• Title/Summary/Keyword: simplified model

Search Result 2,183, Processing Time 0.044 seconds

A Study on the Application of Simulation-based Simplified PMV Regression Model for Indoor Thermal Comfort Control (실내 온열환경 쾌적 제어를 위한 단순 PMV 회귀모델의 적용에 관한 시뮬레이션 연구)

  • Kim, Sang-Hun;Yun, Sung-Jun;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.1
    • /
    • pp.69-77
    • /
    • 2015
  • The PMV regression analysis was conducted for this model based on a database of the PMV variables. PMV regression model simplification was completed through sensitivity and data analysis. The simplified PMV regression model's and Fanger PMV model was confirmed through MAE and RMSE. And the EMS in EnergyPlus was used to establish a simplified PMV regression analysis-based thermal comfort control. Also, the thermal comfort controls based on simplified PMV model and the Fanger PMV model were applied to the building model, it was confirmed that both controls met the thermal comfort range in more than 90% of cases during the air conditioning period.

Equivalent Circuit Modeling of Rosen-type Multilayer Piezoelectric Transformer (Rosen형 적층 압전변압기의 등가회로 모델링)

  • Shin, Hoon-Beom;Lee, Yong-Kuk;Yu, Young-Han;Ahn, Hyung-Keun;Han, Deuk-Young
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1099-1105
    • /
    • 2006
  • In this paper, the equivalent circuit model of a Rosen-type multilayer piezoelectric transformer(MPT) has been proposed based on the Mason's equivalent circuit model and the principle of single layer piezoelectric plate. From the piezoelectric direct and converse effects, the symbolic expressions between the electric inputs and outputs of the MPT have been derived from the equivalent circuit model. A simplified equivalent circuit model of the MPT whose driving part has a single input form has been proposed. The symbolic expressions of the driving part have been derived from the simplified equivalent circuit model and the model was compared with the multi-input equivalent circuit model through the simulation. In the comparisons between the simulation results and the experimental data, output voltage is 630 Vp-p in case of 11-layered MPT and 670 Vp-p for 13-layered MPT over the experiment range. As the load resistance increases, output voltage increases and saturates over $300k{\Omega}$ and the resonant frequency changes from 102 kHz to 103 kHz. The simulation and the experimental results agree well over different load resistances and frequencies.

Optimal output feedback design for discrete large scale systems with two time-scale separation properties

  • Jin, Jong-Sam;Kim, Soo-Joong
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1987.10b
    • /
    • pp.203-208
    • /
    • 1987
  • Design problem of output feedback controllers for discrete large scale systems using simplified model is investigated. It is shown that neglecting fast modes does not generally guarantee the stability of the closed loop system. In this paper, the design procedure is proposed to stabilize the system by minimizing a quadratic cost function for the simplified model and a measure of stability for the neglected fast model.

  • PDF

Analytical Model for the Calculations of Ultimate Moment Capacities of Double Angle Connections (더블앵글 접합부의 극한모멘트 산정을 위한 해석모델)

  • Yang, Jae-Geun;Lee, Gil-Young;Cho, Hye-Jung;Choun, Ji-Won
    • Proceeding of KASS Symposium
    • /
    • 2006.05a
    • /
    • pp.81-87
    • /
    • 2006
  • This study has been conducted to predict the ultimate moment capacities of double angle connections with various angle thicknesses and bolt gage distances. Considering the results of experimental tests conducted previously, a simplified analytical model is suggested in this research. In addition, some basic data are also provided for structural engineers to design a double angle connection preliminary.

  • PDF

A simplified method for estimating fundamental periods of pylons in overhead electricity transmission systems

  • Tian, Li;Gao, Guodong;Qu, Bing
    • Earthquakes and Structures
    • /
    • v.19 no.2
    • /
    • pp.119-128
    • /
    • 2020
  • In seismic design of a pylon supporting transmission lines in an overhead electricity transmission system, an estimation of the fundamental periods of the pylon in two orthogonal vertical planes is necessary to compute the seismic forces required for sizing pylon members and checking pylon deflections. In current practice, the fundamental periods of a pylon in two orthogonal vertical planes are typically obtained from eigenvalue analyses of a model consisting of the pylon of interest as well as some adjacent pylons and the transmission lines supported by these pylons. Such an approach is onerous and numerically inconvenient. This research focused on development of a simplified method to determine the fundamental periods of pylons. The simplified method is rooted in Rayleigh's quotient and is based on a single-pylon model. The force vectors that can be used to generate the shape vectors required in Rayleigh's quotient are presented in detail. Taking three pylons selected from representative overhead electricity transmission systems having different design parameters as examples, the fundamental periods of the chosen pylons predicted from the simplified method were compared with those from the rigorous eigenvalue analyses. Result comparisons show that the simplified method provides reasonable predictions and it can be used as a convenient surrogate for the tedious approach currently adopted.

Simplified Machine Diagnosis Techniques Using ARMA Model of Absolute Deterioration Factor with Weight

  • Takeyasu, Kazuhiro;Ishii, Yasuo
    • Industrial Engineering and Management Systems
    • /
    • v.8 no.4
    • /
    • pp.247-256
    • /
    • 2009
  • In mass production industries such as steel making that have large equipment, sudden stops of production process due to machine failure can cause severe problems. To prevent such situations, machine diagnosis techniques play important roles. Many methods have been developed focusing on this subject. In this paper, we propose a method for the early detection of the failure on rotating machine, which is the most common theme in the machine failure detection field. A simplified method of calculating autocorrelation function is introduced and is utilized for ARMA model identification. Furthermore, an absolute deterioration factor such as Bicoherence is introduced. Machine diagnosis can be executed by this simplified calculation method of system parameter distance with weight. Proposed method proved to be a practical index for machine diagnosis by numerical examples.

Accuracy of structural computation on simplified shape

  • Marin, P.
    • Structural Engineering and Mechanics
    • /
    • v.35 no.2
    • /
    • pp.127-140
    • /
    • 2010
  • This paper focuses on a number of criteria that enable controlling the influence of geometric simplification on the quality of finite element (FE) computations. To perform the mechanical simulation of a component, the corresponding geometric model typically needs to be simplified in accordance with hypotheses adopted regarding the component's mechanical behaviour. The method presented herein serves to compute an a posteriori indicator for the purpose of estimating the significance of each feature removal. This method can be used as part of an adaptive process of geometric simplification. If a shape detail removed during the shape simplification process proves to be influential on mechanical behaviour, the particular detail can then be reinserted into the simplified model, thus making it possible to readapt the initial simulation model. The fields of application for such a method are: static problems involving linear elastic behaviour, and linear thermal problems with stationary conduction.

Earthquake Response Analysis of a RC Bridge employing a Point Hinge Model (포인트 힌지 모델을 적용한 철근콘크리트 교량의 지진응답 해석)

  • 이도형;전종수;박대효
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.419-426
    • /
    • 2003
  • Simplified modeling approach for the seismic behavior of a reinforced concrete bridge is investigated in this paper. For this purpose, a hysteretic axial-flexure interaction model was developed and implemented into a nonlinear finite element analysis program. Thus, the seismic response of reinforced concrete bridge piers was evaluated by the simplified point hinge representations. Comparative studies for reinforced concrete bridge piers indicated that the analytical predictions obtained with the new formulations showed a good correlation with experimental results. In addition, seismic response analysis of a reinforced concrete bridge utilizing the simplified point hinge model revealed the adequacy and applicability of the present development.

  • PDF

The Study of Stiffness Evaluation Technique for L, T Shaped Joint Structures Using Normal Modes Analysis with Lumped Mass (모드해석을 이용한 L, T 자형 구조물의 결합 강성 평가 방법에 대한 연구)

  • Hur, Deog-Jae;Jung, Jae-Yup;Cho, Yeon;Park, Tae-Won
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.975-983
    • /
    • 1999
  • This paper describes the dynamic characteristics of the joint structures in case of using the simplified beam model in the F. E. analysis. The modeling errors, when replace the shell with the beam, are investigated through F. E. normal modes analysis. Normal mode analysis were performed to obtain the natural frequencies of the L and T shaped joints with various type of channels. The results were analyzed to access the effects of the models on the accuracy of F.E. analysis by identifying the geometric factors which cause the error. The geometric factors considered are joint angle, channel length, thickness and area ratio of the hollow section to the filled one. The joint stiffness evaluation technique is developed in this study using normal modes analysis with Lumped Mass. With this method, the progressively improved results of F. E. analysis are obtained using the simplified beam model. The static and normal modes analysis are performed with the joint stiffness values obtained by the Kazunori Shimonkakis' virtual stiffness method and the proposed method and these simplified modeling errors are compared.

  • PDF

Application of Simplified Daylight Prediction Method for Daylighting Performance Evaluation on Overcast Sky (실내 주광조도 간이 예측식을 활용한 담천공 시의 자연 채광 성능 평가)

  • Yoon, Kap-Chun;Yun, Su-In;Kim, Seong-Sik;Kim, Kang-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.1-9
    • /
    • 2014
  • Daylight is very useful to control the indoor environment, and can save energy in buildings. So it is necessary to evaluate the daylighting performance of buildings. We proposed a simplified equation that can be used in the early stages of design. And we verified the equation by using the measured illuminance data from the 1/5 scale model. We compared the calculated indoor illuminances and measured illuminance including Daylight Factors of scale model in order to verify the applicability of the simplified equation, and proved the analyzed values are acceptable. When we have a target value of the Daylight Factor, we just have to determine the window area, transmittance of the glazing system, and indoor surface reflectance, then can achieve it with this simplified equation.