• 제목/요약/키워드: simultaneous monitoring

검색결과 309건 처리시간 0.028초

항만센서용 수정진동자의 해수에 의한 부식 (Corrosion of Quartz Crystal Marine Sensors in Sea Water)

  • 최광재;장상목;김영한
    • 한국항만학회지
    • /
    • 제12권2호
    • /
    • pp.323-328
    • /
    • 1998
  • A quartz crystal analyzer is utilized to monitor the corrosion process of an aluminum surface of a quartz crystal for marine sensor by sea water. A quartz crystal having 2000 $\AA$ of aluminum layer is installed in a specially designed cell and is in contact with sea water imitated electrolyte solution. While a constant potential is applied to the cell, the resonant frequency and resonant resistance are simultaneously measured using the quartz crystal analyzer. In addition, surface topographs are taken with an atomic force microscope(AFM) and the element analysis of the surface is conducted using an energy dispersive X-ray spectrometer(EDX). The simultaneous measurement of resonant frequency and resonant resistance during the corrosion process explains the change of surface structure caused by the corrosion. The variation of resonant frequency addresses the amount surface metal dissolution. As a conclusion, it is found that a simple measurement using the quartz crystal analyzer can replace the complex monitoring employing large equipments in the investigation of a corrosion process of sensor surface.

  • PDF

Multivariate EWMA Control Chart for Means of Multiple Quality Variableswith Two Sampling Intervals

  • Chang, Duk-Joon;Heo, Sunyeong
    • 통합자연과학논문집
    • /
    • 제5권3호
    • /
    • pp.151-156
    • /
    • 2012
  • Because of the equivalence between control chart procedures and hypothesis testing, we propose to use likelihood ratio test (LRT) statistic $Z_i^2$ as the multivariate control statistic for simultaneous monitoring means of the multivariate normal process. Properties and comparisons of the proposed control charts are explored and conducted for matched fixed sampling interval (FSI) and variable sampling interval (VSI) with two sampling interval charts. The result of numerical comparisons shows that EWMA chart with two sampling interval procedure is more efficient than the corresponding FSI chart for small or moderate changes. When large shift of the process has occurred, we also found that Shewhart chart is more efficient than EWMA chart.

RAVIP: Real-Time AI Vision Platform for Heterogeneous Multi-Channel Video Stream

  • Lee, Jeonghun;Hwang, Kwang-il
    • Journal of Information Processing Systems
    • /
    • 제17권2호
    • /
    • pp.227-241
    • /
    • 2021
  • Object detection techniques based on deep learning such as YOLO have high detection performance and precision in a single channel video stream. In order to expand to multiple channel object detection in real-time, however, high-performance hardware is required. In this paper, we propose a novel back-end server framework, a real-time AI vision platform (RAVIP), which can extend the object detection function from single channel to simultaneous multi-channels, which can work well even in low-end server hardware. RAVIP assembles appropriate component modules from the RODEM (real-time object detection module) Base to create per-channel instances for each channel, enabling efficient parallelization of object detection instances on limited hardware resources through continuous monitoring with respect to resource utilization. Through practical experiments, RAVIP shows that it is possible to optimize CPU, GPU, and memory utilization while performing object detection service in a multi-channel situation. In addition, it has been proven that RAVIP can provide object detection services with 25 FPS for all 16 channels at the same time.

Numerical Switching Performances of Cumulative Sum Chart for Dispersion Matrix

  • Chang, Duk-Joon
    • 통합자연과학논문집
    • /
    • 제12권3호
    • /
    • pp.78-84
    • /
    • 2019
  • In many cases, the quality of a product is determined by several correlated quality variables. Control charts have been used for a long time widely to control the production process and to quickly detect the assignable causes that may produce any deterioration in the quality of a product. Numerical switching performances of multivariate cumulative sum control chart for simultaneous monitoring all components in the dispersion matrix ${\Sigma}$ under multivariate normal process $N_p({\underline{\mu}},{\Sigma})$ are considered. Numerical performances were evaluated for various shifts of the values of variances and/or correlation coefficients in ${\Sigma}$. Our computational results show that if one wants to quick detect the small shifts in a process, CUSUM control chart with small reference value k is more efficient than large k in terms of average run length (ARL), average time to signal (ATS), average number of switches (ANSW).

Automatic wall slant angle map generation using 3D point clouds

  • Kim, Jeongyun;Yun, Seungsang;Jung, Minwoo;Kim, Ayoung;Cho, Younggun
    • ETRI Journal
    • /
    • 제43권4호
    • /
    • pp.594-602
    • /
    • 2021
  • Recently, quantitative and repetitive inspections of the old urban area were conducted because many structures exceed their designed lifetime. The health of a building can be validated from the condition of the outer wall, while the slant angle of the wall widely serves as an indicator of urban regeneration projects. Mostly, the inspector directly measures the inclination of the wall or partially uses 3D point measurements using a static light detection and ranging (LiDAR). These approaches are costly, time-consuming, and only limited space can be measured. Therefore, we propose a mobile mapping system and automatic slant map generation algorithm, configured to capture urban environments online. Additionally, we use the LiDAR-inertial mapping algorithm to construct raw point clouds with gravity information. The proposed method extracts walls from raw point clouds and measures the slant angle of walls accurately. The generated slant angle map is evaluated in indoor and outdoor environments, and the accuracy is compared with real tiltmeter measurements.

Simultaneous determination of corticosteroids in a herbal medicinal preparation by GC-MS

  • Jeong, Jae-Chul;Kim, Jin;Kim, Mee-Jung;Choi, Don-Woong;Chang, Seung-Yeup;Im, Moon-Kyo;Paeng, Ki-Jung
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2002년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2
    • /
    • pp.395.2-395.2
    • /
    • 2002
  • The determination method for 11 corticosteroids (betamethasone, cortisol. cortisone, cortisone acetate. dexamethasone. cortisol acetate, isoflupredone acetate, methylprednisolone. prednisone, prednisolone, and triamcinolone acetonide) in a herbal medicinal preparation (Sibjeondaibotang) by a gas chromatography-mass spectrometric (GC-MS) method with selected ion monitoring (SIM) mode is described. Samples (4 mL) were extracted by liquid-liquid extraction with diethyl ether. (omitted)

  • PDF

The Role of Sphingolipids Cycle in Hydrogen Peroxide-Induced Apoptosis in HL-60 Cells

  • Son , Jung-Hyun;Lee, Jae-Ick;Yang , Ryung;Kim, Dong-Hyun
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.2-2
    • /
    • pp.213.1-213.1
    • /
    • 2003
  • Sphingolipids and their metabolites are highly bioactive molecules that affect various cellular functions including differentiation, cellular senescence, apoptosis, and proliferation when added exogenously, or elevated intracellularly by turnover of complex sphingolipids or synthesis from de novo pathway. We are investigating the relationship of sphingolipids cycle in apoptosis early events. A new column liquid chromatography- tandem mass spectrometry (LC/MS/MS) in combination with multiple reaction monitoring (MRM) method was developed for the rapid, simultaneous and quantitative determination of unambiguous detecting sphingolipids in cells. (omitted)

  • PDF

Quantification of Three Prohibited Anabolic-Androgenic Steroids in Equine Urine using Gas Chromatography-Tandem Mass Spectrometry

  • Young Beom Kwak;Shaheed Ur Rehman;Hye Hyun, Yoo
    • Mass Spectrometry Letters
    • /
    • 제14권3호
    • /
    • pp.104-109
    • /
    • 2023
  • Anabolic-androgenic steroids (AAS) are used illegally to enhance muscle development and increase strength and power. In this study, a reliable, and sensitive quantitative method was developed and validated using heptafluorobutyric acid anhydride (HFPA) derivatives for the simultaneous detection of prohibited AAS (testosterone [TS], boldenone [BD], 5α-estrane-3β,17α-diol [EAD]) using gas chromatography-tandem mass spectrometry (GC-MS/MS). For processing the samples, solid phase extraction, methanolic hydrolysis, and liquid-liquid extraction were used. For detection using mass spectrometry, the multiple reaction monitoring (MRM) mode was used with the electron ionization (EI) positive mode. The method was evaluated for selectivity, linearity, lower limit of quantification, intra- and inter-day precision, accuracy, and stability. The results showed that the method was accurate and reproducible for the quantitation of the three steroids. The developed method was finally applied to the analysis of a suspect gelding urine sample received from the Asian Quality Assurance Program (AQAP).

Simultaneous Determination of Triterpenoid Saponins from Pulsatilla koreana using High Performance Liquid Chromatography Coupled with a Charged Aerosol Detector (HPLC-CAD)

  • Yeom, Hye-Sun;Suh, Joon-Hyuk;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권5호
    • /
    • pp.1159-1164
    • /
    • 2010
  • Several triterpenoid saponins from root of Pulsatilla koreana Nakai (Ranunculaceae) were studied and their biological activities were reported. It is difficult to analyze triterpenoid saponins using HPLC-UV due to the lack of chromophores. So, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we developed and validated a novel method of high performance liquid chromatography coupled with a charged aerosol detector for the simultaneous determination of four triterpenoid saponins: pulsatilloside E, pulsatilla saponin H, anemoside B4 and cussosaponin C. Analytes were separated by the Supelco Ascentis$^{(R)}$ Express C18 column (4.6 mm ${\times}$ 150 mm, 2.7 ${\mu}m$) with gradient elution of methanol and water at a flow rate of 0.8 mL/min at $30^{\circ}C$. We examined various factors that could affect the sensitivity of the detectors, including various concentrations of additives, the pH of the mobile phase, and the CAD range. Linear calibration curves were obtained within the concentration ranges of 2 - 200 ${\mu}g$/mL for pulsatilloside E, anemoside $B_4$ and cussosaponin C, and 5 - 500 ${\mu}g$/mL for pulsatilla saponin H with correlation coefficient ($R^2$) greater than 0.995. The limit of detection (LOD) and quantification (LOQ) were 0.04 - 0.2 and 2 - 5 ${\mu}g$/mL, respectively. The validity of the developed HPLC-CAD method was confirmed by satisfactory values of linearity, intra- and inter-day accuracy and precision. This method could be successfully applied to quality evaluation, quality control and monitoring of Pulsatilla koreana.

Detection and Quantitation of Residual Antibiotics and Antibacterial Agents in Foods

  • Ryu, Jae-Chun;Seo, Ja-Won;Song, Yun-Seon;Park, Jong-Sei
    • 한국식품위생안전성학회지
    • /
    • 제5권3호
    • /
    • pp.159-164
    • /
    • 1990
  • To detect and quantitation residual antibiotics and antibacterial agents in meats, we performed a biological assay employing the three microorganisms Bacillus subtilis ATCC 6633, Micrococcus luteus ATCC 9341, and Bacillus cereus var. mycoides ATCC 11778 for the screening purpose and developed a Gas Chromatography-mass Spectrometry(GC/MS) analysis for the confirmation and quantiation. In the biological assay (paper disk method), three test solution are used depending on the character of the residual antibiotics and antibacterial agents, follow by a simple clean up procedure which includes homogenization with Mcilvaine buffer, defatting with includes homogenization with Mcilvaine buffer, defatting with hexane, extraction with chloroform, clean-up by Sep-Pak $C_{18}$ and Bakerbond SPE carboxylic acid column. The chloroform layer is used for the analysis of sulfa agents. macrolides antibiotics and antibacterial agents, Adsorbed materials in the Sep-Pak $C_{18}$ were also employed for th analysis of penicillins and tetracyclines. Effluents from the Sep-Pak $C_{18}$ were cleaned-up one more by Bakerbond 10 SPE COOH column and employed for the analysis of aminoglycosides. In the instrumental analysis by using the GC/MSD, residual antibiotics and antibacterial agent were quantitated by selected ion monitoring (SIM) mode after derivatization. A simultaneous analysis of six residual antibiotic and antibacterial agent such as oxytetracycline, penicillin, ampicillin, choliraphenicol and thiamphenicol was developed with simple cleanup procedures revealing good recovery and reproducibility. Also, simultaneous detection of macrolides antibiotics such as erythromycin, spiramycin, and oleandomycin was developed after acid hydrolysis due to their large molecular structures. Because of the high reproducibility and selectivity of these two methods, it is very desirable that the combination of the two methods be used in the bioassay for the screening of residual antibiotics and antibacterial agent and that GC/MSD analysis be used for the confirmation and quantitation.

  • PDF