• Title/Summary/Keyword: simultaneous analytical methods

Search Result 99, Processing Time 0.024 seconds

Method development and validation of spectrophotometric and RP-HPLC methods for simultaneous estimation of spironolactone and furosemide in bulk and combined tablet dosage forms

  • Chavan, Rohankumar R.;Bhinge, Somnath D.;Bhutkar, Mangesh A.;Randive, Dheeraj S.;Salunkhe, Vijay R.
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.212-224
    • /
    • 2021
  • The intent of the present work was to develop a simple, sensitive, accurate, precise, rapid and economical UV- spectrophotometric and reverse phase high pressure liquid chromatographic method for the simultaneous estimation of Spironolactone and Furosemide in bulk and combined tablet dosage forms. UV-Spectrophotometry was carried out by simultaneous equation method using 0.02 M potassium dihydrogen phosphate buffer pH 3.5: Acetonitrile (50:50) v/v as a solvent. The linearity range was 2-14 ㎍ mL-1 for Spironolactone and Furosemide with a correlation coefficient > 0.99. The chromatographic separation was achieved on 250 mm × 4.6 mm, hypersil BDS C18 column with particle size 5 ㎛, by using an isocratic mixture of 0.02 M potassium dihydrogen phosphate buffer pH 3.5: Acetonitrile: tert butyl methyl ether (49:50:1) v/v/v as a solvent at a flow rate of 1 mL min-1 and UV detection was carried out at 254 nm. The retention time were observed to be 3.666 and 6.661 minutes for Furosemide and Spironolactone respectively. The two developed methods were validated according to the ICH guidelines for accuracy, precision, linearity, LOD, LOQ and were found to be within the limits. It can be concluded that these two methods could be successfully used for the simultaneous estimation of Spironolactone and Furosemide in bulk and combined tablet dosage forms.

Simultaneous Determination of 80 Unapproved Compounds using HPLC and LC-MS/MS in Dietary Supplements

  • Kwon, Jeongeun;Shin, Dasom;Kang, Hui-Seung;Suh, Junghyuck;Lee, Gunyoung;Lee, Eunju
    • Mass Spectrometry Letters
    • /
    • v.13 no.3
    • /
    • pp.58-83
    • /
    • 2022
  • We developed analytical methods using high performance chromatography (HPLC) and liquid chromatography tandem mass spectrometry (LC-MS/MS) for the simultaneous determination of 80 unapproved compounds in dietary supplements. The target compounds for analysis were unapproved ingredients (e.g., pharmaceuticals) that have potential adverse effects on consumers owing to accidental misuse, overuse, and interaction with other medication in dietary supplement. Two analytical methods were tested to identify the optimal validation results according to AOAC guideline. As a result, limit of quantification (LOQ) was 0.14-0.5 ㎍ mL-1; linearity (r2) was ≥ 0.99; accuracy (expressed as recovery) was 78.9-114%; precision (relative standard deviation) was ≤ 4.28% in the HPLC method. In the LC-MS/MS method, LOQ was 0.01-2 ng mL-1, linearity (r2) was ≥0.98, accuracy was 71.7-119%; precision was ≤ 12.5%. The developed methods were applied to 51 dietary supplements collected from 2019 to 2021 through MFDS alert system. Based on our previous monitoring study, major compounds were icariin, sibutramine, yohimbine, sildenafil, tadalafil, sennosides (A, B), cascarosides (A, B, C, D), and phenolphthalein. In this study, we re-analyzed samples of detected compounds, and evaluated the statistical difference using Bland-Altman analysis to compare two analytical approaches between HPLC and LC-MS/MS. These results showed a good agreement between two methods that can be used to monitor the unapproved ingredients in dietary supplements. The developed two methods are complementarily suitable for monitoring the adulteration of 80 unapproved compounds in dietary supplements.

Establishment of analytical methods for allergenic compounds in mouthwashes and sanitary napkins by ultra-high-performance liquid chromatography with tandem mass spectrometry

  • Hee-Jung Sim;Hee-Jin Jeong;Yeong-In Lee;Yu-Jin Cho;Seung-Hoon Baek;Jong-Hwan Kim
    • Analytical Science and Technology
    • /
    • v.36 no.2
    • /
    • pp.89-98
    • /
    • 2023
  • Analytical methods for detecting atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes were developed using ultrahigh performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). UHPLC-MS/MS conditions were optimized for rapid, sensitive, and simultaneous analysis of the five allergenic compounds. The methods were validated by assessing their specificity, matrix effects, limit of detection (LOD), limit of quantification (LOQ), linearity, accuracy, and precision. Good linearity was achieved with a determination coefficient of ≥0.99. The LOD and LOQ were 2.1-9.8 and 6.4-29.6 ng/g for sanitary napkins and 0.29-0.48 and 0.87-1.45 ng/mL for mouthwashes, respectively. The accuracy and precision were within an acceptable range according to the criteria reported in the European SANTE/11813/2017 guidelines (70-120 % recovery, <20 % relative standard deviation). Therefore, these methods can be used to analyze atranol, chloroatranol, evernic acid, (+)-usnic acid, and atranorin in sanitary napkins and mouthwashes.

Development and Validation of the Simultaneous Analytical Method of Urinary Metals and Metalloids for the National Biomonitoring Programs (국가 바이오모니터링 프로그램을 위한 소변 중 금속류 동시분석법 개발 및 검증)

  • Cho, Yong Min;Yang, Minho;Im, Hosub;Cha, Sangwon;Lee, Jaeick;Kim, Ki Hun;Han, Sang Beom
    • Journal of Environmental Health Sciences
    • /
    • v.45 no.6
    • /
    • pp.594-604
    • /
    • 2019
  • Objectives: This study developed and validated an analysis method of urinary metals and metalloids that can be applied inductively with coupled plasma mass spectrometry (ICP-MS). Methods: 0.3 mL of urine was used to analyze 25 metal and metalloid compounds using ICP-MS. The validation of the analytical method included linearity, accuracy, precision, and the calculation of detection limits. In addition, a comparison test was performed with the graphite furnace atomic absorption spectrometry (GF-AAS) method, which is the current standard method, with urine samples of 66 healthy subjects. Results: The linearities (R2) of calibration curves of all 25 compounds were ≥ 0.999. Of the 25 compounds, the intra-day and inter-day accuracy% of 17 and 20 met ≤15%, respectively. In addition, fifteen compounds showed ≤15% recovery% for certificated reference materials. Intraclass correlation coefficients of the comparison between the current methods and new methods in this study were 0.952 (p-value<0.001) and 0.911 (p-value<0.001) for urinary cadmium and mercury, respectively. Conclusion: This study proposes an efficient simultaneous methodology that can analyze multi elements in smaller sample amounts. More reproduction experiments are needed in the future.

Comparison of Analytical Methods for Volatile Flavor Compounds in Leaf of Perilla frutescens

  • Kim, Kwan-Su;Ryu, Su-Noh;Song, Ji-Sook;Bang, Jin-Ki;Lee, Bong-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.44 no.2
    • /
    • pp.154-158
    • /
    • 1999
  • Volatile flavor compounds from perilla leaves were extracted and analyzed with different methods, head-space analysis (HS), simultaneous steam distillation and extraction (SDE) , and solvent extraction (SE), and to compare their efficiencies for quick analysis. Over 30 volatile compounds were isolated and 28 compounds were identified by GC/MSD. Major compound was perillaketone showing the compositions of which were 92% in SDE method, 86% in headspace analysis, and 62% in solvent extraction method. For quick evaluation of leaf flavor in perilla, it was desirable because the headspace analysis method had a shorter analyzing time and smaller sample amount than the other methods.

  • PDF

Analytical Evaluation of the Surface Integral in the Singularity Methods

  • Suh, Jung-Chun
    • Selected Papers of The Society of Naval Architects of Korea
    • /
    • v.2 no.1
    • /
    • pp.1-17
    • /
    • 1994
  • For a planar curve-sided panel with constant or linear density distributions of source or doublet in the singularity methods, Cantaloube and Rehbach show that the surface integral can be transformed into contour integral by using Stokes'formulas. As an extension of their formulations, this paper deals with a planar polygonal panel for which we derive the closed-forms of the potentials and the velocities induced by the singularity distributions. Test calculations show that the analytical evaluation of the closed-forms is superior to numerical integration (suggested by Cantaloube and Rehbach) of the contour integral. The compact and explicit expressions may produce accurate values of matrix elements of simultaneous linear equations in the singularity methods with much reduced computer time.

  • PDF

Simultaneous Determination of Abamectin and Milbemectin Residues in Fruits

  • Lee, Young-Deuk;Kwon, Chan-Hyeok
    • Journal of Applied Biological Chemistry
    • /
    • v.43 no.2
    • /
    • pp.94-100
    • /
    • 2000
  • An analytical method was developed to determine abamectin and milbemectin residues in apple, pear, and citrus using HPLC with ultraviolet absorption detection. Abamectin and milbemectin were extracted with methanol from apple, pear, and citrus samples. The extract was diluted with saline water and dichloromethane partition was followed to recover the compounds from the aqueous phase. Florisil column chromatography and aminopropyl solid-phase extraction were employed as cleanup methods to remove most of co-extractives from the sample extract. Reverse-phase HPLC using an octadecylsilyl column was successfully applied to separate and quantitate abamectin and milbemectin residues in sample extracts at the wavelength of 245 nm. Recoveries of abamectin and milbemectin from fortified samples ranged 80.4~90.3% and 90.9~96.8%, respectively. Relative standard deviations of the analytical method were less than 10% for both acaricides. Detection limit of the analytical method was 0.003 mg/kg sample for all the analytes. The proposed method was reproducible and sensitive enough to evaluate terminal residues of abamectin and milbemectin in apple, pear, and citrus.

  • PDF

Simultaneous Analysis of Pesticide Priority Pollutants in Soil (토양 중의 Pesticide Priority Pollutants 동시 분석에 관한 연구)

  • Lee, Seung-Seok;Park, Young-Joo;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.8 no.3
    • /
    • pp.237-248
    • /
    • 1995
  • The simultaneous analysis of 16 organic pesticides, which are listed as a part of 129 priority pollutants by EPA(Environmental Protection Agency), was performed by GC-ECD(electron capture detector) and GC/MS-SIM(selected ion monitoring). Two extraction procedures from SW-846, sonication extraction and Soxhlet extraction, were somewhat modified and compared as an extraction and concentration method for the analysis of priority pollutants in soil. Accuracy and precision of the methods were reported from the calculation of mean recovery, mean relative standard deviation, and method detection limit.

  • PDF

Optimization of an extraction method for the simultaneous quantification of six active compounds in the aril part of Orostachys japonicus using HPLC-UV

  • Gao, Dan;Kim, Jin Hyeok;Cho, Chong Woon;Yang, Seo Young;Kim, Young Ho;Kim, Hyung Min;Kang, Jong Seong
    • Analytical Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.153-159
    • /
    • 2021
  • In this study, we describe the development of a new high-performance liquid chromatography (HPLC) method for the simultaneous analysis of six bioactive compounds (including gallic acid, epicatechin 3-gallate, quercitrin, afzelin, quercetin, and kaempferol) from Orostachys japonicus. The extraction method was investigated and optimization of the extraction time (min), solvent composition (%), and solvent to material ratio were conducted. As a result, 30 min extraction with 50% methanol and 40:1 mL/g of solvent: material ratio achieved the highest extraction efficiency with a yield of 3.32 mg/g. Furthermore, the developed HPLC method was validated and the correlation coefficient (R) values were within the satisfactory range of 0.9995-0.9999 over the linearity range of 1.53-417 ㎍/mL. The limit of detection and limit of quantification for the six active components were between 0.03-0.08 ㎍/mL and 0.08-0.26 ㎍/mL, respectively. With these newly optimized and developed methods, four batches of O. japonicus were analyzed to confirm the high extraction efficiency of the method and the feasibility of an application.

Development of HPLC method for differentiation of three parts of mulberry tree

  • Eom, Ji Hyun;Vu, Thi Phuong Duyen;Cai, Linxi;Zhao, Yan;Li, Hong Xu;Yang, Seo Young;Kim, Young Ho;Kim, Seok Jin;Cho, Hyun So;Bao, Haiying;Chem, Jianbo;Kim, Kyung Tae;Kang, Jong Seong
    • Analytical Science and Technology
    • /
    • v.30 no.3
    • /
    • pp.130-137
    • /
    • 2017
  • The leaves (Mori Folium; MF), branches (Mori Ramulus; MR), and root bark (Mori Cortex Radicis; MCR) of the mulberry tree have been used as therapeutic herbs for centuries. Existing analytical methods were developed specifically for different parts of the tree and cannot be applied to samples containing a mixture of tree parts. Such method specialization is time-consuming and requires separate identification and quality control of each tree part. This report describes an HPLC method for the simultaneous quality control and discrimination of MF, MR, and MCR using four marker compounds: rutin, kuwanon G, oxyresveratrol, and morusin. An Optimapak $C_{18}$ column ($4.6{\times}250mm$, $5{\mu}m$) was used with a gradient elution of 0.1 % formic acid in water and acetonitrile. The flow rate was 1.0 mL/min and the detection wavelength was 270 nm. In quantitative analyses of the three parts, rutin (0.11 % w/w) was detected only in MF. The oxyresveratrol content (0.12 % w/w) was highest in MR. Kuwanon G (0.33 % w/w) and morusin (0.18 % w/w) were higher in MCR than in other parts. The HPLC method given herein can be used to simultaneously classify and quantify three herbal medicines from the mulberry tree.