• Title/Summary/Keyword: sitting down

Search Result 82, Processing Time 0.021 seconds

The effect of posture on HRV (측정 자세에 따른 HRV변화)

  • Yang, Dong-In;Shim, Young-Woo;No, Hyung-Wook;Kim, Deok-Won
    • Proceedings of the IEEK Conference
    • /
    • 2009.05a
    • /
    • pp.399-401
    • /
    • 2009
  • The purpose of this study is looking for deviation of change in HRV caused of posture. Total 20 adults were measured for 40 minutes(10 minutes rest section and 30 minutes analysis section) when volunteers were sitting and lying down. Other factors which can change in HRV were controlled during measurement. The analysis section were divided by total 6 stages(each by 5 minutes), and compared and analyzed between sitting and lying down groups. It was also compared and analyzed stages in each group. In the result, there was difference at stage 5($20{\sim}25$ minutes interval), but no difference in the total data. The results of each stage in the group, lying down had difference. Therefore, sitting is more stable measurement for HRV study when subjects was waking over 15 minutes.

  • PDF

Feasibility of the Depth Camera-based Physical Health Monitoring System for Elderly Living Alone

  • Sungbae, Jo
    • Physical Therapy Rehabilitation Science
    • /
    • v.13 no.1
    • /
    • pp.106-112
    • /
    • 2024
  • Objective: This study aimed to evaluate the validity of a depth camera-based system for monitoring physical function, assessing its feasibility for accurately monitoring activities of daily living. Design: A cross-sectional study. Methods: Twenty-three participants were enlisted to perform fifteen activities of daily living within a living laboratory designed to simulate a home environment. Activities were monitored using a depth camera system capable of classifying actions into standing, sitting, and lying down, with a conventional video camera employed for activity recording. The duration of each activity, as measured by the system, was compared to direct observations made by a physical therapist which were analyzed using a motion analysis software. The association between these two measurement approaches was assessed through correlation analysis, coefficient of determination, intraclass correlation coefficient (ICC), and Bland-Altman plots. Results: Our findings indicated that standing activities exhibited the highest correlation (r=0.847) between the system measurements and physical therapist observations, followed by sitting (r=0.817) and lying down (r=0.734), which demonstrated lower correlations. However, the ICC and Bland-Altman plots revealed notable variances between the two measurement methods, particularly for activities involving lying down. Conclusions: In this study, the depth camera-based physical monitoring system showed promise feasibility in distinguishing standing, sitting, and lying down activities at home environments. However, the current study also underlined some necessities of enhancements in capturing lying down activities.

The Feasibility Study of Sit-to-stand and Stand-to-sit Assistive Chair for Elderly

  • Seonggwang Yu;Seungmuk Lee;Minsoo Kim;Dae-Sung Park
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.591-597
    • /
    • 2022
  • Objective: The sitting and standing are motions that correspond to the previous stage of rehabilitation to go to walking for daily life. The purpose of this study was to measure task times, path length of the center of pressure (COP) and activity on the vastus femoris muscle using surface electromyography (EMG) when standing up and sitting down. Design: One group cross-sectional design Methods: Fifteen elderly subjects (8 male, 7 female) participated. All subjects were tested three times according to four assist levels (non-assist, lower, middle, and maximal assist) using adjusts the length of spring at sit-to-stand and stand to sit on a chair. The task duration, and COP path length were recorded for the balance function on the Nintendo Wii fit board. The activity of the rectus femoris muscle was recorded on both legs using surface EMG. Results: The results showed that the task duration of the sit-to-stand and stand-to-sit were significantly increased compared to without assist (p<.05). The activation of the rectus femoris muscle more significantly decreased compared to without assistance at standing or sitting (p<.05). Conclusions: The assistive chair showed less quadriceps muscle activation during sitting and standing compared to without assistance. We suggest that our assist-standing chair can help with activities of daily living such as standing up and sitting down movements adjusting the spring length for control assist level by safely.

A Study on the Furniture and Main-Living Behavior of An-bang in Apartment Housing (아파트 안방의 가구와 주생활행위에 관한 연구)

  • Kang Hyung-gu;Kang Bong-Im;Lee Cheong-Woong
    • Journal of the Korean housing association
    • /
    • v.16 no.3
    • /
    • pp.1-7
    • /
    • 2005
  • The purpose of this study was to analyze the relationship of the floor classification and the main-living behavior, and the tendency of using furniture and space by surveying the situations of using An-bang space by apartment dwellers. An-bang is a factor that influences on the unit-plan organization, the whole spatial arrangements, and the spatial relation and size, and has the most severe friction between the tradition and western culture. Given seeing the results shown in the main-living behavior by floor type, that the rest and TV watching were shown to be high in terms of a free-standing type can be said that An-bang is more for the individual rest than far the purpose of family harmony. On the other hand, that the family courtesy was shown to be a little higher a sitting-down type, could be understood that the sitting-down style, which is a traditional living mode, is appearing in An-bang.

Comparative of Quadriceps Muscle Activity during Stair Gait depending on Short-time Sitting and Gender (단시간 착석과 성별에 따른 계단보행 시 대퇴사두근 근활성도 비교분석)

  • Sangha Park;Duhyun Kim;Sabin Chun;Qian Qian;Taegyu Kim;Young Hoon Kim;Jae Myoung Park;Jong Chul Park
    • Korean Journal of Applied Biomechanics
    • /
    • v.33 no.1
    • /
    • pp.10-16
    • /
    • 2023
  • Objective: The purpose of this was to find out the muscle activity of the quadriceps femoris by gender when sitting on a chair while performing stairs gait (US; Up-stairs, DS; Down-stairs). Method: 13 male subjects (age: 22.00 ± 1.68 yrs, height: 174.85 ± 6.10 cm, weight: 68.15 ± 9.83 kg) and 15 female subjects (age: 21.17 ± 1.58 yrs, height: 168.20 ± 5.55 cm, weight: 55.73 ± 6.94 kg) participated in this study. The study used wireless three channel EMG. Results: In this study, there was no gender difference in quadriceps femoris activity during the US and DS periods, and there was no significant difference between the male group before and after postural maintenance during the US and DS periods. The quadriceps muscle of the female group also did not show a significant difference before and after US sitting. However, the vastus medialis muscle activity during DS in the female group was significantly lower after application than before application of maintaining a sitting posture (p<.05). There was no interaction effect between the 15-minute sitting position application and gender. Conclusion: Our results demonstrate that sitting in a chair affects the transient functioning of the quadriceps muscle in women. Therefore, emphasize the need for active rest when sitting in a chair for long periods of time.

Development of Non-Motorized Lifting Chair For the Elderly (고령자를 위한 무동력 기립보조의자 개발)

  • Kim, Hyeon Jun;Yeo, Hyeon Jin;Kim, Sung Soo;Chang, Sung Ho;Lee, Sang Ho;Bae, Ik Soon
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.38 no.4
    • /
    • pp.226-232
    • /
    • 2015
  • The aging of Korea is rapidly advancing in an unprecedented rate in the world. Indoor and outdoor safety accidents involving the elderly frequently occur, with elderly population increasing. Because the physical strength of elderly is decreased, it is necessary to develop devices that aid the everyday life of the elderly to prevent safety accidents. Among many activities, the motions of standing from and sitting on a chair require much physical strength from particular body parts, which causes an overload for particular body parts. To the elderly the repeating motion of standing from and sitting down on a chair is burdensome, because they do not have enough physical strength compare to young persons. As a result the elderly could be injured or falling during standing or sitting. Therefore, the development of a lift chair that considers the problems mentioned above is necessary to prevent the safety accidents of the elderly. The study designed a non-motorized lift chair that comfortably aids the standing and sitting down motion for the use of the elderly by reflecting the anthropometric data of the Korean elderly over 65 years old. Also the design was implemented to smoothly aid the standing motion by considering the knee angle of the elderly when standing. Because the regained strength to stand from a chair is depend on the knee angle. Unlike existing lift devices, this device utilizes a tilting mechanism that does not use electric power so that the product could be composed inexpensively than existing chairs released in the market.

Implementation of CNN Model for Classification of Sitting Posture Based on Multiple Pressure Distribution (다중 압력분포 기반의 착석 자세 분류를 위한 CNN 모델 구현)

  • Seo, Ji-Yun;Noh, Yun-Hong;Jeong, Do-Un
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.21 no.2
    • /
    • pp.73-78
    • /
    • 2020
  • Musculoskeletal disease is often caused by sitting down for long period's time or by bad posture habits. In order to prevent musculoskeletal disease in daily life, it is the most important to correct the bad sitting posture to the right one through real-time monitoring. In this study, to detect the sitting information of user's without any constraints, we propose posture measurement system based on multi-channel pressure sensor and CNN model for classifying sitting posture types. The proposed CNN model can analyze 5 types of sitting postures based on sitting posture information. For the performance assessment of posture classification CNN model through field test, the accuracy, recall, precision, and F1 of the classification results were checked with 10 subjects. As the experiment results, 99.84% of accuracy, 99.6% of recall, 99.6% of precision, and 99.6% of F1 were verified.

Avoiding Venous Anastomotic Dehiscence of an Arteriovenous Graft in a Super-Obese Patient

  • Bae, Miju
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.417-419
    • /
    • 2020
  • Surgeons avoid creating arteriovenous fistulae in obese patients owing to deep vessels, cannulation complications, and inconsistent outcomes. We describe placing an arteriovenous polytetrafluoroethylene (PTFE) graft between the brachial artery and axillary vein to avoid these complications. A 39-year-old super-obese woman with end-stage renal disease had undergone several hemodialysis access procedures on both arms. We traced the course of the arteriovenous graft course with the patient sitting and lying down. The ideal course was more accurate with the patient sitting; thus, the patient sat when the course was drawn, before lying on the operating bed. The PTFE graft was placed between the right brachial artery and axillary vein, according to the course in the opposite arm. No anastomotic dehiscence or pseudoaneurysm has taken place during 2 years of follow-up. In super-obese patients, the ideal course for arteriovenous grafts should be drawn while they are sitting, avoiding skin folds. This tip could avoid anastomotic dehiscence and pseudoaneurysm between the axillary vein and a PTFE graft.

Correction Algorithm for PDR Performance Improvement through Smartphone Motion Sensors (보행자 추측 항법 성능 향상을 위한 스마트폰 전용 모션 센서 보정 알고리즘)

  • Kim, Do Yun;Choi, Lynn
    • KIISE Transactions on Computing Practices
    • /
    • v.23 no.3
    • /
    • pp.148-155
    • /
    • 2017
  • In this paper, we develop a new system to estimate the step count for a smartphone user. The system analyzes data obtained from the accelerometer, magnetic sensor, and gyroscope of an android smartphone to extract pattern information of human steps. We conduct an experiment and evaluation to confirm that the proposed system successfully estimates the number of steps with 96% accuracy when hand-held and 95.5% accuracy when in-pocket. In addition, we found that detection errors were caused by human motions such as touching the screen, shaking the device up and down, sitting up and sitting down, and waving the phone around.