• 제목/요약/키워드: slab deflection

검색결과 220건 처리시간 0.03초

Loading capacity evaluation of composite box girder with corrugated webs and steel tube slab

  • He, Jun;Liu, Yuqing;Xu, Xiaoqing;Li, Laibin
    • Structural Engineering and Mechanics
    • /
    • 제50권4호
    • /
    • pp.501-524
    • /
    • 2014
  • This paper presents a type of composite box girder with corrugated webs and concrete filled steel tube slab to overcome cracking on the web and reduce self-weight. Utilizing corrugated steel web improves the efficiency of prestressing introduced into the top and bottom slabs due to the accordion effect. In order to understand the loading capacity of such new composite structure, experimental and numerical analyses were conducted. A full-scale model was loaded monotonically to investigate the deflection, strain distribution, loading capacity and stiffness during the whole process. The experimental results show that test specimen has enough loading capacity and ductility. Based on experimental works, a finite element (FE) model was established. The load-displacement curves and stress distribution predicted by FE model agree well with that obtained from experiments, which demonstrates the accuracy of proposed FE model. Moreover, simplified theoretical analysis was conducted depending on the assumptions which were confirmed by the experimental and numerical results. The simplified analysis results are identical with the tested and numerical results, which indicate that simplified analytical model can be used to predict the loading capacity of such composite girder accurately. All the findings of present study may provide reference for the application of such structure in bridge construction.

Modelling of bonded and unbonded post-tensioned concrete flat slabs under flexural and thermal loading

  • Mohammed, Abbas H.;Taysi, Nildem
    • Structural Engineering and Mechanics
    • /
    • 제62권5호
    • /
    • pp.595-606
    • /
    • 2017
  • During their life span, post-tensioned concrete structures may be exposed to thermal loads. Therefore, there has been a growing interest in research on the advanced analysis and design of post-tensioned concrete slabs subjected to thermal loads. This paper investigates the structural behaviour of post-tensioned one-way spanning concrete slabs. A nonlinear finite element model for the analysis of post- tensioned unbonded and bonded concrete slabs at elevated temperatures was developed. The interface between the tendon and surrounding concrete was also modelled, allowing the tendon to retain its profile shape during the deformation of the slab. The load-deflection behaviour, load-force behaviour in the tendon, and the failure modes are presented. The numerical analysis was conducted by the finite element ANSYS software and was carried out on two different one-way concrete slabs chosen from literature. A parametric study was conducted to investigate the effect of several selected parameters on the overall behavior of post-tensioned one-way concrete slab. These parameters include the effect of tendon bonding, the effect of thermal loading and the effect of tendon profile. Comparison between uniform thermal loading and nonuniform thermal loading showed that restrained post tensioned slab with bottom surface hotter has smaller failure load capacity.

Experimental and analytical studies on one-way concrete slabs reinforced with GFRP molded gratings

  • Mehrdad, Shokrieh Mahmood;Mohammad, Heidari-Rarani
    • Steel and Composite Structures
    • /
    • 제9권6호
    • /
    • pp.569-584
    • /
    • 2009
  • Corrosion of steel rebars in bridge decks which are faced to harsh conditions, is a common problem in construction industries due to the porosity of concrete. In this research, the behavior of one-way concrete slabs reinforced with Glass fiber reinforced polymer (GFRP) molded grating is investigated both theoretically and experimentally. In the analytical method, a closed-form solution for load-deflection behavior of a slab under four-point bending condition is developed by considering a concrete slab as an orthotropic plate and defining stiffness coefficients in principal directions. The available formulation for concrete reinforced with steel is expanded for concrete reinforced with GFRP molded grating to predict ultimate failure load. In finite element modeling, an exact nonlinear behavior of concrete along with a 3-D failure criterion for cracking and crushing are considered in order to estimate the ultimate failure load and the initial cracking load. Eight concrete slabs reinforced with steel and GFRP grating in various thicknesses are also tested to verify the results. The obtained results from the models and experiments are relatively satisfactory.

교량상 slab궤도의 상향력 민감도분석 (Parameteric Analysis for Up-lifting force on Slab track of Bridge)

  • 최성기;박대근;한상윤;강영종
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 추계학술대회 논문집
    • /
    • pp.1188-1195
    • /
    • 2007
  • The vertical forces in rail fasteners at areas of bridge transitions near the embankment and on the pier will occur due to different deformations of adjoining bridges caused by the trainloads, the settlement of supports, and the temperature gradients. The up-lifting forces is not large problem in the blast track because the elasticity of blast and rail pad buffs up-lifting effect. But, it is likely to be difficult to ensure the serviceability of the railway and the safety of the fastener in the end in that concrete slab track consist of rail, fastener, and track in a single body, delivering directly the up-lifting force to the fastener if the deck is bended because of various load cases, such as the end rotation of the overhang due to the vertical load, the bending of pier due to acceleration/braking force and temperature deviation, the settlement of embankment and pier, the temperature deviation of up-down deck and front-back pier, and the rail deformation due to wheel loads. The analysis of the rail fastener is made to verify the superposed tension forces in the rail fastener due to various load cases, temperature gradients and settlement of supports. The potential critical fasteners with the highest uplift forces are the fastener adjacent to the civil joint. The main influence factors are the geometry of the bridge such as, the beneath length of overhang, relative position of bridge bearing and fastener, deflection of bridge and the vertical spring stiffness of the fastener.

  • PDF

탄성기초에 지지되고 양단 축하중을 받는 특별직교 이방성 판의 진동해석 (Vibration analysis of special orthortopic plate with free edges supported on elastic foundation and with a pair of opposite edges under axial forces)

  • 김덕현;원치문;정경일;박정호
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 봄 학술발표회 논문집
    • /
    • pp.327-334
    • /
    • 1998
  • A method of calculating the natural frequency corresponding to the first mode of vibration of beams and toll.or structures, with irregular cross sections and with arbitrary boundary conditions was developed and reported by Kim, D. H. in 1974. In this paper, the result of application of this method to the special orthotropic plates with free edges supported on elastic foundation and with a pair of opposite edges under axial forces is presented. Such plates represent the concrete highway slab and hybrid composite pavement of bridges. The reinforced concrete slab can be assumed as a special orthotropic plate, as a close approximation. The highway slab is supported on elastic foundation, with free boundaries. Sometimes, the pair of edges perpendicular to the traffic direction may be subject to the axial forces. The plate is subject to the concentrated load/loads, in the form of traffic loads, or the test equipments. Any method nay be used to obtain the deflection influence surfaces needed for this vibration analysis. Finite difference method is used for this purpose, in this paper. The influence of the modulus of the foundation, the aspect ratio of the plate, and the magnitudes of the axial forces and the concentrated attached mass on the plate, on the natural frequency is thoroughly studied.

  • PDF

Research on flexural bearing capacity of cold-formed thin-walled steel and reinforced concrete sandwich composite slabs

  • Qiao, Wentao;Huang, Zhiyuan;Yan, Xiaoshuo;Wang, Dong;Meng, Lijun
    • Steel and Composite Structures
    • /
    • 제45권2호
    • /
    • pp.219-230
    • /
    • 2022
  • The aim of this paper is to study the mechanical behaviors of the cold-formed thin-walled steel and reinforced concrete sandwich composite slab (CTS&RC-SCS) under vertical loads and to develop the calculation methods of its flexural bearing capacity and section stiffness. Two CTS&RC-SCS specimens were designed and manufactured to carry out the static loading test, and meanwhile, the numerical simulation analyses based on finite element method were implemented. The comparison between experimental results and numerical analysis results shows that the CTS&RC-SCS has good flexural capacity and ductility, and the accuracy and rationality of the numerical simulation analysis are verified. Further, the variable parameter analysis results indicate that neither increasing the concrete strength grade nor increasing the thickness of C-sections can significantly improve the flexural capacity of CTS&RC-SCS. With the increase of the ratio of longitudinal bars and the thickness of the composite slab, the flexural capacity of CTS&RC-SCS will be significantly increased. On the basis of experimental research and numerical analysis above, the calculation formula of the flexural capacity of CTS&RC-SCS was deduced according to the plastic section design theory, and section stiffness calculation formula was proposed according to the theory of transformed section. In terms of the ultimate flexural capacity and mid-span deflection, the calculated values based on the formulas and the experimental values are in good agreement.

집중하중을 받는 GFRP 보강근 경량콘크리트 슬래브의 거동 (Behaviour of Lightweight Concrete Slab Reinforced with GFRP Bars under Concentrated Load)

  • 손병락;김충호;장희석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제19권4호
    • /
    • pp.57-66
    • /
    • 2015
  • 본 연구는 경량콘크리트와 GFRP 보강근을 휨보강근으로 사용하여 제작되는 GFRP 보강근 경량콘크리트 슬래브를 교량 슬래브 등에 활용해보기 위한 사전 연구로서, 기존의 철근 콘크리트 슬래브와 GFRP 보강근 경량콘크리트 슬래브의 휨 거동 차이점 분석에 초점을 두었다. 이를 위하여 일련의 슬래브 실험체들을 제작하고 3점 휨 실험 및 수치해석을 행하였다. 실험 결과, GFRP 보강근 경량콘크리트 슬래브 실험체는 GFRP 보강근의 과다보강으로 인하여 실험체 하부에 발생된 초기균열이 하중 재하면의 콘크리트 압축부까지 연결되면서 전단파괴되는 경향을 보였다. 그리고 철근 콘크리트로 제작된 슬래브 실험체에 비하여 무게는 72%이었으며 휨 실험에서의 파괴하중은 58%인 것으로 나타났다. 한편, midas FEA를 이용하여 행한 수치해석 과정은 실험에서 나타난 전단파괴 하중까지 잘 모사하였다. 그러나 GFRP 보강근의 인장강도 대신 탄성계수가 입력값으로 요구됨에 따라 가력되는 하중과 처짐은 실험에서 나타난 전단파괴 이후에도 계속하여 증가하는 경향을 보였다.

처짐법을 이용한 무근콘크리트 포장하부의 공동탐사 (Detection of Void Beneath the Plain Reinforced Concrete Pavement Using Deflection Method)

  • 변근주;이상민;김영진;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1989년도 가을 학술발표회 논문집
    • /
    • pp.43-47
    • /
    • 1989
  • In recent years, it has been found that one of the most significant factors in the reduction of the life of concrete pavements is the presence of voids beneath the slab. In the design of pavement, it is assumed that there is a full support through the length of the pavement. When a void develops, this assumption is no longer vaild. With increasing void size, traffic loads have a very a significant increase in stress. Thus, the combination of existing voids and increasing traffic loads results in significant pavement life reduction. Basea on the results of an experimental deflection using Dynaflect device and a theoretical one on the pavement model, this study presents a rational evaluation technique for detecting voids beneath the plain reinforced concrete pavement.

  • PDF

Tests of concrete slabs reinforced with CFRP prestressed prisms

  • Liang, Jiongfeng;Yu, Deng;Yang, Zeping;Chai, Xinjun
    • Computers and Concrete
    • /
    • 제18권3호
    • /
    • pp.355-366
    • /
    • 2016
  • This paper reports the testing of concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) on the flexural behavior. Four concrete slabs were tested, a reference slab reinforced with steel bars, and three slabs reinforced with CFRP prestressed concrete prisms (PCP). All slabs were made with dimensions of 600mm in width, 2200mm in length and 150 in depth. All concrete slabs reinforced with CFRP prestressed concrete prisms(PCP) exhibited CFRP bar rupture failure mode. It was shown that the application of the CFRP prestressed prisms can limit service load deflections and crack width, the increased level of prestress in the CFRP prestressed prism positively affected the maximum crack width. The deflection of concrete slabs reinforced with CFRP prestressed prisms decreased as prestress in the CFRP prestressed prism increased.

3경간 연속 Extradosed PSC 철도교의 동적거동에 관한 연구 (A Study on the Dynamic Behavior a 3 Span Continuous Extradosed PSC Railway Bridge)

  • 김성일;김연태;길태수
    • 한국철도학회논문집
    • /
    • 제9권2호
    • /
    • pp.137-144
    • /
    • 2006
  • The Extradosed PSC bridge is one of the best alternates which not only covers the longer span than PSC box girder and also performs the role of landmark facility with much cheaper cost than cable stayed bridge. Since the cable-stayed long span bridge is more flexible than general medium span bridges and railway bridges can be experienced resonance phenomenon by repeated equidistant axle loading of the train, it is inevitable to consider the dynamic behavior on impact, deflection and so on. In the present study, the dynamic behavior of an Extradosed PSC railway bridge subjected to moving train forces is analyzed. As well as trains which operate in conventional railway tines, KTX train is also considered. For the estimation of dynamic performances of the Extradosed PSC bridge, vertical deflection, accelerations of the slab, end rotation of the girder and impact on pylons and cables are discussed.