• Title/Summary/Keyword: small chamber method

Search Result 158, Processing Time 0.027 seconds

Quenching Effect in an Optical Fiber Type Small Size Dosimeter Irradiated with 290 MeV·u-1 Carbon Ions

  • Hirata, Yuho;Watanabe, Kenichi;Uritani, Akira;Yamazaki, Atsushi;Koba, Yusuke;Matsufuji, Naruhiro
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.3
    • /
    • pp.222-228
    • /
    • 2016
  • Background: We are developing a small size dosimeter for dose estimation in particle therapies. The developed dosimeter is an optical fiber based dosimeter mounting an radiation induced luminescence material, such as an OSL or a scintillator, at a tip. These materials generally suffer from the quenching effect under high LET particle irradiation. Materials and Methods: We fabricated two types of the small size dosimeters. They used an OSL material Eu:BaFBr and a BGO scintillator. Carbon ions were irradiated into the fabricated dosimeters at Heavy Ion Medical Accelerator in Chiba (HIMAC). The small size dosimeters were set behind the water equivalent acrylic phantom. Bragg peak was observed by changing the phantom thickness. An ion chamber was also placed near the small size dosimeters as a reference. Results and Discussion: Eu:BaFBr and BGO dosimeters showed a Bragg peak at the same thickness as the ion chamber. Under high LET particle irradiation, the response of the luminescence-based small size dosimeters deteriorated compared with that of the ion chamber due to the quenching effect. We confirmed the luminescence efficiency of Eu:BaFBr and BGO decrease with the LET. The reduction coefficient of luminescence efficiency was different between the BGO and the Eu:BaFBr. The LET can be determined from the luminescence ratio between Eu:BaFBr and BGO, and the dosimeter response can be corrected. Conclusion: We evaluated the LET dependence of the luminescence efficiency of the BGO and Eu:BaFBr as the quenching effect. We propose and discuss the correction of the quenching effect using the signal intensity ratio of the both materials. Although the correction precision is not sufficient, feasibility of the proposed correction method is proved through basic experiments.

Antenna Measurement on Cylindrical Surface in Fresnel Region Using Direct Far-Field Measurement System

  • Oh, Soon-Soo;Kim, Joung-Myoun;Yun, Jae-Hoon
    • ETRI Journal
    • /
    • v.29 no.2
    • /
    • pp.135-142
    • /
    • 2007
  • The small anechoic chambers built by many small-/medium-sized companies and universities present difficulties in testing electrically large antennas because the chamber size cannot satisfy the far-field criterion of large antennas. In this paper, a method for Fresnel-region measurement on a cylindrical surface with variation of the measurement height is proposed and verified by both calculations and experiments. We implement the proposed method using a direct far-field measurement system by adding a few supporting structures. The results show good accuracy.

  • PDF

Net Ecosystem Productivity Determined by Continuous Measurement Using Automatic Sliding Canopy Chamber

  • Kim, Gun-Yeob;Lee, Seul-Bi;Lee, Jong-Sik;Choi, Eun-Jung
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.1179-1186
    • /
    • 2012
  • For better understanding of carbon cycle dynamics of an agro-ecosystem, an accurate assessment of seasonal and daily $CO_2$ flux is essential to understand the relationship between various environmental factors and crop productivity. We developed the automatic sliding canopy chamber (ASCC) system that measured continuous net ecosystem productivity (NEP) over whole growing season under the natural meteorological rhythm. The ASCC was composed of two main parts which were sliding part for measuring NEP, and automatic opening and closing chamber (AOCC) for measuring soil respiration (SR) on the soil surface. The ASCC was developed by using open flow method for measuring soil $CO_2$ efflux. The disturbance of natural meteorological condition was minimized by opening the base frames. In the field test with barley (Hordeum vulgare L.), NEP was calculated at $140mg\;CO_2\;m^{-2}h^{-1}$ on a clear day using continuous data and eliminated the possibility of overestimate about 16% using one hour data during the day time. Unlike other small scale chamber system, installation on cropping-field made it possible to take any modifications which might be caused by natural environmental condition.

A Study of Heat Flux According to the Initial Temperature of Combustion Chamber and Blight of Probe in a Constant Volume Combustion Chamber (돌출높이와 초기온도 변화에 따른 연소실 벽면에서의 열유속에 관한 연구)

  • Lee Chi-Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.7
    • /
    • pp.1055-1062
    • /
    • 2004
  • As for the Production of internal combustion engines there has been further movement toward development of high Performance engines with improved fuel efficiency as well as a lightweight and a small size. These tendencies help to solve the problems in engines for example, such as thermal load. abnormal combustion and so on. In order to investigate these Problems, a thin film-type probe for measuring instantaneous temperature has been suggested. A method for manufacturing such a probe was established in this study The instantaneous surface temperature of a constant volume combustion chamber was measured by using this probe and the heat flux was obtained through Fourier analysis In order to thoroughly understand the characteristics of combustion. authors measured wall temperature of combustion chamber and calculated heat flux through a cylinder wall while varying the protrusion height of probe. For these Purposes, the instantaneous surface temperature probe was developed. thereby making possible the analysis of instantaneous temperature of wall surface and the detection of unsteady heat flux in the constant volume combustion chamber.

Improvements of Reverberation Chamber's Performance by using Active Noise Control (능동 소음제어를 이용한 잔향실의 저주파 특성 개선 가능성)

  • K. Kim, Young-Key;Oh, Shi-Whan;Moon, Sang-Mu;Im, Jong-Min;Kim, Hong-Bae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.857-861
    • /
    • 2004
  • An active method that improves low frequency characteristics of a reverberation chamber has been proposed. Spatial uniformity of sound pressure at low frequency has been increased by applying active noise control system. The system acts as frequency selective damping materials, which decreases resonance at low frequency and leave high frequency sound field as it is. Linearity of the chamber, which is essential for sound power measurement in the chamber, is guaranteed since fixed control logic has been adopted. Simple application and tests have been done in a small sized rectangular reverberation chamber which has 400Hz cutoff, Loud speakers were used to simulate a noise source and to construct an active noise control system. The spatial distribution of a sound field at 250Hz, 315Hz and 400Hz bands has been measured before and after control. The standard deviation of sound field has been decreased from 3.4dB to 2.5dB. The results show the possibility of active control system as a sound diffuser.

  • PDF

Study on establishment of emission cell test method for liquid phase building materials (방출셀을 이용한 액상건축자재 오염물질 방출시험방법 정립에 관한 연구)

  • Lim, Jungyun;Jang, Seongki;Seo, Sooyun
    • Analytical Science and Technology
    • /
    • v.22 no.3
    • /
    • pp.191-200
    • /
    • 2009
  • The aim of this study was to evaluate and establish of emission test method for liquid phase building materials such as paint, adhesive, sealant by emission cell. A small-scale emission chamber and emission cell were used to evaluate emission of TVOC from paint, adhesive, sealant. The quantity of TVOC emission were measured by a gas chromatography/mass spectrometry (GC/MS). Background concentration of TVOC was below $10{\mu}g/m^3$ in the emission chamber and cell. Air tightness and recovery in chamber and cell showed good results. The recovery of thermal desorber for toluene and n-dodecane were about 120%. The repeatability of response factor and retention time in GC/MS below 30%. The method detection limit of VOCs ranged 0.04~8.82 ng. The concentration of TVOC emission using emission cell was 1.35~1.41 times higher than emission chamber. The correlation of TVOC emission using chamber and cell method was significantly high (r=0.91~0.97).

Thermal Barrier Coating Durability Testing Trends for Thrust Chamber of Liquid-propellant Rocket Engine (액체로켓엔진 연소기 열차폐코팅 내구성 시험 기술동향)

  • Lee, Keum-Oh;Ryu, Chul-Sung;Lim, Byoung-Jik;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.17 no.1
    • /
    • pp.103-115
    • /
    • 2013
  • Durability testing method trends of the thermal barrier coating(TBC) for the combustion chamber of the liquid-propellant rocket engine have been investigated. Many types of the durability testing method such as the mechanical tests to measure surface cohesion force, the thermal fatigue tests with laser, furnace, burner or plasma, the small scale combustion tests using injectors, and the thermo-mechanical fatigue tests were observed. The TBC with sufficient durability can be selected for the use of combustion chamber through such specimen-level tests and the durability can be verified by the tests using the real scale combustion chambers.

Thermal Barrier Coating Durability Testing Trends for Thrust Chamber of Liquid-propellant Rocket Engine (액체로켓엔진 연소기 열차폐코팅 내구성 시험 기술동향)

  • Lee, Keum-Oh;Ryu, Chul-Sung;Lim, Byoung-Jik;Choi, Hwan-Seok
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2012.05a
    • /
    • pp.603-615
    • /
    • 2012
  • Durability testing method trends of the thermal barrier coating(TBC) for the combustion chamber of the liquid-propellant rocket engine has been investigated. Many types of the durability testing method such as the mechanical tests to measure surface cohesion force, the thermal fatigue tests with laser, furnace, burner or plasma, the small scale combustion tests using injectors, and the thermo-mechanical fatigue tests were observed. The TBC with sufficient durability can be selected for the use of combustion chamber through such specimen-level tests and the durability can be verified by the tests using the real scale combustion chambers.

  • PDF

Characteristics of Volatile Organic Compounds Emitted in Building Materials and Their Predictions of Time-dependent Variation

  • Pang, Seung Ki;Sohn, Jang Yeul;Lee, Kwang Ho
    • Architectural research
    • /
    • v.7 no.1
    • /
    • pp.19-26
    • /
    • 2005
  • Unlike other countries, Korea uses various kinds of wall-paper as finishing material. Conventional wall-paper consists of paper and vinyl, and petrochemical ink is used for the decoration of the surface. Adhesive is used to paste the wall with the wall-paper, which emit substantial amounts of VOCs and formaldehyde. In this study, VOCs characteristics emitted from specimens made of concrete, mortar, gypsum board and wall-paper were investigated using small chamber method. Moreover, concentration and emission factor of BTEX(Benzene, Toluene, Ethylbenzene, m,p,o-Xylene) and TVOC were investigated, and concentration and emission factor decay were estimated. As a result of the prediction, both time-dependent concentration decay and cumulative concentration can be converted into the logarithmic scale. Furthermore, prediction equations were developed from the experimental results under accurately controlled experimental conditions. Therefore, there may be difference if the estimated equations are directly applied to real buildings. Further research should be done on the generalization of the developed prediction equations.

A Study on PID Tuning Technique of a Thermal Environment Chamber (열환경 챔버 제어를 위한 PID 튜닝기법 연구)

  • Shin Younggy;Yang Hooncheul;Tae Choon-Seob;Jang Cheol-Yong;Cho Soo;Kim Youngil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.11
    • /
    • pp.1072-1078
    • /
    • 2005
  • The present study has been conducted to tune a PID controller for large thermal systems such as a thermal environment chamber. In spite of large thermal mass of the thermal chamber under test, its response delay time was found to be negligible mainly due to high air recirculation rate. In general, heating and cooling capacities tend to be small compared the size of a thermal environment chamber, which leads to long transient periods of one hour or so. In the study, a PI tuning method is suggested which makes system responses faster while reducing overshoots and hunting by utilizing efficiently proportional band of actuators.