• Title/Summary/Keyword: simultaneous recovery

Search Result 308, Processing Time 0.026 seconds

Resilient Routing Overlay Network Construction with Super-Relay Nodes

  • Tian, Shengwen;Liao, Jianxin;Li, Tonghong;Wang, Jingyu;Cui, Guanghai
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.4
    • /
    • pp.1911-1930
    • /
    • 2017
  • Overlay routing has emerged as a promising approach to improve reliability and efficiency of the Internet. The key to overlay routing is the placement and maintenance of the overlay infrastructure, especially, the selection and placement of key relay nodes. Spurred by the observation that a few relay nodes with high betweenness centrality can provide more optimal routes for a large number of node pairs, we propose a resilient routing overlay network construction method by introducing Super-Relay nodes. In detail, we present the K-Minimum Spanning Tree with Super-Relay nodes algorithm (SR-KMST), in which we focus on the selection and connection of Super-Relay nodes to optimize the routing quality in a resilient and scalable manner. For the simultaneous path failures between the default physical path and the overlay backup path, we also address the selection of recovery path. The objective is to select a proper one-hop recovery path with minimum cost in path probing and measurement. Simulations based on a real ISP network and a synthetic Internet topology show that our approach can provide high-quality overlay routing service, while achieving good robustness.

Simultaneous Analysis of Six Compounds in Yijin-tang by HPLC-PDA (HPLC-PDA을 이용한 이진탕 중 6종 성분의 동시분석)

  • Kim, Seong-Sil;Kim, Jung-Hoon;Shin, Hyeun-Kyoo;Seo, Chang-Seob
    • Herbal Formula Science
    • /
    • v.21 no.1
    • /
    • pp.71-79
    • /
    • 2013
  • Objectives : Yijin-tang has been used in the treatment of gastrointestinal diseases such as irritable bowel syndrome, gastritis, and gastric ulcer. In this study, a high-performance liquid chromatography (HPLC) method was established for simultaneous analysis of six compounds, liquiritin, glycyrrhizin, hesperidin, 6-gingerol, homogentisic acid, and 3,4-dihydroxybenzaldehyde in Yijin-tang, a traditional Korean herbal medicinal preparation. Methods : A Gemini C18 column was used for the separation of six constituents at $40^{\circ}C$. The mobile phase using gradient elution consist of two solvent systems, 1.0% acetic acid in water (A) and 1.0% acetic acid in acetonitrile (B). The flow-rate was 1.0 mL/min and injection volume was $10{\mu}g$. The detector was a photodiode array (PDA) detector set at 254 nm and 280 nm. Results : The calibration curves of six compounds showed good linearity in various concentration ranges ($R^2{\geq}0.9997$). The limits of detection (LOD) and limits of quantification (LOQ) were 0.028-$0.192{\mu}g/mL$ and 0.093-$0.540{\mu}g/mL$, respectively. The RSD (%) of the intra and inter day validations were 0.03-0.84% and 0.05 -1.00%, respectively. Recovery was 96.14-01.90% and RSD (%) was less than 1.5%. Conclusions : The established simultaneous analysis methods will help management to improve the quality of Yijin-tang.

Simultaneous Determination of Creatine, Dicyandiamide and Dihydrotriazine in Dietary Supplements by High Performance Liquid Chromatography (고성능 액체크로마토그래피를 이용한 식이보충제에서 크레아틴, 디시안디아마이드, 디하이드로트리아진의 동시분석)

  • Park, Sang-Wook;Yoo, Myung-Sang;Lee, Wonjae
    • KSBB Journal
    • /
    • v.29 no.4
    • /
    • pp.232-238
    • /
    • 2014
  • The simultaneous determination of creatine monohydrate (CrM), dicyandiamide and dihydrotriazine in dietary supplements using reversed-phase high performance liquid chromatography (HPLC) was developed. Chromatography was performed on a Nuclosil 100-5 SA ($4.6{\times}250mm$) column with a mobile phase of 2.3% ammonium phosphate (pH 5.5), and UV detection at 224 nm, 212 nm, and 237 nm, respectively. The performance characteristics of HPLC were determined in terms of selectivity, linearity, precision, recovery, limit of detection (LOD), and limit of quantification (LOQ). The calibration curves were linear within the concentration range of $40.0{\sim}500.0{\mu}g/mL$ for creatine, $0.1{\sim}12.8{\mu}g/mL$ for dicyandiamide, and $0.05{\sim}6.4{\mu}g/mL$ for dihydrotriazine. The detection limits of the method were 1.09, 0.01, and $0.08{\mu}g/mL$ for creatine, dicyandiamide, and dihydrotriazine, respectively. The recoveries of creatine, dicyandiamide, and dihydrotriazine were 97.2~100.9, 92.3~106.5, and 97.2~105.5%, respectively. It is expected that the chromatographic analytical method developed in this study will be usefully applicable to simultaneous determination of creatine, dicyandiamide, and dihydrotriazine contained in dietary supplements.

Simultaneous Determination of Six Components in the Traditional Herbal Medicine 'Oryeongsan' by HPLC-DAD and LC-MS/MS

  • Lee, Jiwoo;Weon, Jin Bae;Lee, Bohyoung;Yun, Bo-Ra;Eom, Min Rye;Ma, Choong Je
    • Natural Product Sciences
    • /
    • v.19 no.1
    • /
    • pp.20-27
    • /
    • 2013
  • A simple high performance liquid chromatography - diode array detector (HPLC-DAD) method has been developed and validated for simultaneous determination of the six components (cinnamic acid, cinnamaldehyde, eugenol, atractylenolide I, atractylenolide III, and ergosterol) in Oryeongsan. In addition, identification of six marker compounds was conducted by a LC-MS/MS analysis. The six compounds in Oryeongsan were separated on Shishedo $C_{18}$ column (5 ${\mu}m$, $4.6{\times}250$ mm) at a column temperature of $30^{\circ}C$. The mobile phase was a mixture of 0.1% trifluoroacetic acid (TFA) water and acetonitrile employing gradient elution at a flow rate of 1.0 mL/min. The detection wavelength was set at 205, 250, 280, and 330 nm. The developed method had good linearity ($R^2$ > 0.9997) and the limit of detection (LOD) and limit of quantification (LOQ) were observed within the ranges 0.01~0.15 and 0.05~0.45 ${\mu}g/mL$, respectively. The relative standard deviation (RSD) values of intra- and inter-day testing were indicated that less than 3% and 90.31~103.31% of accuracy. The results of recovery test were 90.56~106.72% and RSD range was measured from 0.84 to 2.95%. In conclusion, this HPLC-DAD method has been successfully applied to the simultaneous determination of six compounds in Oryeongsan samples.

Experimental Study on the Performance Improvement of a Simultaneous Heating and Cooling Heat Pump in the Heating-main Operating Mode (난방주체 운전모드에서의 동시냉난방 열펌프 성능향상에 관한 실험적 연구)

  • Kang, Hoon;Jung, Hyen-Joon;Joo, Young-Ju;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.4
    • /
    • pp.245-251
    • /
    • 2008
  • The cooling load in winter is significant in buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Hence, the development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, the operating characteristics and performance of a simultaneous heating and cooling heat pump in the heating-main operating mode were investigated experimentally. The system adopted a variable speed compressor with four indoor units and one outdoor unit with R-410A. In the heating-main mode, the cooling capacity was lower than the design cooling capacity due to the reduction of the flow rate in the indoor unit for the cooling, with the increase of the heating capacity. To solve these problems, the performance characteristics of the simultaneous heating and cooling heat pump in the heating-main mode were investigated by varying the flow rate to the indoor unit for the cooling and the compressor rotating speed. In addition, the adequate control methods were suggested to improve the system efficiency.

Clinical Results Over Time for Unilateral versus Bilateral Simultaneous Short Scarf Osteotomy (편측 또는 양측을 동시에 시행한 단축 스카프 절골술의 시간 경과에 따른 임상적 결과)

  • Jeong, Changhoon;Park, Il-Kyu;Chung, Jin-Wha
    • Journal of Korean Foot and Ankle Society
    • /
    • v.23 no.4
    • /
    • pp.154-158
    • /
    • 2019
  • Purpose: This study compared the radiographic and clinical outcomes of simultaneous bilateral short scarf osteotomy with those of unilateral short scarf osteotomy in hallux valgus patients. Materials and Methods: The authors undertook a retrospective chart and radiographic review between January 2015 and June 2017 to identify 15 patients (30 cases, group A) who underwent a simultaneous bilateral short scarf osteotomy. The patients were matched with 30 patients (30 cases, group B) with a unilateral short scarf osteotomy. No significant preoperative differences were observed between the two groups in terms of age, gender, American Orthopaedic Foot and Ankle Society (AOFAS) hallux score, and radiographic parameters. The clinical and radiographic follow-up was carried out at three months and one year. Results: Hallux valgus angles in groups A and B were reduced from the mean preoperative values of 32.5° and 34.7° to 12.5° and 12.2° at 12 months, respectively. The first-second intermetatarsal angles in groups A and B were also reduced from the mean preoperative values of 14.2° and 16.5° to 7.4° and 7.3° at 12 months, respectively. No significant inter-group differences in radiographic outcomes were observed. After three months, the patients in group A reported significantly worse mean pain and functional scores than group B. The mean AOFAS hallux score was higher in group B at the three-month follow-up, but this difference disappeared at the one-year followup. Conclusion: Simultaneous bilateral surgery can be offered to patients with a hallux valgus deformity requiring correction. On the other hand, they should be informed of the long recovery period.

Simultaneous determination of 30 ginsenosides in Panax ginseng preparations using ultra performance liquid chromatography

  • Park, Hee-Won;In, Gyo;Han, Sung-Tai;Lee, Myoung-Woo;Kim, So-Young;Kim, Kyung-Tack;Cho, Byung-Goo;Han, Gyeong-Ho;Chang, Il-Moo
    • Journal of Ginseng Research
    • /
    • v.37 no.4
    • /
    • pp.457-467
    • /
    • 2013
  • A quick and simple method for simultaneous determination of the 30 ginsenosides (ginsenoside Ro, Rb1, Rb2, Rc, Rd, Re, Rf, Rg1, 20(S)-Rg2, 20(R)-Rg2, 20(S)-Rg3, 20(R)-Rg3, 20(S)-Rh1, 20(S)-Rh2, 20(R)-Rh2, F1, F2, F4, Ra1, Rg6, Rh4, Rk3, Rg5, Rk1, Rb3, Rk2, Rh3, compound Y, compound K, and notoginsenoside R1) in Panax ginseng preparations was developed and validated by an ultra performance liquid chromatography photo diode array detector. The separation of the 30 ginsenosides was efficiently undertaken on the Acquity BEH C-18 column with gradient elution with phosphoric acids. Especially the chromatogram of the ginsenoside Ro was dramatically enhanced by adding phosphoric acid. Under optimized conditions, the detection limits were 0.4 to 1.7 mg/L and the calibration curves of the peak areas for the 30 ginsenosides were linear over three orders of magnitude with a correlation coefficients greater than 0.999. The accuracy of the method was tested by a recovery measurement of the spiked samples which yielded good results of 89% to 118%. From these overall results, the proposed method may be helpful in the development and quality of P. ginseng preparations because of its wide range of applications due to the simultaneous analysis of many kinds of ginsenosides.

In situ Recovery of hGM-CSF in Transgenic Rice Cell Suspension Cultures (형질전환 벼 현탁세포 배양에서 hGM-CSF의 in situ Recovery 연구)

  • Myoung, Hyun-Jong;Choi, Hong-Yeol;Nam, Hyung-Jin;Kim, Dong-Il
    • KSBB Journal
    • /
    • v.30 no.3
    • /
    • pp.103-108
    • /
    • 2015
  • Production of foreign proteins by transgenic plant cell cultures has several advantages such as post-translational modification, low risk of product contamination and low-cost production and purification. However, target proteins are degraded by extracellular proteases existing in the media. A solution to this problem is the use of perfusion culture and ion exchange chromatography for the application of integrated bioprocess using in situ recovery. With this method, production of human granulocyte-macrophage colony-stimulating factor (hGM-CSF) was investigated in this study. First, optimization of cell concentration during the induction phase for the production of hGM-CSF was examined. As cell concentration increased, the level of hGM-CSF was decreased due to the presence of extracellular proteases. Induction using sugarfree media produced 33% more hGM-CSF. The effects of pH on the binding of hGM-CSF to cationic and anionic exchange resins were also investigated. In terms of stability, optimal pH was found to be 5~7. In the case of using buffer exchange when CM-Sepharose was used as a cationic exchange resin, optimal pH for binding was 4.8 and adsorption yield was 77%. When DEAE-Sepharose was used as an anionic exchange resin, it was 5.5 (74%). Without buffer exchange, optimal pH was 4.6 (84%). From these results, an integrated bioprocess using in situ recovery with simultaneous production and separation of foreign protein in transgenic plant cell suspension cultures was found to be feasible.

Simultaneous Unwrapping Phase and Error Recovery from Inhomogeneity (SUPER) for Quantitative Susceptibility Mapping of the Human Brain

  • Yang, Young-Joong;Yoon, Jong-Hyun;Baek, Hyun-Man;Ahn, Chang-Beom
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.1
    • /
    • pp.37-49
    • /
    • 2018
  • Purpose: The effect of global inhomogeneity on quantitative susceptibility mapping (QSM) was investigated. A technique referred to as Simultaneous Unwrapping Phase with Error Recovery from inhomogeneity (SUPER) is suggested as a preprocessing to QSM to remove global field inhomogeneity-induced phase by polynomial fitting. Materials and Methods: The effect of global inhomogeneity on QSM was investigated by numerical simulations. Three types of global inhomogeneity were added to the tissue susceptibility phase, and the root mean square error (RMSE) in the susceptibility map was evaluated. In-vivo QSM imaging with volunteers was carried out for 3.0T and 7.0T MRI systems to demonstrate the efficacy of the proposed method. Results: The SUPER technique removed harmonic and non-harmonic global phases. Previously only the harmonic phase was removed by the background phase removal method. The global phase contained a non-harmonic phase due to various experimental and physiological causes, which degraded a susceptibility map. The RMSE in the susceptibility map increased under the influence of global inhomogeneity; while the error was consistent, irrespective of the global inhomogeneity, if the inhomogeneity was corrected by the SUPER technique. In-vivo QSM imaging with volunteers at 3.0T and 7.0T MRI systems showed better definition in small vascular structures and reduced fluctuation and non-uniformity in the frontal lobes, where field inhomogeneity was more severe. Conclusion: Correcting global inhomogeneity using the SUPER technique is an effective way to obtain an accurate susceptibility map on QSM method. Since the susceptibility variations are small quantities in the brain tissue, correction of the inhomogeneity is an essential element for obtaining an accurate QSM.

Simultaneous Determination of Organo-phosphorus and Organo-chlorinated Pesticides in Soil and Lawn Samples of Golf Courses (골프장 토양 및 잔디 시료 중 유기인 및 유기염소계 농약의 동시 분석)

  • Seo, Yong-Chan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1257-1262
    • /
    • 2005
  • Organo-chlorinated pesticides have been seldom measured in Korea because their use was banned for more than two decades. Nevertheless, the environmental persistency of these pesticides requires regular monitoring. Only organo-phosphorus pesticides are currently being monitored in Korea. Simultaneous determination of organo-chlorinated and organo-phosphorus pesticides was attempted using gas chromatography/mass spectrometer detector. Pressurized fluid extraction(PFE) was used in sample preparation. PFE showed equivalent extraction efficiency to traditional soxhlet extraction with less solvent use and less sample preparation time. Average recovery of spiked pesticides to soil and lawn samples was 62% ranging 52 to 154%. Method detection levels(MDLs) for these pesticides ranged from 3.4 to 10.5 ${\mu}g/kg$. Endosulfan, fenitrothion, and diazinon were found in the samples from 5 different golf courses out of 9 courses.