• Title/Summary/Keyword: size

Search Result 66,023, Processing Time 0.067 seconds

Studies on the Control of Porosity and Mean Pore Size in Cordierite Ceramics (Cordierite의 기공률 및 기공경조절에 관한 연구)

  • Yang, Jin
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.4
    • /
    • pp.399-405
    • /
    • 1998
  • The effect of each factor on the porosity and mean pore size of cordierite(2Mg$.$2{{{{ {Al}_{2 } {O }_{3 } }}$.$5{{{{ {SiO}_{2 } }}) ceram-ics which have been mainly used for hot gas filter was investigated by using orthogonal array. The poros-ity was observed to increase with the content of graphite added as pore-forming material and decrease with increasing talc size. The effects of the other factors the graphite size sintering temperature and hold-ing time at sintering temperature were observed to be small relatively. In case of mean pore size the ef-fect of talc size on the mean pore size of cordierity was investigated to be the largest. The mean pore size was observed to increase with increasing talc size.

  • PDF

A Study on the Homemakers' Housing Notion according to Unit Size in Apartment - focus on 20pyung∼50pyung - (공동주택 평형별 주부들의 주거관에 관한 조사연구 - 20평형대∼50평형대를 중심으로 -)

  • 장경수;김경순
    • Korean Institute of Interior Design Journal
    • /
    • no.38
    • /
    • pp.116-124
    • /
    • 2003
  • The purpose of this study was provide basic data for homemakers' housing notion according to unit size in apartment. This study was conducted by questionnaires that concerning about middle class homemakers whom they lived in Bundang. The results of this study were as follows; 1) In research on the homemakers' general quality, 20pyung unit size was alike 30pyung unit size and 40pyung unit size was similar to 50pyung unit size. 2) Homemakers' perception according to unit size in apartment was various; (a) 20pyungㆍ30pyung unit size-effective household space for husbands' participation, more sports facilities, parking lot space etc. (b) 40pyungㆍ50pyung unit size-homemakers' individual room, ordering and variable unit plan etc. 3) In research on the homemakers' needs, each of unit size was analogous to storage, common facility, new design and new housing form etc.

The Piezoelectric Characteristics Depending on the GrainSize of the PT-PZ-PNN Ceramics (압전변압기용 PT-PZ-PNN 세라믹스의 그레인 크기에 따른 압전특성)

  • 박정호;김철수;김성곤;이상렬
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.10
    • /
    • pp.815-820
    • /
    • 2001
  • The piezoelectric properties of the PT-PZ-PNN system ceramics were investigated depending on the variati on of the grain size. The grain size was varied by sintering temperature, and additive. The effect of the grain size on the electrical, dielectric, and piezoelectric properties was studied with respect to the feasibility of the application for the piezoelectric transformer. Grain size increased as the PMW contents increased. The smaller the particle size used, the smaller the grain size obtained. Specimens are densily sintered. Dielectric and piezoelectric properties are not always improved in proportion to the grain sizes. When he particle size are fine and the grain size are increased properly with the optimum additives, the piezoelectric preperties have good values. the specimen sintered at 1200$\^{C}$ with PMW 2 mol% and MnO$\_$2/ 0.5wt% contents exhibited good piezoelectric properties for a piezoelectric transformer.

  • PDF

A study on consumer's preference for size labeling system of womens's ready-to-wear garments

  • 천종숙
    • Journal of the Ergonomics Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.105-117
    • /
    • 1996
  • This study was initiated to investigate (1) whether consumers preferred a specific garment size labeling system and (2) whether consumer's demographic characteristics, clothing behavior, and body size affect their preference of size labeling systems. The survey of consumer's preferences for five size labeling systems included 443 women with 20 to 64 years of age. The result of the survey showed that the subjects' preferences of five size labeling sysems were different significantly. Subjects strongly preferred the old system rather than the revised systems. The subjects least preferred the system with pictogram(system D) and the system with description of the measuring methods of te control dimensions (system E). The subjects/ preference for various garment size labeling systems was different depending on their resident area, educational level, and body size. The garment size labeling system with more information on body measurements (system C) was preferred by the subjects living in the metro city area or subjects having difficulties on purchasing ready-to-wear garments giving reasonable fit. The simplest size labeling system (system A) was strongly preferred by the subjects of low educational level, or the subjects living in the small city.

  • PDF

Improved Identity-Based Broadcast Encryption (개선된 Identity 기반의 브로드캐스트 암호화 기법)

  • Kim, Ki-Tak;Park, Jong-Hwan;Lee, Dong-Hoon
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.347-349
    • /
    • 2008
  • The primitive of Identity-Based Broadcast Encryption allows a sender to distribute session keys or messages for a dynamically changing set of receivers using the receiver's identity as a public key. We already know that the trade-off exists the efficiency between the public parameter size and the ciphertext size. So, if the ciphertext size is O(1), then the public parameter size may be O(n). Some of IBBE scheme take the public parameters as input in decryption phase. Thus, a decryption device (or client) has to store the public parameters or receive it. This means that a decryption device (or client) has to have the proper size storage. Recently, delerabl$\square$e proposed an IBBE which have the O(1) size ciphertexts and the O(n) size public parameters. In this paper, we present an IBBE scheme. In our construction the ciphertext size and the public parameter size are sub-linear in the total number of receivers, and the private key size is constant.

  • PDF

The Study on Brassiere Size Charts in Adult Women (한국 여성 브래지어 치수 분포에 관한 연구)

  • 이경화
    • Journal of the Korean Home Economics Association
    • /
    • v.33 no.6
    • /
    • pp.199-211
    • /
    • 1995
  • The purpose of this study was to provide a brassiere size chart for making the well-fitted brassiere. The subjects are 2811 women whose range of age is 12 to 59. These woman were classified into 5 age groups by seniority ; age group 1(12~19), age group 2(20~29), age group 3(30~39), age group 4(40~49), age group 5(50~59). statistical differences of measurements were analyzed among 5 age groups through ANOVA. Correlation between measurements were analyzed by correlation analysis. In addition, new brassiere size chart and production rate tables were proposed in this study. The results of the study were as follows. 1) Most of the body measurements were significantly different among 5 age groups. The height was decreasing by getting older while weight was increasing significantly. The 3 girth measurements(top bust, bust, under bust girth) in breast, bust width, bust depth were apt to increase definitely. The 3 girth measurements had high Correlation coefficients among 3 girth mesurements. Therefore, it is valid to pick out cup size and under bust girth for representative items of size chart. 2) Under bust girth and cup size were chosen as 2 axes of brassiere size chart. From the dual distribution table whose intervals had been determined by KS size chart, 17 sizes, which had more than 2% of appearance, were suggested for brassiere size chart. Through these new size charts, the suggested brassiere sizes covered 82.5% of all subjects. The suggested brassiere size chart would be more helpful than KS size chart in making the well-fitted brassiere.

  • PDF

The Comparison of Ultrasonographic Size of Morton's Neuroma measured to Actual Size (Morton씨 지간 신경종의 초음파검사상 크기와 실제 크기의 비교)

  • Kim, J-Young;Lee, Kyung-Tae;Young, Ki-Won;Son, Sang-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.10 no.1
    • /
    • pp.80-83
    • /
    • 2006
  • Purpose: To compare ultrasonographic size of morton's neuroma measured to actual size. Materials and Methods: Thirty-two (twenty-eight patients) of symptomic Morton's neuroma were measured by ultrasonography preoperatively and by manual method that designed by authors intraoperatively from January, 2002 to May, 2003. Two results were stastically compared by paired T-test. Results: Except one, all of cases were women and the mean age of patients was 50.6 years (32-62 years). The most common associated disease was hallux valgus deformity (17 cases). Six of Morton's neuromas located on second intermetatarsal space, sixteen of them did third intemetatarsal space and ten of neuromas located simultaneously second and third intermetatarsal space. The ultrasonographic size of neuroma averaged 3.48 mm and real size was 3.99 mm. The size checked by manual method was larger than by ultrasound with statical meaning. Conclusion: The size of Morton's interdigital neuroma checked by ultrasonography on plantar aspect is smaller than real size. If you checked Morton's interdigital neuroma size by ultrasonography, you can suspect that real size of Morton's interdigital neuroma is larger than that size.

  • PDF

Fishing capacity and bycatch on spring net pot for conger eel by entrance size (스프링그물통발의 입구 크기에 따른 붕장어 어획성능과 혼획)

  • SONG, Dae-Ho;CHO, Sam-Kwang;CHA, Bong-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.52 no.1
    • /
    • pp.9-16
    • /
    • 2016
  • This study was conducted to analyze fishing capacity and bycatch by mesh size and entrance size of spring net pot conducted by water tank and field experiment. The water tank experiments were conducted by using traps with mesh size of 22 mm and entrance size of 120 mm and 140 mm, respectively in the water tank of NIFS. The field experiment was conducted using 5 kinds of spring net pot with mesh sizes of 20 mm, 22 mm, 35 mm and entrance size of 120 mm, 130 mm, 140 mm, 360 mm by coastal trap fishery vessel operating around the area of Geoje island. In the result of water tank experiments, the catch of conger eel was 1.5 times higher when using trap with entrance size of 140 mm than that of 120 mm. In the field experiment, when using same mesh size, the larger the entrance size, the higher amount of conger eel catch, bycatch and number of bycatch species. When using the same entrance size, the larger the mesh size, the lower amount of conger eel catch and number of bycatch species, whereas the amount of bycatch showed increasing trend.

An Analysis of Body Measurement and Apparel Size for Woman's Ready-Made Jacket (여성 기성복 재킷의 치수 분석 - 신체치수와 제품치수의 비교를 중심으로 -)

  • Cho, Youn-Joo;Paek, Kyung-Ja;Lee, Jeong-Ran
    • Fashion & Textile Research Journal
    • /
    • v.6 no.3
    • /
    • pp.347-356
    • /
    • 2004
  • The purpose of this study is to analyze the sizing system and size designation of ready-made jackets for women. We survey the sizing system and size labeling that have been used and presently practiced by the domestic garment industry of ready-made woman's jacket. In addition, 264 tailored jackets are measured for the sake of this study. The jackets are classified into 3 groups(young, missy, and madame) according to the target age of the brand. The result shows that size labeling involves body measurements(85-94-160), size code(55, 66) or simplified letter(S, M, L). However, the correspondence of size information and ease tolerances of jackets is not consistent and each company has its own sizing system. There are significant differences among young, missy, and madame group on the bust girth of apparel in 66size code. The average apparel size piteh measurement distributions(bust girth and hip girth respectively) of young group are 9cm and 13cm in 55 size code, those of missy group are 7 em and 3 cm in 66 size code, and those of madame group are 6cm and 4cm in 77 size code. The ease of bust girth and hip girth in missy group are much more than other groups.

Sample Size Calculation in Medical Research (의학연구에서 표본크기 계산)

  • Pak, Son-Il;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.29 no.1
    • /
    • pp.68-77
    • /
    • 2012
  • Whenever planning a study design or preparing a research proposal it is highly recommended that investigators decide the optimum sample size that is required to yield an outcome of interest with a predetermined level of precision. This is because that, all else being equal, if a study with less than the optimum sample size would not detect the significance of differences in reality, and similarly, if a study with more than the optimum sample size will be costly. For these reasons, the majority of peer reviewed biomedical journals assess the adequacy of sample size requirements. The calculated sample size is used as a target number of samples to be collected to provide an estimate of the parameter with the desired and predetermined level of accuracy, and the sample size is a major determinant of the probability of detecting diseased animals from the population. There is no single method of calculating sample size for any given study design. In this context, the purpose of this article is to provide a collection of formulas and examples for some typical situations likely to be encountered in veterinary clinical practice and to highlight the importance of performing prospective sample size calculations when planning a research. Specifically, this paper is concerned with the basic principle of sample size calculation, and considerations for methodological applications were illustrated for a given data set. Also included in this paper is factors influencing sample size calculations using a statistically valid techniques. Appropriate methods to consider these factors are presented.