• 제목/요약/키워드: site coefficient

검색결과 715건 처리시간 0.025초

$Pb(Zn_{0.6}Mg_{0.4})_{1/3}Nb_{2/3}O_3$ [PZMN] 계에서 A-자리 치환에 따른 상안정화 및 유전 특성 변화 (Variation of Dielectric Properties and Phase Stabilities with Substitution of A-Site in $Pb(Zn_{0.6}Mg_{0.4})_{1/3}Nb_{2/3}O_3$[PZMN] System)

  • 김봉철;김정주;김남경;조상희
    • 한국세라믹학회지
    • /
    • 제33권10호
    • /
    • pp.1131-1137
    • /
    • 1996
  • The dielectric properties and phase stabilities of Pb(Zn0.6Mg0.4)1/3Nb2/3O3 [PZMN]system were investigated into substitution of A-site with Ba, Sr and Ca ions. The A-site substitutions led to the complexity of components of perovskite phase and then DPT coefficient increased. The A-site substitutions of Ba or Sr ion perovskite single phase could be easily formed by columbite process due to increase of perovskite phase stability. The variation of lattice parameters in specimen obeyed Vegard's law and curie temperature and dielectric constant of specimen decreased linearly. But Ca substitution led to perovskite phae instability. The lattice parameter dielectric constant and curie temperature of specimens drasticaly decreased with formation of pyrochlore phase.

  • PDF

Washout of Tritiated Water Vapor by Precipitation in the Vicinity of Wolsong Nuclear Power Plant Site

  • Kim, C.K.;Lee, S.K.;Rho, B.H.;Park, G.J.;Kim, W.;Kang, H.D.
    • Journal of Radiation Protection and Research
    • /
    • 제28권4호
    • /
    • pp.337-342
    • /
    • 2003
  • On a basis of the washout model and concentrations of anthropogenic tritium in rainwater around the Wolsong site, the washout coefficients of tritium by rainwater were calculated, and the validity of washout deposition model are estimated. As the result of that, the washout coefficients in 10 sampling stations around Wolsong site were in the range of $2.9{\times}10^{-5}\;-\;16{\times}10^{-5}\;s^{-1}$ with the mean value of $7.21{\times}10^{-5}\;s^{-1}$. The validity of the washout deposition model was confirmed by comparing the observed data with the calculated ones.

중앙차선 버스 정류장과 주변지역의 대기오염 특성 비교 (Comparison of Air Pollution Characteristics in the Center Lane-Bus Stop and the Surrounding Areas)

  • 이용기;김웅수;홍순모;신은상
    • 한국대기환경학회지
    • /
    • 제30권4호
    • /
    • pp.378-386
    • /
    • 2014
  • The use of bus stop in the center lane has reduced the emissions of exhaust gas on the road due to the improvement of the traffic speed but has caused a health problem for the citizens who are waiting for the bus in the platform, and thus the air pollution control of bus stop in the center lane is emerging as a more important part. This study was conducted to investigate the air pollution degree for the center lane-bus stops in four regions using mobile air measuring vehicle, and to evaluate the characteristics of air pollution by comparing with the data measured at the urban air monitoring site close to the bus stops. In addition, the correlation analysis was performed to analyze the impact to neighboring region by vehicle exhaust gas. The regional mean concentration of nitrogen dioxide in the center lane-bus stops ranged from 0.025 to 0.043 ppm which shows from 2.5 times to 5.3 times higher than the values of urban air monitoring site selected as a control group. The regional mean concentration of ozone in the center lane-bus stops ranged from 0.023 to 0.034 ppm which shows from 3% to 28% lower than the values of urban air monitoring site selected as a control group. The concentrations of nitrogen dioxide and ozone for the sampling regions did not exceed one hour-air quality environmental standard (0.1 ppm). The mean concentration of particulate matter for four center lane-bus stops was $28{\mu}g/m^3$ which shows about 27% higher than the values of urban air monitoring site selected as a control group, and that of particulate matter did not exceed one day-air quality environmental standard ($100{\mu}g/m^3$). In the results of correlation analysis between data from center lane-bus stops and data from urban air monitoring sites, the correlation coefficient (r) of nitrogen dioxide was relatively low as 0.316 to 0.416, and the correlation coefficient was high as the distance was close and vice versa. However, the correlation coefficient of ozone ranged from 0.167 to 0.658 and the correlation coefficient was high as the distance was far and vice versa.

피에조콘 소산곡선을 이용한 연약지반의 압밀계수 산정 (Estimation of coefficient of consolidation in soft soils using PCPT dissipation results)

  • 서경범;조성환;이준환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1015-1023
    • /
    • 2010
  • While various PCPT-based methods for the analysis of consolidation were developed, additional laboratory test is needed to estimate the coefficient of consolidation. In this paper, hyperbolic method using PCPT dissipation curve for the estimation of coefficient of consolidation was proposed. To verify proposed method, field settlement test data and PCPT dissipation test data at same site were collected and analyzed. It is observed that proposed method shows good agreement with measured field settlement data.

  • PDF

공내재하시험을 이용한 수평하중을 받는 단말뚝의 해석 (Analysis of Laterally Loaded Single Piles using Pressuremeter Test)

  • 이용안;이주형;정문경
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.1051-1060
    • /
    • 2010
  • In this study, the pressuremeter test (PMT) and the standard penetration test (SPT) were performed on the lateral pile loading tests site to evaluate the coefficient of subgrade reaction, which is used for load-deformation behavior analysis of laterally loaded piles by elastic subgrade reaction method. As a result, widely used empirical formulas of the coefficient of subgrade reaction by N values of SPT is evaluated conservatively lateral behavior of piles. While the method of directly used PMT results and evaluation method of the coefficient of subgrade reaction considering deformation moduli of soil and a pile diameter that is able to estimate very similar to actual load-deformation behavior of laterally loaded piles in deformation range of 0.5%-1.0% of a pile diameter.

  • PDF

공기구동 게이트밸브의 운전 성능평가 방법에 관한 연구 (A Evaluation Method of Operational Performance for Air-operated Gate Valve)

  • 김대웅;박성근;강신철;김양석
    • 한국유체기계학회 논문집
    • /
    • 제12권2호
    • /
    • pp.31-38
    • /
    • 2009
  • The valve performance has been evaluated from the theoretical equation based on design information such as packing thrust, spring preload and friction coefficient(${\mu}$). The accuracy of those data can be lower than that of vendor's initial design data. Especially, the friction coefficient can be degraded with time than the original condition and the valve performance calculated using the previous friction coefficient can not be available. Accordingly, this paper is describing a new performance evaluation method of valve based on diagnostic test data which are acquired from a site valve tested in static and dynamic conditions. Especially, this paper provides a new method using friction coefficient(${\mu}$) which is derived from the diagnostic test data acquired in the valve's design basis condition.

빅데이터 지반정보의 불확실성을 고려한 중진지역에서의 액상화 위험도 작성기법 개발 (Development of Mapping Method for Liquefaction Hazard in Moderate Seismic Region Considering the Uncertainty of Big Site Investigation Data)

  • 곽민정;구태진;최재순
    • 한국지반환경공학회 논문집
    • /
    • 제16권1호
    • /
    • pp.17-27
    • /
    • 2015
  • 최근 우리 정부는 안전한 대한민국이라는 슬로건 아래 지진재해를 포함한 자연재해피해를 최소화하는데 많은 노력을 집중하고 있으며, 이를 위해 산사태 위험도와 액상화 위험도와 같은 지진 시 지반피해 GIS 시스템 데이터가 구축되고 있는 실정이다. 우리나라 전역을 포함하는 지진 시 액상화 위험도를 작성하기 위해서는 수많은 지반시추정보에 대한 적용성 검토가 필요하다. 본 연구에서는 액상화 위험도 작성을 위해 인구밀도가 높은 광역지역의 지반증폭계수를 검토하였으며 이를 위해 S시 522개 시추공지반 정보를 수집하여 지반응답해석을 수행하였다. 이때 지반분류는 지반정보의 불확실성을 고려하고자 현행 내진 설계기준에서 제안하고 있는 시추종료 깊이 이후의 지반 정보를 30m로 가정하는 경우와 지반정보의 오리지널 데이터 값만을 이용하는 경우로 나누어 비교하였으며, 타당성 검토 시에는 지반응답해석 결과에 대한 확률분포와 통계분석을 이용하여 수행하였다. 최종적으로 정규분포를 통한 신뢰도 50%, 70%, 90%에 대한 지반증폭계수를 도출하여 액상화 위험도를 도시하였으며, 이를 지반응답해석을 통해 도시한 LPI 액상화 위험도와 비교하여 가장 유사한 값을 추천하였다. 연구결과 제안된 지반증폭계수가 향후 국내 액상화에 대한 연구와 중진지역의 광역지역 액상화 위험도 작성에 큰 도움이 될 수 있을 것으로 기대한다.

국내 지반특성에 적합한 지반분류 방법 및 설계응답스펙트럼 개선에 대한 연구 (III) - 설계응답스펙트럼 개선방법 (Development of Site Classification System and Modification of Design Response Spectra considering Geotechnical Site Characteristics in Korea (III) - Modification of Desing Response Specra)

  • 윤종구;김동수;방은석
    • 한국지진공학회논문집
    • /
    • 제10권2호
    • /
    • pp.63-71
    • /
    • 2006
  • 동반논문(II-지반분류 개선방법)에서는 지반의 고유주기를 기준으로 지반을 분류하는 방법이 국내 지반조건에 적합한 지반분류 방법으로 제시하였다. 그러나, 지반분류 방법을 개선하여도 해석결과의 평균 스펙트럼 가속도 값과 재산정된 응답스펙트럼과 차이가 나타나는 부분이 존재한다. 이는 설계응답스펙트럼을 작성에 필요한 증폭계수를 계산하는 방법을 변경해야 해결할 수 있다. 본 논문에서는 국내 지반조건에 적합하도록 증폭계수를 재산정하기 위한 적분구간 변경에 대하여 검토하였다. 검토 결과 장주기 영역의 증폭계수 $F_v$의 적분구간은 현재 주기 0.4초${\sim}$2.0초에서 주기 0.4초${\sim}$1.5초로 변경할 경우 해석결과의 평균 스펙트럼 가속도 값과 설계응답스펙트럼이 비교적 잘 일치하는 결과를 얻을 수 있었고, 기존의 방법보다 국내 지반특성에 더 적합한 설계응답스펙트럼을 작성할 수 있었다.

기계화시공에 의한 보수재료의 현장품질관리확립을 위한 실험적 연구 (An Experimental Study for Establishment of On-Site Quality Control of Repair Material by the mechanized construction)

  • 조봉석;장재봉;김용로;강석표;홍성윤;김무한
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2004년도 춘계 학술발표회 제16권1호
    • /
    • pp.160-163
    • /
    • 2004
  • In domestic, various repair materials and method systems to keep up with these reinforced concrete deteriorated due to salt damage, carbonation, chemical decay et. developed and applied. However, on-site quality control of various repair materials and method systems isn't achieved desirably because it is depend completely on a men of experience' opinions above all else regardless of various on-site environments. In this background, mock up test with due regard to real on-site environments was performed to secure fundamental data for establishment of desirable on-site quality control. Mock up test using repair mortar analyzed from angles of construction methods, mechanical spraying pressures, W/M. Construction methods were designed manpower method and spraying method, spraying pressures were designed 32, 42, 52 psi, W/M were designed 14.4, 15.4, $16.4\%$. And compressive strength, Chloride ion diffusion coefficient, bond strength, SEM. of mock up test specimens were evaluated. In conclusion, we confirmed excellency of mechanical spraying pressures, fined extremely excellency of condition of spraying pressure 42 ps, W/M $14.4\%$ within this study. therefore the results of this study will be useful to provide fundamental data for establishment of desirable on-site quality control.

  • PDF

시화산업단지의 블록 별 악취유발물질 특성 (Patterns of Offensive Odor Compounds According to Blocks in Shiwha Industrial Complex)

  • 변상훈;이정근;김정근
    • 대한환경공학회지
    • /
    • 제31권12호
    • /
    • pp.1161-1168
    • /
    • 2009
  • 본 연구는 시화공단 단지에서 발생하는 주요 악취물질의 특성을 조사하였다. TVOC의 블록 별 분포를 보면 기계블록인 장소 D의 농도가 74 ppb로 가장 높았다. 화학블록인 장소 A가 그 다음으로 높은 50 ppb의 농도를 보였으며, 복합블록과 금속블록, 공원 등은 30 ppb 내외의 유사한 농도 수준을 보였고, 복합블록인 장소 F에서 평균 TVOC가 18 ppb로 가장 낮게 측정되었다. 평균 TVOC 농도는 35 ppb로 나타났다. 아세트알데히드, 뷰티르알데히드 등을 비롯한 알데히드류와 황화수소의 농도가 시화공단 지역의 악취물질 중에서 높게 나타났다. 대표적으로 악취 강도가 높은 물질인 아세트알데히드, 뷰티르알데히드, 황화수소를 중심으로 블록 별 악취강도를 비교해 본 결과 장소 A, B(화학블록)와 장소 D, I(기계블록), 장소 H(금속블록)에서 세 물질의 악취강도가 모두 1을 넘었다. 아세트알데히드의 경우 악취강도가 2 내외로 비교적 높게 나타나는 경우가 많았다. 황화수소의 경우 상관계수의 값이(r) 0.91로 악취강도와 황화수소 성분 사이에 매우 높은 양의 상관성이 있는 것으로 확인되었다. 뷰티르알데히드도 상관계수가 0.82로 역시 높은 양의 상관성을 보였다. 악취물질 농도로는 가장 큰 값을 보였던 아세트알데히드는 상관계수가 0.62로 악취강도와 어느 정도의 상관성이 있는 것으로 나타났다.