• Title/Summary/Keyword: simultaneous resonance

Search Result 84, Processing Time 0.025 seconds

Magnetic Resonance Imaging (MRI) of a Hypertrophy of Cartilage and Simultaneous Regeneration of a Damaged Meniscus after Autologous Bone Marrow Aspirates Concentrate (BMAC) Transplantation: a Case Report and Literature Review

  • Bae, Sung Hwan;Kim, Hyun-joo;Oh, Eunsun;Hwang, Jiyoung;Hong, Seong Sook;Hwang, Jung Hwa
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.3
    • /
    • pp.187-191
    • /
    • 2017
  • Bone marrow aspirates concentrate (BMAC) transplantation is a well-known technique for cartilage regeneration with good clinical outcomes for symptoms in patients with osteoarthritis (OA). Magnetic resonance imaging (MRI) has an important role in evaluating the degree of cartilage repair in cartilage regeneration therapy instead of a second assessment via an arthroscopy. We experienced a case of hypertrophic regeneration of the cartilage and a presumed simultaneous regeneration of the posterior horn of the lateral meniscus after BMAC transplantation for a cartilage defect at the lateral tibial and femoral condyle. This report provides the details of a case of an unusual treatment response after a BMAC transplant. This report is the first of its kind to demonstrate a MR image that displays the simultaneous regeneration of the cartilage and meniscus with a differentiation ability of the mesenchymal stem cell to the desired cell lineage.

Simultaneous resonances of SSMFG cylindrical shells resting on viscoelastic foundations

  • Foroutan, Kamran;Ahmadi, Habib
    • Steel and Composite Structures
    • /
    • v.37 no.1
    • /
    • pp.51-73
    • /
    • 2020
  • The present paper investigates the simultaneous resonance behavior of spiral stiffened multilayer functionally graded (SSMFG) cylindrical shells with internal and external functionally graded stiffeners under the two-term large amplitude excitations. The structure is embedded within a generalized nonlinear viscoelastic foundation which is composed of a two-parameter Winkler-Pasternak foundation augmented by a Kelvin-Voigt viscoelastic model with a nonlinear cubic stiffness. The cylindrical shell has three layers consist of ceramic, FGM, and metal. The exterior layer of the cylindrical shell is rich ceramic while the interior layer is rich metal and the functionally graded material layer is located between these layers. With regard to classical shells theory, von-Kármán equation, and Hook law, the relations of stress-strain are derived for shell and stiffeners. The spiral stiffeners of the cylindrical shell are modeled according to the smeared stiffener technique. According to the Galerkin method, the discretized motion equation is obtained. The simultaneous resonance is obtained using the multiple scales method. Finally, the influences of different material and geometrical parameters on the system resonances are investigated comprehensively.

Spinal Subdural Hematoma Associated with Intracranial Subdural Hematoma

  • Kim, Myoung Soo;Sim, Sook Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.4
    • /
    • pp.397-400
    • /
    • 2015
  • The simultaneous occurrence of an intracranial and a spinal subdural hematoma (SDH) is rare. We describe a case of cranial SDH with a simultaneous spinal SDH. An 82-year-old woman visited the emergency room because of drowsiness and not being able to walk 6 weeks after falling down. A neurological examination showed a drowsy mentality. Brain computed tomography showed bilateral chronic SDH with an acute component. The patient underwent an emergency burr-hole trephination and hematoma removal. She exhibited good recovery after the operation. On the fourth postoperative day, she complained of low-back pain radiating to both lower limbs, and subjective weakness of the lower limbs. Spine magnetic resonance imaging revealed a thoracolumbosacral SDH. A follow-up spinal magnetic resonance imaging study that was performed 16 days later showed a significant decrease in the size of the spinal SDH. We discuss the pathogenesis of this simultaneous occurrence of spinal and cranial SDH.

Bandwidth Enhancement for SSN Suppression Using a Spiral-Shaped Power Island and a Modified EBG Structure for a ${\lambda}$/4 Open Stub

  • Kim, Bo-Bae;Kim, Dong-Wook
    • ETRI Journal
    • /
    • v.31 no.2
    • /
    • pp.201-208
    • /
    • 2009
  • This paper proposes a spiral-shaped power island structure that can effectively suppress simultaneous switching noise (SSN) when the power plane drives high-speed integrated circuits in a small area. In addition, a new technique is presented which greatly improves the resonance peaks in a stopband by utilizing ${\lambda}$/4 open stubs on a conventional periodic electromagnetic bandgap (EBG) power plane. Both proposed structures are simulated numerically and experimentally verified using commercially available 3D electromagnetic field simulation software. The results demonstrate that they achieve better SSN suppression performance than conventional periodic EBG structures.

  • PDF

Simultaneous Switching Noise Reduction Technique in Multi-Layer Boards using Conductive Dielectric Substrate (전도성 유전기판을 이용한 다층기판에서의 Simultaneous Switching Noise 감소 기법)

  • 김성진;전철규;이해영
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.6 no.4
    • /
    • pp.9-14
    • /
    • 1999
  • In this paper, we proposed a simultaneous switching noise (SSN) reduction technique in multi-layer boards (MLB) for high-speed digital applications and analyzed it using the Finite Difference Time Domain (FDTD) method. The new structure using conductive dielectric substrates is effective for the reduction of SSN couplings and resonances. The uniform insertion of the conducive layer reduced the SSN coupling and resonance by 85% and the partial insertion only around the edges reduced by 55% respectively.

  • PDF

Simultaneous Bilateral Quadriceps Tendon Rupture in Patient with Secondary Hyperparathyroidism due to Chronic Renal Failure: A Case Report (만성신부전증에 의한 이차성 부갑상선기능항진증 환자에서 양쪽 대퇴사두건 동시 파열: 증례 보고)

  • Shim, Jong-Joon;Shim, Jae-Chan;Ha, Jeong-Ju;Lee, Kyoung-Eun;Lee, Ghi-Jai;Kim, Ho-Kyun;Suh, Jung-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.2
    • /
    • pp.169-172
    • /
    • 2012
  • Simultaneous bilateral spontaneous rupture of the quadriceps tendon is a very rare condition and only a few cases have been reported in the literature. The etiology is not clear yet. But it occurs infrequently in patients with chronic metabolic disorders, such as secondary hyperparathyroidism due to chronic renal failure. We describe a case of simultaneous spontaneous bilateral quadriceps tendon tupture in a 36-year-old male patient with secondary hyperaprathyroidism due to chronic renal failure.

Dynamic Cardiac Magnetic Resonance Fingerprinting During Vasoactive Breathing Maneuvers: First Results

  • Luuk H.G.A. Hopman;Elizabeth Hillier;Yuchi Liu;Jesse Hamilton;Kady Fischer;Nicole Seiberlich;Matthias G. Friedrich
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.2
    • /
    • pp.71-82
    • /
    • 2023
  • BACKGROUND: Cardiac magnetic resonance fingerprinting (cMRF) enables simultaneous mapping of myocardial T1 and T2 with very short acquisition times. Breathing maneuvers have been utilized as a vasoactive stress test to dynamically characterize myocardial tissue in vivo. We tested the feasibility of sequential, rapid cMRF acquisitions during breathing maneuvers to quantify myocardial T1 and T2 changes. METHODS: We measured T1 and T2 values using conventional T1 and T2-mapping techniques (modified look locker inversion [MOLLI] and T2-prepared balanced-steady state free precession), and a 15 heartbeat (15-hb) and rapid 5-hb cMRF sequence in a phantom and in 9 healthy volunteers. The cMRF5-hb sequence was also used to dynamically assess T1 and T2 changes over the course of a vasoactive combined breathing maneuver. RESULTS: In healthy volunteers, the mean myocardial T1 of the different mapping methodologies were: MOLLI 1,224 ± 81 ms, cMRF15-hb 1,359 ± 97 ms, and cMRF5-hb 1,357 ± 76 ms. The mean myocardial T2 measured with the conventional mapping technique was 41.7 ± 6.7 ms, while for cMRF15-hb 29.6 ± 5.8 ms and cMRF5-hb 30.5 ± 5.8 ms. T2 was reduced with vasoconstriction (post-hyperventilation compared to a baseline resting state) (30.15 ± 1.53 ms vs. 27.99 ± 2.07 ms, p = 0.02), while T1 did not change with hyperventilation. During the vasodilatory breath-hold, no significant change of myocardial T1 and T2 was observed. CONCLUSIONS: cMRF5-hb enables simultaneous mapping of myocardial T1 and T2, and may be used to track dynamic changes of myocardial T1 and T2 during vasoactive combined breathing maneuvers.

A Novel Method of All-Optical Switching: Quantum Router

  • Ham, Byoung-Seung
    • ETRI Journal
    • /
    • v.23 no.3
    • /
    • pp.106-110
    • /
    • 2001
  • Subpicosecond all-optical switching method based on the simultaneous two-photon coherence exchange is proposed and numerically demonstrated. The optical switching mechanism is based on the optical field induced dark resonance swapping via nondegenerate four-wave mixing processes. For potential applications of ultrafast all-optical switching in fiber-optic communications, 10-THz channel number independent quantum router is discussed.

  • PDF

Simultaneous Medial and Lateral Discoid Meniscus in one Knee joint (한쪽 슬관절에서 내측 및 외측에 동시에 발생한 원판형 연골 - 1예 보고 -)

  • Cho, Young-Ho;An, Hyug-Su;Chang, Se-Ang;Nam, Seung-Oh
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.95-98
    • /
    • 2006
  • Most of discoid menisci are lateral and medial discoid meniscus is very rare. There is no report about simultaneous medial and lateral discoid meniscus in one knee joint. A 15-year-old male patient was diagnosed as having a complete medial discoid meniscus with horizontal tear and intact incomplete lateral discoid meniscus by means of magnetic resonance image and arthroscopy. The patient was treated by arthroscopic partial meniscectomy for both discoid menisci.

  • PDF