• Title/Summary/Keyword: skin/core

Search Result 225, Processing Time 0.026 seconds

Synthesis of FDR-SPC Resin and PIV Measurement for Frictional Drag-reduction (마찰저항 저감을 위한 고분자 수지 합성 및 PIV 유동장 계측)

  • Chung, Sungwoo;Kim, Eunyoung;Chun, Ho Hwan;Park, Hyun;Lee, Inwon
    • Journal of the Korean Society of Visualization
    • /
    • v.12 no.1
    • /
    • pp.49-53
    • /
    • 2014
  • In this study, a novel FDR-SPC is first synthesized in this study. The drag reducing functional radical such as PEGMA (Poly(ethylene) glycol methacrylate) has been utilized to participate in the synthesis process of the SPC. The types of the baseline SPC monomers, the molecular weight and the mole fraction of PEGMA were varied in the synthesis process. The resulting SPCs were coated to the substrate plates for the subsequent hydrodynamic test for skin friction measurement. In a low-Reynolds number flow measurement using PIV (Particle Image Velocimeter), a significant reduction in Reynolds stress was observed in a range of specimen, with the maximum drag reduction being 15.9% relative to the smooth surface.

Analytical, numerical and experimental investigation of low velocity impact response of laminated composite sandwich plates using extended high order sandwich panel theory

  • Salami, Sattar Jedari;Dariushi, Soheil
    • Structural Engineering and Mechanics
    • /
    • v.68 no.3
    • /
    • pp.325-334
    • /
    • 2018
  • The Nonlinear dynamic response of a sandwich plate subjected to the low velocity impact is theoretically and experimentally investigated. The Hertz law between the impactor and the plate is taken into account. Using the Extended High Order Sandwich Panel Theory (EHSAPT) and the Ritz energy method, the governing equations are derived. The skins follow the Third order shear deformation theory (TSDT) that has hitherto not reported in conventional EHSAPT. Besides, the three dimensional elasticity is used for the core. The nonlinear Von Karman relations for strains of skins and the core are adopted. Time domain solution of such equations is extracted by means of the well-known fourth-order Runge-Kutta method. The effects of core-to-skin thickness ratio, initial velocity of the impactor, the impactor mass and position of the impactor are studied in detail. It is found that these parameters play significant role in the impact force and dynamic response of the sandwich plate. Finally, some low velocity impact tests have been carried out by Drop Hammer Testing Machine. The results are compared with experimental data acquired by impact testing on sandwich plates as well as the results of finite element simulation.

Development of the Lightweight Multi-layered Board with High Stiffness for Automotive Interior Trims (자동차 내장트림용 고강성 경량 다층보드 개발)

  • Lee, Kyu-Se;Lee, Kyung-Sick
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • Lightweight multi-layered boards with high stiffness for the automotive interior trims were developed, which were composed of a single material. The boards were constructed in the form of substrate/core/substrate with newly developed materials. The materials which have high tensile strength and elongation were selected for the substrate materials, and those which have high compressive strength and low density were selected for the core materials. 25 types of multi-layered boards were fabricated using the selected substrate and core materials. The compatibility with the skin materials, the formability and the tensile strength and flexural strength of the specimens were evaluated. The results show that three types of multi-layered boards(Kenboard/EPP foam/Kenboard, Twintex/PP honeycomb/Twintex, Curv sheet/EPP foam/Curv sheet) are appropriate for the automotive interior trims. Considering the ease of materials supply and the economical aspect, Kenboard/EPP foam/Kenboard is thought to be the most realistic alternative.

Mercerization of Cotton Fabric in degassed NaOH solution (용존기체성분을 제거한 NaOH수용액에서의 면직물의 Mercerization)

  • 김승일;이의소;김채진
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2001.10a
    • /
    • pp.51-54
    • /
    • 2001
  • Mercerization은 대부분의 면제품에 널리 적용되고 있는 가공방법이나 일반적으로 이루어지고 있는 상온에서의 NaOH에 의한 mercerization은 용액의 표면장력과 점도 때문에 알칼리가 섬유내부까지 깊숙이 침투하지 못하고 이로 인해 섬유의 표면에만 Mercerization이 진행되어 태가 뻣뻣해지는 단점이 있다. 이러한 jamming effect에 의한 표면(skin)과 내부(core)간의 머서화차이를 제거하기 위하여 고온 머서화가공에 대한 연구가 진행된 바 있으나 에너지의 과다소비라는 측면에서 상업화되기에는 문제가 있는 실정이다. (중략)

  • PDF

A Study on the Disbonding Detection of Al/Al Honeycomb Sandwich Structures by Ultrasonic Methods (초음파를 이용한 Al/Al 하니캄 구조물의 Disbonding 검출에 관한 연구)

  • Cho, K.S.;Lee, J.S.;Chang, H.K.;Lee, S.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 1990
  • In this study the disbonding tests of adhesively bonded Al/Al honeycomb structures were performed by ultrasonic methods. Ultrasonic C-scan squiter method and ultrasonic surface wave attenuation measuring method were applied for the detection of skin/core disbonding. The bonding quality of Al/Al honeycomb structures could be well evaluated by properly controlled ultrasonic parameters.

  • PDF

The Influence of the Direction of Applied Load(Compression and Uplift) and the Diameter of the Pile on the Pile Bearing Capacity (하중 작용 방향(압축과 인발)과 말뚝의 직경이 말뚝 지지력에 미치는 영향)

  • 이명환;윤성진
    • Geotechnical Engineering
    • /
    • v.7 no.3
    • /
    • pp.51-64
    • /
    • 1991
  • The reliable estimation of pile bearing capacity is essential for the improvement of the re- liability and the cost-effectiveness of the design. There have been numerous pile bearing capacity prediction methods proposed up to now, however, execpt for the estimation made from the result of the pile loading test, not one method is appropriate for the reliable prediction. Due to the considerable time and expenses required to carry out the pile loading test, the test has seldom been utilized. The development of Simple Pile Loading Test(SPLT) which utilizes the pile skin friction as the required reaction force to cause the pile tip settlement, provides a solution to perform more pile loading tests and consequently a more economical pile design is possible. The separate measurement of skin friction and tip resistance during the course of performing SPLT provides a better understanding of the pile behavior than the result of the conventional pile loading test where only the total resistance is measured. On the other hand, there are some points to be clarified in order to apply the test results of SPLT to practical problem. They are the direction of the applied load to mobilize the skin friction and the use of reduced sized sliding core. In this research, both the SPLT and the conventional pile loading test on 406mm diameter steel pipe pile have been performed. From the result, it would be safe to use the measured SPLT skin friction value directly in the design, since the value is somewhat lower than the value measured in the conventional test. It is further assumed that the tip resistance value of the reduced sized sliding core should properly be analysed by taking the incluonce of scale effect into consideration.

  • PDF

Eutectic structure evolution of Al2O3-ZrO2-Y2O3 system for apotential hybrid solar cell application

  • Han, Young-Hwan;Yun, Jon-Do;Harada, Yohei;Jeong, Young-Keun;Makino, Taro;Kim, Kwang-Ho;Kwon, Se-Hun;Kim, Young-Moon;Kakegawa, Kazuyuki
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2009.11a
    • /
    • pp.11.1-11.1
    • /
    • 2009
  • Ternary Al2O3.ZrO2.Y2O3 samples with a eutecticcomposition were prepared by slow cooling. The microstructural evolution wasobserved with X-ray diffraction (XRD), scanning electron microscopy (SEM). TheSEM observation of the ternary samples agreed with the XRD with a completion ofcrystallisation by slow cooling. The target materials commonly have 'cantaloupe skin' microstructures as shown inthe previous studies by Han et al. The nanocomposite may have experienceddifferent cooling rates with two different microstructures, near the surfacehaving experienced optimal conditions for the eutectic reaction during theircooling and thus formed the eutectic microstructure, near the centre havingexperienced a slower cooling rate. The crystallised eutectic ternary Al2O3.ZrO2.Y2O3 system had three different phaseswith a 3Y2O3. 5Al2O3 (yttrium.aluminiumgarnet phase), an alumina phase formed by the eutectic reaction, and a solidsolution of ZrO2 and Y2O3.

  • PDF

Factors influencing the bio-impedance data in tissue segments along the three arm meridians: a pilot study

  • Lim, Chi Eung Danforn;Wong, Felix Wu Shun;Smith, Warren
    • CELLMED
    • /
    • v.1 no.1
    • /
    • pp.7.1-7.9
    • /
    • 2011
  • Bioelectric impedance measurements have been reported to show significant variation between individuals. Different physiological conditions like thickened skin, obesity, and fluid retention can affect the impedance measurement. Therefore, it is important to learn what other factors can affect the measurements of impedance even in healthy individuals. Such information is a prerequisite for understanding the changes in impedance associated with acupuncture treatment. This study investigated the bio-impedance properties of tissue segments in the arms of a number of healthy subjects, so as to define the factors that might influence the variation of the bio-impedance data in acupuncture meridians studies. 51 healthy subjects were recruited through Liverpool Hospital, Sydney. Demographic data was collected from each subject including the age, sex, BMI, and time since most recent meal. Electrodes were applied to the forearms of each test subject. Measurements were done by a purpose-built Bio-Impedance Research Device (BIRD-I) which allowed the determination of core resistance (Rc) and core reactance (Xc) of each of the three meridian tissue segments on the anterior surface of the forearm. No significant difference was found in the core resistance attributable to age group, gender, BMI or meal intake. However, a statistically significant trend in increasing resistance from the radial to ulnar aspect of the forearm (p < 0.001) was found. No significant difference was found in the core resistance of test tissue segments among the 51 healthy subjects measured in this study. However, the trend of increasing core resistance from the radial to ulnar aspects of the arm deserves further investigation.

Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature (손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정)

  • Jun, Min-Ho;Jeon, Young Ju;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.141-147
    • /
    • 2017
  • A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperature sensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuring pulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at $35^{\circ}C$ (the maximum wrist temperature), the device was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sensor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during temperature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect to thickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the compensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.