• Title/Summary/Keyword: slice

Search Result 982, Processing Time 0.042 seconds

Detection of Laver Aquaculture Site of Using Multi-Spectral Remotely Sensed Data (다중분광 위성자료를 이용한 김 양식어장 탐지)

  • Jeong, Jongchul
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.3
    • /
    • pp.127-134
    • /
    • 2005
  • Recently, aquaculture farm sites have been increased with demand of the expensive fish species and sea food like as seaweed, laver and oyster. Therefore coastal water quality have been deteriorated by organic contamination from marine aquaculture farm sites. For protecting of coastal environment, we need to control the location of aquaculture sites. The purpose of this study is to detect the laver aquaculture sites using multispectral remotely sensed data with autodetection algorithm. In order to detect the aquaculture sites, density slice and contour and vegetation index methods were applied with SPOT and IKONOS data of Shinan area. The marine aquaculture farm sites were extracted by density slice and contour methods with one band digital number(DN) carrying 65% accuracy. However, vegetation index algorithm carried out 75% accuracy using near-infra red and red bands. Extraction of the laver aquaculture site using remotely sensed data will provide the efficient digital map for coastal water management strategies and red tide GIS management system.

A study on conversion of cross-sectional information form STL file for Stereolithography (Stereolithography를 위한 STL파일로부터 단면정보 변환에 관한 연구)

  • 최홍태;김준안;이석희;백인환
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.445-450
    • /
    • 1995
  • This paper deals with conversion from STL file to Slice cross-sectional information for Stereolithography. The STL file consist of three vertices of triangle and normal vectors in order to represent three dimension shape, but It is very difficult to convert STL file intoSlice file directly, because of file size from one Mbyte to tens of Mbytes. So, The system is accomplished data flow such as neutral.dat, .SL1, .SL2, .SL3, and .SLC file. The data processing is as follows: 1. Create a neutral file including common information. 2. Modify STL file within effective scope of SLA. 3. Calculate a point of intersection between plane equation and line equation. 4. Sort z values by increasing order. 5. Search closed loop by method of singlylinked linear list. The system is developed by using Borland C++ 3.1 compiler in the environment of Pentium PC. We get a satisfactory prototype as a result of application about a lot of household electrical appliances.

  • PDF

A Study on the Bit-slice Signal Processor for the Biological Signal Processing (생체 신호처리용 Bit-slice Signal Processor에 관한 연구)

  • Kim, Yeong-Ho;Kim, Dong-Rok;Min, Byeong-Gu
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.15-22
    • /
    • 1985
  • We have developed a microprogramir!able signal processor for real-time ultrasonic signal processing. Processing speed was increased by the parallelism in horizontal microprogram using 104bits microcode and the Pipelined architecture. Control unit of the signal processor was designed by microprogrammed architec- ture and writable control store (WCS) which was interfaced with host computer, APPLE- ll . This enables the processor to develop and simulate various digital signal processing algorithms. The performance of the processor was evaluated by the Fast Fourier Transform (FFT) program. The execution time to perform 16 bit 1024 points complex FF7, radix-2 DIT algorithm, was about 175 msec with IMHz master Clock. We can use this processor to Bevelop more efficient signal processing algorithms on the biological signal processing.

  • PDF

Calculation of Electromagnetic Excitation Forces in Double Skewed Motors

  • Bao, Xiaohua;Di, Chong;Zhou, Yang
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.2
    • /
    • pp.812-821
    • /
    • 2018
  • An electromagnetic excitation force is caused by the air-gap flux density, which greatly influences the noise and vibration of the motor. In many real projects, skewed slot technology is widely used to reduce the harmonic components of the air-gap flux density to reduce the noise and vibration of the motor. However, a skewed slot has several side effects such as a transverse current and axial drifting. Thus, a double skewed slot rotor is selected with the aim of eliminating these side effects. This paper presents the exact structure of the double skewed slot rotor and the mechanism whereby the electromagnetic excitation force can be reduced. A multi-slice method is adopted to model the special structure. Finite element simulation is used to verify the theory.

Proccessing of citrus-tea and its characteristics (제주산 감귤류차의 제조와 그 특성)

  • Go, Jeong-Sam;Yang, Yeong-Taek;Kim, Yong-Cheol
    • Food Science and Preservation
    • /
    • v.3 no.1
    • /
    • pp.7-13
    • /
    • 1996
  • Total carbohydrates of Kumquats was 14.69% Kumquats, Citrus natsudaidai, and C. platgmama contained 18.3, 11.1 and 13.0%, of soluble solids, and 42.39, 32.09 and 20.13mg/100g, of vitamin C, respectively. Acid contents of C. natsudaidai and C. plafmama harvested on March 1995 in south Cheju were 2.52% and 0.89% . In preparing of Kumquats-tea, combination of 50% honey and sugar, 5% oligo-sugar, 32% Kumquats slice, 13% juice of C. natsudaidai were the best recipe for sensory evaluation. In C. natsudaidai-tea, combination of 5∼10% peel slice treated at 90$^{\circ}C$ for 1min, 50∼60% concentration of sugar and 35∼40% of flesh of C. natsudaidai were good. for sensory evaluation. Microbial growth was not observed in the sterilized products for more than one month at 30$^{\circ}C$.

  • PDF

An Internal Pattern Run-Length Methodology for Slice Encoding

  • Lee, Lung-Jen;Tseng, Wang-Dauh;Lin, Rung-Bin
    • ETRI Journal
    • /
    • v.33 no.3
    • /
    • pp.374-381
    • /
    • 2011
  • A simple and effective compression method is proposed for multiple-scan testing. For a given test set, each test pattern is compressed from the view of slices. An encoding table exploiting seven types of frequently-occurring pattern is used. Compression is then achieved by mapping slice data into codewords. The decompression logic is small and easy to implement. It is also applicable to schemes adopting a single-scan chain. Experimental results show this method can achieve good compression effect.

The Role of Dynamic Contrast Enhanced MR Mammography in Differentiation between Benign and Malignant Breast Lesions

  • 한송이;차은숙;정상설;김학희;변재영;이재문
    • Proceedings of the KSMRM Conference
    • /
    • 2002.11a
    • /
    • pp.135-135
    • /
    • 2002
  • Purpose: To assess diagnostic accuracy of dynamic contrast enhanced MR mammography in differentiating between benign and malignant lesions. Materials and methods: Ninety-three patients with suspicious mammographic, sonographic or palpable findings underwent pre- or postoperative contrast-enhanced MR imaging of breast using three dimensional fast low-angle shot (3D FLASH) sequence (16/4 msec[repetition time / echo time], 20 flip angle, 3mm slice thickness with no slice gap, 256 by 256 in-plane matrix) covering whole breasts. T1 weighted images were obtained before and after bolus administration of gadopentetate dimeglumine (0.15 mmol/kg). Subtraction images and time-signal intensity curves of region of interest were obtained sequentially and correlated with pathologic diagnoses of lesions.

  • PDF

Effects of Forskolin on Endogenous Dopamine and Acetylcholine Release in Rat Neostriatal Slices

  • Kim, Hwa-Jung
    • Archives of Pharmacal Research
    • /
    • v.19 no.6
    • /
    • pp.520-528
    • /
    • 1996
  • The involvement of the cyclic AMP (cAMP) effector system in the release of endogenous dopamine and acetylcholine from the rat neostriatum was assessed. Forskolin, an activator of adenylate cyclase, was used to enhance cAMP production, and the consequence of this enhancement on the spontaneous and potassium stimulated release of dopamine and acetylcholine was evaluated. Neostriatal slices were prepared from Fischer 344 rats and after a preincubation period the release of each endogenous neurotransmitter was measured from the same slice preparation. To measure acetylcholine release the slice acetylcholinesterase (AChE) activity was inhibited with physostigmine, but the release from slices with intact AChE activity was also determined (choline, instead of acetylcholine was detected in the medium). Under both conditions forskolin induced a significant dose-dependent increase in the potassium-evoked release of dopamine. In the same tissue preparations the release of neither acetylcholine (AChE inhibited) nor choline (AChE intact) was affected by forskolin. The results indicate that the CAMP second messenger system might be involved in neuronal mechanisms that enhance neostriatal dopamine release, but stimulation of this second messenger by forskolin does not further enhance neostriatal acetylcholine release.

  • PDF

Design of Moving Object Detector Based on Gaussian Mixture Model (Gaussian Mixture Model 기반 이동 객체 검출기의 하드웨어 구조 설계)

  • Cho, Jae-Chan;Jung, Yong-Chul;Yoon, Kyunghan;Jung, Yunho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2015.10a
    • /
    • pp.1571-1572
    • /
    • 2015
  • 본 논문에서는 GMM (Gaussian mixture model) 기반의 BS (background subtraction) 알고리즘을 이용한 이동 객체 검출기의 하드웨어 구조 설계 결과를 제시하였다. 설계된 이동객체 검출기는 1280 * 720 HD 해상도의 영상을 30 frames per second로 실시간 처리가 가능하다. 하드웨어 구현은 Verilog-HDL을 이용하였으며, FPGA 기반 구현 결과, 설계된 이동 객체 검출기는 582 Slice, 1,698 Slice LUT, 8 DSP48s, 1,769 Flip Flop, 691.2 KByte BRAM으로 구성되었음을 확인하였다.