• Title/Summary/Keyword: skin depth

Search Result 371, Processing Time 0.038 seconds

Microwave Properties of Ag Conducting Paste with Various Preparation Conditions (Ag가 함유된 전도성 도료의 제조 조건에 따른 고주파 특성)

  • Park, Sang-Hoon;Kim, Jeong-Pyo;Seong, Won-Mo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.9
    • /
    • pp.827-832
    • /
    • 2005
  • Dual band internal antennas were fabricated with Ag conducting paste of various preparation conditions and different print thickness by silk screen print. We have investigated microwave properties were compared Ag conducting paste antenna with copperplate antenna at 800 MHz and 1,800 MHz. Gain of Ag conducting paste antenna was improved when preparation conditions were the single size Ag particle, using dry type resin and high Ag containing percent. However, it was lower than that of copperplate antenna within $0.1\~2.0dBi$ at 800MHz. In addition, it was improved at 800MHz when thickness of Ag conducting paste was printed more than skin depth but it was held after critical print thickness. On the other hand, it was reached level of copperplate antenna at 1,800MHz.

Skin Region Extraction Combining 3D Depth and Color Features (3차원 거리와 색상 특징을 결합한 피부영역 추출)

  • Jang, Seok-Woo;Park, Young-Jae;Kim, Gye-Young;Lee, Suk-Yun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2012.01a
    • /
    • pp.201-204
    • /
    • 2012
  • 본 논문에서는 입력되는 스테레오 영상으로부터 3차원의 깊이 특징과 색상 특징을 결합하여 피부색상 영역을 보다 정확하게 검출하는 방법을 제안한다. 본 논문에서 제안된 방법은 우선 스테레오 정합 기법을 이용하여 좌우 영상으로부터 3차원의 깊이 특징을 추출한다. 그런 다음, 유사한 깊이 특징을 가지는 영역을 그룹화하고, 그룹화된 영역 중에서 피부색상을 나타내는 영역을 실제 피부영역이라고 판단한다. 실험에서는 2차원 위주의 기존의 피부영역 추출 방법과 제안된 방법의 성능을 정확도 측면에서 평가하였다. 결과적으로 제안된 방법은 3차원의 깊이 정보와 색상 정보를 효과적으로 결합함으로써 배경 영역에서 부정확하게 검출되는 피부영역 추출 오류를 상당수 제거하는 효과를 가진다.

  • PDF

Dual Laser Beam Joining Process for Polymers in Automotive Applications to Reduce Weights (차량경량화를 위한 듀얼 레이저 에너지 플라스틱 접합의 응용)

  • Han, Sang Bae;Choi, Hae Woon
    • Journal of Welding and Joining
    • /
    • v.31 no.4
    • /
    • pp.23-27
    • /
    • 2013
  • Laser heat source was used for automotive interior and exterior parts to reduce weights. Typically, 900's nm wavelength of laser has been widely used for polymer joining, however, the transmittance of the laser beam thorough clear polymers such as PMMA or PC has been an issue to overcome. To solve this issue, 1,940nm laser was applied on the clear polymer for the better absorption and 900nm laser beam was used for main laser for the joining. Conventional Gaussian or Elliptical heat source approximation has limitation in polymer which had deeper skin depth where major laser beam absorbs. To accurately simulate the physical laser beam absorption and joining optical properties were experimentally measured for the computer FEM simulation. The simulation results showed close correlation between theoretical and experimental results. The developed laser process is expected to increase productivity and gap closing which can cause failure of joining in laser material processing.

Skin Thickness of the Anterior, Anteromedial, and Anterolateral Thigh: A Cadaveric Study for Split-Skin Graft Donor Sites

  • Chan, Jeffrey C.Y.;Ward, John;Quondamatteo, Fabio;Dockery, Peter;Kelly, John L.
    • Archives of Plastic Surgery
    • /
    • v.41 no.6
    • /
    • pp.673-678
    • /
    • 2014
  • Background The depth of graft harvest and the residual dermis available for reepithelization primarily influence the healing of split-skin graft donor sites. When the thigh region is chosen, the authors hypothesize based on thickness measurements that the anterolateral region is the optimal donor site. Methods Full-thickness skin specimens were sampled from the anteromedial, anterior, and anterolateral regions of human cadavers. Skin specimens were cut perpendicularly with a custom-made precision apparatus to avoid the overestimation of thickness measurements. The combined epidermal and dermal thicknesses (overall skin thickness) were measured using a digital calliper. The specimens were histologically stained to visualize their basement membrane, and microscopy images were captured. Since the epidermal thickness varies across the specimen, a stereological method was used to eliminate observer bias. Results Epidermal thickness represented 2.5% to 9.9% of the overall skin thickness. There was a significant difference in epidermal thickness from one region to another (P<0.05). The anterolateral thigh region had the most consistent and highest mean epidermal thickness ($60{\pm}3.2{\mu}m$). We observed that overall skin thickness increased laterally from the anteromedial region to the anterior and anterolateral regions of the thigh. The overall skin thickness measured $1,032{\pm}435{\mu}m$ in the anteromedial region compared to $1,220{\pm}257{\mu}m$ in the anterolateral region. Conclusions Based on skin thickness measurements, the anterolateral thigh had the thickest epidermal and dermal layers. We suggest that the anterolateral thigh region is the optimal donor site for split-skin graft harvests from the thigh.

A Study on the Skin Improvement Effect of Microneedle Therapy Treatment and Application of Placenta Extract on the Treatment Area (미세다륜침 자극과 자극부위에 시행된 자하거추출물 도포에 의한 피부개선 효과연구)

  • Jin Suk Koo
    • The Korea Journal of Herbology
    • /
    • v.39 no.3
    • /
    • pp.1-9
    • /
    • 2024
  • Objectives : The purpose of this study was to find out the efficacy of placenta on the skin by comparing the difference effect between only MTS (microneedle therapy system) and the placenta extract application after MTS treatment. Methods : The present author performed once a week and total 4 times of MTS treatment. The treatment time took about 5~10 minutes and the depth of the needle was adjusted according to the participant's skin condition. One week after each treatment, the change of skin condition was measured. Two weeks after the end of the clinical trial, the skin condition was checked again. Results : In the case of moisture and elasticity, significant increases were observed in both the experimental and control groups. In the experimental group, skin temperature significantly decreased one week after the second treatment, and pore size significantly increased one week after the third treatment. In the case of skin tone, there was a significant temporary decrease after the first treatment in the control group, and in the experimental group, the skin tone showed a total decrease. Conclusion : When placenta extract was applied after MTS, skin temperature decreased and pores enlarged in the second and third treatments, and side effects such as rash and itchiness appeared. The final result showed a significant increase in skin moisture and elasticity. When animal-based ingredients containing high fat content are applied to the skin, the effect on the skin is good, but hypersensitivity reactions may occur, so use them with caution.

Current Distribution and Skin Effect in the Rail of an Electromagnetic Railgun. (전자레일건 래일에서의 전류분포 및 표피효과)

  • 임달호;구태만
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.36 no.12
    • /
    • pp.848-855
    • /
    • 1987
  • The currents in the rails of an electromagnetic railgun are concentrated in a near surface region. In order to understand this phenomenon, this paper deals with computation of the current distribution related to skin effect in a railgun. An analytical solution is obtained for a twodimensional model. It is found that current concentration at the interface between the rails and the armature is affected by the velocity, length and conductivity of the armature, that skin effect in the rails is affected by the relative velocity between the rails and the armature rather than other factors, and that skin depth in the rails is inversely proportional nearly to the square root of the velocity.

  • PDF

EFFECT OF ANTIOXIDANT ON THE STABILITY AND EFFICACY ON ANTI-WRINKLE OF INDOLE-3-ACETIC ACID

  • H. S. Jung;Park, Y. H.;Kim, J. H.;Park, K. H.;J. S. Koh;Kim, E. J.
    • Proceedings of the SCSK Conference
    • /
    • 2003.09a
    • /
    • pp.617-629
    • /
    • 2003
  • A recent development in cosmetics has been the pursuit of wrinkling in the skin. The cosmetics composed of anti-wrinkle agent stand out from the point of view of environmental contamination and pollution. Among them, Indole-3-acetic acid (IAA), studied with wrinkling pigmentation and swelling conditions in the area of the eye, showed clinically significant reduction in depth of lines during one month trial using skin treatment. But, IAA has shown some problems when used in cosmetic formulations, such as stability, permeability and toxicity. The results of the clinical examination were shown that its permeability and toxicity didn't matter. To increase the stability of IAA, antioxidants such as Licorice, ubiquinone, tocopherol, Baicalin, ferulic acid, BHT, ascorbic acid, sodium metabisulfite, and so on were employed in cosmetic formulations. Our main purpose is the study for the stability efficiency and effect of each other of cream formulations containing optimal dosage antioxidants (o/w type emulsion), This study evaluated wrinkle reduction effect of IAA, which is used in cosmetics.

  • PDF

Principle and Mechanism of Double Eyelid Formation

  • Inchang Cho
    • Archives of Plastic Surgery
    • /
    • v.50 no.2
    • /
    • pp.142-147
    • /
    • 2023
  • Some of Asian eyelids have double fold and some do not. Many people tend to prefer double eyelid in aesthetic and functional reasons. Since the mechanism of double eyelid is bonding the eyelid skin to the eye-opening tissue, the principle of double eyelid surgery is also connecting the eyelid skin to levator component. Double eyelids are differentiated by their shape according to the height and curvature. The double eyelid surgery procedure is divided into incision method and nonincision method. And the incision method is subdivided into double fold line design, skin and oculi muscle incision or excision, pretarsal or preaponeurotic soft tissue excision, fixation of posterior lamella to anterior lamella, and skin suture. The nonincision method is to connect the posterior lamella and the anterior lamella as a thread only without an incision. A successful double eyelid surgery creates a fold well-balanced in height, curvature, and depth of the fold based on patient's preference. In this article, the author's own methods of performing surgery are described, with a step-by-step guide and surgical tips.

The Multiple V-Y Advancement Modification for the Surgical Correction of Cryptotia

  • Nguyen Quang Duc;Nguyen Phuong Tien
    • Archives of Plastic Surgery
    • /
    • v.50 no.1
    • /
    • pp.26-29
    • /
    • 2023
  • Cryptotia is a rare congenital auricular deformity among Caucasians but more common in Asians. Various operative techniques have been described, such as skin graft, V-Y plasty, Z plasty, and islands skin flap. Among those techniques, V-Y plasty has many advantages and is indicated for severe cases. However, several problems remain when this method is adopted, such as conspicuous scars and lowered hairline. To overcome these problems, the authors have developed a new technique, multiple V-Y advancement modification, which stitches the skin flaps together to a tight, discrete central focal point. This technique has the advantage of hiding scars behind the earlobe, providing enough skin for the deformed areas, minimizing the condition of the hairline being lowered and auriculocephalic sulcus depth.

Design of Pile Foundations in Soft Deposits (연약지반에서의 말뚝기초의 설계)

  • Kim, Ju-Hyong;Kwon, Oh-Sung;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.49-56
    • /
    • 2005
  • The negative skin friction on piles, which are installed in currently consolidating soft deposits, creates significant problems on the stability of pile foundations. This study investigated whether or not the pile foundation designs were appropriate in soft deposits with large amount of consolidation settlement. The final settlements of the grounds along the pile depth were estimated by the soil parameters obtained from the laboratory tests and by the field-measured settlement curves, if they were available. The displacement of the piles along the pile depth was estimated by both the load transfer method and the numerical method. Both methods gave similar locations of neutral points and magnitudes of the maximum axial forces. The movements of the ground and the piles were compared to calculate the down drag acting on piles. For the piles whose bearing capacities were less than the design loads including the down drag, slip layer coatings and/or incrementing of the penetration depth into the bearing stratum were proposed to improve the piles capacities.

  • PDF