• Title/Summary/Keyword: single-pass

Search Result 480, Processing Time 0.033 seconds

Novel Fast Peak Detector for Single- or Three-phase Unsymmetrical Voltage Sags

  • Lee, Sang-Hoey;Cha, Han-Ju
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.658-665
    • /
    • 2011
  • In the present paper, a novel fast peak detector for single- or three-phase unsymmetrical voltage sags is proposed. The proposed detector is modified from a single-phase digital phase-locked loop based on a d-q transformation using an all-pass filter (APF). APF generates a virtual phase with $90^{\circ}$ phase delay. However, this virtual phase cannot reflect a sudden change of the grid voltage in the moment of voltage sag, which causes a peak value to be significantly distorted and to settle down slowly. Specifically, the settling time of the peak value is too long when voltage sag occurs around a zero crossing, such as phase $0^{\circ}$ and $180^{\circ}$. This paper describes the operating principle of the APF problem and proposes a modified all-pass filter (MAPF) to mitigate the inherent APF problem. In addition, a new fast peak detector using MAPF is proposed. The proposed detector is able to calculate a peak value within 0.5 ms, even when voltage sag occurs around zero crossing. The proposed fast peak detector is compared with the conventional detector using APF. Results show that the proposed detector has faster detection time in the whole phase range. Furthermore, the proposed fast peak detector can be effectively applied to unsymmetrical three-phase voltage sags. Simulation and experimental results verify the advantages of the proposed detector and MAPF.

Delay Measurement and Split-Step Time-Domain Analysis of Ring Resonator All-Pass Filters

  • Kim, Hyosuk;Ko, Yoonyoung;Moon, Hyunseung;Kim, Jaeseong;Chung, Youngchul
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.6
    • /
    • pp.766-771
    • /
    • 2014
  • Single-ring all-pass filters with various coupling ratios are designed, fabricated, and characterized to assess the validity of the split-step time-domain modeling approach, which is considered for direct simulation of time-domain characteristics, such as optical delay, of various ring resonator devices. When the coupling ratio of the single-ring all-pass filter is 0.4 and 0.8, the delay time is measured to be about 145 and 42 ps respectively, which is comparable to the time-domain modeling results of 151 and 47 ps respectively. The measurements for two- and three-ring all-pass filters are also found to agree quite well with the simulation results. With these results it is confirmed that the split-step time-domain model could be efficiently incorporated into an optical-communication simulation module for ring resonator delay components in an all-optical packet switching system.

Determination of Forward Dissolution Rate of Glass by a Single-Pass Flow-Through Test (Single-Pass Flow-Through Test방법에 의한 유리의 정용해율 측정)

  • Kim Seung-Soo;Chun Kwan-Sik;Choi Jong-Won;Kim Sung-Ki;Hahn Pil-Soo
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.335-340
    • /
    • 2005
  • The forward dissolution rate of a borosilicate waste glass was determined as an interlaboratory study(ILS) testing program for the evaluation of precision in the measurement of the dissolution rate or a waste glass using a single-pass flow-through(SPFT) test, whose conducting practice has been written for standardization through American Society for Testing and Materials (ASTM). A simulated low-activity waste glass powder with a size of 100/200 mesh was dissolved by lithium buffer solution (pH=10) at 70? under Ar atmosphere. By plotting the dissolution rates as a function of silicon and boron concentration in eluate, the forward dissolution rate of the glass was obtained as about $2.7\times10^{-5}g{\cdot}m{\cdot}s^{-1}$ in our laboratory.

  • PDF

Effect of Amoxicillin on the Intestinal Membrane Permeability and Absorption Clearance of Benazepril (베나제프릴의 장관막 투과도와 흡수 클리어런스에 미치는 아목시실린의 영향)

  • Joo, Eun-Hee;Kim, Young-Man;Ko, Hyung-Seok;Lee, Yong-Bok;Na, Han-Kwang
    • Journal of Pharmaceutical Investigation
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 1998
  • Intestinal absorption of ${\beta}-lactam$ antibiotics and angiotensin converting enzyme(ACE) inhibitors has been shown to use the carrier-mediated transport system. In vitro experiments have established that the efficacy of uptake by enterocytes depends on an inwardly directed proton gradient. It was suggested that benazepril was mediated by tripeptide transport system and that amoxicillin was transported by dipeptide transport carrier. The aim of this study is to assess the influence of amoxicillin on the intestinal absorption of benazepril using in vitro diffusion chamber and in situ single pass perfusion technique in the rat in order to elucidate whether the above transport systems are competitive or not. We obtained the gastrointestinal pemeability coefficient of amoxicillin, benazepril and both of them using in vitro diffusion chamber. And also the gastrointestinal absorption clearance of amoxicillin, benazepril and both of them using in situ single-pass perfusion method at steady state were calculated. Amoxicillin and benazepril were analyzed by HPLC. The results by the use of diffusion chamber in vitro indicated that the apparent intestinal permeability coefficient of benazepril was significantly(p<0.01) decreased by amoxicillin(45.2%) and vice versa significantly(p<0.01) decreased(89.1%). The results by the in situ gastrointestinal single-pass perfusion method indicated that the intestinal absorption clearance of benazepril was significantly(p<0.05) decreased by amoxicillin (40.2%) and vice versa significantly(p<0.05) decreased(54.8%). These results might suggest that they share the same peptide carrier pathway for oral absorption.

  • PDF

The Multipass Joint Tracking System by Vision Sensor (비전센서를 이용한 다층 용접선 추적 시스템)

  • Lee, Jeong-Ick;Koh, Byung-Kab
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.5
    • /
    • pp.14-23
    • /
    • 2007
  • Welding fabrication invariantly involves three district sequential steps: preparation, actual process execution and post-weld inspection. One of the major problems in automating these steps and developing autonomous welding system is the lack of proper sensing strategies. Conventionally, machine vision is used in robotic arc welding only for the correction of pre-taught welding paths in single pass. However, in this paper, multipass tracking more than single pass tracking is performed by conventional seam tracking algorithm and developed one. And tracking performances of two algorithm are compared in multipass tracking. As the result, tracking performance in multi-pass welding shows superior conventional seam tracking algorithm to developed one.

PLL Method Using The Improved Discrete Fourier Transform (개선된 DFT를 이용한 위상 추종방법)

  • Kim, Jae-Hyung;Ji, Young-Hyok;Won, Chung-Yuen;Jung, Yong-Chae
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.91-93
    • /
    • 2008
  • In this paper, novel phase angle following algorithm for the single phase grid-connected inverter is proposed. Gird-connected inverter needs phase angle detection for synchronization grid voltage with the inverter output. In case of single phase grid-connected inverter, zero crossing detection and virtual 2-phase PLL using digital all pass filter or digital low pass filter are used conventionally. But these methods have a weakness for harmonics, noises and ripples. The proposed method of PLL achieve DFT(Discrete Fourier Transform) using Goertzel algorithm. It can extract fundamental voltage of grid. As a results, it can obtain phase angle using digital all pass filter without effect of harmonics, noises and ripples. Simulation results are presented to demonstrate the effectiveness of the proposed algorithm.

  • PDF

Improved Self Plasma-Optical Emission Spectroscopy for In-situ Plasma Process Monitoring (실시간 플라즈마공정 모니터링을 위한 Self Plasma-Optical Emission Spectroscopy 성능 향상)

  • Jo, Kyung Jae;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.2
    • /
    • pp.75-78
    • /
    • 2017
  • We reports improved monitoring performance of Self plasma-optical emission spectroscopy (SP-OES) by augmenting a by-pass tube to a conventional straight (or single) tube type self plasma reactor. SP-OES has been used as a tool for the monitoring of plasma chemistry indirectly in plasma process system. The benefits of SP-OES are low cost and easy installation, but some semiconductor industries who adopted commercialized SP-OES product experiencing less sensitivity and slow sensor response. OH out-gas chemistry monitoring was performed to have a direct comparison of a conventional single type tube and a by-pass type tube, and fluid dynamic simulation on the improved hardware design was also followed. It is observed faster pumping out of OH from the chamber in the by-pass type SP-OES.

  • PDF

Gain improvement of double-pass two-stage EDFA by using band-rejection filter (필터에 의한 이중경로 2단 EDFA의 이득 향상)

  • 손익부;백장기;이남권;권형우;송재원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2003.02a
    • /
    • pp.142-143
    • /
    • 2003
  • EDFA의 이득(gain)과 잡음지수(noise figure)는 매우 중요한 특성 중의 하나이다. 전송 시스템에서 필연적으로 발생하는 ASE 잡음을 제거하는 것이 중요하다. EDFA의 중간에 필터(filter)와 아이솔레이터(isolator)를 삽입하여 불필요한 ASE를 제거함으로써 이득과 잡음지수를 향상시킬 수 있으며, 기존의 단일경로(single-pass) EDFA에서 필터의 위치가 40-60% 근처에서 이득과 잡음지수 향상이 가장 크게 된다. 그러나, 거울(mirror)을 사용하여 증폭 효율을 높인 이중경로(double-pass) EDFA에서 필터에 의한 이득 향상에 관한 연구발표는 아직까지 없다. (중략)

  • PDF

Laboratory and Meta Analysis for 9% NI Steel of Liquified Natural Gas Carrier (LNG 저장 탱크 운반선 9% Ni Steel의 용접성에 대한 실험분석과 메타분석 연구)

  • Park, Sang Heup;Ahn, Duck Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.12
    • /
    • pp.670-677
    • /
    • 2016
  • Laboratory and meta-analyses were done for 9% NI Steel for use in a liquefied natural gas carrier. The meta-analysis is based on a previous study. The laboratory analysis examines the effects of a single pass and multiple passes on the tensile strength through an impulse-response test. The tensile strength increased from pass one to pass three and decreased from pass four to pass ten. The pass and multi-pass welding had a positive effect on the tensile strength. Lastly, the welding and tensile time had a positive effect on the tensile strength.