• Title/Summary/Keyword: site survey

Search Result 2,364, Processing Time 0.026 seconds

The Effect of Perceived Utilitarian Value and Service Quality of Internet Shopping on Repurchase Intention of Fashion Merchandise (인터넷 쇼핑에서 지각된 실용적 가치와 서비스 품질이 패션상품 재구매의도에 미치는 영향)

  • Lee, Eun-Jin;Hong, Byung-Sook
    • Journal of the Korean Society of Costume
    • /
    • v.56 no.7 s.107
    • /
    • pp.46-57
    • /
    • 2006
  • The purpose of this study is to analyze whether perceived utilitarian value and service qualify have an effect on repurchase intention of fashion merchandise in internet shopping. A survey was conducted from June 20 to July 30 in 2003, among married women aged in their 20s and 30s, on their purchase experience of fashion merchandise from internet shopping malls. The survey was conducted over the internet with 306 subjects. The statistical analysis methods were frequency analysis, reliability analysis, factor analysis, and multiple regression analysis. The results of this study were as follows. 1. A married women aged in their 20s and 30s were shown to high-purchasing on nightgown, underwear, women's pants, casual wear through internet shopping. Their perceived utilitarian value had an effect on repurchase intention of fashion merchandise in internet shopping. 2. The service quality factors were determined to be site reliability, site reactivity, order assurance, order easy, site organization. Service quality factors of site reactivity, order assurance, order easy, site organization had an effect on repurchase intention of fashion merchandise in internet shopping.

Electrical resistivity survey and interpretation considering excavation effects for the detection of loose ground in urban area

  • Seo Young Song;Bitnarae Kim;Ahyun Cho;Juyeon Jeong;Dongkweon Lee;Myung Jin Nam
    • Geomechanics and Engineering
    • /
    • v.35 no.2
    • /
    • pp.109-119
    • /
    • 2023
  • Ground subsidence in urban areas due to excessive development and degraded underground facilities is a serious problem. Geophysical surveys have been conducted to estimate the distribution and scale of cavities and subsidence. In this study, electrical resistivity tomography (ERT) was performed near an area of road subsidence in an urban area. The subsidence arose due to groundwater leakage that carried soil into a neighboring excavation site. The ERT survey line was located between the main subsidence area and an excavation site. Because ERT data are affected by rapid topographic changes and surrounding structures, the influence of the excavation site on the data was analyzed through field-scale numerical modeling. The effect of an excavation should be considered when interpreting ERT data because it can lead to wrong anomalous results. A method for performing 2D inversion after correcting resistivity data for the effect of the excavation site was proposed. This method was initially tested using a field-scale numerical model that included the excavation site and subsurface anomaly, which was a loosened zone, and was then applied to field data. In addition, ERT data were interpreted using an existing in-house 3D algorithm, which considered the effect of excavation sites. The inversion results demonstrated that conductive anomalies in the loosened zone were greater compared to the inversion that did not consider the effects of excavation.

Constrution and Application of Underground Facilities Survey System using the 3D Integration Map of Underground Geospatial Information (3차원 지하공간통합지도를 활용한 지하시설물 현장 측량 시스템 구축 및 적용)

  • SONG, Seok-Jin;CHO, Hae-Yong;HEO, Hyun-Min;KIM, Sung-Gil
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.24 no.4
    • /
    • pp.164-173
    • /
    • 2021
  • Recently, as underground space safety issues such as sink hole, ground subsidence and damage to old underground facilities have been increasing in urban areas, the precise management of underground facilities ins more required. Thus, this study developed a function to that, visualize on Integration Map of Underground Geospatial Information a real-time survey data of underground facilities acquired on site or underground facility survey data acquired through on-site survey after underground facility exploration and developed a function convert to surveying-results. In addition, using the on-site survey performance utilization function in connection with the Integration Map of Underground Geospatial Information developed through this study, the surveying -results obtained with the Total-station at the water pipeline burial construction site in Eunpyeong-gu, Seoul are visualized on the Integration Map of Underground Geospatial Information and On-site verification was performed by converting spatial-information performance files and transmitting the Integration Map of Underground Geospatial Information to the mobile center. Based on this, it was possible to verify the work procedure using the surveying-results in the area where the Integration Map of Underground Geospatial Information was built, and to review the direction of future improvement directions.

A Study on the Shallow Marine Site Survey using Seismic Reflection and Refraction Method (탄성파 반사법 및 굴절법을 이용한 천해저 지반조사에 대한 연구)

  • Shin, Sung-Ryul;Kim, Chan-Su;Jo, Churl-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.109-115
    • /
    • 2008
  • It is very important to estimate the physical properties of survey area and delineate the geological basement in marine site survey for the design of offshore structures. For the purpose of providing high quality data by means of engineering site survey, it is necessary to apply several survey techniques and carry out the integrated interpretation to each other. In this study, we applied single channel seismic reflection method and OBC (Ocean Bottom Cable) type seismic refraction method at shallow marine. We used a dual boomer-single channel streamer as a source-receiver in seismic reflection survey and airgun source-the developed OBC type streamer in seismic refraction survey. We made 24 channels OBC type streamer which has 4m channel interval and each channel is composed of single hydrophone and preamplifier. We tested the field applicability of the proposed method and applied the typical seismic data processing methods to the obtained reflection data in order to enhance the data quality and image resolution. In order to estimate the geological velocity distribution from refraction data, seismic refraction tomography technique was applied. Therefore, we could successfully perform time-depth conversion using the velocity information as an integrated interpretation. The proposed method could provide reliable geologic information such as sediment layer thickness and 3D basement depth map.

A Study of Planning for Sujeong-dong Garden Heritage Maintenance (고산 윤선도 수정동 정원유적 정비에 관한 연구)

  • Kim, Moo-Han;Sung, Jong-Sang
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.33 no.2
    • /
    • pp.12-20
    • /
    • 2015
  • Sujeong-Dong garden heritage is a unique, valuable villa garden constructed by Gosan Yoon Sun-Do during middle Joseon period. However, the site has been faced on damage risk because of the development of near quarry. The purpose of the study is to suggest careful maintenance plan for the valuable Korean traditional garden heritage. For the plan, the study conducts the interview of residents and experts, literature review, the investigation of historical materials, site survey, and the analysis of aerial photography. The results are following: Firstly, the paper divides the site into three types of an excavation area: core, recommend and investigation. Secondly, of remained Gosan's one and remains of unknown contents, it has the plan of vegetation maintenance, safety facilities, pathway maintenance, and service area. Thirdly, it also suggests pathway plan for authentic garden promenade according to the literature of Sanjungsingok(山中新曲), site survey, and interviews with residents and experts. The study has a special meaning for an insightful approach based on the accurate site survey, research, and the consideration of practical use.

A study on Sub-contractor Product Assurance for development of Ka band Communication Payload System of COMS (통신해양기상위성 Ka 통신탑재체 개발 공동 및 용역 개발 참여기관 제품보증 연구)

  • Jeong, Cheol-Oh;Lee, Seung-Pal
    • Journal of Aerospace System Engineering
    • /
    • v.3 no.1
    • /
    • pp.6-11
    • /
    • 2009
  • It is anticipated that quality assurance for the Ka band Communication Payload System(COPS) development program of the communication, Ocean & Meteorological Satellite(COMS) may be a core technical factor to be concerned in order to avoid any failure, and to assure its final performance during the mission lifetime in space. Those can be managed and verified and assessed by performing the Quality Assurance (QA) and risk management which helps to prevent and to reduce the critical fails. This paper introduces the Product Assurance (PA) system and procedures for controlling and monitoring sub-contractors which were participated in Ka band Communication Payload System (COPS) development. Also this paper shows Quality Assurance (QA) procedures and detailed their processes for assured the product performed by local companies from site survey for selecting companies to delivery of their equipment.

  • PDF

The Effect of Perceived Service Quality of Web Portal Site on Trust, Satisfaction and Revisit Intention (포털사이트의 지각된 서비스 품질이 후속 행동에 미치는 영향에 관한 연구)

  • Lee, Seung-Hee;Kim, Hye-Kyoung
    • Journal of Digital Convergence
    • /
    • v.6 no.1
    • /
    • pp.75-82
    • /
    • 2008
  • This paper is aimed to exam factors in the perceived service quality of web portal site and to analyze their effects on customer satisfaction. And this paper analysis satisfaction effects on revisit intention. To accomplish this purpose, this study examined previous studies and summarized core factors of service quality. Form literature survey, we drawn core factors. They are convenience, technologies, valuable of contents and service, communication, positioning. These core factors will affect on customer trust, satisfaction and satisfaction will affect on revisit intention. This study examined previous studies and summarized core factor in perceived service quality of web portal site. Fourteenth hypothesis were developed. Data for empirical testing were collected through survey to portal sites user. The results of this study are as follows; First, we find that service, communication and positioning have positive influence on the trust. Second, convenience, valuable of contents and postioning factors have a positive influence on the satisfaction. Third, it is shown that satisfaction have a positive influence on the revisit intention.

  • PDF

Derivation of preliminary derived concentration guideline levels for surface soil at Kori Unit 1 by RESRAD probabilistic analysis

  • Byon, Jihyang;Park, Sangjune;Ahn, Seokyoung
    • Nuclear Engineering and Technology
    • /
    • v.50 no.8
    • /
    • pp.1289-1297
    • /
    • 2018
  • Preliminary surface soil Derived Concentration Guideline Levels (DCGLs) were derived conforming to the Multi-Agency Radiation Site Survey and Investigation Manual (MARSSIM) procedure for the site release and reuse of Kori Unit 1 in Korea. Based on the decommissioning experiences of the U.S. nuclear power plants, a suite of residual radionuclides was determined, and uncertainties contributed to the resultant dose by the input parameters were quantified via the sensitivity analysis of parameters. The peak of the mean dose was obtained via the probabilistic analysis of the RESRAD (RESidual RADioactivity)-ONSITE code. Consequently, $DCGL_w$ of Kori Unit 1 in accordance with two scenarios, industrial worker and residential farmer scenario, were derived and the results were compared respectively with other NPPs. It could be used as a basic guideline for establishing regulatory standards for reuse planning, designing the site characterization surveys and implementing final status survey (FSS).

A Study on a Installation Siting for GBAS Category-I Ground System Implementation in Gimpo Airport (GBAS Cat-I 지상시스템 시범공항 구축을 위한 설치후보지 검토)

  • Bae, Joong-Won;Jeong, Myeong-Sook;Choi, Chul Hee;Ko, Wan-Jin;Ko, Youri;Jun, Hyang-Sig
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.20 no.4
    • /
    • pp.21-30
    • /
    • 2012
  • This paper presents site survey processes and the results for installing GBAS Category-I ground system into Gimpo international airport. For siting assessment, many things should be taken into account in advance, such as installation requirement of GBAS components, future airport development plan and possible interference effects to existing facilities. Because overall performance of GBAS system can be affected by GPS signal reception environment, on-site survey should be performed carefully to measure actual GPS environmental performance and determine if any adverse multipath or RFI problems exist or not. In addtion, VDB antenna should be located to ensure line of sight for transmitting VHF signal to deliver GBAS message to aircraft. Based on the survey results, final location for GBAS system installation is selected near runway 32 in the Gimpo airport.

3D Resistivity Survey at a Collapsed Tunnel Site (붕락 터널에서의 3차원 전기비저항 탐사)

  • Cho, In-Ky;Kim, Ki-Seog;Lee, Keun-Soo
    • Geophysics and Geophysical Exploration
    • /
    • v.18 no.1
    • /
    • pp.14-20
    • /
    • 2015
  • Three-dimensional (3D) resistivity method is an effective tool in the engineering site survey because it can provide a 3D resistivity distribution of the site. In this study, we tried to find out faults, fractures and coal seams that can cause the collapse of the tunnel. We carried out 2D resistivity survey along 5 parallel lines and 11 cross lines and merged all the apparent resistivity data for 3D inversion. Finally, from the 3D resistivity image and drilling data we presented the 3D distribution of faults, fractures and coal seams that are considered the main cause of the tunnel collapse.