Experimental Study of SBLOCA Simulation of Safety-Injection Line Break with Single Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 안전주입배관 파단 소형냉각재상실사고 모의에 대한 실험적 연구)

  • Ryu, Sung Uk;Bae, Hwang;Ryu, Hyo Bong;Byun, Sun Joon;Kim, Woo Shik;Shin, Yong-Cheol;Yi, Sung-Jae;Park, Hyun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.3
    • /
    • pp.165-172
    • /
    • 2016
  • An experimental study of the thermal-hydraulic characteristics of passive safety systems (PSSs) was conducted using a system-integrated modular advanced reactor-integral test loop (SMART-ITL). The present passive safety injection system for the SMART-ITL consists of one train with the core makeup tank (CMT), the safety injection tank, and the automatic depressurization system. The objective of this study is to investigate the injection effect of the PSS on the small-break loss-of-coolant accident (SBLOCA) scenario for a 0.4 inch line break in the safety-injection system (SIS). The steady-state condition was maintained for 746 seconds before the break. When the major parameters of the target value and test results were compared, most of the thermal-hydraulic parameters agreed closely with each other. The water level of the reactor pressure vessel (RPV) was maintained higher than that of the fuel assembly plate during the transient, for the present CMT and safety injection tank (SIT) flow rate conditions. It can be seen that the capability of an emergency core cooling system is sufficient during the transient with SMART passive SISs.

Run-time Memory Optimization Algorithm for the DDMB Architecture (DDMB 구조에서의 런타임 메모리 최적화 알고리즘)

  • Cho, Jeong-Hun;Paek, Yun-Heung;Kwon, Soo-Hyun
    • The KIPS Transactions:PartA
    • /
    • v.13A no.5 s.102
    • /
    • pp.413-420
    • /
    • 2006
  • Most vendors of digital signal processors (DSPs) support a Harvard architecture, which has two or more memory buses, one for program and one or more for data and allow the processor to access multiple words of data from memory in a single instruction cycle. We already addressed how to efficiently assign data to multi-memory banks in our previous work. This paper reports on our recent attempt to optimize run-time memory. The run-time environment for dual data memory banks (DBMBs) requires two run-time stacks to control activation records located in two memory banks corresponding to calling procedures. However, activation records of two memory banks for a procedure are able to have different size. As a consequence, dual run-time stacks can be unbalanced whenever a procedure is called. This unbalance between two memory banks causes that usage of one memory bank can exceed the extent of on-chip memory area although there is free area in the other memory bank. We attempt balancing dual run-time slacks to enhance efficiently utilization of on-chip memory in this paper. The experimental results have revealed that although our algorithm is relatively quite simple, it still can utilize run-time memories efficiently; thus enabling our compiler to run extremely fast, yet minimizing the usage of un-time memory in the target code.

The Effect of the Addition of BZO Nanopowder in the YBCO PLD Targets on the Flux Pinning Properties of BZO-YBCO Thin Film (YBCO PLD 타겟에 BZO 나노분말 첨가에 따른 PLD-YBCO 박막의 자속고정 효과)

  • Song, K.J.;Ko, R.K.;Lee, Y.S.;Park, Y.M.;Yang, J.S.;Kim, H.S.;Ha, H.S.;Ha, D.W.;Kim, S.W.;Oh, S.S.;Kim, D.J.;Park, C.;Yoo, S.I.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.20-21
    • /
    • 2005
  • [ $BaZrO_3$ ], nanopowder was added to YBCO powder to make ($BazrO_3)_x(YBCO)_{(100-x)mol.-%}$ ($BZO_x$-YBCO) ($0{\leq}x{\leq}10$) composite targets fur pulsed laser deposition of superconducting layer in order to investigate the effect of the addition of BZO nanopowder in the YBCO target on the flux pinning properties of $BZO_x$-YBCO thin films. All the $BZO_x$-YBCO thin films were grown on single crystal STO substrate under similar conditions in the PLD chamber. The effect of YBCO targets doped with BZO on the flux pinning properties of $BZO_x$-YBCO thin films has been investigated comparatively. The isothermal magnetizations M(H) of the films were measured at temperatures between 5 and 80 K in fields up to 5 T, employing a PPMS. The optimal amount of BZO nanopowders in $BZO_x$-YBCO thin films to obtain the strongest flux pinning effects at high magnetic fields is about 6 mol.-%.

  • PDF

Multiplex PCR Using Conserved and Species-Specific 16S rDNA Primers for Simultaneous Detection of Fusobacterium nucleatum and Actinobacillus actinomycetemcomitans

  • Kim, Mi-Kwang;Kim, Hwa-Sook;Kim, Byung-Ock;Yoo, So-Young;Seong, Jin-Hyo;Kim, Dong-Kie;Lee, Shee-Eun;Choe, Son-Jin;Park, Joo-Cheol;Min, Byung-Moo;Jeong, Moon-Jin;Kim, Do-Kyung;Shin, Yong-Kook;Kook, Joong-Ki
    • Journal of Microbiology and Biotechnology
    • /
    • v.14 no.1
    • /
    • pp.110-115
    • /
    • 2004
  • This study was undertaken to develop PCR primers for the simultaneous detection of Fusobacterium nucleatum and Actinobacillus actinomycetemcomitans, using two species-specific reverse primers in combination with a single conserved forward primer. These primers target the variable and conserved regions of the 16S rDNA. The primer specificity was tested against (i) four F. nucleatum and three A. actinomycetemcomitans strains and (ii) seven representatives of the different species of oral bacteria. The primer sensitivity was determined by testing serial dilutions of the purified genomic DNA of F. nucleatum and A. actinomycetemcomitans. The data indicate that species-specific amplicons could be obtained for all the F. nucleatum and A. actinomycetemcomitans strains tested, which were not found in the seven other species. The multiplex PCR could detect as little as 4 fg of chromosomal DNA of F. nucleatum and A. actinomycetemcomitans simultaneously. These findings suggest that these PCR primers are highly sensitive and are suitable for applications in epidemiological studies, diagnosis, and monitoring F. nucleatum and A. actinomycetemcomitans after the treatment of periodontitis.

Enhancement of insecticidal efficacy of acetamiprid soluble concentrates using different adjuvants (서로 다른 보조제에 의한 acetamiprid 액제의 살충활성 증진효과)

  • Kim, Hyeong-Min;Lee, Weon-Kee;Kim, Jong-Kwan;Lee, Chang-Hyuk;Yu, Yong-Man;Hwang, In-Cheon
    • The Korean Journal of Pesticide Science
    • /
    • v.8 no.4
    • /
    • pp.325-331
    • /
    • 2004
  • The studies were undertaken to establish optimum formulation recipes of acetamipid 4% SL(soluble concentrate) using different adjuvants and to evaluate enhanced control effect on target insect pests by adjuvants. Adjuvants for the studies used were SS(Sodium alkylcarboxylate) and PE(Polyoxyethylene alkyl ether). After the fundamental recipe for SL being established by using co-solvent for stability at low temperature, four types of SL were formulated. The physical properties and insecticidal efficacies of the tested SL formulations were investigated. Surface tension of SL1 without adjuvant was highly decreased from 44 dyne/cm to 34 dyne/cm by addition of adjuvants. SL4 using mixed adjuvant showed the lowest contact angle. Efficacies of SL1 without adjuvant against the palm thrips (Thrips palmi) and the cotton aphid (Aphis gossypii) on cucumber were increased by adding adjuvants. SL4 using mixed adjuvant showed higher efficacy than SL2 and SL3 using single adjuvant. These results have demonstrated that the selected adjuvants could be used to enhance insecticide efficacy and reduce spray dose of insecticide.

A Multicenter Noncomparative Clinical Study on Midface Rejuvenation Using a Nonabsorbable Polypropylene Mesh: Evaluation of Efficacy and Safety

  • Pak, Chang Sik;Chang, Lan Sook;Lee, Hobin;Jeong, Jae Hoon;Jeong, Jinwook;Yoon, Eul-Sik;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • v.42 no.5
    • /
    • pp.572-579
    • /
    • 2015
  • Background Facial rejuvenation can be achieved using a variety of techniques. Since minimally invasive procedures for face lifting have become popular because of their convenience and short operating time, numerous minimally invasive surgical procedures have been developed. In this study, a nonabsorbable polypropylene mesh is introduced as a new face lifting instrument, with the nasolabial fold as the main target area. In this paper, we report the efficacy and safety of a polypropylene mesh in midface rejuvenation. Methods Thirty-three subjects with moderate-to-severe nasolabial folds were enrolled from two medical institutions for a noncomparative single-sample study. A mesh was inserted above the superficial muscular aponeurotic system layer, reaching the nasolabial folds through a temporal scalp incision. After 3 weeks, the temporal end of the mesh was pulled to provide a lifting effect. Then, the mesh was fixed to the deep temporal fascia using nonabsorbable sutures. To evaluate efficacy, we compared the scores on the Wrinkle Severity Rating Scale and a visual analog scale for patient satisfaction between the baseline and 7 weeks postoperatively. In addition, we evaluated safety based on the incidence of adverse events. Results The treatment was deemed effective at improving wrinkles in 23 of 28 cases, and patient satisfaction improved significantly during the study period. There were seven cases of skin or subcutaneous tissue complications, including edema and erythema, but there were no suspected serious adverse events. Conclusions Face lifting using a nonabsorbable mesh can improve nasolabial folds without serious adverse effects. Thus, this technique is safe and effective for midface rejuvenation.

Fine Structure on the Epidermis of the Scalp of the Head-Irradiated Rats (방사선 조사를 받은 흰쥐 머리피부 표피층의 미세구조)

  • Ko, Jeong-Sik;Kim, Jae-Ho;Yang, Nam-Gil;Ahn, E-Tay;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.24 no.2
    • /
    • pp.63-77
    • /
    • 1994
  • This experiment was performed to study the morphological responses of the epidermis of the rat scalp, following X-ray irradiation. Male rats were divided into normal and experimental groups. Rats anesthetized with sodium thiopental, were exposed only on their head areas with a single dose of 3,000rads or 6,000rads, respectively. Radiation was produced by Mitsubishi Linea Accelerator ML-4MV at the speed of 200rads/min. The target distance was 80cm. Animals were sacrificed on six hours, two days and six days following irradiation. By the perfusion fixation through the heart, rats were fixed with 1% glutaraldehyde-1% paraformaldehyde solution. Pieces of the tissue taken from the scalp were refixed in 2.5% glutaraldehyde-1.5% paraformaldehyde solution, followed by post-fixation with 1% osmium tetroxide, and embedded within araldite mixture. The sections were cut on a LKB-V ultratome, stained with uranyl acetate and lead citrate, and were observed with JEM 100CX-II electron microscope. The results were as follow; 1. Six hours after exposure to 3,000rads of X-ray. Disrupted intercellular spaces, within which some amorphous materials were filled, disrupted mitochondria, and vacuoles in the keratinocytes were frequently observed, but six days after exposure to 3,000rads of X-ray, Morphology of the keratinocytes was generally restored. 2. Many of the morphological changes were seen on the six days after exposure to 6,000rads of X-ray. 3. Widened intercellular spaces and thickened dense plaques of the desmosomes were frequently observed after exposure to 6,000rads of X-ray. 4. In the experimental groups, the Langerhans and the Merkel cells were damaged, similarly to the keratinocyte. Above results suggest that head irradiation with the dose of 3,000rads temporarily damaged the epidermis of the scalp, though most of the structures recover within six days, whereas with the dose of 6,000rads it severely damaged the epidermis without showing any recovering tendency.

  • PDF

A Parametric Study on Intermediate Diaphragms of Steel-Box-Girder Bridges (강박스 거더교의 내부 다이아프램에 관한 매개변수 연구)

  • Park, Nam Hoi;Lim, Da Soo;Cho, Sun Kyu;Kang, Young Jong
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.3
    • /
    • pp.231-239
    • /
    • 2003
  • Many box girder bridges have been constructed during the past several decades due to their large bending and torsional rigidities as well as aesthetic considerations. However, box girders have shortcoming in that the cross section distorts under an eccentric loading and warps out of the section plane. Therefore, in order to reduce distortional stresses such as distortional warping and transverse bending normal stresses, diaphragms were generally installed in the box girders. Shapes of the diaphragms in steel-box-girder bridges constructed up to date were solid-plate, frame, and truss types. The objectives of this study using parametric study were to evaluate the appropriate stiffness ratio of intermediate diaphragms and then to propose the effective spacing and numbers of intermediate diaphragms based on the evaluated stiffness ratio. Target bridges for this study were straight continuous span bridges with a single-cell steel box section. The parameters for the parametric study were the shape of box section, the span numbers, the equivalent span length, the stiffness of intermediate diaphragms, and the spacing of intermediate diaphragms. From the results of the parametric study, the effective spacing and numbers as well as the stiffness ratio of the intermediate diaphragms will be presented.

Rapid Optimization of Multiple Isocenters Using Computer Search for Linear Accelerator-based Stereotactic Radiosurgery (Multiple isocenter를 이용한 뇌정위적 방사선 수술시 컴퓨터 자동 추적 방법에 의한 고속의 선량 최적화)

  • Suh Tae-suk;Park Charn Il;Ha Sung Whan;Yoon Sei Chul;Kim Moon Chan;Bahk Yong Whee;Shinn Kyung Sub
    • Radiation Oncology Journal
    • /
    • v.12 no.1
    • /
    • pp.109-115
    • /
    • 1994
  • The purpose of this paper is to develop an efficient method for the quick determination of multiple isocenters plans to provide optimal dose distribution in sterotactic radiosurgery. A Spherical dose model was developed through the use of fit to the exact dose data calculated in a 18cm diameter of spherical head phantom. It computes dose quickly for each spherical part and is useful to estimate dose distribution for multiple isocenters. An automatic computer search algorithm was developed using the relationship between the isocenter move and the change of dose shape, and adapted with a spherical dose model to determine isocenter separation and cellimator sizes quickly and automatically. A spheric81 dose model shows a comparable isodose distribution with exact dose data and permits rapid calculations of 3-D isodoses. the computer search can provide reasonable isocenter settings more quickly than trial and error types of plans, while producing steep dose gradient around target boundary. A spherical dose model can be used for the quick determination of the multiple isocenter plans with 3 computer automatic search. Our guideline is useful to determine the initial multiple isocenter plans.

  • PDF

Anti-Reflection Coating Application of SixOy-SixNy Stacked-Layer Fabricated by Reactive Sputtering (반응성 스퍼터링으로 제작된 SixOy-SixNy 적층구조의 반사방지 코팅 응용)

  • Gim, Tzang-Jo;Lee, Boong-Joo;Shina, Paik-Kyun
    • Journal of the Korean Vacuum Society
    • /
    • v.19 no.5
    • /
    • pp.341-346
    • /
    • 2010
  • In this paper, anti-reflection coating was investigated for decreasing the reflection in visible range of 400~650 [nm] through four staked layers of $Si_xO_y$ and $Si_xN_y$ thin films prepared by reactive sputtering method. Si single crystal of 6 [inch] diameter was used as a sputtering target. Ar and $O_2$ gases were used as sputtering gases for reactive sputtering for the $Si_xO_y$ thin film, and Ar and $N_2$ gases were used for reactive sputtering for the $Si_xN_y$ thin film. DC pulse power of 1900 [W] was used for the reactive sputtering. Refractive index and deposition rate were 1.50 and 2.3 [nm/sec] for the $Si_xO_y$, and 1.94 and 1.8 [nm/sec] for the $Si_xN_y$ thin film, respectively. Considering the simulation of the four layer anti-reflection coating structure with the above mentioned films, the $Si_xO_y-Si_xN_y$ stacked four-layer structure was prepared. The reflection measurement result for that structure showed that a "W" shaped anti-reflection was obtained successfully with a reflection of 1.7 [%] at 550 [nm] region and a reflection of 1 [%] at 400~650 [nm] range.