• 제목/요약/키워드: size guidance tool

검색결과 10건 처리시간 0.024초

접촉 압력 분포를 이용한 최소 침습 수술을 위한 의료 촉진 가이던스 시스템 (A Medical Palpation Guidance System for Minimally Invasive Surgery using Contact Pressure Distribution)

  • 김형균;정완균
    • 센서학회지
    • /
    • 제26권4호
    • /
    • pp.266-273
    • /
    • 2017
  • In this research a medical palpation guidance system for minimally invasive surgery (MIS) is proposed. Palpation is a useful tool for identifying a size and location of a lump during a surgery. However, conventional manual palpation is only available in open surgery, so there has been several researches about palpation assistant or guidance system for MIS. The previously developed systems are based on a pressure based or stiffness based approach. These previous approaches have some limitations in increasing complexity of the systems and lack of geometric information about the lump which is more important information for the lump removal than the stiffness information. We propose a palpation guidance system using a novel approach using contact pressure distribution. Since our approach gives the geometry information of the lump as well as the existence information, the operator can easily notice the currently identified lump region and the optimal position for the next palpation. The experiment results show that our approach can offer the geometry information of the lump correctly.

온라인 의류 쇼핑 사이트의 제품 사이즈 정보 실태 분석 - 여성용 바지를 중심으로 - (Sizing Communications on Online Apparel Retail Websites - Focusing on Ready-to-Wear Women's Pants -)

  • 이아람;김희은
    • 한국의류산업학회지
    • /
    • 제24권1호
    • /
    • pp.117-126
    • /
    • 2022
  • This study aims to analyze the sizing information of women's ready-to-wear pants as indicated on online retail websites and to suggest better sizing communication that can assist customers in making successful apparel size selections. We gathered size specifications and size reference information for basic straight pants from 34 online apparel retail websites. Although the Korean standard recommends labeling the body dimension-based sizing code and specification, most websites preferred to use various types of sizing codes. Body measurements were only used by a few websites, and garment dimension descriptions were the most common method to indicate product size. Many websites provided size reference information through customer review boards and fit model images, however, there was insufficient body size information to allow customers to infer the fit of their body type. When using the size guidance tools, the major data input points were stature and weight measurements. However, the waist measurements of pants sizes guided only by stature and weight values revealed inconsistent ease allowance for corresponding body size populations, especially in the overweight group. Based on our findings, we propose a more effective method of communicating the size information of pants online. We expect that this will contribute to the efficiency of online apparel product display and build a better shopping environment that satisfies both sellers and consumers.

The Effects of Bronchoscope Diameter on the Diagnostic Yield of Transbronchial Lung Biopsy of Peripheral Pulmonary Nodules

  • Lee, Nakwon;Kim, Sang-Ha;Kwon, Woocheol;Lee, Myoung Kyu;Yong, Suk Joong;Shin, Kye Chul;Jung, Ye-Ryung;Choi, Yeun Seoung;Choi, Jiwon;Choi, Ji Sun;Lee, Won Yeon
    • Tuberculosis and Respiratory Diseases
    • /
    • 제77권6호
    • /
    • pp.251-257
    • /
    • 2014
  • Background: Transbronchial lung biopsy (TBLB) is a valuable diagnostic tool for peripheral pulmonary lesions. The diagnostic yield of TBLB reportedly ranges from 41%-60%. Many studies demonstrated the various factors that influence the yield of TBLB, including size, location, and distance from the carina or pleura. However, no study has evaluated the effects of the bronchoscope diameter. We evaluated whether the bronchoscope diameter affected the diagnostic yield of TBLB. Methods: We reviewed records from 178 patients who underwent TBLB using bronchoscopes of two different diameters (5.7 mm, thick outer diameter, Olympus BF-200; 4.9 mm, thin, BF-260). The fluoroscopic guidance rates, yield of TBLB and flexible bronchoscopy (FB) were compared between the two groups. Additionally, we compared the results of the procedures with respect to diagnosis, distance from the pleura, and size of the lesion. Results: The results of fluoroscopic guidance, TBLB, and FB yield using thin diameter bronchoscope were significantly better than those obtained with a thick diameter bronchoscope (p=0.021, p=0.036, and p=0.010, respectively). Particularly, when the distance from the pleura was ${\leq}10mm$, success rates for fluoroscopic guidance and FB with thin bronchoscope were higher (p=0.013 and p=0.033, respectively), as compared to with thick bronchoscope. Conclusion: A thinner diameter bronchoscope increased the yield of bronchoscopy, and bronchial washing in conjunction with TBLB was useful in the diagnosis of peripheral pulmonary nodules.

대학도서관의 목록이용행태의 일고찰 (A study of the searching behavior at the catalog in a university library : case study of Jeonbug national university library)

  • 강혜영
    • 한국도서관정보학회지
    • /
    • 제9권
    • /
    • pp.1-31
    • /
    • 1982
  • A library catalog is most important finding tool to a library collection. This tool should be so designed as to enable users to handle with ease and convenience. Library catalog use study is necessary in order to identify the demands made on the catalog by its actual users and to measure the adequacy with which the catalog is meeting these demands. Many major catalog use surveys were performed by means of questionnaire and interview, but these methods are so difficult and perverse that the results of catalog use studies might often be far from scientific precision. The aim of this paper is to seek the guidelines with which one might assist the catalogers in providing an effective library catalog for their patrons. In order to get the first-hand information an actual survey was undertaken on searching behavior at the catalog of Jeonbug National University Library from November 30 to December 5, 1981 and from May 17 to May 22, 1982. The results of the survey can be summarized as follows: 1. Most of the students (79.77%) use the library. 2. Most of the library patrons (74.52%) use the public catalog as the searching tool to the library collection. 3. 67.85% of the catalog users are interested in searching materials written in Korean, Japanese, and Chinese. 4. 72.86% of the catalog users are interested in searching known items at catalog. 5. In known item searching, 49.44% of the catalog users choose title entry. 6. 20.17% of the catalog users are interested subject searching at the catalog. 7. Reference card is not utilized in searching. 8. For the translated items users want double entries in both vernacular and Korean. 9. At current catalog description, author, title, call number, translator, publisher and joint author are useful entry. Edition, author's date of birth and death, illustrative, size of book and bibliographical notes are not much utilized. 10. 55.39% of the catalog user need systematic guidance on how to use the library catalog and collection.

  • PDF

토양미생물 생태 연구를 위한 증폭 파이로시퀀싱 기법의 응용 (Application of Amplicon Pyrosequencing in Soil Microbial Ecology)

  • 안재형;김병용;김대훈;송재경;원항연
    • 한국토양비료학회지
    • /
    • 제45권6호
    • /
    • pp.1073-1085
    • /
    • 2012
  • Soil microbial communities are immensely diverse and complex with respect to species richness and community size. These communities play essential roles in agricultural soil because they are responsible for most of the nutrient cycles in the soil and influence the plant diversity and productivity. However, the majority of these microbes remain uncharacterized because of poor culturability. Next-generation sequencing techniques have revolutionized many areas of biology by providing cheaper and faster alternatives to Sanger sequencing. Among them, amplicon pyrosequencing is a powerful tool developed by 454 Life Sciences for assessing the diversity of complex microbial communities by sequencing PCR products or amplicons. This review summarizes the current opinions in amplicon sequencing of soil microbial communities, and provides practical guidance and advice on sequence quality control, aligning, clustering, OTU- and taxon-based analysis. The last section of this article includes a few representative studies conducted using amplicon pyrosequencing.

선박용 대형 디젤 엔진 열 해석을 위한 CFD-FEM 연계 방법의 적용 (Application of CFD-FEM Coupling Methodology to Thermal Analysis on the Large-size Marine Diesel Engine)

  • 김한상;민경덕
    • 한국자동차공학회논문집
    • /
    • 제16권1호
    • /
    • pp.64-70
    • /
    • 2008
  • Temperatures of engine head and liner depend on many factors such as spray and combustion process, coolant passage flow and engine related structures. To estimate the temperature distribution of engine structure, multi-dimensional computational fluid dynamics (CFD) codes have been mainly adopted. In this case, it is of great importance to obtain the realistic wall temperature distribution of entire engine structure. In the present work, a CFD-FEM coupling methodology was presented to address this demand. This approach was applied to a real large-size marine diesel engine. CFD combustion and coolant flow simulations were coupled to FEM temperature analysis. Wall heat flux and wall temperature data were interfaced between combustion simulation and solid component temperature analysis via translator by a commercial CFD package named FIRE by AVL. Heat transfer coefficient and surface temperature data were exchanged and mapped between coolant flow simulation and FEM temperature analysis. Results indicate that there exists the optimum cell thickness near combustion chamber wall to reasonably predict the wall heat flux during combustion period. The present study also shows that the effect of cell refining on predicting in-cylinder pressure during combustion is negligible. Hence, the basic guidance on obtaining the wall heat flux needed for the reasonable CFD-FEM coupling analysis has been established. It is expected that this coupling methodology is a robust tool for practical engine design and can be applied to further assessment of the temperature distribution of other engine components.

백서 날문부에서 스텐트 유도 조직 과증식 형성을 위한 전임상 모델에 관한 연구 (A Rat Pylorus Stricture Model to Create Stent-induced Granulation Tissue Formation)

  • 김민태
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.559-565
    • /
    • 2022
  • 대체적으로는 전임상 평가로써 소·대동물을 통한 의료기기 개발 평가를 이루고 있으며 본 연구에서는 소화기계 위 날문부 협착 치료 평가모델 개발을 위해 스텐트 삽입 후 발생하는 조직 과증식 형성 모델을 개발하고자 한다. 파일럿실험으로 백서 3마리에서 날문부에 조영제를 주입하고 정상의 날문부 사이즈를 확인하였으며, 그에 맞는 사이즈의 스텐트를 삽입하였다. 1주일 내에 모든 백서에서 스텐트의 이동이 확인되었으며 본 실험에서는 스텐트를 투시 가이드 하에 gastrostomy 후 스텐트 삽입 시 날문부를 suture 하여 고정하여 조직 과증식이 형성이 가능하도록 하였다. 20마리의 백서를 Healthy Group / Gastrostomy Group으로 나누었다. Stent Group 백서를 마취 후 복부 절개 후 투시 가이드하에 gastrostomy를 실시하여 위 날문부에 스텐트를 삽입하였다. 또한, 연동운동에 의한 스텐트의 이동을 방지하기 위하여 위의 스텐트와 스텐트가 삽입된 위의 날문부를 suture 하여 고정하였다. 수술 후 행동 및 체중 변화를 매주 모니터링 하였다. 수술 후 4주 뒤 위장조영술을 시행 후 희생하였다. 위의 날문부 과증식 정도 평가를 위해 희생 후 적출한 위의 날문부 병리학적 분석을 실시하였다. 조직병리 및 면역 염색 평가에서 Gastrostomy Group이 통계적으로 유의하게 더 높았다(all p<.001). 결론적으로 Gastrostomy를 통한 위 날문부 수술 모델은 위 날문부 스텐트 삽입술 전임상 평가를 위한 조직 과증식의 형성 정도가 연구평가 툴로써 적정한 것으로 사료된다.

동적 하중을 받는 암반 구조물의 수치해석 변수에 대한 고찰 (A Study on the Numerical Analysis Variables of Rock Structures Subject to Dynamic Loads)

  • 류창하;최병희;장형수
    • 화약ㆍ발파
    • /
    • 제36권3호
    • /
    • pp.10-18
    • /
    • 2018
  • 동적 하중을 받는 암반의 역학적 거동은, 같은 크기의 최대 하중이라도 정적으로 가해지는 경우와는 다른 특성을 보인다. 동적 하중 하에서의 거동 특성을 규명하기 위한 실험적 접근 방법은 동적 하중의 제어와 계측 및 해석에 있어서 정적 조건에서의 실험 방법보다 더 많은 어려움이 있다. 수치해석적 방법은 물리적 실험이 아니라 수치해석적으로 실험을 실시함으로써 물리적 제약을 덜 받으므로 설계 단계에서 매우 유력한 해석 도구가 될 수 있다. 그러나 수치해석방법은 해석방법의 알고리즘이 적정하더라도, 입력 자료와 경계조건의 설정에 따라 계산 결과가 많이 달라질 수 있으므로 해석 시 세심한 주의가 필요하다. 본 논문에서는 동적 하중을 받는 암반 구조물의 거동을 수치해석적으로 검토할 때, 경계 조건, 동적 하중과 계산 시간 간격, 동적 하중 특성이 계산 결과에 미치는 영향을 검토하여, 동적 해석 시 경계조건과 계산 시간 간격의 설정 지침을 제공하고자 하였다.

CT 유도하 국소적 폐질환의 경피적 흡입생검의 장점과 결과 분석 (Analysis of the Result and Merit of Computed Tomography Guided Percutaneous Needle Aspiration Biopsy of Focal Lung Lesion)

  • 장유송;조길호;변우목;황미수;박복환
    • Journal of Yeungnam Medical Science
    • /
    • 제10권1호
    • /
    • pp.127-134
    • /
    • 1993
  • PTNB는 최근 CT 기술의 발전과 20 gauge 또는 22 gauge의 세침의 개발로 합병증을 줄이는 한편, 성공율이 높아 점차 임상적으로 널리 이용되는 추세에 있다. 이에 저자는 최근 44례의 PTNB를 분석하여 다음과 같은 결과를 얻었다. 환자의 분포는 50대 남자가 17례로 가장 많았고 종괴의 크기와 위치는 4cm 전후가 36례(84%)로 가장 많았다. 종괴의 국소적 위치는 변연부에 위치한것이 33례(75%)의 주로 폐의 변연부에 위치하였다. 조직 채취는 42례(95%)에서 가능했으며, PTNB의 민감도는 61%(27/44)였고 악성종괴와 양성종괴에 대한 민감도는 각각 79%(19/24), 44%(8/18)였다. 민감도가 비교적 낮은 이유는 단 1회 시술로 결과를 얻었고 민감도를 높이기 위한 반복 PTNB는 시행하지 않았기 때문으로 생각한다. 합병중인 기흉이나 각혈은 각각 1례에서 얻었고 모두 특별한 치료없이 호전되었다. 이상에서 PTNB는 다른 검사 방법 보다 간편하고 안전하며 기관지경을 통한 생검이 불가능하거나 생검후에도 병리소견을 못얻을 경우 PTNB를 통해 양성질환과 악성질환을 구분하므로서 환자의 치료 방침 결정에 도움을 줄 수 있을 것으로 사료되며, 국소적 폐 질환의 진단에 있어서 PTNB의 유용성은 더욱 증가하리라고 전망된다.

  • PDF

U.K. 지구시스템모델 UM의 리눅스 클러스터 설치와 성능 평가 (An Installation and Model Assessment of the UM, U.K. Earth System Model, in a Linux Cluster)

  • 윤대옥;송형규;박성수
    • 한국지구과학회지
    • /
    • 제43권6호
    • /
    • pp.691-711
    • /
    • 2022
  • 지구 대기에 영향을 주는 거의 모든 인간활동과 자연현상을 수치적으로 담아내는 지구시스템모델은 기후 위기의 시대에 활용될 가장 진보한 과학적 도구이다. 특히 우리나라 기상청이 도입한 지구시스템모델인 Unified Model (UM)은 지구 대기 연구의 과학적 도구로써 매우 활용성이 높다. 하지만 UM은 수치 적분과 자료 저장에 방대한 자원이 필요하여 개별 연구자들은 최근까지도 기상청 슈퍼컴퓨터에만 UM을 가동하는 상황이다. 외부와 차단된 기상청 슈퍼컴퓨터만을 이용하여 모델 연구를 수행하는 것은 UM을 이용한 모형 개선과 수치 실험의 원활한 수행에 있어 효율성이 떨어진다. 본 연구는 이러한 한계점을 극복할 수 있도록 개별 연구자가 보유한 고성능 병렬 컴퓨터(리눅스 클러스터) 에서 최신 버전 UM을 원활하게 설치하여 활용할 수 있도록 UM 시스템 환경 구축 과정과 UM 모델 설치 과정을 구체적으로 제시하였다. 또한 UM이 성공적으로 설치된 리눅스 클러스터 상에서 N96L85과 N48L70의 두 가지 모형 해상도에 대하여 UM 가동 성능을 평가하였다. 256코어를 사용하였을 때, 수평으로 1.875° ×1.25° (위도×경도)와 수직으로 약 85 km까지 85층 해상도를 가진 N96L85 해상도에 대한 UM의 AMIP과 CMIP 타입 한 달 적분 실험은 각각 169분과 205분이 소요되었다. 저해상도인 3.75° ×2.5° 와 70층 N48L70 해상도에 대해 AMIP 한달 적분은 252코어를 사용하여 33분이 소요되는 적분 성능을 보였다. 또한 적분을 위해 사용된 코어의 개수에 비례하여 적분 성능이 향상되었다. 성능 평가 외에 29년 간의 장기 적분을 수행하여 과거 지상 2-m 온도와 강수 강도를 ERA5 재분석자료와 비교하였고, 해상도에 따른 차이도 정성적으로 살펴보았다. 재분석자료와 비교할 때, 공간 분포가 유사하였고, 해상도와 대기-해양 접합에 따라 모의 결과에서 차이가 나타났다. 본 연구를 통해 슈퍼컴퓨터가 아닌 개별 연구자의 고성능 리눅스 클러스터 상에서도 UM이 성공적으로 구동됨을 확인하였다.