• 제목/요약/키워드: slip critical joint

검색결과 9건 처리시간 0.02초

Evaluation of slip coefficient of slip critical joints with high strength bolts

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Kim, Kang-Seok;Kim, Woo-Bum
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.477-488
    • /
    • 2009
  • A slip critical joint has various values to adopt the proper slip coefficient in various conditions of faying surfaces in the following codes: AISC, AIJ and Eurocode 3. However, the Korean Building Code still regulates the unique slip coefficient, 0.45, regardless of the diverse faying conditions. In this study, the slip resistance test, including five kinds of surface treatments were conducted to obtain the proper slip coefficients available to steel plate KS SM490A. The faying surfaces were comprised of a clean mill, rust, red lead paint, zinc primer, and shot blast treatment. The candidates for high strength bolts were torque-shear bolts, torque-shear bolts with zinc coating, and ASTM A490 bolts. Based on the test results, the specimens with a shot blasted surface and rusted surface exhibited $k_s$, 0.61, and 0.5, respectively. It is recommended that the specimens with zinc primer exhibit $k_s{\geq}0.40$. The clean mill treated surface had prominently lower values, 0.27. For red lead painted treatment, the thickness of the coating affects the determinant of slip coefficient, so it is necessary to establish a minimum $k_s$ of 0.2, with a coating thickness of 65 ${\mu}m$. During 1,000 hours of relaxation, the uncoated surfaces exhibited the loss of clamping force behind 3%, while the coated surfaces within a certain limited thickness exhibited the loss of clamping within a range of 4.71% and 8.37%.

Nonlinear modeling of beam-column joints in forensic analysis of concrete buildings

  • Nirmala Suwal;Serhan Guner
    • Computers and Concrete
    • /
    • 제31권5호
    • /
    • pp.419-432
    • /
    • 2023
  • Beam-column joints are a critical component of reinforced concrete frame structures. They are responsible for transferring forces between adjoining beams and columns while limiting story drifts and maintaining structural integrity. During severe loading, beam-column joints deform significantly, affecting, and sometimes governing, the overall response of frame structures. While most failure modes for beam and column elements are commonly considered in plastic-hinge-based global frame analyses, the beam-column joint failure modes, such as concrete shear and reinforcement bond slip, are frequently omitted. One reason for this is the dearth of published guidance on what type of hinges to use, how to derive the joint hinge properties, and where to place these hinges. Many beam-column joint models are available in literature but their adoption by practicing structural engineers has been limited due to their complex nature and lack of practical application tools. The objective of this study is to provide a comparative review of the available beam-column joint models and present a practical joint modeling approach for integration into commonly used global frame analysis software. The presented modeling approach uses rotational spring models and is capable of modeling both interior and exterior joints with or without transverse reinforcement. A spreadsheet tool is also developed to execute the mathematical calculations and derive the shear stress-strain and moment-rotation curves ready for inputting into the global frame analysis. The application of the approach is presented by modeling a beam column joint specimen which was tested experimentally. Important modeling considerations are also presented to assist practitioners in properly modeling beam-column joints in frame analyses.

볼트이음방식의 블록전단파괴에 미치는 영향에 대한 실험적 연구 (An Experimental Study on the Effects of Bolted Connection Type on the Block Shear Failure)

  • 이진옥;박경현;문지호;이학은;임남형
    • 한국산학기술학회논문지
    • /
    • 제13권11호
    • /
    • pp.5566-5571
    • /
    • 2012
  • 블록전단파괴는 인장부재의 한계상태에 해당하는 것으로 강구조물의 인장부재 또는 연결부 설계 시 주의를 요한다. 많은 연구 결과와 설계기준에서는 블록전단파괴에 대한 볼트 이음 방식의 영향을 고려하지 않고 있다. 본 연구에서는 볼트 이음 방식(지압이음과 마찰이음)이 블록전단파괴의 파괴모드와 파괴강도에 미치는 영향을 분석하고자 인장실험을 실시하였다. 실험결과의 분석으로부터 설계기준, 지압이음, 마찰이음에 따른 파괴모드의 차이를 제시하였으며 마찰이음에서 발생되는 마찰력으로 인한 블록전단파괴강도의 변화를 고찰하였다.

Zn/Al 금속용사 방식공법을 적용한 고력볼트 접합부의 미끄럼계수 평가 (An Evaluation of Slip Coefficient in High Strength Bolt Joint using Zn/Al Metal Spray Corrosion Resistance Method)

  • 김태수;이한승;태성호;안현진;오상훈
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제11권5호
    • /
    • pp.114-122
    • /
    • 2007
  • 강구조물의 고력볼트 마찰접합부에 있어서 마찰면의 부식은 장기적으로 마찰력 감소와 접합부 내력저하를 초래한다. 본 연구는 고력볼트 접합부의 부식을 방지하고 소요 역학적 성질을 만족시키기 위해 접합부의 마찰면에 Zn/Al 금속용사 방청처리 한 고력볼트 접합부를 대상으로 마찰면의 표면처리방법과 피막두께를 주요 변수로 하여 인장시험을 실시하였고, 실험으로 부터 마찰면 표면거칠기와 미끄럼계수를 측정하였다. 무도장 샌드블라스트 처리한 접합부 및 샌드블라스트 처리 후 금속용사를 실시한 볼트 접합부의 미끄럼 계수는 국내 규준의 규정 값과 비교하여 동등 이상의 우수한 미끄럼계수 값을 나타냈다.

볼트 구멍 크기에 따른 TS 고력볼트 접합부 거동 평가 (Evaluation on the Behavior of Slip Critical Joints with TS High Strength Bolts Subjected to a Size of Bolt Holes)

  • 이현주;김강석;나환선;이강민;김현철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권2호
    • /
    • pp.136-143
    • /
    • 2011
  • 고력볼트의 현장 조립시 볼트 구멍 간의 불일치로 인하여 볼트 구멍을 확장하는 경우가 빈번하게 발생하고 있으며, 이를 위해서 외국 기준에서는 볼트 구멍 크기, 형태, 하중 방향에 따라 미끄럼하중에 대한 규정을 따로 두고 있다. 그러나 우리나라의 경우 과대구멍에 대한 시방규정이나 이에 대한 접합부 특성에 관한 연구는 미흡한 실정이다. 따라서, 접합부재 표면처리와 볼트구멍 크기의 변화가 접합부 내력에 어떠한 영향을 미치는 지를 실험을 통해 정량적으로 평가할 필요가 있다. 본 연구에서는 볼트 구멍 크기 및 형태에 따른 접합부의 미끄럼하중의 변화와 체결 후, 장기축력이완의 경향을 분석하기 위하여 160시간 및 800시간 동안 고력볼트의 축력의 변화를 측정하였다. 본 실험대상 고력볼트로 KS B 2819에 규정된 TS(Torque Shear)형 고력볼트를 사용하였다. 표준 볼트구멍 대비 그 외 볼트구멍의 미끄럼하중의 변화는 10% 미만으로 나타났으며, 장기축력이완은 직경 2.5배의 슬롯구멍에서, 2.66%로 가장 높게 나타났다.

A critical steel yielding length model for predicting intermediate crack-induced debonding in FRP -strengthened RC members

  • Dai, Jian-Guo;Harries, Kent A.;Yokota, Hiroshi
    • Steel and Composite Structures
    • /
    • 제8권6호
    • /
    • pp.457-473
    • /
    • 2008
  • Yielding of the internal steel reinforcement is an important mechanism that influences the Intermediate Crack-induced debonding (IC debonding) behavior in FRP-strengthened RC members since the FRP is required to carry additional forces beyond the condition of steel yielding. However, rational design practice dictates an appropriate limit state is defined when steel yielding is assured prior to FRP debonding. This paper proposes a criterion which correlates the occurrence of IC debonding to the formulation of a critical steel yielding length. Once this length is exceeded the average bond stress in the FRP/concrete interface exceeds its threshold value, which proves to correlate with the average bond resistance in an FRP/concrete joint under simple shear loading. This proposed IC debonding concept is based on traditional sections analysis which is conventionally applied in design practice. Hence complex bond stress-slip analyses are avoided. Furthermore, the proposed model incorporates not only the bond properties of FRP/concrete interface but also the beam geometry, and properties of steel and FRP reinforcement in the analysis of IC debonding strength. Based upon a solid database, the validity of the proposed simple IC debonding criterion is demonstrated.

Evaluating long-term relaxation of high strength bolts considering coating on slip faying surface

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Choi, Sung-Mo
    • Steel and Composite Structures
    • /
    • 제16권6호
    • /
    • pp.703-718
    • /
    • 2014
  • The initial clamping forces of high strength bolts subjected to different faying surface conditions drop within 500 hours regardless of loading, any other external force or loosening of the nut. This study develops a mathematical model for relaxation confined to creep on a coated faying surface after initial clamping. The quantitative model for estimating relaxation was derived from a regression analysis for the relation between the creep strain of the coated surface and the elapsed time for 744 hours. This study establishes an expected model for estimating the relaxation of bolted joints with diverse coated surfaces. The candidate bolts are dacro-coated tension control bolts, ASTM A490 bolt, and plain tension control bolts. The test parameters were coating thickness, species of coating. As for 96, 128, 168, and $226{\mu}m$ thick inorganic zinc, when the coating thickness was increased, relaxation after the initial clamping rose to a much higher range from 10% to 18% due to creep of the coating. The amount of relaxation up to 7 days exceeded 85% of the entire relaxation. From this result, the equation for creep strain can be derived from a statistical regression analysis. Based on the acquired creep behavior, it is expected that the clamping force reflecting relaxation after the elapse of constant time can be calculated from the initial clamping force. The manufacturer's recommendation of inorganic zinc on faying surface as $75{\mu}m$, appears to be reasonable.

Seismic performance of RC frame having low strength concrete: Experimental and numerical studies

  • Rizwan, Muhammad;Ahmad, Naveed;Khan, Akhtar Naeem
    • Earthquakes and Structures
    • /
    • 제17권1호
    • /
    • pp.75-89
    • /
    • 2019
  • The paper presents experimental and numerical studies carried out on low-rise RC frames, typically found in developing countries. Shake table tests were conducted on 1:3 reduced scaled two-story RC frames that included a code conforming SMRF model and another non-compliant model. The later was similar to the code conforming model, except, it was prepared in concrete having strength 33% lower than the design specified, which is commonly found in the region. The models were tested on shake table, through multiple excitations, using acceleration time history of 1994 Northridge earthquake, which was linearly scaled for multi-levels excitations in order to study the structures' damage mechanism and measure the structural response. A representative numerical model was prepared in finite element based program SeismoStruct, simulating the observed local damage mechanisms (bar-slip and joint shear hinging), for seismic analysis of RC frames having weaker beam-column joints. A suite of spectrum compatible acceleration records was obtained from PEER for incremental dynamic analysis of considered RC frames. The seismic performance of considered RC frames was quantified in terms of seismic response parameters (seismic response modification, overstrength and displacement amplification factors), for critical comparison.

Stereo-digital image correlation in the behavior investigation of CFRP-steel composite members

  • Dai, Yun-Tong;Wang, Hai-Tao;Ge, Tian-Yuan;Wu, Gang;Wan, Jian-Xiao;Cao, Shuang-Yin;Yang, Fu-Jun;He, Xiao-Yuan
    • Steel and Composite Structures
    • /
    • 제23권6호
    • /
    • pp.727-736
    • /
    • 2017
  • The application of carbon fiber reinforced polymer (CFRP) in steel structures primarily includes two categories, i.e., the bond-critical application and the contact-critical application. Debonding failure and buckling failure are the main failure modes for these two applications. Conventional electrometric techniques may not provide precise results because of the limitations associated with single-point contact measurements. A nondestructive full-field measurement technique is a valuable alternative to conventional methods. In this study, the digital image correlation (DIC) technique was adopted to investigate the bond behavior and buckling behavior of CFRP-steel composite members. The CFRP-to-steel bonded joint and the CFRP-strengthened square hollow section (SHS) steel column were tested to verify the suitability of the DIC technique. The stereo-DIC technique was utilized to measure continuous deformation. The bond-slip relationship of the CFRP-to-steel interface was derived using the DIC data. Additionally, a multi-camera DIC system consisting of four stereo-DIC subsystems was proposed and applied to the compressive test of CFRP-strengthened SHS steel column. The precise buckling location and CFRP delamination of the CFRP-strengthened SHS steel column were identified. The experimental results confirm that the stereo-DIC technique can provide effective measurements for investigating the behaviors of CFRP-steel composite members.