• Title/Summary/Keyword: simultaneous measurement

Search Result 484, Processing Time 0.025 seconds

Relationship between Immunoglobulin E, Eosinophil Count and Allergens in Allergic Patients (알레르기 환자에서 Immunoglobulin E와 Eosinophil count 및 Allergen과의 관련성)

  • Yoon, In-Sook;Kwon, Se-Young
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.236-246
    • /
    • 2009
  • As the allergic diseases in patients are increasing, it is important to find out the allergens. A multiple antigen simultaneous test(MAST) is a simple method for in vitro measurement of allergen-specific IgE antibodies. This study was performed to evaluate the relationship between allergen-specific IgE antibodies, serum total IgE and peripheral eosinophil count in the allergic patients. According to the results of the study, the total IgE positive rate(above class 2) from the inhalent is 96.97%, and that from food panel is 98.06%. The research showed that the positive rate of the allergen-specific IgE was House dust 51.52%, D. farinae 45.46%, Cat 31.99% in inhalent panel, and 55.34%, 42.72%, 34.96% in food panel. Serum total IgE was associated with allergy, however, allergy was not always associated with eosinophilia.

The Effect of Proprioceptive Neuromuscular Facilitation and Traditional Trunk Stabilization Training on the Rectus Abdominis Muscle Contraction (고유수용성신경근촉진 기법을 이용한 체간부 안정화 운동이 복직근 수축력에 미치는 효과)

  • Lee, Nam-Yong;Kim, Su-Hyon;Kim, Tae-Youl
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • Purpose : The purpose of this study was to study the effect of rectus abdominal muscle contraction by proprioceptive neuromuscular facilitation trunk stabilization training using extremity simultaneous pattern (PNF trunk stabilization training) and traditional trunk stabilization training methods. Methods : A group of 24 adults male and female, healthy, with no previous medical history nor disability in neuromuscular system and musculoskeletal system was chosen as subjects, and was divided into a control group, a PNF trunk stabilization training group and a traditional trunk stabilization training group. Experiments were performed on the last two groups, 3 times a week for 6 weeks, totaling 18 times. Using a dynamometer, muscle strength and endurance time on trunk flexion were measured before and after each experiment, and surface electromyography in left and right rectus abdominis were measured. Results : following results were obtained; 1. As for the change in the maximal voluntary isometric contraction (MVIC), all subjects in the trunk stabilization training group showed significant difference from those in the control group. 2. As for surface electromyography measurement and the changes in root mean square at the time of trunk flexion, in the left rectus abdominis, PNF trunk stabilization training group showed significant difference from the control group, while in the right rectus abdominis, traditional trunk stabilization training group showed significant difference. Conclusion : To sum up the results, both trunk stabilization training groups showed improvement in the MVIC of abdominal muscle, motor unit action potential activity, but the difference between two trunk stabilization training groups was not significant. Therefore, while trunk stabilization training significantly improved abdominal muscle contraction, but the difference attributable to training methods was found to be insignificant.

Simultaneous Measurement of Thickness and Refractive Index of Transparent Material Using a Collimated Beam Having a Finite Radius (유한 반경의 시준 광속을 이용한 투명 매질의 두께와 굴절률의 동시 측정)

  • Park, Dae-Seo;O, Beom-Hoan;Park, Se-Geun;Lee, El-Hang;Lee, Seung-Gol
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.1
    • /
    • pp.29-33
    • /
    • 2009
  • We propose a new measuring technique based on optical low-coherence reflectometry that enables us to determine the refractive index and the geometrical thickness of a transparent sample by one-time scanning only. By passing a collimated beam having a finite size through the edge of the sample, the refractive index and the geometrical thickness can be determined simultaneously from the comparison of interferograms generated by two kinds of reflected beams. In this study, a refractive index could be determined with the accuracy of $10^{-3}$, and its accuracy would be enhanced by using a more precise translator and a thicker sample.

Recognition of a Housewife for Rearing-related Supports of a Husband and its Relationship with Mental Health -Comparison between Korea and Japan - (남편의 육아지원에 대한 부인의 인지와 정신적 건강과의 관련성 - 한국과 일본의 비교 -)

  • Park, Chun-Man;Okada, Setsuko
    • Korean Journal of Health Education and Promotion
    • /
    • v.24 no.4
    • /
    • pp.161-179
    • /
    • 2007
  • To commonly apply the ${\ulcorner}$Measurement parameter for housewives for rearing-related supports of a husband${\lrcorner}$ in Korea and Japan, the current study conducted to confirm the relationship between recognition of a housewife for rearing-related supports of a husband and mental health after reviewing the appropriateness of the parameter. For the statistical analysis, 829 married Korean women in D city and 1,302 Japanese women in S city having children before entering a school were subjected for the study. For reviewing the appropriateness of the parameter, the simultaneous factor analysis that adopted the structural equation modeling was used. As the result of the analysis, 10 categories of factor structural model comprising the ${\ulcorner}$Recognition of a housewife for rearing-related supports of a husband${\lrcorner}$ resulted with the secondary model which sets of ${\ulcorner}$Recognition for emotional support${\lrcorner}$, ${\ulcorner}$Recognition for instrumental support${\lrcorner}$ and ${\ulcorner}$Recognition for information support${\lrcorner}$ as the primary factor and ${\ulcorner}$Recognition of a housewife for rearing-related supports of a husband${\lrcorner}$ as the secondary factor, and the model was found to be appropriate for the data in Korea and Japan. The result is considered to prove the constructs validity of ${\ulcorner}$Recognition of a housewife for rearing-related supports of a husband${\lrcorner}$ parameter. In addition, the relationship between ${\ulcorner}$Recognition of a housewife for rearing-related supports of a husband${\lrcorner}$ and mental health(GHQ) was reviewed by using multiple indicator model, and found the similarity of Korean and Japanese data. The scores measured by using the above parameter resulted to show high relationship with educational level of housewife, family configuration, and number of children.

Development of Ultrasonic Sensors for Simultaneous Measurement of Longitudinal and Shear Waves (종-횡파 동시 측정용 초음파 센서의 개발)

  • Kim, Yeon-Bo;Rho, Yong-Rae
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 1999
  • A study has been made on the fabrication of a dual mode(a longitudinal and shear mode) ultrasonic sensor using a single PZT piezoelectric ceramic element. We investigated the mechanism of the dual mode sensor that generated both of the longitudinal and the shear waves simultaneously with the single PZT element. Through the analysis of analytic wave propagation equations, all the possible crystal cuts have been examined to determine appropriate Euler transformation angles for efficient excitations of the dual modes. We studied the performance of a PZT element as a function of its rotation angle so that its efficiency is optimized to excite the two waves of equal strength. Experimental examination of the waveform on a delay line(STS303) setup confirms that the ultrasonic sensor can transmit and detect both longitudinal and shear waves simultaneously.

  • PDF

Analysis of Natural Ventilation Characteristics of Venlo-type Greenhouse with Continuous Roof Vents (연속형 천창을 가진 벤로형 온실의 자연환기 특성 분석)

  • Kwon, Jin-Kyeong;Lee, Sung-Hyun;Seong, Jae-Hoon;Moon, Jong-Pil;Lee, Soo-Jang;Choi, Byeong-Min;Kim, Kyeong-Ja
    • Journal of Biosystems Engineering
    • /
    • v.36 no.6
    • /
    • pp.444-452
    • /
    • 2011
  • In this study the characteristics of natural ventilation of Venlo-type greenhouse with continuous roof vents were analyzed using commercial computational fluid dynamics (CFD) code. Developed CFD simulation model was verified by comparison with experimental data. Simulation errors were 1.9-46.0% for air velocity and 1.7-11.2% for air temperature at each measurement point. CFD simulations were conducted to estimate the effect of roof vents opening direction, opening angle, outside wind velocity and wind directions on ventilation rate and climate condition in greenhouse. The results of this study showed that ventilation rate of the present greenhouse was increased linearly in proportion to the increase of roof vent opening angle and outside wind velocity over 2.0 m/s. According to the analysis on the effects of different roof vent opening direction, simultaneous opening of wind and leeward vents showed the highest ventilation rate and lowest mean temperature in greenhouse.

A Study on the Mechanism of Urinary and Biliary Excretion of Chloramphenicol in the Dog (개에 있어서 Chloramphenicol의 뇨(尿) 및 담즙중(膽汁中) 배설기전(排泄機轉)에 관(關)한 연구(硏究))

  • Kim, Sung-Won
    • Journal of Pharmaceutical Investigation
    • /
    • v.7 no.1_4
    • /
    • pp.38-50
    • /
    • 1977
  • A study on the mechanism of biliary and urinary excretion of chloramphenicol has been performed in the dog. 1) Chloramphenicol administered intravenously to dogs with ligated renal pedicle, readily appeared in bile greater than in plasma. 6.9% of a 50mg /kg i. v. dose of chloramphenicol were excreted into bile within 100 minutes. During the same periods of above experiment, the bile/plasma concentration ratios(B/P ratios) were 46 to 87. 2) Chloramphenicol injected into the vein of dog was rapidly excreted into urine. 18% of the administered dose were excreted into urine within 70 minutes. In the same periods of this experiment, Ccm/Ccr ratios were greater than 1.0 in most cases. 3) In experiment of simultaneous measurement of biliary and urinary excretion of chloramphenicol, Ccm/Ccr ratios were less than 1.0 and B/P ratios were 50 to 52. 4) In experiment measured simultaneously biliary and urinary excretion both Ccm/Ccr and $C^Hcm$(hepatic clearance) were significantly declined by probenecid, but not affected by 2,4-DNP and aminophylline although 2,4-DNP increased only bile flow and aminophylline both bile and urine volume. 5) Ccm/Ccr and $C^Hcm$ were increased in proportion to increment of plasma concentration ranging from 3.3 to 30 mg% of chloramphenicol. But when plasma concentration were increased to 70mg %, Ccm/Ccr were not increased and $C_Hcm$ were reduced about 30% in comparison with values obtajned at 30mg% of chloramphenicol. 6) Free/Bound(free to bouid from) ratios ranging from 1.0 to 90.0mg% of chloramphenicol were 76.2+3.72% $(mean{\pm}S.E.)$ Above results suggest that chloramphenicol is excreted into bile by a process of active trasport, that excretion of chloramphenicol into urine was made up with dual process, reabsorption and secretion, and that renal secretion was attained by active trasport process although renal reabsorption process could not understand.

  • PDF

A Study on an Implementation of Control Panel of Sun Trackers and Monitoring System for Photovoltaic Generation Plants (태양광발전의 태양추적기제어반 및 모니터링시스템 구현에 관한 연구)

  • Lho, Tae-Jung;Park, Min-Yong;Lee, Seung-Hyeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3161-3167
    • /
    • 2010
  • Hall sensors of BLDC(brushless DC) motor are used to detect a position information for a control mechanism, which implements an algorithm for velocity and position control. Actual azimuth and altitude were measured to evaluate a control precision. The measurement revealed comparatively good accuracy that the measured values were $2.02^{\circ}$ and $1.01^{\circ}$ respectively, and the maximum error falls within $1.86^{\circ}$. The developed monitoring system of photovoltaic generation plants is a LCU(Local Control Unit) based on an integrated monitoring system which supports 1:N method for multiple simultaneous connections, remote control and real-time system state monitoring.

Compensation of Peak Expiratory Air Flow Rate Considering Initial Slope in Velocity Type Air Flow Transducer (속도계측형 호흡기류센서에서 상승시간을 고려한 최고호기유량의 교정 기법)

  • Cha, Eun-Jong;Lee, In-Kwang;Kim, Seong-Sik;Kim, Wan-Suk;Park, Kyung-Soon;Kim, Wun-Jae;Kim, Kyung-Ah
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.867-872
    • /
    • 2009
  • Peak expiratory flow rate(PEF) is one of the most important diagnostic parameters in spirometry. PEF occurs in a very short duration during the forced expiratory maneuver, which could lead to measurement error due to non-ideal dynamic characteristic of the transducer. In such case the initial slope of the flow rate signal determines the accuracy of the measured PEF. The present study considered this initial slope as a parameter to compensate PEF. The 26 standard flow rate signals recommended by the American Thoracic Society(ATS) were flown through the air flow transducer followed by simultaneous measurements of PEF and maximum transducer output$(N_{PEF})$. $N_{PEF}$-PEF satisfied a quadratic equation in general, however, two signals (ATS #2 and #26) having large initial slopes deviated from the fitting equation to a significant degree. The relative error was found to be in a linear relationship with the initial slope, thus, $N_{PEF}$ was appropriately compensated to provide accurate PEF with mean relative error less than only 1%. The 99% confidence interval of the mean relative error was less than a half of the error limit of 5% recommended by ATS. Therefore, PEF can be very accurately determined by compensating the transducer output based on the initial slope, which should be a useful technique for air flow transducer calibration.

Emission Characteristics of Elemental Constituents in Fine Particulate Matter Using a Semi-continuous Measurement System (준 실시간 측정시스템을 이용한 미세입자 원소성분 배출특성 조사)

  • Park, Seung-Shik;Ondov, John M.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.26 no.2
    • /
    • pp.190-201
    • /
    • 2010
  • Fine particulate matter < $1.8{\mu}m$ was collected as a slurry using the Semicontinuous Elements in Aerosol Sampler with time resolution of 30-min between May 23 and 27, 2002 at the Sydney Supersite, Florida, USA. Concentrations of 11 elements, i.e., Al, As, Cd, Cr, Cu, Fe, Mn, Ni, Pb, Se, and Zn, in the collected slurry samples were determined off-line by simultaneous multi-element graphite furnace atomic absorption spectrometry. Temporal profiles of $SO_2$ and elemental concentrations combined with meteorological parameters such as wind direction and wind speed indicate that some transient events in their concentrations are highly correlated with the periods when the plume from an animal feed supplement processing facility influenced the Sydney sampling site. The peaking concentrations of the elemental species during the transient events varied clearly as the plume intensity varied, but the relative concentrations for As, Cr, Pb, and Zn with respect to Cd showed almost consistent values. During the transient events, metal concentrations increased by factors of >10~100 due to the influence of consistent plumes from an individual stationary source. Also the multi-variate air dispersion receptor model, which was previously developed by Park et al. (2005), was applied to ambient $SO_2$ and 8 elements (Al, As, Cd, Cr, Cu, Fe, Pb, and Zn) measurements between 20:00 May 23 and 09:30 May 24 when winds blew from between 70 and $85^{\circ}$, in which animal feed processing plant is situated, to determine emission and ambient source contributions rates of $SO_2$ and elements from one animal feed processing plant. Agreement between observed and predicted $SO_2$ concentrations was excellent (R of 0.99; and their ratio, $1.09{\pm}0.35$) when one emission source was used in the model. Average ratios of observed and predicted concentrations for As, Cd, Cr, Pb, and Zn varied from $0.83{\pm}0.26$ for Pb to $1.12{\pm}0.53$ for Cd.