• 제목/요약/키워드: single-pass

검색결과 485건 처리시간 0.025초

Kinematical Aspects Gliding Technique in 500-m Speed Skaters: From Start to Seven Strokes

  • Ryu, Jae Kyun;Kim, Young Suk;Hong, Sung Hong
    • Korean Journal of Applied Biomechanics
    • /
    • 제26권4호
    • /
    • pp.333-341
    • /
    • 2016
  • Objective: The purpose of this study was to assess the consistency of the gliding and push-off motion for single leg skating from the first to fourteenth steps. We hypothesized that: 1) there would be no difference in stroke trajectory, step rate, and cycle rate between the left and right steps of gliding; and 2) there would be a difference in the resultant velocity of toe push-off and the horizontal velocity of the center of mass after six step push-offs. Method: The study included five male 500-m speed skaters (mean height, $1.80{\pm}0.02m$; mean weight, $76.8{\pm}3.96kg$; record, $35.83{\pm}0.30sec$; 100-m record, <9.97 sec). Data were collected from the first to fourteenth steps (40 m) and recorded using five digital JVC GR-HD1KR video cameras (Victor Co., Japan) operating at a sampling frequency of 60 fields/sec and shutter speed of 1/500 sec. For each film frame, the joint positions were digitized using the KWON3D motion analyzer. Position data were filtered with low-pass Butterworth $4^{th}$ order at the cut-off frequency of 7.4 Hz. Results: The right toe of the skating trajectories at $2^{nd}$, $5^{th}$, and $7^{th}$ strokes differed from those of the left toe. The angles of the right and left knee demonstrated unbalanced patterns from the flexion and extension legs. The step and cycle rates of the right and left leg differed from the start until 20 m. The resultant velocities of the toe at the push-off phase and of the body mass center diverged before the six push-offs. Conclusion: This study's findings indicate that the toe of skating trajectory on left and right sliding after push-off should maintain a symmetrical trajectory. The resultant velocity of toe push-off and horizontal velocity from the center of body need to be separated after about six step push-offs.

Characterization of Expressed Sequence Tags (ESTs) Generated from the Bombyx mandarina Whole Larvae and Molecular Cloning of Serine Protease Homologue Gene

  • Hwang, Jae Sam;Yun, Eun Young;Goo, Tae Won;Kim, Iksoo;Choi, Kwang Ho;Seong, Su Il;Kim, Keun Young;Lee, Sang Mong;Kang, Seok Woo
    • International Journal of Industrial Entomology and Biomaterials
    • /
    • 제9권2호
    • /
    • pp.167-171
    • /
    • 2004
  • We constructed an oligo-d(T) primed directional cDNA library from the Bombyx mandarina whole larvae. In an effort to isolate genes expressed in the B. mandarina, 227 expressed sequence tags (ESTs) were generated by single-pass sequencing from the cDNA library. Sequence analysis showed that 107 clones (47.1%) were classified into known genes and 120 clones (52.9%) were novel transcripts, which are unknown for their function. Of the 107 known genes, the most abundant gene was found to be actin and followed by serine protease in the expression profile. Among these clones, a serine protease homolog (BmSP) which is a class of proteolytic enzymes isolated. Full-length sequence of the BmSP cDNA clone was 922 bp in length and has an open reading frame of 276 amino acids. The conserved histidine, aspatic acid and serine residues forming the catalytic center as well as cysteine residues contributing to three disulphide bonds also were found in Bmsp gene. mRNA expression analysis revealed a high and specific expression of the gene only in midgut tissue, suggesting that BmSP gene is closely associated with the expression of digestive enzyme.

Effects of Hydrocortisone on the Pharmacokinetics of Loratadine after Oral and Intravenous Loratadine Administration to Rats

  • Choi, Jun-Shik;Choi, In;Burm, Jin-Pil
    • Biomolecules & Therapeutics
    • /
    • 제17권2호
    • /
    • pp.205-210
    • /
    • 2009
  • The present study investigated the effects of hydrocortisone on the pharmacokinetics of loratadine in rats after intravenous and oral administration. A single dose of loratadine was administered either orally (4 mg/kg) or intravenously (1 mg/kg) with or without oral hydrocortisone (0.3 or 1.0 mg/kg). Compared to the control group (without hydrocortisone), after oral administration of loratadine, the area under the plasma concentration-time curve (AUC) was significantly increased by 30.2-81.7% in the presence of hydrocortisone (p<0.05). The peak plasma concentration ($C_{max}$) was significantly increased by 68.4% in the presence of 1.0 mg/kg hydrocortisone after oral administration of loratadine (p<0.05). Hydrocortisone (1.0 mg/kg) significantly increased the terminal plasma half-life ($t_{1/2}$) of loratadine by 20.8% (p<0.05). Consequently, the relative bioavailability of loratadine was increased by 1.30- to 1.82-fold. In contrast, oral hydrocortisone had no effects on any pharmacokinetic parameters of loratadine given intravenously. This suggests that hydrocortisone may improve the oral bioavailability of loratadine by reducing first-pass metabolism of loratadine, most likely mediated by P-gp and/or CYP3A4 in the intestine and/or liver. In conclusion, hydrocortisone significantly enhanced the bioavailability of orally administered loratadine in rats, which may have been due to inhibition of both CYP 3A4-mediated metabolism and P-gp in the intestine and/or liver by the presence of hydrocortisone.

3D Face Modeling from a Frontal Face Image by Mesh-Warping (메쉬 워핑에 의한 정면 영상으로부터의 3D 얼굴 모델링)

  • Kim, Jung-Sik;Kim, Jin-Mo;Cho, Hyung-Je
    • Journal of Korea Multimedia Society
    • /
    • 제16권1호
    • /
    • pp.108-118
    • /
    • 2013
  • Recently the 3D modeling techniques were developed rapidly due to rapid development of computer vision, computer graphics with the excellent performance of hardware. With the advent of a variety of 3D contents, 3D modeling technology becomes more in demand and it's quality is increased. 3D face models can be applied widely to such contents with high usability. In this paper, a 3D face modeling is attempted from a given single 2D frontal face image. To achieve the goal, we thereafter the feature points using AAM are extracted from the input frontal face image. With the extracted feature points we deform the 3D general model by 2-pass mesh warping, and also the depth extraction based on intensity values is attempted to. Throughout those processes, a universal 3D face modeling method with less expense and less restrictions to application environment was implemented and it's validity was shown through experiments.

An Efficient Computation of Matrix Triple Products (삼중 행렬 곱셈의 효율적 연산)

  • Im, Eun-Jin
    • Journal of the Korea Society of Computer and Information
    • /
    • 제11권3호
    • /
    • pp.141-149
    • /
    • 2006
  • In this paper, we introduce an improved algorithm for computing matrix triple product that commonly arises in primal-dual optimization method. In computing $P=AHA^{t}$, we devise a single pass algorithm that exploits the block diagonal structure of the matrix H. This one-phase scheme requires fewer floating point operations and roughly half the memory of the generic two-phase algorithm, where the product is computed in two steps, computing first $Q=HA^{t}$ and then P=AQ. The one-phase scheme achieved speed-up of 2.04 on Intel Itanium II platform over the two-phase scheme. Based on memory latency and modeled cache miss rates, the performance improvement was evaluated through performance modeling. Our research has impact on performance tuning study of complex sparse matrix operations, while most of the previous work focused on performance tuning of basic operations.

  • PDF

Improved Plasmonic Filter, Ultra-Compact Demultiplexer, and Splitter

  • Rahimzadegan, Aso;Granpayeh, Nosrat;Hosseini, Seyyed Poorya
    • Journal of the Optical Society of Korea
    • /
    • 제18권3호
    • /
    • pp.261-273
    • /
    • 2014
  • In this paper, metal insulator metal (MIM) plasmonic slot cavity narrow band-pass filters (NBPFs) are studied. The metal and dielectric of the structures are silver (Ag) and air, respectively. To improve the quality factor and attenuation range, two novel NBPFs based on tapered structures and double cavity systems are proposed and numerically analyzed by using the two-dimensional (2-D) finite difference time domain (FDTD) method. The impact of different parameters on the transmission spectrum is scrutinized. We have shown that increasing the cavities' lengths increases the resonance wavelength in a linear relationship, and also increases the quality factor, and simultaneously the attenuation of the wave transmitted through the cavities. Furthermore, increasing the slope of tapers of the input and output waveguides decreases attenuation of the wave transmitted through the waveguide, but simultaneously decreases the quality factor, hence there should be a trade-off between loss and quality factor. However, the idea of adding tapers to the waveguides' discontinuities of the simple structure helps us to improve the device total performance, such as quality factor for the single cavity and attenuation range for the double cavity. According to the proposed NBPFs, two, three, and four-port power splitters functioning at 1320 nm and novel ultra-compact two-wavelength and triple-wavelength demultiplexers in the range of 1300-1550 nm are proposed and the impacts of different parameters on their performances are numerically investigated. The idea of using tapered waveguides at the structure discontinuities facilitates the design of ultra-compact demultiplexers and splitters.

Case study of Hexavalent Chromium and Silica Exposure Assessment and Respiratory Fit-test for Paint Manufacturing Worker (페인트 제조 작업자의 6가 크롬 및 실리카 노출평가와 호흡보호구 밀착도 검사 사례)

  • Lee, Hyun Seok;Kim, Boowook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • 제31권4호
    • /
    • pp.295-303
    • /
    • 2021
  • Objective: Paint manufacturing industry workers are exposed to various lung cancer carcinogenic substances including hexavalent chromium and crystalline silica. Studies have been conducted on lung cancer in Paint manufacturing industry workers and the concentration of hexavalent chromium in paint industry; however, the concentration of crystalline silica and hexavalent chromium and cases of lung cancer in a single Paint factory has never been reported in Korea. Methods: To determine whether the cancer was related to his work environment, we assessed the level of exposure to carcinogens during pouring and mixing talc and pigment. In addition, a mask fit test was performed for the worker. Results: Analysis of talc and silica bulk powder materials showed that crystalline silica (quartz) was 5% in talc and 100% in silica. The green and yellow pigments contained 87% and 92% of lead chromate, respectively. Our quantitative analysis of pigment powder samples showed that the hexavalent chromium contents quantified in the green and yellow pigment samples were 87% and 92%, respectively. In order to estimate his exposure level of hexavalent chromium, we measured a personal exposure level of hexavalent chromium for a worker in accordance with the National Institute for Occupational Safety and Health #7605 method. The results showed that the worker was exposed to the high level of hexavalent chromium (0.033 mg m-3). In addition, the talc powder also contained 5% quartz, and the worker's exposure level to respirable quartz exceeded OEL. As a result of the respiratory protection fit test for workers, the overall Fit Factor was '15' when wearing a second-grade mask and '25' when wearing a first-grade mask, significantly lower than the US Occupational Safety and Health Agency (OSHA) pass value of "100". Conclusion: Workers who pouring and mixing powder materials such as talc or colored pigments in paint manufacturing company may be exposed to high concentrations of carcinogenic substances. These findings indicate that it is necessary to local ventilation system inspection, safety and health education for employers and workers, and periodically monitoring and manage the working environment.

Ionospheric Responses to the Earthquake in the Gulf of Alaska and the Kusatsu-Shiranesan Volcanic Eruption on 23 January 2018

  • Shahbazi, Anahita;Park, Jihye
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제11권4호
    • /
    • pp.305-316
    • /
    • 2022
  • Numerous research revealed a strong association between the ionospheric perturbations and various natural hazards. The ionospheric measurements from Global Navigation Satellite System (GNSS) observations provide the state of electron contents in the ionosphere that contributes to investigate the source events. In this study, two geophysical events occurred on 23 January 2018, the 7.9 Mw earthquake in Alaska and Kusatsu-Shiranesan volcanic eruption in Japan, are examined to characterize the fingerprint of each event in the ionosphere. Firstly, we extracted the Total Electron Content (TEC) from GNSS measurements, then isolated disturbed wave signatures from the TEC measurements that is referred to as a traveling ionospheric disturbance (TID). As TIDs are short-term ionospheric variations, the major trend of GNSS TEC measurements should be properly removed. We applied a natural neighbor interpolation method together with a leave-one-out cross validation technique for detrending. After detrending the TEC, the remaining signals are further enhanced by applying a band-pass filter and TIDs are detected from them. Finally, the detected TIDs are verified as the response of the ionosphere to Kusatsu-Shiranesan volcanic eruption and Gulf of Alaska earthquake which propagated through the ionosphere with an average velocity of 530 m/s and 724 m/s, respectively. In addition, a coherence analysis is conducted to discriminate between the signatures from a volcanic explosion and an earthquake. The analysis reveals the TID waveforms from each single event are highly correlated, while a low correlation is found between the TIDs from the earthquake and explosion. This study supports the claim that different geophysical events induce the distinctive characteristics of TIDs that are detectable by the ionospheric measurements of GNSS.

A Study on the Cost of Capital of Islamic Enterprise (이슬람기업의 자본조달비용에 관한 연구)

  • Choi, Tae-Yeong
    • International Area Studies Review
    • /
    • 제13권2호
    • /
    • pp.505-523
    • /
    • 2009
  • We study the cost of capital of Islamic enterprise using the Capital Asset Pricing Model(CAPM). When there exists no risk-free interest rate, the security market line(SML) of Islamic enterprise shows an upward slope starting from the origin. The slope is bigger than that of SML with risk-free interest rate. This is because the cost of capital of Islamic enterprise is higher than that of western firms for the same level of systematic risk. When the effect of zakat is considered, the risk-free interest rate is replaced by minimum required rate of return. The SML of Islamic enterprise reveals an upward slope but it does not pass through the origin. This is because Islamic enterprise cannot invest on risk-free asset. In order to overcome the theoretic limits of CAPM, we propose to use multi-factor approach such as arbitrage pricing model instead of single-factor model for future study.

Glass Dissolution Rates From MCC-1 and Flow-Through Tests

  • Jeong, Seung-Young
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 한국방사성폐기물학회 2004년도 학술논문집
    • /
    • pp.257-258
    • /
    • 2004
  • The dose from radionuclides released from high-level radioactive waste (HLW) glasses as they corrode must be taken into account when assessing the performance of a disposal system. In the performance assessment (PA) calculations conducted for the proposed Yucca Mountain, Nevada, disposal system, the release of radionuclides is conservatively assumed to occur at the same rate the glass matrix dissolves. A simple model was developed to calculate the glass dissolution rate of HLW glasses in these PA calculations [1]. For the PA calculations that were conducted for Site Recommendation, it was necessary to identify ranges of parameter values that bounded the dissolution rates of the wide range of HLW glass compositions that will be disposed. The values and ranges of the model parameters for the pH and temperature dependencies were extracted from the results of SPFT, static leach tests, and Soxhlet tests available in the literature. Static leach tests were conducted with a range of glass compositions to measure values for the glass composition parameter. The glass dissolution rate depends on temperature, pH, and the compositions of the glass and solution, The dissolution rate is calculated using Eq. 1: $rate{\;}={\;}k_{o}10^{(ph){\eta})}{\cdot}e^{(-Ea/RT)}{\cdot}(1-Q/K){\;}+{\;}k_{long}$ where $k_{0},\;{\eta}$ and Eaare the parameters for glass composition, pH, $\eta$ and temperature dependence, respectively, and R is the gas constant. The term (1-Q/K) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_{0},\;{\eta}\;and\;E_{a}$ are the parameters for glass composition, pH, and temperature dependence, respectively, and R is the gas constant. The term (1-Q/C) is the affinity term, where Q is the ion activity product of the solution and K is the pseudo-equilibrium constant for the glass. Values of the parameters $k_0$, and Ea are determined under test conditions where the value of Q is maintained near zero, so that the value of the affinity term remains near 1. The dissolution rate under conditions in which the value of the affinity term is near 1 is referred to as the forward rate. This is the highest dissolution rate that can occur at a particular pH and temperature. The value of the parameter K is determined from experiments in which the value of the ion activity product approaches the value of K. This results in a decrease in the value of the affinity term and the dissolution rate. The highly dilute solutions required to measure the forward rate and extract values for $k_0$, $\eta$, and Ea can be maintained by conducting dynamic tests in which the test solution is removed from the reaction cell and replaced with fresh solution. In the single-pass flow-through (PFT) test method, this is done by continuously pumping the test solution through the reaction cell. Alternatively, static tests can be conducted with sufficient solution volume that the solution concentrations of dissolved glass components do not increase significantly during the test. Both the SPFT and static tests can ve conducted for a wide range of pH values and temperatures. Both static and SPFt tests have short-comings. the SPFT test requires analysis of several solutions (typically 6-10) at each of several flow rates to determine the glass dissolution rate at each pH and temperature. As will be shown, the rate measured in an SPFt test depends on the solution flow rate. The solutions in static tests will eventually become concentrated enough to affect the dissolution rate. In both the SPFt and static test methods. a compromise is required between the need to minimize the effects of dissolved components on the dissolution rate and the need to attain solution concentrations that are high enough to analyze. In the paper, we compare the results of static leach tests and SPFT tests conducted with simple 5-component glass to confirm the equivalence of SPFT tests and static tests conducted with pH buffer solutions. Tests were conducted over the range pH values that are most relevant for waste glass disssolution in a disposal system. The glass and temperature used in the tests were selected to allow direct comparison with SPFT tests conducted previously. The ability to measure parameter values with more than one test method and an understanding of how the rate measured in each test is affected by various test parameters provides added confidence to the measured values. The dissolution rate of a simple 5-component glass was measured at pH values of 6.2, 8.3, and 9.6 and $70^{\circ}C$ using static tests and single-pass flow-through (SPFT) tests. Similar rates were measured with the two methods. However, the measured rates are about 10X higher than the rates measured previously for a glass having the same composition using an SPFT test method. Differences are attributed to effects of the solution flow rate on the glass dissolution reate and how the specific surface area of crushed glass is estimated. This comparison indicates the need to standardize the SPFT test procedure.

  • PDF