• 제목/요약/키워드: single-electrode sensor

검색결과 52건 처리시간 0.021초

압전재료를 이용한 SAW 온도센서의 제작 및 특성에 대한 연구 (A study on the Fabrication and Characteristics of SAW Temperature Sensor using piezoelectric material)

  • 박재홍;김재환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.563-567
    • /
    • 2004
  • In this paper, a remote temperature sensor based on surface acoustic wave is introduced and the issues on design, manufacturing, and test of the sensor are addressed. SAW sensors having single and double electrode are prepared on the 128$^{\circ}$ YX-LiNbO$_3$ Substrate. The frequency responses of SAW sensors on the temperature change are compared. To measure the change of center frequency, two center frequencies on the 3dB and 20dB are measured and compared. Since the center frequency on the temperature change from -30$^{\circ}C$ to 80$^{\circ}C$ is linearly changed, the SAW sensor is applicable to the temperature sensor.

  • PDF

Electrokinetic deposition of individual carbon nanotube onto an electrode gap

  • Han Chang-Soo;Seo Hee-Won;Lee Hyung-Woo;Kim Soo-Hyun;Kwak Yoon-Keun
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제7권1호
    • /
    • pp.42-46
    • /
    • 2006
  • This paper presents a method for deposition an individual carbon nanotube (CNT). The alignment of a single CNT is very useful to perform studies related to applications in FET (Field Emitted Transistor), SET (Single Electron Transistor) and to make chemical sensor as well as bio sensors. In this study, we developed the deposition method of a CNT individualized in a solution. Using the electrokinetic method, we found the optimum conditions to assemble the nanotube and discussed about plausible explanation for the assembling mechanism. These results will be available to use for making the CNT sensor device.

산소센서용 CTA/PCL 효소고정화막과 반투막을 단일화한 PVA적층막의 제조 및 특성 (Preparation and Characteristics of a Single-layer PVA Laminated CTA/PCL Membrane for Oxygen Biosensor Electrode)

  • 서종원;김태진;정용섭;윤정원
    • 센서학회지
    • /
    • 제8권3호
    • /
    • pp.247-252
    • /
    • 1999
  • 바이오센서로 이용되는 산소센서에는 효소고정화막과 함께 반투성막이 필요한데, 이러한 두 층의 막은 취급이 쉽지 않아서 상업화하기가 불리하므로, 이 두 막을 하나의 적층막으로 제조하였다. cellulose triacetate/polycarprolactone(CTA/PCL)막에 1,1'-carbonyl diimidazole(CDI) 방법으로 glucose oxidase, ascorbate oxidase, pyrubate oxidase와 alcohole oxidase 등의 효소를 고정화시킨 다음, 그 위에 polyvinylalcohol을 알데하이드와 산과 혼합하여 적층방법으로 단일막을 제조하였다. 고정화된 이 적층막을 산소전극에 부착하여 glucose, ascorbate, pyrubate, ethanol의 농도에 따른 전류변화를 측정한 결과, 각각 5-10mmol 이내의 기질농도에서 $0.38{\sim}0.83{\mu}A$까지 r=0.995의 선형성을 나타내었다. 한편, 고정화된 적층막의 저장중 안정성은 glucose oxidase는 8주 후에도 56% 이상의 활성을 나타내고 있었으나 나머지 효소들은 효소의 안정성이 낮았다.

  • PDF

DNA 염기서열 분석을 위한 전기 화학적 측정법 (Electrochemical measurement for analysis of DNA sequence)

  • 조성보;홍진섭;김영미;박정호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.92-97
    • /
    • 2002
  • One of the important roles of a DNA chip is the capability of detecting genetic diseases and mutations by analyzing DNA sequence. For a successful electrochemical genotyping, several aspects should be considered including the chemical treatment of electrode surface, DNA immobilization on electrode, hybridization, choice of an intercalator to be selectively bound to double standee DNA, and an equipment for detecting and analyzing the output signal. Au was used as the electrode material, 2-mercaptoethanol was used for linking DNA to Au electrode, and methylene blue was used as an indicator that can be bound to a double stranded DNA selectively. From the analysis of reductive current of this indicator that was bound to a double stranded DNA on an electrode, a normal double stranded DNA was able to be distinguished from a single stranded DNA in just a few seconds. Also, it was found that the peak reduction current of indicator is proportional to the concentration of target DNA to be hybridized with probe DNA. Therefore, it is possible to realize a sim71e and cheats DNA sensor using the electrochemical measurement for genotyping.

지문인식센서 품질평가를 위한 검사부 프로브의 소재 적합성과 구조 최적화 연구 (Materials Compatibility and Structure Optimization of Test Department Probe for Quality Test of Fingerprint Sensor)

  • 손은원;윤지원;김대업;임재원;김광석
    • 마이크로전자및패키징학회지
    • /
    • 제24권4호
    • /
    • pp.73-77
    • /
    • 2017
  • 최근 정보 보호가 이슈화됨에 따라 지문인식센서의 활용이 점차 증가하고 있으며, 센서 인식률 오차를 최소화 할 수 있는 품질평가를 요구한다. 지문인식센서 전극과 검사부 프로브 팁이 접촉 시 발생하는 저항 값의 변화에 의해 센서의 품질이 평가되며, 품질평가의 재현성을 확보하기 위해서는 센서 전극의 변형 유발을 최소화할 수 있는 프로브 소재의 적합성과 구조 최적화 연구가 필요하다. 프로브 팁의 적합성 평가를 위한 소재로 니켈(Ni), 스틸(SK4), 베릴륨동(Beryllium copper), 인청동(Phosphor bronze)을 비교하였으며, 프로브 팁 접촉 후 전극의 압흔 크기와 접촉저항을 고려할 때 베릴륨동이 프로브 소재로 적합하다. 검사부 프로브는 지문인식센서 전극의 물리적 손상 방지와 다수의 지문인식센서 동시 검사가 가능한 구조를 위해 일체형 프로브 방식으로 제작하였다. 검사부의 재현성은 특정 전류 값을 인가하여 지문인식센서의 전압 변화로 판단하였으며, 베릴륨동 프로브 소재와 일체형 구조를 통해 센서 전극에 프로브가 300회 접촉하는 동안 센서의 전압 변화는 ${\pm}0.003V$ 이내의 우수한 재현성을 확인하였다.

단층 탄소나노튜브의 암모니아 가스에 대한 감응특성과 열처리 효과 (NH3 Gas Sensing Characteristics of Single-Walled Carbon Nanotubes and Heating Effect)

  • 허증수;이상태;김민주;윤광현
    • 한국재료학회지
    • /
    • 제14권4호
    • /
    • pp.276-280
    • /
    • 2004
  • Carbon nanotubes(CNT) were synthesized by arc-discharge method. To fabricate CNT sensor, CNT powder was dispersed in $\alpha$-Terpinol($C_{10}$ $H_{17}$OH) solution. The CNT films were fabricated by screen printing on the interdigitated Pt/Pd alloy electrode. The microstructure of CNT film were observed by scanning electron microscopy (SEM). In order to investigate the gas sensing characteristics of the film, the CNT film was experimented to measure NH$_3$ response and recovery time. And this sensor shows better reproductibility and faster recovery time than another CNT sensors. We suggest the possibility to utilize a CNT as new sensing materials for environmental monitoring.

공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로 (CMI Tolerant Readout IC for Two-Electrode ECG Recording)

  • 강상균;남경식;고형호
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.

Characterization of O2 ionosorption induced potential changing property of SnO2 nanowire with Kelvin force microscopy (KFM)

  • Heo, Jinhee;Won, Soonho
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc2호
    • /
    • pp.359-362
    • /
    • 2012
  • We have employed Kelvin force microscopy (KFM) system to measure the potential change of a single SnO2 nanowire which had been synthesized on the Au thin film by a thermal process. By using the KFM probing technique, Rh coated conducting cantilever can approach a single SnO2 nanowire in nano scale and get the potential images with oscillating AC bias between Au electrode and cantilever. Also, during imaging the potential status, we controlled the concentration of oxygen in measuring chamber to change the ionosorption rate. From the results of such experiments, we verified that the surface potential as well as doping type of a single SnO2 nanowire could be changed by oxygen ionosorption.

Identification of Partial Discharge Defects based on Back- Propagation Algorithm in Eco-friendly Insulation Gas

  • Sung-Wook Kim
    • Journal of information and communication convergence engineering
    • /
    • 제21권3호
    • /
    • pp.233-238
    • /
    • 2023
  • This study presents a method for identifying partial discharge defects in an eco-friendly gas insulated system using a backpropagation algorithm. Four partial discharge (PD) electrode systems, namely, a free-moving particle, protrusion on the conductor, protrusion on the enclosure, and voids, were designed to simulate PD defects that can occur during the operation of eco-friendly gas-insulated switchgear. The PD signals were measured using an ultrahigh-frequency sensor as a nonconventional method based on IEC 62478. To identify the types of PD defects, the PD parameters of single PD pulses in the time and frequency domains and the phase-resolved partial discharge patterns were extracted, and a back-propagation algorithm in the artificial neural network was designed using a virtual instrument based on LabVIEW. The backpropagation algorithm proposed in this paper has an accuracy rate of over 90% for identifying the types of PD defects, and the result is expected to be used as a reference database for asset management and maintenance work for eco-friendly gas-insulated power equipment.

전기화학적 방법을 이용한 다중 효소 전극 제작 및 글루코스 검출 특성에 관한 연구 (A Study on the Detection Characteristics in Glucose and Fabrication of Bi-Enzyme Electrode using Electrochemical Method)

  • 한경호;신인성;윤도영
    • 전기화학회지
    • /
    • 제23권3호
    • /
    • pp.66-72
    • /
    • 2020
  • 본 연구에서는 글루코스 검출을 위한 HRP (horseradish peroxidase)와 GOD (glucose oxidase)를 혼합한 형태의 다중 효소 반응 바이오센서 개발연구를 수행하였다. 바이오센서는 제작 시간 단축을 위하여 전기전착법을 이용하여 제작하였으며, 경제적인 센서 제작을 위하여 SPE (screen printed electrode)를 사용하였다. 다중 효소 바이오센서의 효과를 확인하기 위하여 단일 효소 바이오센서를 제작하여 비교 및 분석하였다. 센서의 특성을 평가하기 위해서 주사전자현미경(scanning electron microscopy, SEM), 순환전위법(cyclic voltammetry, CV), 전기화학적 임피던스 분광법(electrochemical impedance spectroscopy, EIS), 시간대전류법(chronoamperometry, CA), 흐름 주입분석법(flow injection analysis, FIA)를 수행하였다. SEM, CV, EIS의 분석결과로부터 효소가 전극 표면에 고정화가 잘 된 것을 확인하였고, CA로부터 제작된 다중 효소 바이오센서가 단일 효소 바이오센서에 비해 신호성능이 200% 향상된 것을 확인하였다. 이로부터 HRP와 GOD가 서로 촉매적으로 반응한다는 것을 설명할 수 있었다. 또한, FIA의 결과에서 동일한 농도의 글루코스 용액을 4회 나누어 주입하였을 때, 전류신호량이 일정함을 확인하였고, 농도에 따른 전류신호량을 분석하여 신호민감성, 재현성, 안정성 등이 우수함을 설명할 수 있었다.