• Title/Summary/Keyword: single target

Search Result 1,417, Processing Time 0.027 seconds

Helicopter Pilot Metaphor for 3D Space Navigation and its implementation using a Joystick (3차원 공간 탐색을 위한 헬리콥터 조종사 메타포어와 그 구현)

  • Kim, Young-Kyoung;Jung, Moon-Ryul;Paik, Doowon;Kim, Dong-Hyun
    • Journal of the Korea Computer Graphics Society
    • /
    • v.3 no.1
    • /
    • pp.57-67
    • /
    • 1997
  • The navigation of virtual space comes down to the manipulation of the virtual camera. The movement of the virtual cameras has 6 degrees of freedom. However, input devices such as mouses and joysticks are 2D. So, the movement of the camera that corresponds to the input device is 2D movement at the given moment. Therefore, the 3D movement of the camera can be implemented by means of the combination of 2D and 1D movements of the camera. Many of the virtual space navigation browser use several navigation modes to solve this problem. But, the criteria for distinguishing different modes are not clear, somed of the manipulations in each mode are repeated in other modes, and the kinesthetic correspondence of the input devices is often confusing. Hence the user has difficulty in making correct decisions when navigating the virtual space. To solve this problem, we use a single navigation metaphore in which different modes are organically integrated. In this paper we propose a helicopter pilot metaphor. Using the helicopter pilot metaphore means that the user navigates the virtual space like a pilot of a helicopter flying in space. In this paper, we distinguished six 2D movement spaces of the helicopter: (1) the movement on the horizontal plane, (2) the movement on the vertical plane,k (3) the pitch and yaw rotations about the current position, (4) the roll and pitch rotations about the current position, (5) the horizontal and vertical turning, and (6) the rotation about the target object. The six 3D movement spaces are visualized and displayed as a sequence of auxiliary windows. The user can select the desired movement space simply by jumping from one window to another. The user can select the desired movement by looking at the displaced 2D movement spaces. The movement of the camera in each movement space is controlled by the usual movements of the joystick.

  • PDF

The Analysis of Predictive Factors for the Identification of Patients Who Could Benefit from Respiratory-Gated Radiotherapy in Non-Small Cell Lung Cancer (비소세포성 폐암에서 호흡동기방사선치료 적용 환자군의 선택을 위한 예측인자들의 분석)

  • Jang, Seong-Soon;Park, Ji-Chan
    • Radiation Oncology Journal
    • /
    • v.27 no.4
    • /
    • pp.228-239
    • /
    • 2009
  • Purpose: 4DCT scans performed for radiotherapy were retrospectively analyzed to assess the possible benefits of respiratory gating in non-small cell lung cancer (NSCLC) and established the predictive factors for identifying patients who could benefit from this approach. Materials and Methods: Three treatment planning was performed for 15 patients with stage I~III NSCLC using different planning target volumes (PTVs) as follows: 1) PTVroutine, derived from the addition of conventional uniform margins to gross tumor volume (GTV) of a single bin, 2) PTVall phases (patient-specific PTV), derived from the composite GTV of all 6 bins of the 4DCT, and 3) PTVgating, derived from the composite GTV of 3 consecutive bins at end-exhalation. Results: The reductions in PTV were 43.2% and 9.5%, respectively, for the PTVall phases vs. PTVroutine and PTVgating vs. PTVall phases. Compared to PTVroutine, the use of PTVall phases and PTVgating reduced the mean lung dose (MLD) by 18.1% and 21.6%, and $V_{20}$ by 18.2% and 22.0%, respectively. Significant correlations were seen between certain predictive factors selected from the tumor mobility and volume analysis, such as the 3D mobility vector, the reduction in 3D mobility and PTV with gating, and the ratio of GTV overlap between 2 extreme bins and additional reductions in both MLD and $V_{20}$ with gating. Conclusion: The additional benefits with gating compared to the use of patient-specific PTV were modest; however, there were distinct correlations and differences according to the predictive factors. Therefore, these predictive factors might be useful for identifying patients who could benefit from respiratory-gated radiotherapy.

Outcome of LINAC Radiosurgery for a Cavernous Angioma (해면상혈관종에 대한 선형가속기를 이용한 고선량 정위 방사선수술의 임상경험)

  • Hong Semie;Chie Eui Kyu;Park Suk Won;Kim Il Han;Ha Sung Hwan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.21 no.2
    • /
    • pp.107-111
    • /
    • 2003
  • Purpose: To establish the role of stereoactic radiosurgery using a linear accelerator for the treatment of patients with cavernous angloma. Materials and Methods: Between February 1995 and May 1997, 11 patients with cavernous angioma were treated with stereotactic radiosurgery using a linear accelerator. Diagnoses were based on the magnetic resonance imaging in 8 patients, and the histological in 3. The vascular lesions were located on the brainstem (5 cases), cerebellum (2 cases) thalamus (1 case) and cerebrum (3 cases). The clinical presentation at onset included previous intracerebral hemorrhages (9 cases) and seizures (2 cases). All patients were treated with a a linac-based radiosurgery. The median dose of radiation delivered was 16 Gy ranging from 14 to 24 Gy, which was typically proscribed to the 80$\%$ isodose surface (range 50 $\~$ 80$\%$), corresponding to the periphery of the lesion with a single isocenter. Ten patients were followed-up. Results: The median follow-up was 49 months ranging from 8 to 73 months, during which time two patients developed an intracerebral hemorrhage, 1 at 8 months, with the other at 64 months post radiosurgery. One patient developed neurological deficit after radiosurgery, and two developed an edema on the T2 weighted images of the MRI surrounding the radiosurgical target. Conclusion: The use of stereotactic radiosurgery in the treatment of a cavernous angioma may be effective in the prevention of rebleedlng, and can be safely delivered. However, a longer follow-up period will be required.

Effect of Ethane 1,2-Dimethane Sulfonate(EDS) on the Expression of Steroid Hormone Receptors, $5{\alpha}$-reductase and Aromatase in the Rat Epididymis (흰쥐 부정소 내의 스테로이드 호르몬 수용체, $5{\alpha}$-reductase 그리고 Aromatase 발현에 미치는 EDS의 영향)

  • Son, Hyeok-Joon;Lee, Sung-Ho
    • Development and Reproduction
    • /
    • v.11 no.3
    • /
    • pp.187-193
    • /
    • 2007
  • Ethane 1,2-dimethane sulfonate(EDS), a Leydig cell specific toxicant, has been widely used to create the reversible testosterone withdrawal rat model. Though the maintenance of epididymal structure and function is highly dependent on the testosterone secreted from testis, its derivatives, dihydroxytestosterone(DHT) and estrogen, might have crucial roles. The aim of present study was to monitor the expression patterns of sex steroid receptors, cytochrome P450 aromatase(P450arom) and $5{\alpha}$-reductase in the rat epididymis up to 7 weeks after EDS injection. Adult male rats($350{\sim}400g$) were injected with a single does of EDS(75 mg/kg i.p.) and sacrificed on weeks 0, 1, 2, 3, 4, 5, 6 and 7. The transcriptional activities of the target genes were evaluated by semi-quantitative RT-PCRs. The transcript level of estrogen receptor alpha($ER{\alpha}$) in EDS group was significantly higher than control level on week 1(P<0.01). After week 2, there was no significant difference in $ER{\alpha}$ levels between EDS group and control. The transcript level of estrogen receptor beta($ER{\beta}$) in EDS group was significantly higher than control level on week 1(P<0.05), lowered on weeks 2 and 3(P<0.05 and P<0.01, respectively), fluctuated during weeks 4 and 6, and elevated on week 7(P<0.05). The androgen receptor (AR) message levels increased significantly week 2(P<0.01), then returned to control level on week 3. In contrast, expression of cytochrome P450 aromatase(P450arom) decreased sharply during weeks $1{\sim}3$(P<0.01 on weeks 1 and 2; P<0.05 on week 3), then went back to control level on week 4. The mRNA level of $5{\alpha}$-reductase type 2($5{\alpha}$-RT2) increased significantly on week 4(P<0.01), then returned to control level. The present study indicated that EDS administration could induce reversible alterations in the transcriptional activities of sex steroid hormone receptors and androgenconverting enzymes in rat epididymis. EDS injection model will be useful to clarify the regulation mechanism of mammalian epididymal physiology.

  • PDF

Suggestion for Technology Development and Commercialization Strategy of CO2 Capture and Storage in Korea (한국 이산화탄소 포집 및 저장 기술개발 및 상용화 추진 전략 제안)

  • Kwon, Yi Kyun;Shinn, Young Jae
    • Economic and Environmental Geology
    • /
    • v.51 no.4
    • /
    • pp.381-392
    • /
    • 2018
  • This study examines strategies and implementation plans for commercializing $CO_2$ capture and storage, which is an effective method to achieve the national goal of reducing greenhouse gas. In order to secure cost-efficient business model of $CO_2$ capture and storage, we propose four key strategies, including 1) urgent need to select a large-scale storage site and to estimate realistic storage capacity, 2) minimization of source-to-sink distance, 3) cost-effectiveness through technology innovation, and 4) policy implementation to secure public interest and to encourage private sector participation. Based on these strategies, the implementation plans must be designed for enabling $CO_2$ capture and storage to be commercialized until 2030. It is desirable to make those plans in which large-scale demonstration and subsequent commercial projects share a single storage site. In addition, the plans must be able to deliver step-wised targets and assessment processes to decide if the project will move to the next stage or not. The main target of stage 1 (2019 ~ 2021) is that the large-scale storage site will be selected and post-combustion capture technology will be upgraded and commercialized. The site selection, which is prerequisite to forward to the next stage, will be made through exploratory drilling and investigation for candidate sites. The commercial-scale applicability of the capture technology must be ensured at this stage. Stage 2 (2022 ~ 2025) aims design and construction of facility and infrastructure for successful large-scale demonstration (million tons of $CO_2$ per year), i.e., large-scale $CO_2$ capture, transportation, and storage. Based on the achievement of the demonstration project and the maturity of carbon market at the end of stage 2, it is necessary to decide whether to enter commercialization of $CO_2$ capture and storage. If the commercialization project is decided, it will be possible to capture and storage 4 million tons of $CO_2$ per year by the private sector in stage 3 (2026 ~ 2030). The existing facility, infrastructure, and capture plant will be upgraded and supplemented, which allows the commercialization project to be cost-effective.

Usefulness and Comparison of $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA Single Photon Emission Computed Tomography in Distinguishing Lung Cancer from Benign Lesion (폐암과 양성질환의 감별에 $^{201}TI$-chloride, $^{99}mTc$-MIBI, $^{99}mTc(V)$-DMSA 단일광자전산화단층촬영술의 비교 및 가치)

  • Kim, Chang Ho;Chae, Sang Cheol;Park, Jae Yong;Jung, Tae Hoon;Ahn, Byeong Cheol;Lee, Jae Tae
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.5
    • /
    • pp.720-727
    • /
    • 1996
  • Objectives: $^{201}TI$ - chloride, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA SPECT has been used in distinguishing lung cancer from benign lesion. To compare the diagnostic efficacy of SPECT with these tumor - seeking agents, we perfonned three consecutive SPECT using $^{201}TI$, $^{99m}Tc$ - MIBI, $^{99m}Tc$(V) - DMSA in same subjects with a solitary pulmonary lesion. Methods: SPECT was carried out at 10min and 3hr for $^{201}TI$ after injection of 20mCi, and 2hr for $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA after injection of 20mCi, respectively, in 37 patients with a solitary pulmonary lesion(27 lung cancer and 10 benign diseases). In patients showing visual uptake on lesion site, we obtained the lesion - to - background(target lesion/contralateral normal lung) uptake ratio from transverse slice for each radionuclide and also calculated the retention index for $^{201}TI$. Results: The diagnostic sensitivity of $^{201}TI$, $^{99m}Tc$ - MIBI and $^{99m}Tc$(V) - DMSA SPECT to lung cancer was 100%, 96% and 73%, and the specificity was 40%, 70% and 70%, respectively. The low specificities for these agents were mainly due to high positive uptake in patients with active pulmonary tuberculosis. There were no significant differences in uptake ratios and retention index between malignant and benign lesions, and among the histologic types of lung cancer. Conclusion : $^{201}TI$ and $^{99m}Tc$ - MIBI showed higher sensitivity than $^{99m}Tc$(V) - DMSA for detecting lung cancer, but was of limited usefulness in distinguishing lung cancer from benign lesion due to low specificity, especially in area with a high prevalence of active pulmonary tuberculosis.

  • PDF

Petrochemistry of the Pink Hornblende Biotite Granite in the Galmal-Yeongbug Area of the North Gyeonggi (경기북부 갈말-영북일대 백악기 홍색 각섬석흑운모화강암의 암석화학)

  • Yun, Hyun-Soo;Hong, Sei-Sun;Kim, Jeong-Min
    • The Journal of the Petrological Society of Korea
    • /
    • v.15 no.4 s.46
    • /
    • pp.167-179
    • /
    • 2006
  • Division of granites in the Galmal-Yeonbug area, northern Gyeonggi, can be grey hornblende biotite granite (JHBG), biotite granite (JBG) and pink hornblende biotite granite (CHBG) by lithofacies. JHBG of small stock occurs as medium-grained with grey color and minute sphene. JBG occurs as medium-grained and light grey to grey in the north-east part of the area. The main study target CHBG covers in the north-southeast part of the area, and occurs medium-to coarse-grained with pink color. CHBG shows partly minute miaroles, and pegmatitic pocket with druse texture. From the mineral age data (K-Ar method). JHBG and JBG and CHBG are the igneous activity products of Daebo orogeny with different Jurassic and Bulgugsa disturbance of Cretaceous, respectively. And the age data also agree with geologic occurrences and interpretations of the granites in the field. CHBG consists of quartz, plagioclase, alkali-feldspar, biotite, hornblende, allanite, apatite, zircon, some calcite and opaques. Among them, alkalifeldspar and calcite occur characteristically in mostly perthitic othoclase and secondary filling of minutely miarolitic cavity, respectively. In modal analysis and QAP diagram, CHBG plots in granite field, and especially boundary of monzo-and syeno-granite fields. From the major oxide variations, molar A/CNK, $SiO_{2}\;vs\;K_{2}O$, AMF and so on, CHBG belongs to the acidic, peraluminous and high-K calc-alkaline, and was late differentiation product of single granitic magma. Barium and strontium have also dominantly differentiation trend, and in CaO vs Sr and $K_{2}O$ vs Sr, Sr was more participitated in the fractionation of plagioclase than that of alkali-feldspar. Normalized REE concentrations to chondrite value have parallel and gradual LREE enrichment and HREE depletion patterns, and weak Eu negative anomalies and narrow ranges of normalized Eu can suggest that plagioclase fractionations occurred mildly in the whole CHBG.

The Changes of Dietary Reference Intakes for Koreans and Its Application to the New Text Book (한국인 영양섭취기준에 대한 이해 및 새 교과서에의 적용 방안)

  • Kim, Jung-Hyun;Lee, Min-June
    • Journal of Korean Home Economics Education Association
    • /
    • v.20 no.2
    • /
    • pp.75-94
    • /
    • 2008
  • The purposes of this paper are to describe the newly established reference values of nutrient intakes: to apply the changed dietary reference intakes to the new text book based on the revised curriculum: and to contrive substantial contents in the domain of dietary life(foods & nutrition) of new text book. Dietary Reference Intakes for Koreans(KDRIs) is newly established reference values of nutrient intakes that are considered necessary to maintain the health of Koreans at the optimal state and to prevent chronic diseases and overnutrition. Unlike previously used Recommended Dietary Allowances for Koreas(KRDA), which presented a single reference value for intake of each nutrient, multiple values are set at levels for nutrients to reduce risk of chronic diseases and toxicity as well as prevention of nutrient deficiency. The new KDRIs include the Estimated Average Requirement(EAR), Recommended Intake(RI), Adequate Intake(AI), and Tolerable Upper Intake Level(UL). The EAR is the daily nutrient intake estimated to meet the requirement of the half of the apparently healthy individuals in a target group and thus is set at the median of the distribution of requirements. The RI is set at two standard deviations above the EAR. The AI is established for nutrients for which existing body of knowledge are inadequate to establish the EAR and RI. The UL is the highest level of daily nutrient intake which is not likely to cause adverse effects for the human health. Age and gender subgroups are established in consideration of physiological characteristics and developmental stages: infancy, toddler, childhood, adolescence, adulthood and old age. Pregnancy and lactation periods were considered separately and gender is divided after early childhood. Reference heights and weights are from the Korean Agency for Technology and Standards, Ministry of Commerce, Industry and Energy. The practical application of DRIs to the new books based on the revision in the 7th curriculum is to assess the dietary and nutrient intake as well as to plan a meal. It can be utilized to set an appropriate nutrient goal for the diet as usually eaten and to develop a plan that the individual will consume using a nutrient based food guidance system in the new books based on the revision in the 7th curriculum.

  • PDF

Dosimetric Verifications of the Output Factors in the Small Field Less Than $3cm^2$ Using the Gafchromic EBT2 Films and the Various Detectors (Gafchromic EBT2필름과 다양한 검출기를 이용하여 $3cm^2$ 이하의 소조사면에서 출력비율의 선량검증)

  • Oh, Se An;Yea, Ji Woon;Lee, Rena;Park, Heon Bo;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.218-224
    • /
    • 2014
  • The small field dosimetry is very important in modern radiotherapy because it has been frequently used to treat the tumor with high dose hypo-fractionated radiotherapy or high dose single fraction stereotactic radiosurgery (SRS) with small size target. But, the dosimetry of a small field (< $3{\times}3cm^2$) has been great challenges in radiotherapy. Small field dosimetry is difficult because of (a) a lack of lateral electronic equilibrium, (b) steep dose gradients, and (c) partial blocking of the source. The objectives of this study were to measure and verify with the various detectors the output factors in a small field (<3 cm) for the 6 MV photon beams. Output factors were measured using the CC13, CC01, EDGE detector, thermoluminescence dosimeters (TLDs), and Gafchromic EBT2 films at the sizes of field such as $0.5{\times}0.5$, $1{\times}1$, $2{\times}2$, $3{\times}3$, $5{\times}5$, and $10{\times}10cm^2$. The differences in the output factors with the various detectors increased with decreasing field size. Our study demonstrates that the dosimetry for a small photon beam (< $3{\times}3cm^2$) should use CC01 or EDGE detectors with a small active volume. And also, Output factors with the EDGE detectors in a small field (< $3{\times}3cm^2$) coincided well with the Gafchromic EBT2 films.

2-D/3-D Seismic Data Acquisition and Quality Control for Gas Hydrate Exploration in the Ulleung Basin (울릉분지 가스하이드레이트 2/3차원 탄성파 탐사자료 취득 및 품질관리)

  • Koo, Nam-Hyung;Kim, Won-Sik;Kim, Byoung-Yeop;Cheong, Snons;Kim, Young-Jun;Yoo, Dong-Geun;Lee, Ho-Young;Park, Keun-Pil
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.2
    • /
    • pp.127-136
    • /
    • 2008
  • To identify the potential area of gas hydrate in the Ulleung Basin, 2-D and 3-D seismic surveys using R/V Tamhae II were conducted in 2005 and 2006. Seismic survey equipment consisted of navigation system, recording system, streamer cable and air-gun source. For reliable velocity analysis in a deep sea area where water depths are mostly greater than 1,000 m and the target depth is up to about 500 msec interval below the seafloor, 3-km-long streamer and 1,035 $in^3$ tuned air-gun array were used. During the survey, a suite of quality control operations including source signature analysis, 2-D brute stack, RMS noise analysis and FK analysis were performed. The source signature was calculated to verify its conformity to quality specification and the gun dropout test was carried out to examine signature changes due to a single air gun's failure. From the online quality analysis, we could conclude that the overall data quality was very good even though some seismic data were affected by swell noise, parity error, spike noise and current rip noise. Especially, by checking the result of data quality enhancement using FK filtering and missing trace restoration technique for the 3-D seismic data inevitably contaminated with current rip noises, the acquired data were accepted and the field survey could be conducted continuously. Even in survey areas where the acquired data would be unsuitable for quality specification, the marine seismic survey efficiency could be improved by showing the possibility of noise suppression through onboard data processing.