• Title/Summary/Keyword: small-displacement-movement

Search Result 37, Processing Time 0.022 seconds

Uncertainty Assessment of a Towed Underwater Stereoscopic PIV System (예인수조용 스테레오스코픽 입자영상유속계 시스템의 불확실성 해석)

  • Seo, Jeonghwa;Seol, Dong Myung;Han, Bum Woo;Yoo, Geuksang;Lim, Tae Gu;Park, Seong Taek;Rhee, Shin Hyung
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.51 no.4
    • /
    • pp.311-320
    • /
    • 2014
  • Test uncertainty of a towed underwater Stereoscopic Particle Image Velocimetry (SPIV) system was assessed in a towing tank. To estimate the systematic error and random error of mean velocity and turbulence properties measurement, velocity field of uniform flow was measured. Total uncertainty of the axial component of mean velocity was 1.45% of the uniform flow speed and total uncertainty of turbulence properties was 3.03%. Besides, variation of particle displacement was applied to identify the change of error distribution. In results for variation of particle displacement, the error rapidly increases with particle movement under one pixel. In addition, a nominal wake of a model ship was measured and compared with existing experimental data by five-hole Pitot tubes, Pitot-static tube, and hot wire anemometer. For mean velocity, small local vortex was identified with high spatial resolution of SPIV, but has serious disagreement in local maxima of turbulence properties due to limited sampling rate.

A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE (총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구)

  • Kwon, Kung-Rock;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.36 no.2
    • /
    • pp.389-423
    • /
    • 1998
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography (Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as fellows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely(p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge. the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

A STUDY ON MASTICATORY PERFORMANCE AND FUNCTION BY POSTERIOR OCCLUSAL SCHEMES IN COMPLETE DENTURE (총의치의 교합면 형태에 따른 저작 효율 및 기능에 관한 연구)

  • Kwon, Kung-Rock;Park, Nam-Soo;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.3
    • /
    • pp.539-573
    • /
    • 1996
  • This investigation was designed to determine the effectiveness of the posterior occlusal schemes on masticatory activity during mastication in complete denture. Twelve edentulous subjects were selected for this study. All subjects had no past history and no functional abnormality on masticatory system and TMjoint. And, they had residual ridge of favorable morphology, firm mucosa and Class I skeletal jaw relationship, Twelve experimental denture with interchangeable occlusions(0-degree teeth, 30-degree teeth, Levin teeth and S-A teeth) were constructed for this study. The masticatory performance was analyzed by means of standard sieve(10, 16, 20, 30sieve), and the electrical activity from selected muscles(Temporalis and Masseter muscle) was recorded simultaneously with electromyography(Bio-Pak system) as the subject masticated test foods (rice, peanut and gum) with four different occlusal schemes. Mandibular movement was, also, measured with Sirognathography(Bio-Pak system). These recordings were performed in immediately, after 1 week and after 2 weeks of insertion of complete denture. The results were as follows; 1. The average masticatory performance of 0-degree artificial teeth was higher than any other artificial teeth. 2. Masticatory performance in denture wearer was affected preferentially by food and artificial occlusal schemes. 3. During chewing, there was a statistical difference of EMG activity between masseter and temporal muscle(p<0.01). Especially, EMG activity of working masticatory muscle was highly affected by food rather than by artificial occlusal schemes. 4. In denture wearer, the velocity of opening was not affected by food, whereas, the velocity of closing was faster in soft food chewing than in hard food chewing, and the amount of vertical displacement was grater in chewing of soft and large bolus than in chewing of hard and small bolus. However, the amount of lateral displacement showed conversely (p<0.05). 5. It was considered that masticatory performance in denture wearer is not affected by the condition of residual ridge, the history of denture wear, the preference, the adaptation to artificial teeth and the total mesiodistal length of artificial posterior teeth.

  • PDF

Kinematic Analysis of Secondary School Golf Player's Putting Stroke Motion (중등학생 골프선수의 퍼팅 스트로크 동작에 대한 운동학적 분석)

  • Ko, Jae-Yeon;Oh, Cheong-Hwan
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.4
    • /
    • pp.447-455
    • /
    • 2010
  • The objective of this study was to analyze the difference in kinematic variables for successful and unsuccessful golf putting strokes. The study population included 8 male secondary school golf players who had played golf for over 3 years and whose handicap was 4 or lower. A hole was made on a 5-m-long artificial flat mat for practice, and an environment similar to that of a real green was created. The participants' motions were analyzed through 3D image analysis, and the difference in kinematic variables for successful and unsuccessful putting strokes in the same direction was determined. Data analysis revealed the following findings: The time spent for a segment of putting was the greatest for the backswing segment for both successful and unsuccessful strokes. During address and impact, the both changed to a larger extent. For successful putting strokes, the change in the elbow angle during the downswing was greater for the right elbow than for the left elbow. For both successful and unsuccessful putting strokes, the left shoulder angle increased during the segment from address to the turning point and decreased during the segment from the turning point to impact. In contrast, the right shoulder angle significantly differed between successful and unsuccessful putting strokes only during address. During successful and unsuccessful motions, the swing was executed with the moving displacement of the X-axis of the club head maintained almost constant along a straight light without back and forth movement. In the backswing segment, moving displacement of the Y- and Z-axes was greater in successful strokes than in unsuccessful strokes; however, this difference was very small for the Y-axis. The velocity of the club head for successful and unsuccessful motions significantly differed during address and at the turning point. The highest velocity of the ball was greater for successful than for unsuccessful putting strokes.

A 3-D finite element analysis on the mandibular movement pattern and stress distribution during symphyseal widening (하악 이부확장 시 하악골 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Lee, Do-Hoon;Hong, Hyun-Sil;Chae, Jong-Moon;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.38 no.1
    • /
    • pp.13-30
    • /
    • 2008
  • Objective: The objective of this study was to evaluate the displacement pattern and the stress distribution of the finite element model 3-D visualization during symphyseal widening according to the osteotomy position, osteotomy type, and distraction device. Methods: The kinds of distraction devices used were tooth-borne type, hybrid type, bone-borne type and tooth-borne type $30^{\circ}$ angulated, and the kinds of osteotomy design were vertical osteotomy line between the central incisors and step osteotomy line through the symphysis. Results: All reference points of the mandible including the condyles were displaced laterally irrespective of the osteotomy position, osteotomy method and distraction device. The anteroposterior or vertical displacements showed small differences between the groups. The widening pattern of the osteotomy line in the tooth-borne type of device was v shaped, and that of bone-borne type was a reverse v shape. However, the pattern in the hybrid type was parallel. The lateral displacement of the mandibular angle by the bone-borne device was more remarkable than the other types of devices. The displacement by the $30^{\circ}$ angulated tooth-borne type was different between the left and right sides in both the transverse and anteroposterior aspects. Conclusion: The design of the distraction devices and osteotomy line can influence the displacement pattern and the stress distribution during mandibular symphyseal distraction osteogenesis procedures.

Centrifuge modelling of pile-soil interaction in liquefiable slopes

  • Haigh, Stuart K.;Gopal Madabhushi, S.P.
    • Geomechanics and Engineering
    • /
    • v.3 no.1
    • /
    • pp.1-16
    • /
    • 2011
  • Piles passing through sloping liquefiable deposits are prone to lateral loading if these deposits liquefy and flow during earthquakes. These lateral loads caused by the relative soil-pile movement will induce bending in the piles and may result in failure of the piles or excessive pile-head displacement. Whilst the weak nature of the flowing liquefied soil would suggest that only small loads would be exerted on the piles, it is known from case histories that piles do fail owing to the influence of laterally spreading soils. It will be shown, based on dynamic centrifuge test data, that dilatant behaviour of soil close to the pile is the major cause of these considerable transient lateral loads which are transferred to the pile. This paper reports the results of geotechnical centrifuge tests in which models of gently sloping liquefiable sand with pile foundations passing through them were subjected to earthquake excitation. The soil close to the pile was instrumented with pore-pressure transducers and contact stress cells in order to monitor the interaction between soil and pile and to track the soil stress state both upslope and downslope of the pile. The presence of instrumentation measuring pore-pressure and lateral stress close to the pile in the research described in this paper gives the opportunity to better study the soil stress state close to the pile and to compare the loads measured as being applied to the piles by the laterally spreading soils with those suggested by the JRA design code. This test data shows that lateral stresses much greater than one might expect from calculations based on the residual strength of liquefied soil may be applied to piles in flowing liquefied slopes owing to the dilative behaviour of the liquefied soil. It is shown at least for the particular geometry studied that the current JRA design code can be un-conservative by a factor of three for these dilation-affected transient lateral loads.

Tapered Joint Design for Power Transmission of MW-grade Wind Turbine (MW급 풍력발전기 동력전달용 테이퍼 연결장치 설계에 관한 연구)

  • Kang, JongHun;Bae, JunWoo;On, Hanyong;Kwon, Yongchul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.11
    • /
    • pp.1183-1189
    • /
    • 2015
  • This study focuses on the design of the tapered joints of a wind power turbine. The main variables of the tapered joint are the transmitted torque, shaft diameter, contact area of the tapered ring, and tightening torque of the bolts, which applies a compressive pressure from the hub to the shaft. The stress distribution of the taper fit was calculated under axisymmetric plane strain conditions because of the small taper angle. The axial displacement of the clamp can be calculated from the radial elastic deformation and the taper angle. The stress field of each ring is obtained from the cylinder stress equation. To verify the accuracy of the calculation, finite element (FE) analysis was performed, and the results of the calculation and FE analysis were compared. The hoop stress of the tapered surface showed a discrepancy of approximately 10, but the trends of the stress distributions of each component and the relative movement obtained by FE analysis were in good agreement with the analytical calculation results.

Schwannoma Originating from Infraorbital Nerve (안와하신경에서 기원한 신경초종의 치험례)

  • Ha, Won;Lee, Ji Won;Choi, Jae Il;Yang, Wan Suk;Kim, Sun Young
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.61-64
    • /
    • 2013
  • Schwannomas are well-differentiated solitary benign tumors that originate from the schwann cells of the nerve sheath. They can readily occur in the head and neck regions, but the schwannoma originating from the infraorbital nerve is extremely rare and usually painless, slow-growing, and without specific symptoms. The author experienced a rare case of infraorbital schwannoma, which was completely removed through the intraoral approach. A 20-year-old woman was admitted to our hospital for a painless, solid and circular mass located on the right infraorbital region. The eyeball movement and visual field were normal. There was no globe displacement or proptosis. Preoperative computed tomography demonstrated $13{\times}10{\times}5mm$-sized soft tissue mass. On March 2011, the mass was removed through an intraoral approach. On histopathological examination, the gross specimen consisted of a smooth, well-encapsulated and light yellowish solid mass, measuring $12{\times}7{\times}5mm$. Microscopically, it presented a typical manifestation of schwannoma with Antoni A area with Verocay body, and Antoni B area on H&E stain. The result of the immunohistochemical staining was positive for the S-100 protein. The patient had hypoesthesia of the nasal septum and vestibule in the postoperative period, and this finding confirmed that the internal nasal branch of infraorbital nerve was the nerve in which the schwannoma originated. Infraorbital schwannomas are very rare and must be included in the differential diagnosis of the orbital masses inferior to the eyeball. In the case of early diagnosis, the small-sized infraorbital schwannomas can be completely removed without any scar through an intraoral approach.

Diffusion-hydraulic properties of grouting geological rough fractures with power-law slurry

  • Mu, Wenqiang;Li, Lianchong;Liu, Xige;Zhang, Liaoyuan;Zhang, Zilin;Huang, Bo;Chen, Yong
    • Geomechanics and Engineering
    • /
    • v.21 no.4
    • /
    • pp.357-369
    • /
    • 2020
  • Different from the conventional planar fracture and simplified Newton model, for power-law slurries with a lower water-cement ratio commonly used in grouting engineering, flow model in geological rough fractures is built based on ten standard profiles from Barton (1977) in this study. The numerical algorithm is validated by experimental results. The flow mechanism, grout superiority, and water plugging of pseudo plastic slurry are revealed. The representations of hydraulic grouting properties for JRCs are obtained. The results show that effective plugging is based on the mechanical mechanisms of the fluctuant structural surface and higher viscosity at the middle of the fissure. The formulas of grouting parameters are always variable with the roughness and shear movement, which play a key role in grouting. The roughness can only be neglected after reaching a threshold. Grouting pressure increases with increasing roughness and has variable responses for different apertures within standard profiles. The whole process can be divided into three stationary zones and three transition zones, and there is a mutation region (10 < JRCs < 14) in smaller geological fractures. The fitting equations of different JRCs are obtained of power-law models satisfying the condition of -2 < coefficient < 0. The effects of small apertures and moderate to larger roughness (JRCs > 10.8) on the permeability of surfaces cannot be underestimated. The determination of grouting parameters depends on the slurry groutability in terms of its weakest link with discontinuous streamlines. For grouting water plugging, the water-cement ratio, grouting pressure and grouting additives should be determined by combining the flow conditions and the apparent widths of the main fracture and rough surface. This study provides a calculation method of grouting parameters for variable cement-based slurries. And the findings can help for better understanding of fluid flow and diffusion in geological fractures.

A FEM comparison study about the force, displacement and initial stress distribution on the maxillary first molars by the application of Asymmetric Head-Gears with the different traction forces (Asymmetric Head-Gear의 견인력의 차이에 따른 상악 제 1 대구치에 나타나는 힘과 변위 및 초기 응력분포에 관한 유한요소법적 비교 연구)

  • Cha, Kyung-Suk
    • The korean journal of orthodontics
    • /
    • v.31 no.3 s.86
    • /
    • pp.311-323
    • /
    • 2001
  • One of the various mechanics used to treat unilateral Class II malocclusion is head gear with asymmetric face bow. We made the finite element models of unilateral Class II maxillary dental arch and power arm asymmetric face bow. We designed this experiment to observe stress distribution of periodontal ligament, reaction force, and displacement and to understand force system, so to predict the therapeutic effect. On the basis of computerized tomograph of maxillary dental arch of 25 years old male with normal occlusion without extraction and orthodontic treatment history, we made finite element models of maxillary dental arch and periodontal ligament. Then we modified that model to unilateral maxillary Class II malocclusion model of which maxillary left molar displaced mesially. Also, We made finite element model of asymmetric face bow of which right outer bow shorter than left by 25mm(RMO, Penta-FormTM/Medium size, 0.045 inch iner bow, 0.072 inch outer bow). After that, retraction force of 250g, 300b, 350g were applied to maxillary first molar. We concluded as follow. 1. The Net force that both maxillary first molars were received increased as the retraction force increased. Mesially positioned tooth received more force than normally positioned tooth. But, both tooth were received distal force, so distal movement occured. 2. Both tooth received buccal lateral force. In analysis of force element, as the retraction force were increased, force of X-axis at mesially positioned tooth decreased, and force of X-axis at normally positioned tooth increased. so lateral force component moved to the side received less force from more force. 3. There were rotation, tipping with distal movement in maxillary first molar. As retraction force were increased, rotation and tipping also increased. More tipping and rotation occured at the side received more force, that is, mesially positioned tooth. Though it Is small change, displacement of same pattern occur in normally positioned tooth

  • PDF