• Title/Summary/Keyword: single point measurement

Search Result 201, Processing Time 0.027 seconds

The Effects of the Four Point Probe Measurement Technique on the Precision and Accuracy in Electrical Resistivity Measurements. (4탐침 측정기술이 비저항 측정 정밀 정확도에 미치는 영향)

  • Kang, Jeon-Hong;Yu, Kwang-Min;Kim, Han-Jun;Han, Sang-Ok;Kim, Jong-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.267-269
    • /
    • 2003
  • 반도체 웨이퍼 및 각종 박막의 면/비저항(sheet/resistivity resistance)의 측정에 비교적 간단히 측정할 수 있고 측정정확도가 높은 4탐침(four-point probe)방법이 널리 사용되고 있다 또한 4탐침 측정방법은 높은 분해능의 contour map작성과 ion implantation의 doping accuracy 및 doping uniformity의 측정에도 사용된다. 최근 재료의 소형, 박막화 경향으로 볼 때 정확한 비저항 측정의 필요성이 요구되고 있으며 이에 따라 4탐침 측정기술인 single 및 dual configuration method로 실리콘 웨이퍼에 대한 비저항의 측정 정확도를 고찰한 결과 dual configuration 측정방법이 single configuration측정 방법에 비하여 정밀 정확도가 더 좋은 것으로 고찰되었다.

  • PDF

Automatic Control Point Measurement and Photo Orientation via Matching with Control Patch

  • Jaw, Jen-Jer;Wu, Yi-Shen
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.375-377
    • /
    • 2003
  • In this study, we employ the control patches, which have been created in previous photogrammetric projects, serving for the candidates of the control points that are likely to be found in the newly taken photos by utilizing image matching technique. Among others, the successful implementation of the above idea lies in the underlying factors: (1). Predicting the control patches and projecting them onto new photos; (2). Alignment of control patches with respect to the new photos; (3). Generating the equivalent ground elements of control patches versus the new photos for the purpose of correlation; (4). Developing effective matching methods and matching strategy; (5). Refining the exterior orientation parameters. What may show significance in this work comparing to traditional aerial-triangulation chain is that whenever at least three matched control patches succeed in a single photo, it follows that single photo orientation is applicable. The experiments suggest the potential efficiency of automatic control point measurement from control patch database and photo orientation by the proposed workflow.

  • PDF

Precision Profile Measurement on Roughly Processed Surfaces (거친 가공표면 형상의 고정밀 측정법 개발)

  • Kim, Byoung-Chang;Lee, Se-Han
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.1
    • /
    • pp.47-52
    • /
    • 2008
  • We present a 3-D profiler specially devised for the profile measurement of rough surfaces that are difficult to be measured with conventional non-contact interferometer. The profiler comprises multiple two-point-diffraction sources made of single-mode optical fibers. Test measurement proves that the proposed profiler is well suited for the warpage inspection of microelectronics components with rough surface, such as unpolished backsides of silicon wafers and plastic molds of integrated-circuit chip package.

  • PDF

Precision Analysis of the Depth Measurement System Using a Single Camera with a Rotating Mirror (회전 평면경과 단일 카메라를 이용한 거리측정 시스템의 정밀도 분석)

  • ;;;Chun Shin Lin
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.11
    • /
    • pp.626-633
    • /
    • 2003
  • Theoretical analysis of the depth measurement system with the use of a single camera and a rotating mirror has been done. A camera in front of a rotating mirror acquires a sequence of reflected images, from which depth information is extracted. For an object point at a longer distance, the corresponding pixel in the sequence of images moves at a higher speed. Depth measurement based on such pixel movement is investigated. Since the mirror rotates along an axis that is in parallel with the vertical axis of the image plane, the image of an object will only move horizontally. This eases the task of finding corresponding image points. In this paper, the principle of the depth measurement-based on the relation of the pixel movement speed and the depth of objects have been investigated. Also, necessary mathematics to implement the technique is derived and presented. The factors affecting the measurement precision have been studied. Analysis shows that the measurement error increases with the increase of depth. The rotational angle of the mirror between two image-takings also affects the measurement precision. Experimental results using the real camera-mirror setup are reported.

The Phase Transition of Pb5Ge3O11 Single Crystal by the Thermal Conduction Measurement (열전도 측정에 의한 Pb5Ge3O11 단결정의 상전이)

  • Joung, Maeng-Sig
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.4 no.2
    • /
    • pp.165-169
    • /
    • 1999
  • The thermal diffusivity of lead germanate single crystal was measured from room temperture up to the $200^{\circ}C$ by heating method. The thermal diffusivities were measured as k=0.0117, 0.0105, and $0.0112cm^2/^{\circ}C$ at $30^{\circ}C$, $177^{\circ}C$, and $180^{\circ}C$, respectively. It is identified that the heat capacity of the lead germanate single crystal is maximum at $177^{\circ}C$, and this point is phase transition temperature of $Pb_5Ge_3O_{11}$ single crystal.

  • PDF

Experimental Study on the Thermal Characteristics in Ondol Heating Systems (온돌난방주택의 난방방식별 열 특성에 관한 실험연구)

  • 윤정숙
    • Journal of the Korean housing association
    • /
    • v.1 no.1
    • /
    • pp.91-102
    • /
    • 1990
  • The aim of this study is to discover thermal characteristics of Ondol heating systems. The housing subjected was categorized into detached single family houses and apartments, reinforced concrete and brick structures, intermittent and continous heating system, and the space subjected was bedroom. In order to understand the thermal characteristics of each floor heating systems, the vertical distribution of indoor temperature and the distribution of surface temperature on the floor were measured. The vertical distribution of indoor temperature except the measurement point 1 largely showed average temperature distribution, and the temperature of the measurement point 1 in the housing surveyed showed the highest temperature in the house "sample A" because of the radiation heating from the floor of the Ondol room. As the result of the measurement, the thermal characteristics of each heating system were more stable distribution in apartments of R.C structure.structure.

  • PDF

Development of optical temperature distribution measurement system for Underground Power Transmission tunnel (지중선로의 분포 온도 측정 시스템 개발)

  • Lee, Keun-Yang;Song, Woo-Sung
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.766-768
    • /
    • 1998
  • Optical Temperature Distribution measurement System (OTDS) is completely different from conventional electric point sensor in that it uses the optical fiber itself as the sensor. This new concept in temperature measuring system requires only one fiber to be laid. The use of optical fiber also gives the advantage of small diameter, light weight, explosion resistance, and electromagnetic noise resistance. The OTDS is a sensor which is capable of making a precise measurement over a wide range of areas using only a single optical fiber. Since current temperature sensors, such as the thermocouple, are only used to measure temperaturea of point, they are almost impractical for measuring a wider range because of the extremely high cost. In comparision with current sensors, the optical fiber distributed temperature sensor can make much quicker and more precise measurements at a comparatively low cost.

  • PDF

An Examination of Sediment Discharge Computation Errors Related to Imprecise Factors (부정확한 인자와 관계된 유사량 산정 오류에 대한 검증)

  • 정관수
    • Water for future
    • /
    • v.29 no.3
    • /
    • pp.129-142
    • /
    • 1996
  • This study investigates the magnitude of errors that can be expected in integrating sediment concentration in a vertical, basede on a single-point measurement, because of errors in input data. Potential error sources, including sampler location, water surface elevation, bed elevation, fall velocity, $\beta$ value, and $\kappa$ value were comparatively examined using data from a special study on the Rio Grande Conveyance channel in New Mexico. It is concluded that simple forms of equations for the vertical distribution of velocity and sediment concentration based on a single-point field sample of suspended sediment. The most uncertain point in the computation is related to the Rouse number z in the equation for the vertical concentration distribution of suspended sediment.

  • PDF

Performance Expectation of Single Station PPP-RTK using Dual-frequency GPS Measurement in Korea

  • Ong, Junho;Park, Sul Gee;Park, Sang Hyun;Park, Chansik
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.10 no.3
    • /
    • pp.159-168
    • /
    • 2021
  • Precise Point Positioning-Real Time Kinematic (PPP-RTK) is an improved PPP method that provides the user receiver with satellite code and phase bias correction information in addition to the satellite orbit and clock, thus enabling single-receiver ambiguity resolution. Single station PPP-RTK concept is special case of PPP-RTK in that corrections are computed, instead of a network, by only one single GNSS receiver. This study is performed to experimentally verify the positioning accuracy performance of single baseline RTK level by a user who utilizes correction for a single station PPP-RTK using dual frequencies. As an experimental result, the horizontal and vertical 95% accuracy was 2.2 cm, 4.4 cm, respectively, which verify the same performance as the single baseline RTK.

Distance Measurement Using a Single Camera with a Rotating Mirror

  • Kim Hyongsuk;Lin Chun-Shin;Song Jaehong;Chae Heesung
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.4
    • /
    • pp.542-551
    • /
    • 2005
  • A new distance measurement method with the use of a single camera and a rotating mirror is presented. A camera in front of a rotating mirror acquires a sequence of reflected images, from which distance information is extracted. The distance measurement is based on the idea that the corresponding pixel of an object point at a longer distance moves at a higher speed in a sequence of images in this type of system setting. Distance measurement based on such pixel movement is investigated. Like many other image-based techniques, this presented technique requires matching corresponding points in two images. To alleviate such difficulty, two kinds of techniques of image tracking through the sequence of images and the utilization of multiple sets of image frames are described. Precision improvement is possible and is one attractive merit. The presented approach with a rotating mirror is especially suitable for such multiple measurements. The imprecision caused by the physical limit could be improved through making several measurements and taking an average. In this paper, mathematics necessary for implementing the technique is derived and presented. Also, the error sensitivities of related parameters are analyzed. Experimental results using the real camera-mirror setup are reported.