  • The purpose of this study is to develop a Smart Helmet to safeguard forest firefighting crews and provide on-site information in real time. The Smart Helmet for forest firefingting crews is equipped with a camera, video/voice communication module, GPS, Bluetooth, and LTE module to promote the safety of them, and through the Smart Helmet, the site situation is is transmitted in real time, and full duplex communication is possible. As a result of testing using the Smart Helmet, the control center was able to receive on-site information and communication with on-site forest firefighting crews. Through site evaluation and user evaluation, it was confirmed that the Smart Helmet needs to be improved. The developed Smart Helmet can be used in various ways in forest disasters and forest industry.

Design of Test Site for Large-Scale Wind Turbine Performance Verification (초대형 풍력터빈 시험을 위한 실증시험장 설계)

  • Sang-Man Kim;Tae-Yoon Jeong;Chae-Joo Moon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.3
    • /
    • pp.397-404
    • /
    • 2023
  • This paper designs a wind turbine test site based on international regulations for the certification of wind turbine prototypes. The maximum height of the meteorological mast installed at the test site is 140m, and power facilities capable of testing up to three wind turbines of 5MW or more are installed. The weather resources measured at the mast can be recorded and analyzed using a monitoring system. Wind turbine manufacturers can use this test site during the certification period, and the installed wind turbines can be used for continuous power generation projects. Therefore, this test site can provide fundamental data for measuring the long-term performance and durability of wind turbines, which can be used to improve models or develop new wind turbines.

Research on the Operation of Safeguards Equipment in Extreme Environmental Conditions (극한 환경 내 안전조치 장비 운영에 관한 연구)

  • Jiyoung Han;Suhui Park;Jewan Park;Yongmin Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.7
    • /
    • pp.1189-1195
    • /
    • 2023
  • In scenarios involving inspections and verifications of nuclear facilities, ensuring the proper functioning of on-site safeguards equipment is crucial. There have been precedents in Kazakhstan where equipment failed to operate properly due to extremly cold temperatures, and the year-round minimum temperature at North Korea's Punggye-ri nuclear test site is approximately minus 30 degrees Celsius. To ensure the proper functioning of equipment in extreme environments for on-site verification of nuclear activities on the Korean Peninsula, relevant research is necessary. This includes confirming the functionality of equipment used in inspections and verifications, as well as analyzing factors that may disrupt their normal operation. This study aims to conduct a risk analysis for the normal operation of equipment in extreme environments and develop criteria and procedures for environmental-based performance testing. To achieve this, we conducted a risk analysis based on IAEA safeguards, analyzed the utilization of equipment, and performed a risk analysis associated with transportation for on-site verification considering the environmental characteristics of the Korean Peninsula. Furthermore, we provided performance testing criteria and procedures. The research results can be utilized as reference material in the verification and monitoring processes of nuclear activities.

Fabrication of Mechanical fatigue flawed Specimen and Evaluation of Flaw Size (기계적 피로결함 시험편 제조 및 결함 크기 평가)

  • Hong, Jae-Keun;Kim, Woo-Sung;Son, Young-Ho;Park, Ban-Uk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.1
    • /
    • pp.38-44
    • /
    • 2003
  • Performance demonstration with real flawed specimens has been strongly required for nondestructive evaluation of safety class components in nuclear power plant. Mechanical or thermal fatigue crack and intergranular stress corrosion cracking could be occured in the in-service nuclear power plant and mechanical fatigue crack was selected to study in this paper. Specimen was designed to produce mechanical fatigue flaw under tensile stress. The number of cycles and the level of stress were controlled to obtain the desired flaw roughness. After the accurate physical measurement of the flaw size and location, fracture surface was seal-welded in place to ensure the designed location and site. The remaining weld groove was then filled by using gas-tungsten are welding(GTAW) and flux-cored arc welding(FCAW). Results of radio graphic and ultrasonic testing showed that fatigue cracks were consistent with the designed size and location in the final specimens.

Oxidation and Repeated-Bending Properties of Sn-Based Solder Joints After Highly Accelerated Stress Testing (HAST)

  • Kim, Jeonga;Park, Cheolho;Cho, Kyung-Mox;Hong, Wonsik;Bang, Jung-Hwan;Ko, Yong-Ho;Kang, Namhyun
    • Electronic Materials Letters
    • /
    • v.14 no.6
    • /
    • pp.678-688
    • /
    • 2018
  • The repeated-bending properties of Sn-0.7Cu, Sn-0.3Ag-0.7Cu (SAC0307), and Sn-3.0Ag-0.5Cu (SAC305) solders mounted on flexible substrates were studied using highly accelerated stress testing (HAST), followed by repeated-bending testing. In the Sn-0.7Cu joints, the $Cu_6Sn_5$ intermetallic compound (IMC) coarsened as the HAST time increased. For the SAC0307 and SAC305 joints, the $Ag_3Sn$ and $Cu_6Sn_5$ IMCs coarsened mainly along the grain boundary as the HAST time increased. The Sn-0.7Cu solder had a high contact angle, compared to the SAC0307 and SAC305 solders; consequently, the SAC0307 and SAC305 solder joints displayed smoother fillet shapes than the Sn-0.7Cu solder joint. The repeated-bending for the Sn-0.7Cu solder produced the crack initiated from the interface between the Cu lead wire and the solder, and that for the SAC solders indicated the cracks initiated at the surface, but away from the interface between the Cu lead wire and the solder. Furthermore, the oxide layer was thickest for Sn-0.7Cu and thinnest for SAC305, regardless of the HAST time. For the SAC solders, the crack initiation rate increased as the oxide layer thickened and roughened. $Cu_6Sn_5$ precipitated and grew along the grain and subgrain boundaries as the HAST time increased, embrittling the grain boundary at the crack propagation site.

Development and Reliability Verification of Quality Control System for Compaction Grouting Method (컴팩션 그라우팅 공법의 품질관리 시스템 개발 및 신뢰성 검증)

  • Seo, Seok-Hyun;Lee, Jung-Sang;Jung, Eui-Youp;Park, Sang-Yeong;Lee, Hyo-Bum
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.4
    • /
    • pp.11-20
    • /
    • 2020
  • This study introduced the compact grouting method that can be used for improving soft ground and restoring buildings with unequal subsidence. The pump used in the traditional compact grouting method is a system that injects one hole each, which reduces the construction efficiency, and the analog injection method manually manages the construction by field workers, making it difficult to manage consistent quality. Pump and quality control system were developed to solve problems in existing construction. Since field supervisor determines amount of injected materials by using analog equipment and controls manually, it is difficult to manage consistent quality of construction. Therefore, the quality control system was developed in order to solve that problem. The quality control system consists of automatic mixing system of injection materials, multiple simultaneous injection pumps, and injection management monitoring system. Performance of the quality control system was verified through on-site testing, and ground improvement performance was verified through quality testing after testing and testing of the compact grouting method. Therefore, it is expected that the integrated quality control system developed will improve the quality assurance and efficiency and stability of construction at sites where construction and quality verification are difficult.

Exploring and calibrating local curvature effect of cortical bone for quantitative ultrasound (QUS)

  • Chen, Jiangang;Su, Zhongqing;Cheng, Li;Ta, De-An
    • Structural Engineering and Mechanics
    • /
    • v.48 no.4
    • /
    • pp.501-518
    • /
    • 2013
  • Apart from thinning of cortical layers, the local bone curvature, varying along bone periphery, modulates ultrasound waves as well, which is however often underestimated or overlooked in clinical quantitative ultrasound (QUS). A dedicated three-dimensional finite element modelling technique for cortical bones was established, for quantitatively exploring and calibrating the effect of local curvature of cortical bone on ultrasound. Using a correlation-based mode extraction technique, high-velocity group (HVG) and low-velocity group (LVG) wave modes in a human radius were examined. Experimental verification using acrylic cylinders and in vitro testing using a porcine femur were accomplished. Results coherently unravelled the cortical curvature exerts evident influence on bone-guided ultrasound when RoC/${\lambda}$ <1 for HVG mode and RoC/${\lambda}$ <2 for LVG mode (RoC/${\lambda}$: the ratio of local bone curvature radius to wavelength); the sensitivity of LVG mode to bone curvature is higher than HVG mode. It has also been demonstrated the local group velocity of an HVG or LVG mode at a particular skeletal site is equivalent to the velocity when propagating in a uniform cylinder having an outer radius identical to the radius of curvature at that site. This study provides a rule of thumb to compensate for the effect of bone curvature in QUS.

The Preliminary Study for Normative Current Perception Threshold values in the Korean Adults (성인의 Current Perception Threshold 예비조사)

  • Park, Dae-Gyu;Chun, Sung-Hong;Jeon, Jae-Soo;Kim, Yong-Ik;Hwang, Kyung-Ho;Park, Wook
    • The Korean Journal of Pain
    • /
    • v.10 no.1
    • /
    • pp.5-10
    • /
    • 1997
  • Background : The Current Perception Threshold (CPT) provides an objective, quantitative gauge of sensory nerve integrity which is obtainable from any cutaneous site. CPT measurement can confirm and quantify or rule out dysfunction of nerve through comparison with established normative values ($Neuval^{TM}$ CPT database). The aim of this study is to compare collected data from Korean adults with $Neuval^{TM}$ CPT database. Method : Normative data from 5 standard test site in face, hand, toe were obtained from 50 healthy adults. Three frequencies(5, 250, 2000 Hz) were stimulated with $Neuromoter^{(R)}$ CPT device. Results : The results of our data were statistically significantly different than Neuval data except in face, but within normal range. Sensory Threshold increased as the frequency of the stimulus changed from 5 Hz to 250 Hz to 2000 Hz., and from face to hand to toe. Conclusion : CPT testing is a valuable neurologic testing modality that is noninvasive and highly reliable for diagnosis and evaluation of sensory nerves where neuropathy is suspected.

  • PDF

Development and Verification of Resistivity Seismic Dilatometer(RSDMT) System for Characterizing Soft Soil Site (연약지반조사를 위한 전기비저항 탄성파 Flat DMT 장비의 개발 및 검증)

  • Bang, Eun-Seok;Kim, Young-Sang;Sung, Nak-Hun;Park, Sam-Gyu;Seo, Dong-Nam;Lee, Sei-Hyun;Kim, Jung-Ho;Kim, Dong-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.623-634
    • /
    • 2007
  • The aim of this research is development and verification of resistivity seismic dilatometer (RSDMT) system. The resistivity module for obtaining resistivity-depth plot and seismic module for obtaining wave velocity-depth plot are attached to the conventional flat dilatometer testing equipment. To enhance reliability and repeatability of seismic part in RSDMT, automatic testing system including automatic surface source, PC based data acquisition system and operating program were developed. To obtain real resistivity value of soil, geometric factor for the array of electrodes in RSDMT was derived empirically. The verification studies for the developed RSDMT system were performed at the southeast side of Korea where soil improvement work is planned. SPT, CPT, geophysical subsurface imaging techniques and some laboratory tests were performed for the comparisons. As one penetration of RSDMT, various soil parameters could be obtained. The results of field test showed good repeatability and reliability in every part. From these studies, developed RSDMT system was checked and the effectiveness of this system was verified in light of proper evaluation of geotechnical characteristics of soft soil.

  • PDF

Application of Resistivity Seismic Flat Dilatometer (RSDMT) System for Multiple Evaluation of the Soft Soil Site (연약지반의 복합적 평가를 위한 전기비저항 탄성파 Flat DMT 장비 적용)

  • Bang, Eun-Seok;Kim, Young-Sang;Park, Sam-Gyu;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.111-122
    • /
    • 2012
  • Resistivity seismic dilatometer (RSDMT) system is introduced. The resistivity module for obtaining resistivity-depth plot and seismic module for obtaining wave velocity-depth plot are attached to the conventional flat dilatometer testing equipment. To enhance the reliability and repeatability of seismic part in RSDMT, automatic testing system including automatic surface source, PC based data acquisition system and operating program was constructed. To obtain real resistivity value of soil, geometric factor for the array of electrodes in RSDMT was derived empirically. The verification studies for the developed RSDMT system were performed with SPT, CPTu, bender element test and DC resistivity survey. Through one penetration of RSDMT, various soil parameters were obtained and the reliability and repeatability of developed RSDMT system could be checked.