• Title/Summary/Keyword: size

Search Result 66,023, Processing Time 0.064 seconds

The Influence of Magnetic Particle Size and Its Properties on The Electromagnetic Particle in Magnetic Tape (자기 Tape의 전자 변환 특성에 대한 자성분의 Size와 그 특성의 영향)

  • 김상문;김태옥
    • Journal of the Korean Magnetics Society
    • /
    • v.6 no.5
    • /
    • pp.334-339
    • /
    • 1996
  • In order to investigate the influence of the magnetic paticle size and its properties on the particulate magnetic material, we evaluated the dispersion of magnetic particles and the electromagnetic properties in magnetic tape made from the magnetic paints by use of each magnetic particles witch were different from particle size and its propertis. The dispersion of magnetic particles depends on the surface chemical properties rather than particle size. As particle size is smaller, the packing ratio of magnetic particle and the magnetic flux density in tape increase. The output levels in playing back of tape incerase in wide frequency range from 315 Hz to 10 kHz and the noises decrease. It is very important to choose the size, the shape, the surface chemical properties and the magnetic properties of the magnetic particle in producing the high quality magnetic tape.

  • PDF

Ecological Relationship Between Body Size and Fecundity in the Slipper Shell, Crepidula onyx Sowerby (Gastropoda: Calyptraeidae) in Korean Waters

  • Son Min Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.36 no.6
    • /
    • pp.625-631
    • /
    • 2003
  • The aim of the present study was to investigate the ecological relationship between female body size (=shell length) and fecundity in a Korean population of protandric hermaphrodite, Crepidula onyx Sowerby, using 6 reproductive variables (the number of capsules per brood, capsule size, the number of embryos per capsule, total number of embryos per brood, egg size, and larval size). The investigation was based on 32 females, 107 egg capsules, 263 eggs, and 250 veliger larvae sampled in January 2000, from Yangpo, the southeastern coast of Korea. All foregoing reproductive variables, except larval size, were significantly correlated with the female body size (p<0.001$\~0.01$). There was a significant increase both in the number of capsules per brood and the number of embryos per capsule with female body size (p<0.001). Consequently, the fecundity of the female C. onyx increased with female body size to over 14.65 mm (the minimum size of egg brooding in the present study). This investigation, therefore, provides additional evidence that female fecundity of protandric hermaphrodites is positively correlated with female body size.

Comparative Assessment of the Vertebral Left Atrial Size in Healthy Adult Dogs

  • Han, Sung-Hyun;Yun, Mun-Su;Song, Kunho
    • Journal of Veterinary Clinics
    • /
    • v.39 no.2
    • /
    • pp.45-50
    • /
    • 2022
  • Vertebral left atrial size can be used as a radiographic tool to evaluate left atrial size in dogs. Vertebral left atrial size has been studied in dogs; however, few studies have been conducted on breed-specific differences in healthy dogs. To study the median vertebral left atrial size differences by breed and to investigate the association between age, sex, body condition score, thoracic depth-to-width ratio, and vertebral left atrial size. A total of 220 dogs of the following breeds: Maltese (n = 73), Beagle (n = 30), Poodle (n = 41), Shih-tzu (n = 44), and Mongrel (n = 32) were reviewed retrospectively. Sex, body weight, age, and body condition score of each dog were collected. Thoracic radiography was conducted for dorsoventral and right/left lateral views in all dogs to measure the vertebral heart score, vertebral left atrial size, and thoracic depth-to-width ratio. No significant differences in the median vertebral left atrial size were found among the breeds. There were no effects of sex, age, body condition score, and thoracic depth-to-width ratio on vertebral left atrial size. There was a significant positive correlation between the vertebral heart score and vertebral left atrial size. Breed, age, sex, and chest conformation did not correlate with vertebral left atrial size.

The Sizing Communications in Online Apparel Retail Websites - Focusing on Ready-to-Wear Women's Tailored Jacket - (온라인 의류 쇼핑 사이트의 제품 사이즈 정보 실태 분석 - 여성용 테일러드 재킷을 중심으로 -)

  • Lee, Ah Lam;Kim, Hee Eun
    • Fashion & Textile Research Journal
    • /
    • v.22 no.5
    • /
    • pp.617-627
    • /
    • 2020
  • This study investigates the apparel sizing communication presented in online retail websites focusing on women's ready-to-wear tailored jackets and to analyze the meaning of these information as the actual product size guide factor. A total of 34 retail websites were selected based on the highest growth fashion companies list and the best fashion brands list. We collected size information in two types: size specifications including sizing code, body measurements, garment measurements, and size references including customized size guide tools, size information in customer reviews, model size information, and others. Most websites prefer to present garment measurements rather than body measurements that are recommended notations under Korean standards and related regulations. In addition, there was the absence of consistency in presenting measurements list and terms that can confuse consumers in size communication. This study found that the stature measurement was a key factor in size reference despite that it did not represent a proper garment size. The obsolete Korean numbering sizing code such as '55 and '66 was still used in many ways such as idiomatic expressions for body shape. It also implied that we can take advantage of the old sizing code for accessible size information. The finding of this study gives an in-depth diagnosis of current online sizing information problems and suggests useful basic data for developing online apparel size standards and marketing strategies.

Interpretation of Morphology and Rubber-Phase Particle Size Distribution of High Impact Polystyrene (내충격성 폴리스티렌의 형태구조 및 고무상 입도분포 해석)

  • 정한균;정대원;안경현;이승종;이성재
    • Polymer(Korea)
    • /
    • v.25 no.5
    • /
    • pp.744-753
    • /
    • 2001
  • One of the most important factors which affect the impact strength of high impact polystyrene (HIPS) is the rubber-phase particle size and size distribution. In this study, HIPS was prepared from a batch reactor to observe the influence of reaction conditions such as rubber content, agitation speed and prepolymerization time on the particle size and size distribution. Measurements concerning the particle size distribution were conducted using a particle size analyzer. Due to swelling, the particle suspended in toluene increases in size with lower heat-treatment temperature and shorter heat-treatment time, while the particle in methyl ethyl ketone shows quite reasonable size without any effort of heat-treatment. As rubber content increases, the average particle size increases substantially, but the increase in agitation speed at lower rubber contents does not have much influence on the size. However, the polystyrene-phase particles occluded in rubber-phase become more uniform as agitation speed increases. Longer prepolymerization time produces rubber-phase particles with narrower particle size distribution.

  • PDF

A Study on the Size Designation of Foundation Garments (화운데이션의류의 치수규격에 관한 연구)

  • Lee Jun-Ok;Seong Hwa-Kyung;Choi Hei-Sun;Yi Kyong-Hwa
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.6 s.154
    • /
    • pp.892-903
    • /
    • 2006
  • This study was to carry out interview and survey of currently marketed foundation garment, focusing on manufacturers, on the basis of data of Year 2004 SIZE KOREA in 2004, to re-establish suitable age range and standard size, to simplify size interval scale and size system and to revise the standard for consumers' easy understanding and availability; The findings of this study are as follows. 1. Considering the age, in which a bra is worn, has reduced socially, the applicable age range was expanded into $8{\sim}80$ years old, which was divided into for junior and for adult. 2. For bra size, the standard title changed into the foundation garments size standard, in which girdle and bodysuit were included. 3. Basic physical parts for establishing for bra size are underbust and bust. Interval scale of under bust and bust was 5cm and 2.5cm, respectively. And basic physical parts are waist and hip girth for girdle, and underbust, bust, and hip girth for bodysuit. 4. For bra size, underbust girth was applied together with bra-cup size without 'cm' unit. For bra-cup size, difference between underbust and bust was represented as English alphabet. In other words, AAA means that difference between under bust and bust is 5cm. AA, A, B, C and D means that the difference are 7.5cm, 10cm, 12.5cm, 15cm and 17.5cm. 5. For girdle size, waist girth was applied together with hip girth without 'cm' unit. And for bodysuit size, underbust girth was applied together with cup size like bra size, and English alphabet represented hip girth range.

A Study on the Wearing Conditions of Big Size Brassiere for the Women with Bigger Than C Cup Size (빅 사이즈 브래지어 착용실태에 관한 연구 -C컵 이상을 중심으로-)

  • Kim, Nam-Soon;Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.1
    • /
    • pp.123-133
    • /
    • 2008
  • The purpose of this study is to analyze dissatisfaction and size appropriateness of the women with big breast for design the high functional big size brassiere. The data were collected from 179 women(between the ages of 20 and 39) residing in Gwang-ju using a questionnaire to purchase, wearing comfort, dissatisfaction of the size, wire and the pad of the big size brassiere. The data were analyzed with Chi-square test, t-test and ANOVA using statistical program SPSS 12.0. The results of this research are as follows; 1) Seven-two-point-two percent of the women with big breast more than C cup size polled said they had difficulty in looking for the suitable size of the brassiere and they usually weared the smaller size than the their own size. As a result, they felt inconvenience for the discord with the nipples and lack of the shape revision. 2) According to the result of the correlation analysis, breast size and Rohrer's index showed low correlation. 3) After dividing all respondents for this research into categories of the group of more than C cup and less than B cup the differences in responses were compared. The dissatisfaction with brassier were 'discord of cup size', 'pain due to the wire' and 'unnatural breast shape' in the group of more than C cup, compared to 'discord of cup size' and 'deformation of the wire and pad' in the group of less than B cup.

An Analysis of Size System and Patterns of Ready to Wear Basic Skirts for Middle Age Women (중년여성 브랜드를 통한 기본 스커트의 치수실태 및 패턴분석)

  • Lee, Jung-Soon;Goo, Mi-Ran
    • Fashion & Textile Research Journal
    • /
    • v.6 no.6
    • /
    • pp.756-764
    • /
    • 2004
  • The purpose of this study is to analyze of size and patterns of ready to wear basic for middle age women. For this purpose, I select 9 brands and analyze the basic skirts size system marketed in 2002 spring in Korea. To study the actual size system, I have compared size labeling, which I researched, with Korean Industrial Standard Size Chart. And I also have compared body measurement with the product size. To study the pattern, I have classified the composition of the skirt into 24 items. The different result shows between this study and Korean Industrial Standard Size Chart. The waist circumference is smaller than it should be, and the hip circumference is larger than it should be. As I have examined the body measurement and the product size, variability of the waist circumference depends on the location of the waistline. For the hip circumference, I have found that both the body measurement and the product size are same, or the product size is smaller than the body measurement. Both cases have been found to be over 67%. I have classified the analysis of the pattern into four components; circumference, relevance to waist line, dart, and length. For the waist circumference, the same size of the front and the back is 44.4%, and making the front larger is 44.4% also. In the hip circumference, the identical size of the front and the back is 66.7% and the larger size of back is 22.2%. Regarding darts placement, it is moved to the side lines from the middle of 1/2 of waist lines, dart intake was 1.3~3.2 cm, the length of darts is 7.2~12.7 cm.

Infleunce of Nozzle Tip Size on the Preparation of Nano-Sized Tin Oxide Powder by Spray Pyrolysis Process

  • Yu, Jaekeun;Kim, Donghee
    • Korean Journal of Materials Research
    • /
    • v.23 no.2
    • /
    • pp.81-88
    • /
    • 2013
  • In this study, using a tin chloride solution as the raw material, a nano-sized tin oxide powder with an average particle size below 50 nm is generated by a spray pyrolysis process. The properties of the tin oxide powder according to the nozzle tip size are examined. Along with an increase in the nozzle tip size from 1 mm to 5 mm, the generated particles that appear in the shape of droplets maintain an average particle size of 30 nm. When the nozzle tip size increases from 1 mm to 2 mm, the average size of the generated particles is around 80-100 nm, and the ratio of the independent particles with a compact surface structure increases significantly. When the nozzle tip size is at 3 mm, the majority of the generated particles maintain the droplet shape, the average size of the droplet-shaped particles increases remarkably compared to the cases of other nozzle tip sizes, and the particle size distribution also becomes extremely irregular. When the nozzle tip size is at 5 mm, the ratio of droplet-shaped particles decreases significantly and most of the generated particles are independent ones with incompact surface structures. Along with an increase in the nozzle tip size from 1 mm to 3 mm, the XRD peak intensity increases, whereas the specific surface area decreases greatly. When the nozzle tip size increases up to 5 mm, the XRD peak intensity decreases significantly, while the specific surface area increases remarkably.

Effects of Crystal Grain Size and Particle Size on Core Loss For Fe-Si Compressed Cores

  • Takemoto, Satoshi;Saito, Takanobu
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1183-1184
    • /
    • 2006
  • Core loss of soft magnetic powder cores have been focused on to achieve high efficiency of power supplies. In this study the effects of crystal grain size on core loss were investigated by changing heat treatment conditions. It was found that core loss is influenced by crystal grain size because eddy current loss decreased and hysteresis loss increased by making crystal grain size smaller, and it is also influenced by particle size.

  • PDF