• Title/Summary/Keyword: size reduction factor

Search Result 236, Processing Time 0.031 seconds

MP3 Encoder Chip Design Based on HW/SW Co-Design (하드웨어 소프트웨어 Co-Design을 통한 MP3 부호화 칩 설계)

  • Park Jong-In;Park Ju Sung;Kim Tae-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.25 no.2
    • /
    • pp.61-71
    • /
    • 2006
  • An MP3 encoder chip has been designed and fabricated with the hardware and software co-design concepts. In the aspect of the software. the calculation cycles of the distortion control loop. which requires most of the calculation cycles in MP3 encoding procedure. have been reduced to $67\%$ of the original algorithm through the 'scale factor Pre-calculation'. By using a floating Point 32 bit DSP core and designing the FFT block with the hardware. we can get the additional reduction of the calculation cycles in addition to the software optimization. The designed chip has been verified using HW emulation and fabricated via 0.25um CMOS technology The fabricated chip has the size of $6.2{\time}6.2mm^2$ and operates normally on the test board in the qualitative and quantitative aspect.

The Anti-Obesity Activity of Syzygium aromaticum L. in High-Fat Diet-induced Obese Mice (고지방식이로 유도된 비만 마우스에서 정향(丁香)의 항비만 효과)

  • Hui Yeon An;Seong-Soo Roh;Mi-Rae Shin
    • The Korea Journal of Herbology
    • /
    • v.39 no.1
    • /
    • pp.11-21
    • /
    • 2024
  • Objectives : This study aims to analyze the anti-obesity effect of Syzygium aromaticum L. (SA) in obese mice made by a 60% high-fat diet (HFD). Methods : The antioxidant activities of SA were evaluated in vitro. To assess the anti-obesity effect of SA, male C57BL/6 mice were divided into five groups: Normal, Control, GC100 (Garcinia cambogia 100 mg/kg/day), SA100 (SA 100 mg/kg/day), SA200 (SA 200 mg/kg/day). All groups underwent a 6-week regimen of HFD and oral administration, except for the Normal group. Subsequently, we performed blood analysis, western blotting, and histopathological staining. Results : SA demonstrated effectiveness in antioxidant measurements. SA treatment resulted in a significant decrease in body weight gain, along with reductions in liver and epididymal fat weights. Serum triglyceride (TG), total cholesterol (TC), glutamic oxaloacetic transaminase (GOT), glutamic pyruvic transaminase (GPT), and leptin levels were reduced with SA treatment. Moreover, in the SA100 group, the reduction of both TG and TC synthesis was caused by inhibiting the sterol regulatory element-binding transcription factor 1 (SREBP-1) and sterol regulatory element-binding transcription factor 2 (SREBP-2) through the Sirtuin 1 (Sirt1)/phospho-AMP-activated protein kinase (p-AMPK) pathway. Furthermore, SA treatment at a dose of 100 mg/kg reduced the accumulation of lipid droplets in the liver and the adipocyte size of the epididymal fat. Conclusion : Our research reveals the anti-obesity effects of SA by demonstrating its ability to inhibit body weight gain and lipid accumulation, suggesting that SA might be promising for obesity treatment.

Characterization of Weathered Zone bearing Corestones through Scale Model Test (실내모형실험에 의한 핵석 풍화대 지반 특성 산정)

  • Woo, Ik
    • The Journal of Engineering Geology
    • /
    • v.17 no.3
    • /
    • pp.435-443
    • /
    • 2007
  • This study shows the prediction of the engineering properties of weathered zone bearing corestones through the engineering geological surveys and the scale model test in the laboratory. The window survey and the observation on the borehole core were peformed on three natural slopes in corestones area in order to analyse the distribution pattern and the geometrical properties of corestones. Natural corestones were crushed and abrased for the scale model test into less than 5 mm in maximum-2mm in average by the scale reduction ratio based on the size of natural corestones and the specimen size. Scale model tests were carried out on soil and plaster model specimens with different corestone content ratio - 0%, 10%, 20%. The direct shear test on soils shows that shear strength is increased by the increase of corestone content ratio. The increase of cohesion is, however, more important factor to the shear strength of soil for 20% corestone content ratio due to interlocking of crushed corestone particles. The plaster model test shows a tendance of increase of UCS and modulus of elasticity with increase of corestone content. The variation ratio of specimen property by change of corestone content ratio in plaster model test was applied to in situ properties in order to estimate the properties of weathered zone bearing corestones. So it could be predicted that the increase of corestone content to 10% and to 20% produce about 18% and 30% UCS's increase respectively.

The characteristics of bismuth magnesium niobate multi layers deposited by sputtering at room temperature for appling to embedded capacitor (임베디드 커패시터로의 응용을 위해 상온에서 RF 스퍼터링법에 의한 증착된 bismuth magnesium niobate 다층 박막의 특성평가)

  • Ahn, Jun-Ku;Cho, Hyun-Jin;Ryu, Taek-Hee;Park, Kyung-Woo;Cuong, Nguyen Duy;Hur, Sung-Gi;Seong, Nak-Jin;Yoon, Soon-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.62-62
    • /
    • 2008
  • As micro-system move toward higher speed and miniaturization, requirements for embedding the passive components into printed circuit boards (PCBs) grow consistently. They should be fabricated in smaller size with maintaining and even improving the overall performance. Miniaturization potential steps from the replacement of surface-mount components and the subsequent reduction of the required wiring-board real estate. Among the embedded passive components, capacitors are most widely studied because they are the major components in terms of size and number. Embedding of passive components such as capacitors into polymer-based PCB is becoming an important strategy for electronics miniaturization, device reliability, and manufacturing cost reduction Now days, the dielectric films deposited directly on the polymer substrate are also studied widely. The processing temperature below $200^{\circ}C$ is required for polymer substrates. For a low temperature deposition, bismuth-based pyrochlore materials are known as promising candidate for capacitor $B_2Mg_{2/3}Nb_{4/3}O_7$ ($B_2MN$) multi layers were deposited on Pt/$TiO_2/SiO_2$/Si substrates by radio frequency magnetron sputtering system at room temperature. The physical and structural properties of them are investigated by SEM, AFM, TEM, XPS. The dielectric properties of MIM structured capacitors were evaluated by impedance analyzer (Agilent HP4194A). The leakage current characteristics of MIM structured capacitor were measured by semiconductor parameter analysis (Agilent HP4145B). 200 nm-thick $B_2MN$ muti layer were deposited at room temperature had capacitance density about $1{\mu}F/cm^2$ at 100kHz, dissipation factor of < 1% and dielectric constant of > 100 at 100kHz.

  • PDF

Mixed Noise Reduction Filters for CR Images (CR X선 영상의 복합잡음 감소에 관한 연구)

  • Min, Jung-Whan;Jeong, Hea-Won;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.30 no.1
    • /
    • pp.1-6
    • /
    • 2007
  • This study is to decrease compound noise in x-ray films. This study compared Signal to noise ratio(SNR), Peak signal to noise ratio(PSNR), Mean square error(MSE) to surface of the earth. In addition, we evaluated noise elimination effect according to the kernel size of Median filter. This experiments show that some filters are useful by finding image that is near in circle image comparing circle picture with each processed picture. In noise power value, when cutoff frequency was compared with other filters of cutoff frequency. Cutoff frequency of $2/3\pi{\sim}3/4\pi$ is good and it shows good SNR and PSNR. Therefore, it can display high filter effect. As Median Filter's Kernel size grows SNR value gets bigger, which shows better filter effect. Most pictures are distorted after filter application in medical treatment image. It is important to keep spatial resolution in most medical images. Visual estimation as well as quantitative indicators should be necessary for a better image.

  • PDF

Sensitivity analysis of RPLS inventory model with price dependent demand linearly under order-size-dependent delay in payments in a two-stage supply chain (주문량에 따라 종속적으로 외상거래기간이 허용되는 상황 하에 선형수요함수를 고려한 RPLS 재고모형의 퇴화율에 따른 민감도분석)

  • Shinn, Seong-Whan
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.577-582
    • /
    • 2022
  • Credit transactions are used as a means of price discrimination from competitors in order for suppliers to increase customer demand. In particular, in the case of a two-stage supply chain consisting of a supplier, a retailer, and a customer, the deferral of payment for goods allowed by the supplier is a means of reducing the inventory investment cost of the retailer. Retailers have the opportunity to discount the selling price while anticipating an increase in end-customer demand through the reduction of the inventory investment cost. In view of the fact that such trade credit is provided for the purpose of increasing demand as a means of discrimination from competitors, it may be more general that the credit transaction period is allowed flexibly according to the transaction volume. In particular, in the case of deteriorating products, the credit transaction period given according to the order volume is a factor that increases the order volume of the retailer, but product deterioration can be a limiting factor in the increase in the order volume. The deterioration rate actually plays an important role in determining the inventory policy of the retailer. Therefore, in this paper, the effect of such deterioration rate on the inventory policy of retailer is analyzed.

A Study on Improving Scheme and An Investigation into the Actual Condition about Components of Physical Distribution System (물류시스템 구성요인에 관한 실태분석과 개선방안에 관한 연구)

  • Kim, Kyeong-Cho
    • Journal of Distribution Science
    • /
    • v.7 no.4
    • /
    • pp.47-56
    • /
    • 2009
  • The purpose of this study is to present an alternative improving the efficient and reasonable of the physical distribution system management is influenced by many factors. Therefore, the study depends on the documentary method and survey method to achieve the purpose of this study. The major components of a physical distribution system are refers to as elements, include warehouse·storage system, transportation system, inventory system, physical distribution information system. The factors used in this study are ① factor of product(quality·A/S·added value of product·adaption of product·technical competitive power to other enterprises), ② factor of market(market channel·kinds of customer·physical distribution share), ③ factor of warehouse·storage(warehouse design·size·direction·storage ability·warehouse quality), ④ factor of transportation(promptness·reliability·responsibility·kinds of transportation·cooperation united transportation system·national transportation network), ⑤ factor of packaging (packaging design·material·educating program·pollution degree measure program), ⑥ factor of inventory(ordinary inventory criterion·consistence for inventories record), ⑦ factor of unloaded(unloaded machine·having machine ratio), ⑧ factor of information system (physical distribution quantity analysis·usable computer part), ⑨ factor of physical distribution cost(sales ratio to product) ⑩ factor of physical distribution system(physical distribution center etc). The implication of this study can be summarized as follows: ① In firms that have not adopted a systems integrative approach, physical distribution is a fragmented and often uncoordinated set of activities spread throughout various functions with function having its own set of priorities and measurements. ② The physical distribution is recognized as more an important strategic factor than a simple cost reduction factor, ③ It can be used a strategic competition tool to enterprise.

  • PDF

Effect of Pretreatment Process on Hybrid Membrane Filtration Performance (원수의 물리.화학적 특성에 따른 막 분리 공정의 전처리 공정 적용성 평가)

  • Jung, Chul-Woo;Son, Hee-Jong;Bae, Sang-Dae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.6
    • /
    • pp.613-619
    • /
    • 2006
  • The objectives of this research are to evaluate the effect of membrane materials, particulate matter and membrane pore size on permeate flux. It was shown that the removal efficiency of high MW organic matter more than 10 kDa was lower than that of low MW organic matter for $MIEX^{(R)}$ process. For the change of permeate flux by the pretreatment process, $MIEX^{(R)}+UF$ process showed high removal efficiency of organic matter as compared with coagulation+UF processes, but high reduction rate of permeate flux was presented through the reduction of removal efficiency of high MW organic matter. The pretreatment of the raw water significantly reduced the fouling of the hydrophilic membrane, but did not decrease the flux reduction of the hydrophobic membrane. Flux decline on MF process increased due to the pore clogging, while the permeate flux decline of UF process decreased due to the formation of cake layer. It was shown that particle matter was not effect on MIEX+membrane process. But, for coagulation+membrane process, particle matter was important factor on permeate flux.

Experimental Study on the Slip Coefficient with Member Type and Dimensions of High Tension Bolt Hole (부재 및 고장력볼트 구멍치수에 따른 미끄러짐계수의 실험적 연구)

  • Yang, Seung-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.4277-4283
    • /
    • 2012
  • Slip coefficient, whose value is dependent on the condition of contact surface at the friction joint of high tension bolt, is determined by slip load. Because contact area affects slip load, contact area that varies with bolt hole size is also related to the slip coefficient. In this study, we manufactured 32 specimens and performed bending and tension tests in order to examine changes in slip coefficient and load with material type, bolt diameter, and size of bolt hole. Slip load of specimens with oversize bolt hole had strength that was more than 80% higher than the slip load of specimens with standard bolt hole, and it also exceeded the design slip strength. In addition, we observed significant correlation between net-section ratio and slip ratio of specimens with oversize and standard bolt hole. However, some differences between the specimens are thought to have been caused by reduction in initial axial force of high tension bolt, which is an important parameter of slip coefficient. It is self-evident that increased bolt hole size would lead to decrease in design strength as it reduces both slip coefficient and bolt axial force. Nevertheless, we suggest that some flexibility in regulation of bolt hole, as long as it does not threaten the structural stability, may be a positive factor in terms of workability and efficiency.

Recent Perspectives on Oncoplastic Breast Surgery in Korea (우리나라의 종양성형학적 유방암 수술에 대한 최신 동향)

  • Kang, Taewoo
    • Journal of Life Science
    • /
    • v.30 no.6
    • /
    • pp.563-569
    • /
    • 2020
  • Oncoplastic surgery (OPS) combines oncologically safe tumor resection with aesthetically satisfying reconstruction of defects using established plastic surgery techniques. OPS is characterized by initial excision as extensive as is beneficial for oncological safety, and, once sufficient resection is complete, displacement or replacement techniques are selected based on remnant volume. The size of the lesion and the individual patient are important factors when considering the appropriate approach, and when pre-operative imaging, including MRI, is used to determine the technique, the complete removal of cancer cells by permanent pathology is essential. A frozen section is used during the operation to reduce the reoperation rate, but it is difficult to cover the entire margin surface theoretically and even harder in practice. A recent report about adequate margins has empowered OPS in its oncological safety. Considering the patients to whom each modality could be applied, basic breast volume is an important factor, and this is influenced by ethnic differences. In Europe or the US, for example, the average breast size is 36D (600 ㎤) and reduction mammoplasty is predominantly used. However, the average size of patients in our institution is 33A (300 ㎤), and so quite different approaches are selected in most cases. New techniques involving radiofrequency and fluorescence have been proposed as safe and easily accessible ways of reducing complications.