• Title/Summary/Keyword: sinusoidal distortion

Search Result 115, Processing Time 0.019 seconds

Novel Buck Mode Three-Level Direct AC Converter with a High Frequency Link

  • Li, Lei;Guan, Yue;Gong, Kunshan;Li, Guangqiang;Guo, Jian
    • Journal of Power Electronics
    • /
    • v.18 no.2
    • /
    • pp.407-417
    • /
    • 2018
  • A novel family of Buck mode three-level direct ac converters with a high frequency link is proposed. These converters can transfer an unsteady high ac voltage with distortion into a regulated sinusoidal voltage with a low THD at the same frequency. The circuit configuration is constituted of a three-level converter, high frequency transformer, cycloconverter, as well as input and output filters. The topological family includes forward, push-pull, half-bridge, and full-bridge modes. In order to achieve a reliable three-level ac-ac conversion, and to overcome the surge voltage and surge current of the cycloconverter, a phase-shifted control strategy is introduced in this paper. A prototype is presented with experimental results to demonstrate that the proposed converters have five advantages including high frequency electrical isolation, lower voltage stress of the power switches, bi-directional power flow, low THD of the output voltage, and a higher input power factor.

HIGH SPEED VARIABLE SQUARE WAVE AC SUBMERGED ARC WELDING -FREQUENCY/BALANCE STUDY .250″ PLAIN CARBON STEEL

  • Reynolds, Jon-O;Sean P. Moran
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.361-365
    • /
    • 2002
  • Advancements in silicon phase control (SCR) technologies provide an arc welding power supply that has the capability to allow the alteration of the Alternating Current (AC) welding output. These technologies provide a square wave output involving sixteen frequency selections and multiple balance selections. While an AC out put is known to minimize magnetic disturbances associate with Direct Current (DC), the potentials of a non-sinusoidal waveform have not been explored. The focus of the paper is to determine the effects that the frequency and balance of an AC wave form output will have upon a high speed Submerge Arc (SAW) application. The test matrix of the project includes welding .250" steel plate. Joint type is square groove with a travel speed of 65 IPM. Each of the weld parameters was held constant, only the frequency and/or balance were altered between welds. Each frequency/balance combination involved three-gap spacing. Upon completion of the welds the bead profiles were measured and recorded. A relationships/trends were observed with various frequency and balance values. Optimum frequency and balance values were found for the .250" square groove application which permit consistent weld sizing, ease of slag removal, and minimal plate distortion.

  • PDF

Phase calcuation error analysis of 3D shape measurement system using phase-shifted fringe projection method (위상이동 간섭무늬 투영을 이용한 3차원 형상측정 시스템의 위상계산오차 해석)

  • 류현미;김석성;홍석경;연규황
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.182-188
    • /
    • 2002
  • We have analyzed the phase-calculation-error of a three-dimensional shape measurement system using the projection of phase shifted fringe patterns. In this study, we have dealt various errors; an error caused by the variation of quantization levels, an error caused by the defocus of fringe pattern projected images, an error caused by phase-shifting errors, an error caused by the intensity variation of the background and modulation amplitude of fringe pattern projected images during the projection of multiple patterns, an error caused by the distortion of sinusoidal shape of a fringe pattern. The results will contribute to the design of a three-dimensional shape measurment system and give an important meaning to the calculation and the analysis of the accuracy of a system.

A Study of Buck-Boost Current-Source PWM Inverter for Utility Interactive Photovoltaic Generation System (태양광발전과 계통연계를 위한 Buck-Boost 전류원형 PWM 인버터에 관한 연구)

  • Yang Geun-Ryoung;Kang Feel-Soon;Kim Cheul-U
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.63-68
    • /
    • 2002
  • In a utility interactive photovoltaic generation system, a PWM inverter is used for the connection between the photovoltaic arrays and the utility. The do current becomes pulsated when the conventional inverter system operates in the continuous current mode and dc current pulsation causes the distortion of the ac current waveform. To reduce pulsation of dc input current, This paper presents a Buck-Boost PWM power inverter and its application for residential photovoltaic system. The PWM power inverter is realized by combining two sets of a high frequency Buck-Boost chopper and by making it operate in the discontinuous conduction mode. In this paper, we show the Buck-Boost PWM power inverter circuit, its equivalent circuit and basic differential equations and the power flow characteristics are clarified when the proposed Inverter is interconnected with the utility lines. In conclusion, the proposed inverter system provides a sinusoidal ac current for domestic loads and the utility line with unity power factor

  • PDF

The Effect of Asynchronous Carrier on Matrix Converter Characteristics

  • Oyama, Jun;Higuchi, Tsuyoshi;Abe, Takashi;Yamada, Eiji;Hayashi, Hideki;Koga, Takashi
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.512-517
    • /
    • 1998
  • In a matrix converter, input side and output side are coupled with each other through switching elements. Since disturbances on either side affect directly on the other side, it requires a high-speed on-line control system to compensate them. We proposed in previous papers a new control strategy and an on-line control circuit for a matrix converter. The control circuit could keep the output voltage at commanded value against fluctuation in the supply voltage. Furthermore wave forms of the output voltage and the input current were always kept sinusoidal. The switching pattern was generated by comparing modified voltage references with a carrier. The carrier was synchronized with the supply voltage using a PLL system, which made the control circuit complicated and costly. This paper discusses on the possibility of an asynchronized carrier. Experiment results show the input current distortion in case of asynchronous carrier is bigger than that of synchronous carrier. However, the deterioration can be minimized by increased carrier frequency.

  • PDF

Hardware-Based Implementation of a PIDR Controller for Single-Phase Power Factor Correction

  • Le, Dinh Vuong;Park, Sang-Min;Yu, In-Keun;Park, Minwon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.21 no.4
    • /
    • pp.21-30
    • /
    • 2016
  • In a single-phase power factor correction (PFC), the standard cascaded control algorithm using a proportional-integral-derivative (PID) controller has two main drawbacks: an inability to track sinusoidal current reference and low harmonic compensation capability. These drawbacks cause poor power factor and high harmonics in grid current. To improve these drawbacks, this paper uses a proportional-integral-derivative-resonant (PIDR) controller which combines a type-III PID with proportional-resonant (PR) controllers in the PFC. Based on a small signal model of the PFC, the type-III PID controller was implemented taking into account the bandwidth and phase margin of the PFC system. To adopt the PR controllers, the spectrum of inductor current of the PFC was analyzed in frequency domain. The hybrid PIDR controller were simulated using PSCAD/EMTDC and implemented on a 3 kW PFC prototype hardware. The performance results of the hybrid PIDR controller were compared with those of an individual type-III PID controller. Both controllers were implemented successfully in the single-phase PFC. The total harmonic distortion of the proposed controller were much better than those of the individual type-III PID controller.

A Study on the Harmonics Measurement, Assessment and Resonant Filter Application of the Electric Arc Furnace Loads (전기로 부하의 고조파 측정, 평가 및 동조필터 적용에 관한 연구)

  • Kim, Kyung-Chul;Jin, Seong-Eun;Lee, Joo-Hong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.6
    • /
    • pp.35-42
    • /
    • 2006
  • Large steel industries have nonlinear loads including electric arc furnaces. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. This paper provides an in depth analysis on harmonics field measurement of the electric arc furnace loads, adding a single-tuned filter at the customer bus for reducing harmonic distortion and harmonics assessment by the international harmonic standards IEC 61000-3-6 and IEEE Std. 519. The EDSA program was used as a simulation tool for the case study.

A Survey of the Harmonics Level on a Typical Household Loads by Field Measurements (현장 측정에 의한 일반 가정집 부하의 고조파 수준 조사)

  • Kim, Kyung-Chul;Oh, Kyung-Hoon;Choi, Hyoung-Bumb;Hong, Sa-Guen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.5
    • /
    • pp.95-102
    • /
    • 2008
  • Typical household loads have nonlinear loads including a personal computer, video, refrigerator, microwave oven, TV, and audio set. These nonlinear loads generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probablistic approach is the most commonly used method to solve time varying harmonics. This paper provides in depth analysis on harmonics field measurement of the typical household loads for one year period and the survey is conducted with the objectives to identify the trends of harmonic distortion level present and indentify the future trends of metering in the presence of nonsinusoidal current and voltage waveforms in the system.

Design and Implementation of Digital Electrical Impedance Tomography System (디지털 임피던스 영상 시스템의 설계 및 구현)

  • 오동인;백상민;이재상;우응제
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.269-275
    • /
    • 2004
  • Different biological tissues have different values of electrical resistivity. In EIT (electrical impedance tomography), we try to provide cross-sectional images of a resistivity distribution inside an electrically conducting subject such as the human body mainly for functional imaging. However, it is well known that the image reconstruction problem in EIT is ill-posed and the quality of a reconstructed image highly depends on the measurement error. This requires us to develop a high-performance EIT system. In this paper, we describe the development of a 16-channel digital EIT system including a single constant current source, 16 voltmeters, main controller, and PC. The system was designed and implemented using the FPGA-based digital technology. The current source injects 50KHz sinusoidal current with the THD (total harmonic distortion) of 0.0029% and amplitude stability of 0.022%. The single current source and switching circuit reduce the measurement error associated with imperfect matching of multiple current sources at the expense of a reduced data acquisition time. The digital voltmeter measuring the induced boundary voltage consists of a differential amplifier, ADC, and FPGA (field programmable gate array). The digital phase-sensitive demodulation technique was implemented in the voltmeter to maximize the SNR (signal-to-noise ratio). Experimental results of 16-channel digital voltmeters showed the SNR of 90dB. We used the developed EIT system to reconstruct resistivity images of a saline phantom containing banana objects. Based on the results, we suggest future improvements for a 64-channel muff-frequency EIT system for three-dimensional dynamic imaging of bio-impedance distributions inside the human body.

New Isolated Zero Voltage Switching PWM Boost Converter (새로운 절연된 영전압 스위칭 PWM 부스트 컨버터)

  • Cho, Eun-Jin;Moon, Gun-Woo;Jung, Young-Suk;Youn, Myung-Joong
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.535-538
    • /
    • 1994
  • In this paper, an isolated ZVS-PWM boost converter is proposed for single stage line conversion. For power factor correction, we used the half bridge topology at the primary side of isolation transformer permitting switching devices to operate under ZVS by using circuit parastics and operating at a fixed duty ratio near 50%. Thus the relatively continuous input current distortion and small size input filter are also achievable. The ZVS-PWM boost operation of the proposed converter can be achieved by using the boost inductor $L_f$, main switch $Q_3$, and simple auxiliary circuit at the secondary side of isolation transformer. The secondary side circuit differ from a conventional PWM boost converter by introduction a simple auxiliary circuit. The auxiliary circuit is actived only during a short switching transition time to create the ZVS condition for the main switch as that of the ZVT-PWM boost converter. With a single stage, it is possible to achieve a sinusoidal line current at unity power factor as well as the isolated 48V DC output. Comparing to the two stage schemes, overall effiency of the proposed converter is highly improved due to the effective ZVS of all devices as well as single stage power conversion. Thus, it can be operated at high switching frequency allowing use of small size input filter. Minimum voltage and current stress make it high power application possible.

  • PDF