Browse > Article
http://dx.doi.org/10.5762/KAIS.2016.17.12.670

Laboratory and Meta Analysis for 9% NI Steel of Liquified Natural Gas Carrier  

Park, Sang Heup (Department of Engineering, Kongju University)
Ahn, Duck Hyun (Department of Technology, Kogas-Tech)
Publication Information
Journal of the Korea Academia-Industrial cooperation Society / v.17, no.12, 2016 , pp. 670-677 More about this Journal
Abstract
Laboratory and meta-analyses were done for 9% NI Steel for use in a liquefied natural gas carrier. The meta-analysis is based on a previous study. The laboratory analysis examines the effects of a single pass and multiple passes on the tensile strength through an impulse-response test. The tensile strength increased from pass one to pass three and decreased from pass four to pass ten. The pass and multi-pass welding had a positive effect on the tensile strength. Lastly, the welding and tensile time had a positive effect on the tensile strength.
Keywords
Impulse-response test; Laboratory analysis; LNG carrier; Meta analysis; Multi pass welding; Tensile strength; 9% Ni Steel;
Citations & Related Records
연도 인용수 순위
  • Reference
1 D. J. Oh, J. M. Lee, B. J. Noh, W. S. Kim, Ryuichi - Ando, Toshiyuk I- Matsumoto, Myung - Hyun Kim, "Investigation of fatigue performance of low temperature alloys for liquefied natural gas storage tanks," Journal of Mechnical Engineering Science, pp. 1-15, 2015. DOI: http://dx.doi.org/10.1177/0954406215569255   DOI
2 Abd Khourshid, El Fattah Mustafa, Mohamed Ahemed Ghanem, "Using the welding parameters to improve the mechanical properties of Liquefied Natural Gas storage tank welded joint," IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE), vol. 4, no. 3, pp. 32-39, 2012.   DOI
3 Hiroshi Nishigami, Masaki Kusagawa, Maki Yamahita, Tomoya Kawabata, Tahahiro Kamo, Kazushi Onishi, Syuichi Hirai, Nakazu Sakato, Masahiko Mitsumoto, Yukito Hagihara, "Development and realization of large scale LNG storage tank applying 7% Nikel steel plate," 2015 World Gas Conference, pp. 1-18, 2012.
4 R. Kruzic, "LNG storage tanks: advancements in weld inspections," Hydrocarbon Processing July 2004, pp. 53-55, 2004.
5 Hyo Kim, Jae-Sun Koh, Youngsoo Kim, Theofanius G. Theofanous, "Risk Assesment of membrane type LNG storage tanks in Korea-based on fault treee analysis," Korean J. Chem. Eng, vol. 22, no. 1, pp. 1-8, 2005. DOI: https://doi.org/10.1007/BF02701454   DOI
6 Liane Smith, Bruce Craig, "Properties of metallic for LNG service," Paper 57-presented at 9th MECC, Bahrain, February 12-14th 2001, pp. 1-10, 2001.
7 Y. M. Yang, "Development of the world's largest above-ground full containment ling storage tank," 23rd World Gas Conference, Amsterdam 2006, pp. 1-14, 2006.
8 Pascale Grieve, "GST, a new generation of LNG membrane-type land storage tank," Working paper, pp. 1-17, 2012.