• Title/Summary/Keyword: single bus

Search Result 261, Processing Time 0.025 seconds

A Study on the Feeder Transit Route Design System (대중교통 지선노선 선정기법에 관한 연구)

  • 배기목
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2003.05a
    • /
    • pp.316-321
    • /
    • 2003
  • The bus as a feeder trip should supply equality service to the whole community. But in spite of the change of latent demand to the bus by the variety of regional structural change, the existing bus route can not supply effective feeder service. For cope with the latent demand to the bus, this study establish a concept that frame the feeder bus route design system for changing of the existing bus route or creating of bus route. The concept of feeder bus route design system from this study is not to frame the whole bus network but to frame the single route to a unit OD pair. So, this study have assumption that do not consider the wating time at bus stop and transfer time. This system is consist of three phase. First is limitation of examination road network, second is enumeration of a most suitable route, and final is determination of the optimum bus route. However, a precondition is that the necessary time from the origin to the destination is brief, and having many demand.

  • PDF

Three-Port Converters with a Flexible Power Flow for Integrating PV and Energy Storage into a DC Bus

  • Cheng, Tian;Lu, Dylan Dah-Chuan
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1433-1444
    • /
    • 2017
  • A family of non-isolated DC-DC three-port converters (TPCs) that allows for a more flexible power flow among a renewable energy source, an energy storage device and a current-reversible DC bus is introduced. Most of the reported non-isolated topologies in this area consider only a power consuming load. However, for applications such as hybrid-electric vehicle braking systems and DC microgrids, the load power generating capability should also be considered. The proposed three-port family consists of one unidirectional port and two bi-directional ports. Hence, they are well-suited for photovoltaic (PV)-battery-DC bus systems from the power flow viewpoint. Three-port converters are derived by combining different commonly known power converters in an integrated manner while considering the voltage polarity, voltage levels among the ports and the overall voltage conversion ratio. The derived converter topologies are able to allow for seven different modes of operation among the sources and load. A three-port converter which integrates a boost converter with a buck converter is used as a design example. Extensions of these topologies by combining the soft-switching technique with the proposed design example are also presented. Experiment results are given to verify the proposed three-port converter family and its analysis.

Direct Calculation of A Matrix of Single Machine Connected to Infinite Bus : Including Excitation System (발전기-무한모선계통의 A행열의 직접 계산법 : 여자계통을 고려한 경우)

  • Kwon, Sae-Hyuk;Kim, Dug-Young
    • Proceedings of the KIEE Conference
    • /
    • 1989.07a
    • /
    • pp.216-220
    • /
    • 1989
  • Direct calculation algorithm for the elements of A matrix is suggested for a single machine connected to the infinite bus. Excitation system and power system stabilizer are included. When A matrix is partitioned into seven submatrices, we can identify the location of non-zero elements and formula for each element. No matrix inversion and multiplication are necessary.

  • PDF

Study on the Security-Constrained Optimal Power Flow (상정사고를 고려한 최적조류계산 연구)

  • Choi, Kil;Won, Jong-Ryul
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.381-383
    • /
    • 2002
  • This paper proposes a MATLAB program for solving security-constrained optimal power flow using linear programming. Security-constrained optimal power flow can find an optimal generation satisfying bus voltage limits, line flow limits, reactive generation limits, even if contingency occurs. Sensitivity matrixes are obtained based on power flow solutions with and without single line contingency. This program is tested for an IEEE 14bus system with 5 generators Results shows good ability of finding optimal solution in case of a single line contingency.

  • PDF

On Installation of Bus Trunk System for Wind Tower (풍력타워용 부스닥트 포설시스템 개발)

  • Lee, Joon-Keun;Kim, Bong-Seok;Park, Seong-Hee;Ahn, Hyung-Joon;Lee, Hee-Nam
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.330-335
    • /
    • 2012
  • A Bus Trunk System for Wind Tower is introduced. A marine cable has been widely used in wind tower or other offshore structure. However, as the electric load capacity is getting increased, the large number of cable lines should be used to cover such a huge amount of electric capacities, which makes the installation make quite difficult due to the heavy weight and volume of the present cables. On the other hand, by using a single bus trunk system line, the power capacity amount of 16 number of cable can be delivered with significant compactness. However, unlike flexible cable, the bus trunk is relatively stiff which could arise resonance phenomenon in the operating condition of wind tower, therefore, the vibration characteristics of bus trunk should be investigated and verify its long-term reliability during the life time of the wind tower.

  • PDF

A Design of Interface Module for Multiple Level MIL-STD-1553 Bus Topology (다중 MIL-STD-1553 버스 구조를 위한 인터페이스 모듈의 설계)

  • Seung Gi-Taek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.6
    • /
    • pp.1045-1054
    • /
    • 2006
  • In this paper, described a design result of bus interface modulo for multiple level MU-SID-1553 data bus network. In general, MIL-SID-1553 network is used for single level data bus topology. But, according to applied system's structure. multiple level bus architecture is required., And for his, micro processor must be involved for system be, and a additional hardware and software functions are needed. The designed data bus interface module is simply consists of communication transceivers and simple electronic circuit without micro processor. Through the hardware testing and software simulation, the functional performance of the designed interface module was successfully validated.

Analytic performance evaluation of the IEEE 802.4 token bus network with finite buffer capacity (제한된 버퍼를 가진 IEEE 802.4 토큰 버스 네트워크의 성능 해석)

  • 문상용;박홍성;권욱현
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.407-410
    • /
    • 1997
  • This paper analytically derives the variance of service time of a station in the symmetric IEEE 802.4 token bus network with single access class and finite buffer capacity. This performance measure is represented in terms of the total number of stations, the token hold time, the arrival rate of frames, the service rate, and other parameters. Using computer simulations, presented performance measure is validated.

  • PDF

A Development of Multi-Period Bus Scheduling Model (다시간대에 대한 버스 스케줄링 모형 개발)

  • 고종섭;고승영
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.4
    • /
    • pp.47-58
    • /
    • 1999
  • The Purpose of this Paper is to develop a multi-period bus scheduling model, in which a decomposition technique is applied. In general a bus scheduling requires a vast amount of calculation. Thus, a bus scheduling is a very complicated problem even with a single depot and is almost unable to obtain the optimal solution theoretically with many depots. In this paper in order to simplify the problem, the whole operating hours of a day are partitioned into several time periods. In one period, the same headways are maintained. For one period, the bus scheduling is simple and the solution applying the FIFO(First-In, First-Out) Principle is the optimal. However, connection between Periods remains as another scheduling Problem with a reduced problem size. This paper suggests how to connect bus schedules of consecutive periods efficiently, minimizing the operating cost. Through case studies for multiple routes with a single depot, this decomposition technique is proved to be effective practically.

  • PDF

Design and Implementation of e2eECC for Automotive On-Chip Bus Data Integrity (차량용 온칩 버스의 데이터 무결성을 위한 종단간 에러 정정 코드(e2eECC)의 설계 및 구현)

  • Eunbae Gil;Chan Park;Juho Kim;Joonho Chung;Joosock Lee;Seongsoo Lee
    • Journal of IKEEE
    • /
    • v.28 no.1
    • /
    • pp.116-122
    • /
    • 2024
  • AMBA AHB-Lite bus is widely used in on-chip bus protocol for low-power and cost-effective SoC. However, it lacks built-in error detection and correction for end-to-end data integrity. This can lead to data corruption and system instability, particularly in harsh environments like automotive applications. To mitigate this problem, this paper proposes the application of SEC-DED (Single Error Correction-Double Error Detection) to AMBA AHB-Lite bus. It aims not only to detect errors in real-time but also to correct them, thereby enhancing end-to-end data integrity. Simulation results demonstrate real-time error detection and correction when errors occur, which bolsters end-to-end data integrity of automotive on-chip bus.

The Expansion of Bus Networks Connecting Incheon International Airport (인천국제공항 운행버스 노선망의 형성과 그 요인)

  • Han, Ju-Seong
    • Journal of the Korean Geographical Society
    • /
    • v.43 no.4
    • /
    • pp.544-560
    • /
    • 2008
  • This study seeks to clarify the background and factors for the expansion of bus networks that connect Incheon International Airport with its hinterlands. For this research objective, this paper analyzes the relationships among the change of bus routes, competitive transportation modes, passenger fares, and the shortest time distance. Previously, the hinterlands of route bus networks that connect Gimpo International Airport were Seoul metropolitan area, Chungcheong region, Jeonju and Iksan in Jeollabuk-do(province). However, the opening of Incheon International Airport resulted in the expansion of the hinterlands of bus networks to Gangwon-do, Gwangju, and major cities in Youngnam region. Simultaneously, route bus networks also expanded in Seoul metropolitan area. Each bus route connecting Incheon International Airport with its hinterlands was opened by a single bus company or various bus companies. In many cases, due to the uncertainty of revenues or bus company's regional ties, a bus route was opened by various bus companies. In this paper, the analysis of the number of one-way route bus service and density of flight passengers shows that the frequency of the route bus service for Seoul except Gangseo-gu(ward) and for Seoul's satellite cities(Suwon, Seongnam, Anyang, Gunpo, Guri, and Osan) should be decreased. The analysis also shows that the frequency of the route bus services for the other cities, counties(Guns), and wards(gus) should be increased. In Seoul metropolitan area, although route bus fares are more expensive than subway fares, passengers use route bus more frequency than subway because time distance of route bus is shorter than that of subway and subway transfer is inconvenient. In general, outside Seoul metropolitan area, air flight is preferred in the regions that have airports. In contrast, the route bus is preferred in Daegu and other regions that do not have airports.