• 제목/요약/키워드: skin measurement

검색결과 625건 처리시간 0.035초

각성도 제어를 위한 평가기준의 설정 및 경고음의 효과분석 (Evaluation of the Criteria for the Control of Arousal Level and Effect of Warning Signal)

  • 김연호
    • 대한의용생체공학회:의공학회지
    • /
    • 제18권1호
    • /
    • pp.79-86
    • /
    • 1997
  • This paper describes the development of portable arousal measurement and analysis system. Skin impedance change which responds to the change of arousal level was detected by the three elctrode constant current method and separated into two components(SIR, SIL). Relationship between Nz, IRI and arousal level was studied and criteria of arousal level control was decided by the sleep study. Measured data with and without warning signal were compared and analyzed.

  • PDF

양성자 치료에서 생체 내 선량측정 검출기(In-vivo dosimety)의 정확성과 유용성에 관한 연구 (A Study on Accuracy and Usefulness of In-vivo Dosimetry in Proton Therapy)

  • 김선영;최재혁;원희수;홍주완;조재환;이선엽;박철수
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.171-180
    • /
    • 2014
  • 본 연구는 양성자 치료를 시행하고 있는 수모세포종 환자의 양성자 치료 시 환자들의 Skin에서 홍반이나 피부염이 발생하는 경우가 빈번하여 Phantom에서 실제 환자와 동일한 치료계획 후 생체 내 선량측정 검출기(In-vivo dosimetry)로 사용되는 열 형광선량계(Thermo-luminescence Dosimeter, TLD)와 EBT3 Film으로 실제선량을 조사 측정한다. 측정된 선량값을 치료계획 된 피부선량과 비교 분석하여 양성자 치료 시 임상적으로 피부선량 측정 사용에 유용성이 있는지 알아보고자 한다. Phantom을 수모세포종의 전뇌척수치료(Cranio-spinal irradiation, CSI) Set-up position으로 위치하여 Brain에서 부터 Pelvis까지 CT촬영하고 양성자 치료계획 후 치료실에서 디지털 영상 포지셔닝 시스템(Digital Imaging Positioning System, DIPS)을 이용하여 정확하게 치료 Isocenter지점을 맞춘다. 양성자 빔이 들어가는 5부위의 치료 Isocenter 지점과 CT촬영 시 Phantom에 표시한 Marker 2부위, 모두 7지점에 미리 교정을 마친 열 형광선량계와 EBT3 Film을 교차해가면서 위치하여 붙이고 치료 계획된 양성자 빔을 각각 10회씩 조사한다. 10회 반복 측정하여 얻은 값을 평균산출하여 치료계획 시스템 에서 측정된 Skin Dose와 비교 분석한 결과, 측정위치의 어려움이 있는 정확한 측정이 결여된 한 지점을 제외한 나머지 6지점의 측정 선량값은 열 형광선량계와 EBT3 Film 모두 절대 선량값과 ${\pm}2%$이내의 분포를 보였다. 결론적으로, 본 연구에서는 국내 최초의 양성자 치료에서 Enterance skin dose 측정을 위한 In-vivo dosimetry로 열 형광선량계와 EBT3 Film의 임상적인 유용성을 확인하였다.

직장암 3문조사와 자궁경부암 4문조사 방사선 치료 시 유리선량계를 이용한 피부선량 측정에 관한 연구 (A Study on the Skin Dose Measurement of Glass Dosimeter Use During Rectal Cancer 3field Technic and Cervical Cancer 4field Technic Radiation Therapy)

  • 신성수;최원식;박철수;이선엽;조재환;서정민;심재구;김찬형;구은회;김응찬
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권2호
    • /
    • pp.157-163
    • /
    • 2011
  • 현재의 방사선 치료의학은 고도로 발전하여 다양한 기술의 방사선 치료기술(IMRT, SRS, 3D-RT, 등)이 행하여지고 있다. 자궁경부암의 방사선 치료나 직장암의 방사선 치료에서는 아직까지 보편화된 치료법인 3문 조사법이나 4문조사법을 실시하고 있다. 2차원 치료 시 치료부위 피부에 방사선에 의한 화상이 생기게 된다. 이러한 피부 부작용은 방사선 치료의 대표적인 부작용이라 할 수 있다. 지금까지는 피부선량 측정에 있어서 1회 측정으로 총 치료기간을 환산하여 피부선량을 기술하였다. 본 연구에서는 환자의 매회 치료 시 마다 피부선량을 측정하였다. 피부선량 측정에는 누적선량 측정에 적합한 유리선량계를 사용하였다. 피부선량 측정 후 치료계획 장치에서 측정한 피부선량과 비교 분석하였다. 치료기간 동안 매번 측정한 피부선량과 치료 계획 장치에서 계산한 선량을 서로 유의성 분석을 실시한 결과 유의하다는 결과를 없었다. 환자치료 시 움직임에 의한 오차가 있음에도 치료 계획 장치의 계산 선량과 비교하여도 오차범위에 합당하였다.

폴리올을 이용한 각질층 수분량 측정의 표준화 연구 (Standardization of Hydration in the Stratum Corneum Using by Polyols)

  • 남개원
    • 대한화장품학회지
    • /
    • 제41권2호
    • /
    • pp.113-119
    • /
    • 2015
  • 피부의 최외곽층인 각질층에 대한 수분량을 측정하는 것은 피부장벽기능과 생물리학적 특성에 대한 피부 건강함, 유연함, 부드러움 등의 중요한 정보를 제공한다. 그러나, 평가자와 피험자와의 개인적인 차이와 측정환경의 변화에 따라 재현성과 반복성에 있어서 각질층의 수분량을 측정하는 데에는 많은 어려움이 있다. 본 연구의 목적은 피부 각질층에 여러 종류의 제품을 사용 전후에 객관적으로 수분량을 측정하는 데에 있다. 40명의 건강한 자발적 피험자의 하박 내측을 피부의 전기용량 특성을 이용하여 수화정도를 측정하였다. 피부 수분량은 시험제품 도포 후, 3 h, 6 h 뒤에 측정하였다. 무도포 부위의 편차를 보정하기 위해 수분증가율을 이용하였고, 5반복 측정을 통하여 분석하였다. 수분량 측정에 가장 효과를 보이는 대표적 폴리올 종류인 글리세롤과 부틸렌 글라이콜을 이용하여 연구를 수행하였다. 대부분의 폴리올 종류는 피부 수분량 변화에 영향을 미치기 때문에 연구에 참여한 피험자에게 0 ~ 20%의 글리세롤을 표준제품으로 사용하여 보정하였다. 피부 수분량은 낮은 농도의 글리세롤 범위에서 직선의 상관관계를 갖기 때문에, 글리세롤의 농도에 따라 피부 수분량에 대한 피험자 각각의 표준화된 곡선을 얻었다. 이렇게 얻어진 피부 수분량에 대응하는 글리세롤 농도 값은 통계학적으로 재현성과 반복성을 보였다. 게다가 이렇게 얻어진 표준화 곡선은 피험자 개인의 피부특성으로 활용할 수 있었다. 이러한 연구 결과는 화장품과 같은 피부외용제품에 대한 미세한 피부 상태의 변화와 외부환경 변화에도 불구하고, 같은 결과를 보였다. 향후 이러한 결과를 토대로, 계면활성제와 지질, 수용성 물질에 대한 제품 원료에 대한 피부 측정에 필요한 비침습적 방법과 병행해서 사용할 수 있을 것으로 사료된다.

생체 임픽던스 측정에 의한 상지 운동 감지 시스템 (A Human Arm Movement Detection System Using Electrical Bioimpedance Measurement)

  • 김종찬;김수찬;남기창;박민용;김경환;김덕원
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제51권8호
    • /
    • pp.374-379
    • /
    • 2002
  • In this study, we developed a new human arm movement detection system using electrical bio-impedance method with several skin-electrodes. The correlation coefficients of the joint angle and the impedance change from human arm movement was obtained using a goniometer and impedance measurement system developed in this study. The correlation coefficients of the wrist and the elbow movements were 0.94 and -0.99, respectively. This system was applied to control a robotic arm by converting the measured impedance to joint angle to confirm the validity of the proposed system. In conclusion, we confirmed that this system can control the robotic arm according to arm movement without any limitation of movement. This system showed possibility that upper arm movement could be easily measured by impedance measurement system with a few skin-electrodes.

미소안면침 시술 후 안면 주름 측정값 변화에 대한 임상적 고찰 (Clinical Study on Facial Skin Furrow Measurement Changes after Miso Facial Rejuvenation Acupuncture)

  • 권나현;김찬영;신예지;서산;송정화;백용현;우현수;박동석
    • Journal of Acupuncture Research
    • /
    • 제26권6호
    • /
    • pp.133-140
    • /
    • 2009
  • Objectives : Miso facial rejuvenation acupuncture is a Korean medical treatment technique for face lifting. The authors aimed to evaluate the effects of Miso facial rejuvenation acupuncture on facial skin furrows. Methods : 11 patients who made first visits to Hyo-Jun Korean Medical Clinic from October 1, 2009 to October 25, 2009 were each given one-time treatment of Miso facial rejuvenation acupuncture treatment. A portable fluorescent dermal diagnostic equipment, ECOSKIN, was used to measure extraocular skin furrows and perioral skin furrows width and depth before and after treatment. Results : Mean width and depth of both the extraocular and perioral skin furrows decreased after one-time Miso facial rejuvenation acupuncture treatment. Extraocular skin furrow width, depth, and perioral skin furrow width showed statistically significant decreases(p=0.003, 0.017, 0.041 respectively). Conclusions : Mean depth and width of both the extraocular and perioral skin furrows decreased after receiving Miso facial rejuvenation acupuncture treatment. Miso facial rejuvenation acupuncture may be an effective treatment for improving wrinkles in clinic.

  • PDF

횡 방향 공동을 이용한 마찰 저항 감소 (Reduction of the Skin Friction Drag Using Transverse Cavities)

  • 김철규;전우평;최해천
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.397-400
    • /
    • 2006
  • In this study, we experimentally investigate the possibility of skin-friction drag reduction by series of transverse cavities in a turbulent boundary layer flow. The effects of cavity depth (d), cavity length (l) and cavity spacing (s) on the skin friction drag are examined in the range of $Re_{\theta}\;=\;4030\;{\sim}\;7360$, $d/{\theta}_0\;=\;0.13\;{\sim}1.03$, l/d = 1 ~ 4 and s/d = 5 ~ 20. We perform experiments for twenty different cavity geometries and directly measure total drag force using in-house force measurement system. In most cases, the skin friction drag is increased. At several cases, however, small drag reduction is obtained. The variation of the skin ftiction drag is more sensitive to the cavity length than to the cavity depth or cavity spacing, and drag is reduced at $s/l\;{\geq}\;10$ and $l/{\theta}_0\;{\leq}\;0.26$ irrespective of the cavity depth. At $l/\bar{\theta}_0\;=\;0.13$ and s/l = 10, maximum 2% drag reduction is achieved. When the skin friction drag is reduced, there is little interaction between the flows inside and outside cavity, and the flow changed by the cavity is rapidly recovered at the following crest. A stable vortex is formed inside a cavity in the case of drag reduction. This vortex generates negative skin friction drag at the cavity bottom wall. Although there is form drag due to the cavity itself, total drag is reduced due to the negative skin friction drag.

  • PDF

투습방수의류의 착용쾌적성 평가 (Assessment of Wear Comfort of Water-vapor-permeable (WVP) garments)

  • 강인형;박효숙;이한섭
    • 한국의류학회지
    • /
    • 제36권9호
    • /
    • pp.928-939
    • /
    • 2012
  • This study evaluates wear comforts of water-vapor-permeable (WVP) garments through a measurement of various parameters such as skin and rectal temperatures, microclimate between skin and clothing, sweat rate, and subjective sensations (thermal, wet and comfort sensations) to correlate the physiological responses of the human body with its comfort feeling. Wear comfort during a specific exercise on a treadmill in a climatic chamber (temperature T = $20{\pm}0.5^{\circ}C$ and relative humidity H = $50{\pm}10%$) were studied using eight men wearing seven sportswear outfits (a long sleeve shirts and a long pants) made with seven different WVP fabrics. A comfort sensation was found to be highly correlated with skin T (p<.001), microclimate (T and H) between skin and clothing (p<.001) and sweat rate (p<.05). A regression model correlating comfort sensations and physiological responses obtained from wearer trials could be established: Y = 14.167 - 0.362 ${\times}$ X1 + 0.424 ${\times}$ X2 - 0.238 ${\times}$ X3 - 0.561 ${\times}$ X4 + 0.253 ${\times}$ X5 + 0.214 ${\times}$ X6 - 0.393 ${\times}$ X7 + 0.023 ${\times}$ X8 - 0.043 ${\times}$ X9. (Y = comfort sensation, X1 = forehead skin T, X2 = forearm skin T, X3 = hand skin T, X4 = thigh skin T, X5 = T of chest microclimate, X6 = T of thigh microclimate, X7 = chest sweat rate, X8 = H of back microclimate, X9 = H of thigh microclimate. The regression model obtained in this work can be used by manufacturers to objectively estimate the comfort sensation of sportswear before it is introduced to the consumer market. This study provides salient information to sportswear manufacturers and sportswear consumers.