• Title/Summary/Keyword: small chamber method

Search Result 158, Processing Time 0.021 seconds

A Study on the Emission Characteristics and Prediction of VOCs (Volatile Organic Compounds) using Small Chamber Method (소형챔버법을 이용한 휘발성유기화합물(VOCs) 방출특성 및 예측에 관한 연구)

  • Pang, Seung-Ki;Sohn, Jang-Yeul;Lee, Kwang-Ho
    • KIEAE Journal
    • /
    • v.4 no.4
    • /
    • pp.11-18
    • /
    • 2004
  • In this study, the measurement system was developed for the measurement of pollutants from building materials, and specimens were made with concrete, gypsum board, mortar and wall paper. Characteristics of VOCs and TVOC concentration and Emission Factor as a function of time were assessed, and the conclusion was drawn as follows. (1) From predicting TVOC concentration decrease of specimen 7 with the wall paper attached to the concrete, the graph may become linear by converting the value of y-axis into the log function, and the prediction equation can be expressed as $y=34906{\ast}e^{-0.0093{\ast}time}$. Moreover, chi-square value was 0.83 which is relatively high value, indicating that TVOC concentration can be properly predicted if the same materials are used indoors. (2) From predicting VOCs Emission Factor decrease of specimen 7, the prediction equation can be expressed as $EF=15111{\ast}e^{-0.0093{\ast}time}$, and chi-square value was 0.83. (3) From predicting TVOC concentration decrease of specimen 7, prediction equation can be considered to be $y=254323{\ast}(1-e^{-0.1046{\ast}time})$, and chi-square was 0.994 which is significantly high value, indicating that indoor TVOC concentration can be properly predicted if the same materials are used indoors. Furthermore, the prediction of concentration decrease using cumulative value of hourly measured concentration is considered to be more accurate than that using just hourly measured value directly. (4) From predicting Emission Factor decrease with cumulative hourly data of Emission Factor, chi-square appeared to be higher than that by just using hourly data of Emission Factor directly. Therefore, the prediction of Emission Factor with cumulative hourly data can provide more reliable prediction equation than the case by using just hourly concentration directly.

Insights Of Air Pollutant Emission From Construction Sealant (건축용 실란트 오염물질 방출량 기준에 대한 고찰)

  • Seo, Yeonwon;Jung, Jinyoung;Bae, Keesun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.226-227
    • /
    • 2014
  • This study is intended for the review of the standards related with the released contaminants from building materials used in the building room. Because currently being used industry standard and test method for the emissions of air pollutant are ambiguous so the new enactment and revision of the test methods and standards need to be addressed to match the actual situation in the construction industry. Based on actual evaluation for seveal sealants used in the job site, this study will present a direction for the revision and new enactment of standards and test method appropriately.

  • PDF

Analysis of a gas-particle direct-contact heat exchanger with two-phase radiation effect (복사효과를 고려한 기체-입자 직접접촉식 열교환기 해석)

  • Park, Jae-Hyeon;Baek, Seung-Uk;Gwan, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.542-550
    • /
    • 1998
  • A direct contact heat exchanger using particle-suspended gas as a heat transfer medium is analyzed with an extended emphasis on the radiation, i. e., considering the radiation by both gas and particles. While the Runge-Kutta method is used for a numerical analysis of the momentum and energy equations, the finite volume method is utilized to solve the radiative transfer equation. Present study shows a notable effect by the gas radiation in addition to the particle radiation, especially when changing the chamber length as well as the gas and particle mass flow rate. When the gas and particle mass flow rate is raised, the gas temperature in the particle heater still increases as the gas absorption coefficient increases, which is different from the results for the small scale heat exchanger.

A Study on the Measurement of Individual Spray Cone Angle from Gasoline Direct Injection Injector using Spray Pattern Analysis (분무패턴 분석을 이용한 가솔린 직접 분사식 인젝터의 개별 분무플럼 분무각 측정 방법에 대한 연구)

  • Park, Jeonghyun;Cho, Hanbin;Park, Suhan
    • Journal of ILASS-Korea
    • /
    • v.25 no.2
    • /
    • pp.51-59
    • /
    • 2020
  • The purpose of this study is to propose and compare methods for measuring individual spray cone angles using spray cross-section images. In direct injection gasoline engines, it was believed that the distribution of air-fuel mixture in the combustion chamber directly affected combustion performance and emission formation. However, since gasoline direct injection (GDI) injectors have a small injection angle, interference between individual spray plumes occurs. Therefore, GDI injectors have only measured the spray angle of the entire spray. To overcome these limitations, three methods of indirectly measuring the spray cone angles of individual spray plume were presented and compared by forming sheet beams using Nd:YAG laser and acquiring spray cross-section images. Each method currently has advantages and disadvantages, and research to apply the method suitable for various GDI injectors needs to be continued.

Integration of Headspace Solid Phase Micro-Extraction with Gas Chromatography for Quantitative Analysis of Formaldehyde

  • Lo, Kong Mun;Yung, Yen Li
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.1
    • /
    • pp.139-142
    • /
    • 2013
  • A study was carried out to evaluate the solid phase micro-extraction (SPME) for formaldehyde emission analysis of uncoated plywood. In SPME, formaldehyde was on-fiber derivatized through headspace extraction and analyzed by gas chromatography coupled with mass spectrometry (GC/MS). The SPME was compared with desiccators (DC-JAS 233), small-scale chamber (SSC-ASTM D6007) and liquid-liquid extraction (LLE-EPA 556) methods which were performed in accordance with their respective standards. Compared to SSC (RSD 4.3%) and LLE (RSD 5.0%), the SPME method showed better repeatability (RSD 1.8%) and not much difference from DC (RSD 1.4%). The SPME has proven to be highly precise (at 95% confidence level) with better recovery (REC 102%). Validation of the SPME method for formaldehyde quantitative analysis was evidenced. In addition, the SPME by air sampling directly from plywood specimens (SPME-W) correlated best with DC ($r^2$ = 0.983), followed by LLE ($r^2$ = 0.950) and SSC ($r^2$ = 0.935).

An Analysis of Pile Foundation Load Transfer for Lightweight Pavement System in Clay Soil using Lab Chamber Test (모형챔버시험을 이용한 점성토 지반에 설치된 경량포장체용 기초의 하중전달 특성)

  • Lee, Kwan-Ho;Shin, Kwang-Ho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.36 no.3
    • /
    • pp.545-550
    • /
    • 2016
  • The main purpose of this study is to analyze and evaluate the feasibility of ligthweight pavement system with pile foundation on soft soil by laboratory small chamber test. In order to verify the stability of lightweight pavement system, the 1/30 scaled downed model system was tested at lab. The soft soil condition was simulated and group piles for skin friction resistance were used. Within the limited lab test, the settlements of pavement system were 0.86 mm for Case A, 0.70 mm for Case B, and 0.50 mm for Case C. The converted maximum settlement differential settlement were 25.8 mm and 10.8 mm. These values meet the inside of specification of Bridge Design Guide in Korea. The use of lightweight pavement systems on soft soils could be an alternative construction method on soft soils to reduce the challenges of conventional design and constructions.

Design of Sample Chamber and Implementation of a 4-Channel Electrolyte Analyzer using ISFET Microsensor (ISFET 마이크로센서용 샘플챔버 설계 및 4채널 전해질 분석기의 구현)

  • Bae, Sang-Kon;Lee, Ho-Shin;Won, Chul-Ho;Chae, Seung-Pyo;Kim, Chang-Soo;Cho, Byung-Wook;Sohn, Byung-Ki;Kim, Myoung-Nam;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.4
    • /
    • pp.307-315
    • /
    • 1997
  • In this paper, a sample chamber which provide easy replacement of ISFET sensor and consume only small sample volume for electrolyte analysis is designed and a 4-channel electrolyte analyzer employing 2-point calibration method is implemented. In addition, we proposed sample loading detection circuit for minimizing sample and calibration solutions and implemented it. Developed electrolyte analyzer consists of control system part and flow system part. For the effective control of the developed hardware, system software is developed as three individual routines ; measuring routine, calibration routine and washing routine.

  • PDF

Performance Evaluation of Ethanol Blended Hydrogen Peroxide Thrusters (에탄올 블렌딩한 과산화수소 추력기의 성능평가)

  • Lee, Jeong-Sub;Kwon, Se-Jin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.100-103
    • /
    • 2012
  • The blending method that is an addition of small quantity of fuel was used to increase the performance of green propellant thruster. 90 wt.% hydrogen peroxide as a green propellant was selected, and ethanol was used as a blended fuel. The o/f ratio was chosen as 50 which has higher theoretical performance than 98 wt.% hydrogen peroxide. The chamber temperature of blended hydrogen peroxide was higher than adiabatic chamber temperature of hydrogen peroxide. Therefore, performance can be improved by ethanol blending. Several catalyst and its support were compared to find appropriate catalyst for decomposition and combustion of ethanol blended hydrogen peroxide. As a experimental results, Pt was suitable, but $MnO_2$ had a chamber instability when it was reused. The ${\alpha}-Al_2O_3$ which is high heat-resistant support showed very unstable performance in both Pt and $MnO_2$ catalyst since it has low decomposition performance.

  • PDF

An Experimental Study on the Effect of Hydrogen Peroxide in the Treatment of Carbon Monoxide Poisoning (일산화탄소중독(一酸化炭素中毒)의 약물치료효과에 관(關)한 실험적(實驗的) 연구(硏究) -과산화수소(過酸化水素) 관장법(灌腸法)을 중심(中心)으로-)

  • Choi, D.W.;Yoo, K.Y.;Park, H.B.
    • Journal of Preventive Medicine and Public Health
    • /
    • v.13 no.1
    • /
    • pp.13-18
    • /
    • 1980
  • The ultimate goal of treatment of carton monoxide poisoning is to promote dissociation of carboxyhemoglobin and to maintain arterial $PO_2$ above 50mmHg throughout the course of treatment to protect vital organs from damage caused by hypoxia. The hyperbaric chamber designed and manufactured for this purpose has obviousely made an enormous contribution and yet has several handicaps to be overcome by any means. These handicaps are: the financial impact to purchase the chamber (especially in a small, remote community), an extra manpower requirement to operate the device, limitation in the capacity of the chamber (one man type), and the possible hazard of oxygen intoxication and dysbarism. The primary objective of this study is to develope a new therapeutic measure as an alternative to the hyperbaric chamber when it is not available or contraindicated. The effect of intestinal perfusion with hydrogen peroxide has been studied by many investigators and was known to be an excellent way of extrapulmonary oxygen supply. the advantage of this method will include; 1) much more amount of oxygen is delivered to the tissue than one would expect from 100% saturation with oxygen at 1 ata, 2) the procedure is simple and most economical, 3) neither sophisticated equipment nor extra manpower is required. As a study preliminary to the clinical application, authors conducted a series of experiment to observe the effect of hydrogen peroxide enema on dissociation of carboxyhemoglobin in intoxicated rabbit blood. Using an animal gas chamber, 20 rabbits were exposed to CO gas of 6,000 ppm for 60 minutes. Ten rabbits of control group were given 10cc of warmed normal saline solution by reactal perfusion and for the other 10 of the experimental group, the same amount of 1% $H_{2}O_{2}$ solution was given by the same way. Two blood specimens were drawn from each rabbit: the first one immediately following the exposure and the second one after rectal perfusion, about 30 minutes after the first sampling. The result was as follows; 1) The decrease in carboxyhemoglobin concentration during the first 30 minutes in the control and experimental group were $18.18{\pm}4.49%\;and\;23.03{\pm}4.13%$ respectively shelving the significant difference (p<0.05) between the two groups. 2) Hemoglobin and hematocrit value showed no significant difference between two groups and not altered significantly by intestinal perfusion with $H_{2}O_{2}$.

  • PDF

Characteristics of pollutant emission from wallpapers - Around TVOC and HCHO - (벽지에서 발생되는 오염물질 방출특성 - TVOC와 HCHO를 중심으로 -)

  • Jang, Seong-Ki;Kim, Mi-Hyun;Lee, Hong-Suk;Lim, Jun-Ho;Jang, Mee;Seo, Soo-Yun
    • Analytical Science and Technology
    • /
    • v.18 no.6
    • /
    • pp.542-551
    • /
    • 2005
  • This study is to investigate the characteristics of emission concentration according to wallpaper sort and emission time using small chamber method. The target compounds included 45 VOCs and formaldehyde, which were respectively determined by adsorption sampling and thermal desorption coupled with GC/MS method, and by sampling in DNPH cartridge and HPLC method. The emission factor of TVOC and HCHO was detected to $1.1mg/m^2{\cdot}h$ and $0.01mg/m^2{\cdot}h$ respectively, and the wallpapers of 25 satisfied emission standard. TVOC emission factor appeared in order of the concentration of PVC, natural, and Non-PVC wallpaper, while HCHO was detected very low concentration without relation to wallpaper sort. The paraffin hydrocarbons appeared to be the most contributable class of hydrocarbons in terms of their concentrations, followed by aromatics, and olefins, halogenated hydrocarbons was not detected. PVC wallpapers plentifully emitted TVOC above other wallpapers, and toluene was showed higher concentration of 10 times than natural wallpaper. In addition to, emission factor according to elapse was gradually decreased.