic Bearing (AMB) for large scale Superconductor Flywheel Energy Storage System (SFESS) and PD controller for AMB. And we experimentally evaluated SFESS including hybrid type AMB. The radial AMB was designed to provide force slew rate that was sufficient for the unbalance disturbances at the maximum operating speed. The thrust AMB is a hybrid type where a permanent magnet carries the weight of the flywheel and an electromagnetic actuator generates the dynamic control force. We evaluated the design performance of the manufactured AMB through comparison of FEM analysis and the results of experimental force measurement. In order to obtain gains of PD controller and design a notch filter, the system identification was performed through measuring frequency response including dynamics for the AMBs, a power amp and a sensor using a sine swept test method after levitating the flywheel. Through measuring the current input of the AMBs and the orbit of a flywheel according to rotational speed, we verified excellent control performance of the AMBs with small amount current for the large scale SFESS.

태양광-풍력 복합발전시스템의 출력제어 특성에 관한 연구 (Realtime Monitoring system of Residential Photovoltaic system)

  • 이정일;서장수;윤필현;차인수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.933-937
    • /
    • 2003
  • The development of the solar and the wind power energy are necessary since the future alternative energies that have no pollution and no limitation are restricted. Currently power generation system of MW scale has been developed, but it still has a few faults with the weather condition. In order to solve these existing problems, combined generation system of photovoltaic(400w) and wind power generation system(400w) was suggested. It combines wind power and solar energy to have the supporting effect from each other However, since even combined generation system cannot always generate stable output with ever-changing weather condition, power compensation device that uses elastic energy of spiral spring to combined generation system was also added for the present study. In an experiment, when output of system gets lower than 12V(charging voltage), power was continuously supplied to load through the inverter by charging energy obtained from generating rotary energy of spiral spring operates in small scale generator

  • PDF

방사선 검사 관련 의료장비와 PACS 간의 연동을 위한 DICOM 및 Non-DICOM 인터페이스 방안 (Methods of DICOM and Non-DICOM Interfacing for various Radiological Equipments with PACS)

  • 김현철
    • 대한디지털의료영상학회논문지
    • /
    • 제6권1호
    • /
    • pp.51-64
    • /
    • 2003
  • This thesis describes the effective interfacing methods of PACS Modality based on the system installation andoperating experiences. PACS(Picture Archiving and Communication Systems) is a system for medical image archiving and communication using large storage device and high-speed network. The standard communication protocol of PACS is DICOM(Digital Imaging and Communication in Medicine) based on TCP/IP and point-to-point protocol. However, there are many Non-DICOM Modalities and DICOM Modalities having problems. First, we had interfaced almost modalities. Fuji CR, GE CT, MRI, Angio, Fluoro, Phillips Angio, Shimadzu Fluoro. Ultrasound PACS, with the main PACS in the Seoul S Hospital as large scale hospital. And we manipulated the intelligent image distribution and the CT. MRI Interfaces never experienced beforein the Anyang J Hospital and the Chungju C Hospital as mid or small scale hospital. Technically, we developed both the DICOM Interface and the Non-DICOM Interface. At the last, the DICOM Worklist and the DICOM Print Interface were implemented in the Seoul B Hospital, the Bucheon SJ Hospital and the Seoul K Hospital independently with PACS. The Oracle, Sybase and MS-SQL are used as database, and UNIX, Macintosh, MS Windows as operating systems. And the Visual C++ and UNIX C are the main programming tools. We have used UTP, coaxial and fiber optic cable under 10/100 mbps LAN for networking.

  • PDF

EMTDC용 1차 에너지계 모델(TGOV5) 개발 (The development of TGOV5 model representing a steam turbine and boiler for implementation into EMTDC)

  • 허진;김동준;윤재영;문영환;이진;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.282-285
    • /
    • 2001
  • In general, the PSS/E program based on RMS mathematical models is used for analyzing the steady state and transient stability phenomena of full-scale large power system. Whereas, the EMTDC program unlike PSS/E, studies the specific reduced small-scale power systems as a basis of instantaneous value mathematical models and used to analyze the Electro-Magnetic transient characteristics. The PSS/E provides various control models such as exciter, governor, PSS models and TGOV5 model but there are few control models in EMTDC. In this paper, we developed EMTDC model for TGOV5 of a steam turbine and boiler which represents governor action, main, reheat and low-pressure effects, including boiler effects. The EMTDC model is developed by examining PSS/E control block and using User Define Model(UDM) in addition to default.lib provided by EMTDC. We verify the correctness of developed TGOV5 model with PSS/E and EMTDC simulation results using Governor Step(GSTEP) method.

  • PDF

EMTDC용 조속기 모델 개발 및 GSTEP을 이용한 검증 (The development of Governor models for implementation into EMTDC and the verification of Governor models using GSTEP)

  • 허진;김동준;윤재영;문영환;이진;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.71-74
    • /
    • 2001
  • In general, the PSS/E program based on RMS mathematical models is used for analyzing the steady state and transient stability phenomena of full-scale large power system. Whereas, the EMTDC program unlike PSS/E, studies the specific reduced small-scale power systems as a basis of instantaneous value mathematical models and used to analyze the Electro-Magnetic transient characteristics. The PSS/E provides various control models such as exciter, governor and PSS models, But there are few control models in EMTDC. In this paper, we developed EMTDC models for governor which have been applied in KEPCO system. The EMTDC models are developed by examining PSS/E control block and using User Define Model in addition to default.lib provided by EMTDC. we verify the correctness of developed governor models with PSS/E and EMTDC simulation results using Governor Step(GSTEP) method.

  • PDF

ROSA/LSTF Test and RELAP5 Analyses on PWR Cold Leg Small-Break LOCA with Accident Management Measure and PKL Counterpart Test

  • Takeda, Takeshi;Ohtsu, Iwao
    • Nuclear Engineering and Technology
    • /
    • 제49권5호
    • /
    • pp.928-940
    • /
    • 2017
  • An experiment using the $Prim{\ddot{a}}rkreisl{\ddot{a}}ufe$ Versuchsanlage (PKL) was performed for the OECD/NEA PKL-3 Project as a counterpart to a previous test with the large-scale test facility (LSTF) on a cold leg smallbreak loss-of-coolant accident with an accident management (AM) measure in a pressurized water reactor. Concerning the AM measure, the rate of steam generator (SG) secondary-side depressurization was controlled to achieve a primary depressurization rate of 200 K/h as a common test condition; however, the onset timings of the SG depressurization were different from each other. In both tests, rapid recovery started in the core collapsed liquid level after loop seal clearing, which caused whole core quench. Some discrepancies appeared between the LSTF and PKL test results for the core collapsed liquid level, the cladding surface temperature, and the primary pressure. The RELAP5/MOD3.3 code predicted the overall trends of the major thermal-hydraulic responses observed in the LSTF test well, and indicated a remaining problem in the prediction of primary coolant distribution. Results of uncertainty analysis for the LSTF test clarified the influences of the combination of multiple uncertain parameters on peak cladding temperature within the defined uncertain ranges.

소규모 하수처리를 위한 파일럿 규모 이중슬러지 KNR® (Kwon's nutrient removal) 시스템의 영얌염류 제거성능 평가 (Evaluation of the Nutrient Removal Performance of the Pilot-scale KNR (Kwon's Nutrient Removal) System with Dual Sludge for Small Sewage Treatment)

  • 안진영;권중천;김윤학;정유훈;김두언;유선호;김병우
    • 청정기술
    • /
    • 제12권2호
    • /
    • pp.67-77
    • /
    • 2006
  • 본 연구에서 소규모 하수고도처리를 위한 이중슬러지(Dual sludge) $KNR^{(R)}$ (Kwon's nutrient removal) 시스템이 개발되었다. $KNR^{(R)}$ 시스템은 부유성장식 탈질미생물과 부착성장식 질산화미생물을 분리시킨 이중슬러지 공정으로 최초침전조, 혐기조, 무산소조, 농축조의 복합기능을 수행하는 UMBR (Upflow multi-layer bioreactor)과 펠렛형 담체가 충진된 호기성 담체조로 구성되어 있다. 소규모 하수처리시 본 개발공정의 안정성과 처리성능을 평가하기 위해 처리용량 $50m^3/d$ 규모의 파일럿 플랜트를 고도처리 공정으로 개선공사 중인 처리용량 $50m^3/d$ 규모의 실제 소규모 마을하수처리장에 적용하였다. UMBR과 담체조의 체류시간은 각각 4.7 h와 7.2h이었으며, 반응조 수온은 $18.1{\sim}28.1^{\circ}C$이었다. 유입 하수량과 유입수의 BOD/N의 변동폭이 컸음에도 불구하고 파일럿 플랜트는 안정된 처리성능을 보였다. 전체 실험기간 중 처리수의 $COD_{cr}$, $COD_{Mn}$, $BOD_5$, TN, TP의 평균 농도는 11.0 mg/L, 8.8 mg/L, 4.2 mg/L, 3.5 mg/L, 9.8 mg/L, 0.87/0.17 mg/L (poly aluminium chloride(PAC) 투입/미투입)이었으며, 제거율을 각각 95.3%, 87.6%, 96.3%, 96.5%, 68.2%, 55.4/90.3% 이었다. 잉여슬러지 발생량은 $A_2O$와 Bardenpho 등과 같은 단일슬러지를 이용하는 고도처리공정과 비교시 약 1.9~3.8배 낮은 $0.026kg-DS/m^3$ and 0.220 kg-DS/kg-BOD로 나타났다.

  • PDF

유해화학물질 대기확산 예측을 위한 RAMS 기상모델의 적용 및 평가 - CARIS의 바람장 모델 검증 (Application and First Evaluation of the Operational RAMS Model for the Dispersion Forecast of Hazardous Chemicals - Validation of the Operational Wind Field Generation System in CARIS)

  • 김철희;나진균;박철진;박진호;임차순;윤이;김민섭;박춘화;김용준
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.595-610
    • /
    • 2003
  • The statistical indexes such as RMSE (Root Mean Square Error), Mean Bias error, and IOA (Index of agreement) are used to evaluate 3 Dimensional wind and temperature fields predicted by operational meteorological model RAMS (Regional Atmospheric Meteorological System) implemented in CARIS (Chemical Accident Response Information System) for the dispersion forecast of hazardous chemicals in case of the chemical accidents in Korea. The operational atmospheric model, RAMS in CARIS are designed to use GDAPS, GTS, and AWS meteorological data obtained from KMA (Korean Meteorological Administration) for the generation of 3-dimensional initial meteorological fields. The predicted meteorological variables such as wind speed, wind direction, temperature, and precipitation amount, during 19 ∼ 23, August 2002, are extracted at the nearest grid point to the meteorological monitoring sites, and validated against the observations located over the Korean peninsula. The results show that Mean bias and Root Mean Square Error are 0.9 (m/s), 1.85 (m/s) for wind speed at 10 m above the ground, respectively, and 1.45 ($^{\circ}C$), 2.82 ($^{\circ}C$) for surface temperature. Of particular interest is the distribution of forecasting error predicted by RAMS with respect to the altitude; relatively smaller error is found in the near-surface atmosphere for wind and temperature fields, while it grows larger as the altitude increases. Overall, some of the overpredictions in comparisons with the observations are detected for wind and temperature fields, whereas relatively small errors are found in the near-surface atmosphere. This discrepancies are partly attributed to the oversimplified spacing of soil, soil contents and initial temperature fields, suggesting some improvement could probably be gained if the sub-grid scale nature of moisture and temperature fields was taken into account. However, IOA values for the wind field (0.62) as well as temperature field (0.78) is greater than the 'good' value criteria (> 0.5) implied by other studies. The good value of IOA along with relatively small wind field error in the near surface atmosphere implies that, on the basis of current meteorological data for initial fields, RAMS has good potentials to be used as a operational meteorological model in predicting the urban or local scale 3-dimensional wind fields for the dispersion forecast in association with hazardous chemical releases in Korea.

조합식(組合式) 정백(精白)시스템의 설계(設計) 및 작동인자(作動因子)에 관(關)한 연구(硏究)(I) -분풍(噴風) 연삭식(硏削式) 정미기(精米機)의 설계기준(設計基準) 설정(設定)- (A study on Design and Operational Factors of Rice Whitening Systems Consisting of Abrasive and Frictional whiteners -Design Criteria of Aerated-Abrasive Whitener-)

  • 이종환;노상하;고학균
    • Journal of Biosystems Engineering
    • /
    • 제12권1호
    • /
    • pp.20-30
    • /
    • 1987
  • Major rice grain losses both in quality and in quantity are incurred in the whitening process which is indispensable in the milling process. Rice whitening it performed by two different whitening actions known as abrasive and frictional. In Korea, abrasive-type whiteners equipped with a emery-stone roller have been adopted in the whitening system in large scale milling plants, but not in customary small scale. However, researches on this type whitener have rarely been conducted in Korea. This study was attempted to establish design criteria or a modified abrasive-type whitener which is aerated with blower. The factors considered in this study were three levels of feedscrew pitch (20, 27, 34 mm) and three levels of clearance(11, 13, 15 mm) between surfaces or emery-stone roller and screen and two levels of moisture content (14.5%, 15.7%, w.b.) of brown rice. Also, the effect of aeration on whitening performance was examined, and a system performance consisting of one pass in the aerated abrasive-type and two passes in the existing friction type was compared with the performance of the existing whitening system consisting of three passes in friction type only. The latter system is prevailed in customery small milling plants. The results of this study are summarized as follows. 1. The interactions between feed-screw pitch and chamber clearance of the aerated abrasive-type whitener had great effect on the performance of the machine. When the value of a nondimensional parameter, $C^2/(P{\cdot}d_p)$, expressing the relations between feed-screw pitch, P, and chamber clearance, C, ranged from 0.40 to 0.45, the performance of the aerated abrasive-type whitener was the best. 2. Aeration to the abrasive-type whitener gave positive effect on milled and head rice recoveries. 3. The whitening system involving the aerated abrasive-type whitener, which has appropriate feed-screw pitch and chamber clearance as described in item 1 above, produced more milled and head rice recoveries by about 1.5% and 2.0%, respectively, than the existing frictional whitening system. The former also consumed less electricity by about 10% (0.9KwH/1000kg).

  • PDF

Formation and Annealing Effect of Tolanethioacetate Self-Assembled Monolayers on Au(111)

  • Jeong, Young-Do;Han, Jin-Wook;Kim, Nak-Joong;Lee, Young-Il;Lee, Chang-Jin;Hara, Masahiko;Noh, Jaeg-Eun
    • Bulletin of the Korean Chemical Society
    • /
    • 제28권12호
    • /
    • pp.2445-2448
    • /
    • 2007
  • Self-assembled monolayers (SAMs) were formed by adsorption of thioacetyl-terminated tolanethioacetate (TTA) on Au(111) in a 0.5-mM ethanol solution after one day immersion at room temperature. Molecular-scale STM imaging revealed that the TTA SAMs were composed of two mixed phases; an ordered phase with small domains describing a ( × 2 )R30° structure and a disordered phase. Interestingly, after annealing the precovered TTA SAMs on Au(111) at 90 °C for 1 h, the small ordered domains grew unidirectionally, resulting in the formation of unique rod-like domains, which were assigned a ( × 2 )R7° structure. These results will be very useful in understanding the formation and thermal behavior of TTA SAMs on gold surfaces.