• Title/Summary/Keyword: single phase induction motor

Search Result 220, Processing Time 0.024 seconds

Characteristic Analysis of Capacitor-Run Single-Phase Pole Change Induction Motor Considering Harmonics (고조파를 고려한 극변환(2/4극) 콘덴서 구동형 단상유도전동기 특성해석)

  • Nam, Hyuk;Hong, Jung-Pyo;Jeong, Seung-Kyu;Jung, Tae-Uk;Baek, Seung-Myun
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.907-909
    • /
    • 2001
  • This paper proposes the analysis method for the pole change motor that is a capacitor-run single-phase induction motor. As the Magneto motive force(MMF) at 2-role becomes severe distortion, it is necessary to consider the harmonics for the characteristic analysis of the motor. Therefore, the performance of motor is analyzed by equivalent circuit considering the harmonic components. The validity of the proposed analysis method for the pole change motor is verified through simulations and experimental results.

  • PDF

Induction Motor with Permanent Magnet Rotor (영구자석회전자를 가진 유도전동기)

  • Han, S.D.;Shin, H.J.;Ahn, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.120-122
    • /
    • 2004
  • In this Paper, high efficiency dual air-gap induction motor with permanent magnet rotor is described. The finite element method is used to design the rotor and magnet. And we presented the analysis, construction, experimental results of prototype single phase induction motor with permanent magnet rotor for air-conditioner fan motor.

  • PDF

Detection of Incipient Faults in Induction Motors using FIS, ANN and ANFIS Techniques

  • Ballal, Makarand S.;Suryawanshi, Hiralal M.;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.181-191
    • /
    • 2008
  • The task performed by induction motors grows increasingly complex in modern industry and hence improvements are sought in the field of fault diagnosis. It is essential to diagnose faults at their very inception, as unscheduled machine down time can upset critical dead lines and cause heavy financial losses. Artificial intelligence (AI) techniques have proved their ability in detection of incipient faults in electrical machines. This paper presents an application of AI techniques for the detection of inter-turn insulation and bearing wear faults in single-phase induction motors. The single-phase induction motor is considered a proto type model to create inter-turn insulation and bearing wear faults. The experimental data for motor intake current, rotor speed, stator winding temperature, bearing temperature and noise of the motor under running condition was generated in the laboratory. The different types of fault detectors were developed based upon three different AI techniques. The input parameters for these detectors were varied from two to five sequentially. The comparisons were made and the best fault detector was determined.

Reduction of Components in New Family of Diode Clamp Multilevel Inverter Ordeal to Induction Motor

  • Angamuthu, Rathinam;Thangavelu, Karthikeyan;Kannan, Ramani
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.1
    • /
    • pp.58-69
    • /
    • 2016
  • This paper describes the design and implementation of a new diode clamped multilevel inverter for variable frequency drive. The diode clamp multilevel inverter has been widely used for low power, high voltage applications due to its superior performance. However, it has some limitations such as increased number of switching devices and complex PWM control. In this paper, a new topology is proposed. New topology requires only (N-1) switching devices and (N-3) clamping diodes compared to existing topology. A modified APO-PWM control method is used to generate gate pulses for inverter. The proposed inverter topology is coupled with single phase induction motor and its performance is tested by MATLAB simulation. Finally, a prototype model has built and its performance is tested with single phase variable frequency drive.

Performance Tests of an Induction Motor with Hexahedron HTS Bulk Bearing (고온초전도 벌크 베어링을 사용한 유도 전동기의 특성 시험)

  • 임형우;이광윤;박명진;차귀수;이지광
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.6
    • /
    • pp.286-290
    • /
    • 2003
  • The high temperature superconducting bulk can be used as the bearing of induction motors. This paper presents the fabrication and test results of an induction motor with superconducting bearings using HTS bulks. The bearing had eight hexahedron type YBCO bulks. Height, width and thickness of the HTS bulk were 30mm, 30mm and 10mm, respectively. Single phase induction motor was used to drive the shaft made of aluminum and the rotor of a conventional induction motor. To estimate the performance of the HTS bulk magnetic bearing, no load test, load test and Impact test were carried out. Load tests were performed by using air resistance caused by the shaft-mounted thin cylinder with buckets. Impact tests by axial direction and vertical direction impact showed that the vibration of the shaft gradually decayed. The induction motor with HTS bulk magnetic bearing rotated silently and smoothly throughout the tests. According to the test results, conventional bearings can be replaced with superconducting magnetic bearings made of HTS bulks.

Characteristic Study on Single to Three Phase Conversion Using Single Phase Inverter (단상 Inverter를 사용한 단상/3상 상변환기구와 그 특성에 관한 연구)

  • 이승원;남부희
    • 전기의세계
    • /
    • v.27 no.3
    • /
    • pp.47-52
    • /
    • 1978
  • This paper deals with the phase converter. The single-phase inverter with 120.deg.C phase-lagging is used for the phase conversion. As the waveform of the inverter is rectangular, the output waveforms of the three-phase lines include the harmonics. Single-phase operation by using phase converter and three-phase balanced operation of the three-phase induction motor are compared, and the effects of the harmonics are analyzed and discussed.

  • PDF

Comparison of the Single-phase Line-start Permant Magnet Motor's Transient Characteristics by Size and Position of Rotor Bar (영구자석 매입형 단상 유도 동기 전동기의 회전자 바의 크기와 위치에 따른 기동 특성 비교)

  • Kwon, S.H.;Yang, B.Y.;Kwon, B.I.;Lee, C.G.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.933-935
    • /
    • 2003
  • The single-phase line start permanent magnet motor(LSPM) have a rotor cage bar for induction starting and permanent magnets, providing synchronous torque. So, LSPM is vary complex and difficult to analysis transient characteristics and rotor design. In this paper, F.E.M analysis about single-phase line start permanent magnet motor and compare of the single-phase line start permanent magnet synchronous motor's transient characteristics by size and position of rotor bar.

  • PDF

Comparison of Starting Current Characteristics for Three-Phase Induction Motor Due to Phase-control Soft Starter and Asynchronous PWM AC Chopper

  • Thanyaphirak, Veera;Kinnares, Vijit;Kunakorn, Anantawat
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1090-1100
    • /
    • 2017
  • This paper presents the comparison of starting current characteristics of a three-phase induction motor fed by two types of soft starters. The first soft starter under investigation is a conventional AC voltage controller on the basis of a phase-control technique. The other is the proposed asynchronous PWM AC chopper which is developed from the conventional synchronous PWM AC chopper. In this paper, the proposed asynchronous PWM AC chopper control scheme is developed by generating only two asynchronous PWM signals for a three-phase main power circuit (6 switching devices) from a single voltage control signal which is compared with a single sawtooth carrier signal. By this approach, the PWM signals are independent and easy to implement since the PWM signals do not need to be synchronized with a three-phase voltage source. Details of both soft starters are discussed. The experimental and simulation results of the starting currents are shown. It is found that the asynchronous PWM AC chopper efficiently works as a suitable soft starter for the three-phase induction motor due to that the starting currents are reduced and are sinusoidal with less harmonic contents, when being compared with the starting current waveforms using the conventional phase-control starting technique. Also the proposed soft starter offers low starting electromagnetic torque pulsation.

Analysis of winding currents for three phase induction motor connected to single phase supply (단상 전원에 접속된 3상 유도전동기의 권선전류 분석)

  • Kim, Do-Jin;Kang, Sang-Soo;Kang, Nam-Ho;Jwa, Chong-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.824-825
    • /
    • 2008
  • This paper analyzes the stator winding currents of a three phase induction motor which is connected to the single phase supply. Two stator configurations, Steinmetz connection and modified Steinmetz connection, are respectively employed. In each case, the phase converter reactance at starting is determined using the condition of minimum voltage unbalance factor. By using this reactance, the stator winding currents of each connection are computed and compared with the results of three phase balanced operation.

  • PDF

The Starting Characteristics Improvement of Single-Phase Induction Motor Reducing Over Current

  • Baek, Hyung-Lae;Oh, Keum-Gon;Cho, Geum-Bae;Park, Su-Kang;Lim, Yang-Su
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.531-533
    • /
    • 1996
  • The most common method of the single phase induction motor(SPIM) is to install a starting condenser and a centrifugal switch in series with the auxiliary winding. Even though this capacitor start method is embodied simply, it is feasible because of motor failure from malfunction of the centrifugal switch and the starting condenser. Moreover, it is hard to improve the performance characteristics of the SPIM. In this paper, the voltage and phase angle sequence, control strategy of the auxiliary winding of the SFIM is employed to eliminate the centrifugal switch and the starting condenser. The proposed control system is superior to a conventional system in the starting performance of SPIM. Finally, the improved starting characteristics of the SPIM is obtained with this strategy through simulation and experimental results.

  • PDF