Uranium in Drinking Water of Kyungpook Area in Korea (경북지역의 먹는 물에서 우라늄 검출 특성)

  • Lee, Hea-Geun;Cha, Sang-Deok;Kim, JeongJin;Kim, Young-Hun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.27 no.4
    • /
    • pp.235-242
    • /
    • 2014
  • Uranium can be released into the water environment from natural sources and human activities. The natural source of uranium is dominant in the Korean soil and groundwater environments. Uranium has both of radioactive and chemical toxic properties. Therefore, a drinking water contaminated with uranium has a high health risk. This study was conducted to determine the uranium concentration of water systems including small village drinking water system, groundwater for drinking water purpose, spring water, groundwater monitoring well, and emergency water suppling system. The uranium concentration was compared with domestic and other countries' standard. The contamination level was also evaluated on the basis of geological characteristics of the area. Among total 803 samples, 6 exceeded the Korean standard, $30{\mu}g/{\ell}$ and this was about 0.7% of the total sample. On the basis of geology, uranium concentration appeared to be increased in order of biotite granodiorite > biotite granite > gneissoid granite. The highest level of uranium was 12.4 in average.

A development of integrated water-quality measurement system (통합 수질계측 시스템 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.8 no.3
    • /
    • pp.211-216
    • /
    • 2007
  • The quality of tap water on the whole water-supply system, from a large filtration plant to a private faucet, has to be guaranteed the standards of drinking water. At this point in time, however, the supply process of the tap water has not been monitored and managed scientifically. The piped water, especially the most small-scale reservoirs(underground or overhead type) are always exposed to various contaminations and impurities. Recently monitoring systems of water-quality were spread on some large filtration plants or distributing reservoirs. In particular, the water quality monitoring method using the internet is adopted into some local government whose inhabitants can check up the water quality anytime and anywhere. The construction of this system that has to apply a large scale needs, and has a limitation on the small water-supply system, such as apartments, public facilities and small-scale underground or overhead reservoirs. In this work, we suggest the integration system of individual water-quality sensor modules that have a low price. By using the developed integration system and monitoring program operated on the internet, the system managers of reservoirs can monitor and manage water-quality characteristic values of drinking water in online. Since the proposed system was modularized, the system can be applied easily into various reservoirs with a low cost and regardless of its scale, small or large.

  • PDF

A development of submerged type multiprobe water-quality measuring instrument and remote monitoring system (침지형 다항목 수질계측기 및 원격 모니터링 시스템 개발)

  • Yang, Keun-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.3
    • /
    • pp.207-213
    • /
    • 2009
  • The quality of tap water on the whole water-supply system, from a large filtration plant to a private faucet, has to be guaranteed the standards of drinking water. At this point in time, however, the supply process of the tap water has not been monitored and managed scientifically. The piped water, especially the most small-scale reservoirs(underground or overhead type) are always exposed to various contaminations and impurities. Recently monitoring systems of water-quality were spread on some large filtration plants or distributing reservoirs. In particular, the water quality monitoring method using the internet is adopted into some local government whose inhabitants can check up the water quality anytime and anywhere. The construction of this system that has to apply a large scale needs, and has a limitation on the small water-supply system, such as apartments, public facilities and small-scale underground or overhead reservoirs. In this work, we suggest the integration system of individual water-quality sensor modules that have a low price. By using the developed integration system and online monitoring program operated on the internet, the system managers of reservoirs can monitor and manage water-quality characteristic values of drinking water in online. Since the proposed system was modularized, the system can be applied easily into various reservoirs with a low cost and regardless of its scale, small or large.

  • PDF

Design of Micro Water Supply System Using Solar Energy

  • Sharma, Ekisha;Khatiwada, Nawa Raj;Ghimire, Anish
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.8-17
    • /
    • 2019
  • Solar pumps, for water lift systems, is becoming popular in rural areas for supplying drinking water in dry seasons when its need is elevated. The development in technology has also made solar pumps readily available and cheap which has increased its demands. So, for scattered settlements having a limited budget for operation and maintenance costs, solar pump is preferred over grid connected electrical pumping systems. This primary objective of the study was to design a solar photovoltaic pumping drinking water supply system for a small health post which is about 45 km east from Kathmandu, the capital city of Nepal. The study also compared and verified the final design with the system's existing design prepared by a development agency. The water source for this study was a confined aquifer 115m below the surface. The water demand was calculated to be 11m3 per day. A 1500 kPa submersible pump attached to a motor was selected and installed. Along with that twelve solar panels, reservoir, transmission main and distribution main was designed. The outcomes conclude solar photovoltaic pumping water supply systems to be cost-effective with an estimated cost of only USD 0.84 million per MLD. Solar pumps require low maintenance and operation costs and its repairs can quickly be done by the local people. The study also shows that solar technology produces no sound, needs no fuel making it environmentally friendly.

Design Methods and Capacity Analysis of Artificial Circulation Systems in Korean Reservoirs (우리 나라 저수지의 수중 폭기 장치의 설계 방법 및 용량 분석)

  • Seo, Dong-Il;Seog, Kwan-Soo;Lee, Byung-Doo;Jeong, Sang-Gi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.3
    • /
    • pp.366-376
    • /
    • 2004
  • Use of artificial circulation system has become popular in Korean reservoirs to control algal blooms and subsequent color, taste and odor problems in drinking water. It was found that the most of aeration system in Korean reservoirs are under-designed compared to existing installations in US and Australia. This was especially true for larger reservoirs greater than $5{\times}10^7m^3$ in volume since it is common to install the system in the vicinity of intake areas only. Consequently, successful cases of artificial circulation systems operations are limited to few small reservoirs less than $1{\times}10^7m^3$. It is suggested that the design methods need to be developed considering physical characteristics and water quality kinetics inside of reservoirs. Also operation methods of artificial circulation systems need to be established considering the water quality dynamics, stratification and morphological characteristics of reservoirs. Finally, it is suggested to maintain comprehensive and long term monitoring programs to validate the application of artificial circulation system in reservoirs.

A Study on the Distribution Characteristics of Bromide and Bromate in Drinking Water in Northern Gyeonggi Area (경기북부지역 먹는 물 중 브롬이온 및 브롬산염의 분포특성에 관한 연구)

  • Jung, Jong-Pil;Choi, Si-Rim;Ryu, Hyeung-Rial;Park, Gyoung-Su;Song, Hee-Il;Lee, Hyun-Jin;Jo, Mi-Hyun;Oh, Jo-Gyo;Yoon, Mi-Hye
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.244-249
    • /
    • 2018
  • Objectives: The purpose of this study was the investigation of bromide and bromate in drinking water of water supply plants, mineral springs and small water supply system located in northern area of Gyeonggi province. Methods: Analytical method was based on EPA 326.0 to use Postcolumn reaction (PCR). The instrument was 887 professional UV/VIS detector IC manufactured in Metrohm. Results: Bromate was detected at $0.5{\sim}2.4{\mu}g/L$ in tap water from 5 water supply plants. These plants were used as disinfection method for sodium hypochlorite and on-site chlorine that causes generate bromate as a by products even if not used ozone. Conclusions: The bromate was detected up to $2.5{\mu}g/Lin$ drinking water in northern Gyeonggi area that showed within $10{\mu}g/L$ for standard of tap water. However, the continuous monitoring of bromate is necessary in drinking water.

Numerical Analysis of Mixing Flow in a Small-Scale Water Supply System (간이상수도에서의 혼합유동에 대한 수치해석)

  • Yoo, Young-Hyun;Ki, Hyun;Choi, Jong-Wook;Kim, Sung-Cho;Kim, Yong-Seon;Lee, Yong-Ho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.6
    • /
    • pp.460-466
    • /
    • 2009
  • The mixing method of water and chemicals is significant in a small-scale water supply system because drinking water should be supplied with a certain quantity of remaining chemicals maintained. In the present study, the concentration distribution and the mixing index were obtained from four models, which were to find out the optimal mixing method of water and chemicals. The two models brought the good mixing effects out of the four, one for providing chemicals from the center of water supply pipe and the other for setting up the semicircle block at the downstream of the chemicals-providing pipe. As a result, the mixing effect was found out to be increased due to the diffusion and the disturbance of flows. In conclusion, these numerical results are expected to contribute to designing the optimal mixing system.

A study on the Thermal Design of the Compact Type Small Fresh Water Generator (콤팩트형 소형 담수화장치의 열설계에 관한 연구)

  • 김성규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.3
    • /
    • pp.311-319
    • /
    • 1999
  • In Korea accelerated industry development and urbanization during the last three decades have led serious water pollution problems in many parts of the nation. Especially in the regions of west and south coast have low fresh water in the dry season of spring and summer. In the place isolated from land it is important to secure the fresh water for drinking and general service. This study is concerned on the thermal system design to develop low-pressure evaporation type fresh water gen-erator of capacity 1 ton/day using the heat source of non-operating boiler in the season of spring and summer. The results obtained from this study are as follows. the water quantitieds generated from experi-mental evaporator showed good coincidence with the calculated values. The maximum production quantity was 1.38ton/day at pressure 40mmHg abs. and temperature $80^{\circ}C$.

  • PDF

A study on health risk assessment for small-scale water works in Gyeongnam province from 2014 to 2016 (2014~2016년 동안 경남지역 소규모 급수시설에 대한 건강 위해성 평가 연구)

  • Park, Ju-Won;Son, Song-Ee;Lee, Hu-Jang
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.227-237
    • /
    • 2018
  • Objectives: This study was investigated the characteristics of small-scale water works (SWW) in Gyeongnam area and conduct a health risk assessment of water-quality inspection items unfitted for water-quality standards (WQS). Methods: The characteristics of SWW in Gyeongnam province were analyzed using the data of SWW in the last three years (2014~2016) published in National Waterworks Information System. In addition, the health risk assessment for inspection items unfitted for WQS was carried out in four steps: hazard identification, dose-response assessment, exposure assessment, and risk characterization. Results: The total number of SWW in Gyeongnam area was gradually decreased from 2014 to 2016. In addition, drinking water sources of SWW were in the order of ground water, valley water, spring water, surface water, and river-bed water. The number of points unfitted for WQS in SWW by year was 22, 45, and 18 in 2014, 2015, and 2016, respectively, and a total of 112 points were found to unfit for WQS in SWW during 2014~2016. The hazard quotient (HQ) for fluoride, nitrate nitrogen, boron in the unfitted points for WQS was more than 1.0, and the mean values for turbidity and color in points unfitted for WQS were 2.38 nephelometric turbidity unit and 16.25 color unit, respectively. Conclusions: The HQ for fluorine, nitrate nitrogen and boron was more than 1.0 in points unfitted for WQS among SWW in Gyeongnam area, and the turbidity and the color degree exceeded WQS, which mean that there is a possibility of harmful impacts on the human health.

Study of Sewage Treatment using Multi-soil-layering System (다단토양층을 이용한 하수처리에 관한 연구)

  • Son, Dae-Hee;Chung, Yun-Chul;Shin, Jeong-Hoon;Jung, Jin-Young;Ahn, Dae-Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.20 no.3
    • /
    • pp.215-222
    • /
    • 2004
  • The sewages produced from small villages, rural community, drinking water reservation area and park which doesn't have sewage piping system can be caused a serious water pollution at the restricted areas. The objective of this research was to suggest an economical and effective sewage treatment method by investigating the removal of the organics, nitrogen, and phosphorus in the multi-soil-layering reactor. Soil, natural zeolite, and iron slag were used as a supporting media of multi-soil-layering in this research. The purpose of natural zeolite addition was to maintain the consistent ammonium exchange capacity by providing a sequential environment, and that of iron slag addition was to remove phosphorus by adsorption. Continuous experiment of lab-scale single-soil-layering (S-1), multi-soil-layering (S-2), and mixed-soil-layering (S-3) methods were studied to compare and optimize three different types of the reactors. The organic removal efficiencies showed more than 90% in all three reactors. While S-1 and S-3 reactors showed about T-N removal of 31%, 45%, respectively, the average T-N removal efficiency of the S-2 reactor represented an 87%. In conclusion, that results suggest that the multi-soil-layering reactor could be effectively utilized as a plant for treatment of small village sewage.