Abstract
This study introduced the compact grouting method that can be used for improving soft ground and restoring buildings with unequal subsidence. The pump used in the traditional compact grouting method is a system that injects one hole each, which reduces the construction efficiency, and the analog injection method manually manages the construction by field workers, making it difficult to manage consistent quality. Pump and quality control system were developed to solve problems in existing construction. Since field supervisor determines amount of injected materials by using analog equipment and controls manually, it is difficult to manage consistent quality of construction. Therefore, the quality control system was developed in order to solve that problem. The quality control system consists of automatic mixing system of injection materials, multiple simultaneous injection pumps, and injection management monitoring system. Performance of the quality control system was verified through on-site testing, and ground improvement performance was verified through quality testing after testing and testing of the compact grouting method. Therefore, it is expected that the integrated quality control system developed will improve the quality assurance and efficiency and stability of construction at sites where construction and quality verification are difficult.
Keywords
Compaction grouting; Quality control system; Multiple simultaneous injection; Automated mixing system;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Ahn, J. H. (2018). Evaluation of construction management techniques and standards for the umbrella method, Master Thesis, Department of Global Railroad, Global Convergence Graduate School, Korea National University of Transportation.
2 ASCE (1997), "Grouting: Compaction, Remediation and Testing", pp.1-337.
3 Chun, B. S. (2011), "Principles and practice for chemical grouting", Construction Industry Research Institute, Goomibook, pp.191-213.
4 Chun, B. S., Lim, H. S., Jo, C. H. and Jung, H. C. (1997), "Study on ground reinforcement method for Box structures of a construction project of railroad roadbed of new international airport in capital region", Construction Institute of Hanyang University, pp.7-21.
5 Chun, B. S. and Yeoh, Y. H. (2003), "Report of application in soft ground C.G.S method for construction project of containment area of dumping dredged soil", Korean Geo-Environmental Society, pp.6-10.
6 Karol, R. H. (1990), Chemical Grouting, 2nd Edition, Marcel Dekker, New York and Basel.
7 KC CODE KCS 64 20 50 (2019), Low Fluidity Mortar Injection Technique, pp.1-5.
8 Lee, E. K. (2015), A Study on Improvement of Rock Grouting Guide, Ph.D Thesis, Sejong University, pp.78-82.
9 Lee, S. D. (2010), Effectiveness of Vibratory Cement-based Grouting Technique, Master Thesis, Korea University, pp.6-8.
10 Nam, M. J. (2015). A study on the applicability of automatic grouting system for soil reinforcement, Master Thesis, Department of Civil Engineering, Graduate School of Civil Engineering, Hanyang University.
11 ASCE/GI (2010), Compaction Grouting Consensus Guide, ASCE Standard ASCE/G-1, 53-10, ASCE, Reston VA.
12 Warner, J. (1978), "Compaction Grouting-A Significant Case History", Journal of Geotechnical Engineering, Vol. 104, No.7, pp.837-847.