• Title/Summary/Keyword: simple procedure

Search Result 1,836, Processing Time 0.036 seconds

Design Methods for Eccentrically Loaded Bolt Groups for the Single Plate Connections Considering Sloped Edge Distance (편심전단을 받는 단일판접합부의 경사연단거리를 고려한 볼트군의 설계법)

  • Choi, Sun Kyu;Yoo, Jung Han;Park, Jai Woo
    • Journal of Korean Society of Steel Construction
    • /
    • v.26 no.1
    • /
    • pp.43-53
    • /
    • 2014
  • A single plate connection(SPC) consists of a plate welded to the columns and bolts connected to the beam web. The SPC is widely used for a simple shear connection of steel structure because it is easy-to-fabricated, easy-to-installed and economical. The conventional SPC is used for 2 to 12 bolts in a single vertical row. It is designed to limit the plate thickness by bolt diameter to obtain flexible and ductile connections. The design strength for eccentric shear shall be the lesser of the shear strength of bolts or bearing strength of plate and when the design strength is decided by edge distance failure, the results can be very conservative. Although the research on special solution for 'weak-plate/strong-bolt' model with 2 to 4 bolts has been conducted by L. S. Muir, and W. A. Thonton, 2004, study on generalized design procedures did not conduct. This study proposed design procedure for evaluation of the design strength of eccentric shear bolt groups on a single plate connection based on the actual edge distance and the direction of bolt reaction forces by using elastic vector method(EVM) and instantaneous center of rotation method(ICM).

Chest Wall Reconstruction with Thoracoabdominal Flap for Large Skin Defects after Mastectomy of Advanced Breast Cancer (진행성 유방암에 있어 유방절제술 후 발생한 광범위 피부결손 부위의 가슴배피판을 이용한 흉벽재건술)

  • Kim, Hak-Tae;Yang, Jung-Dug;Chung, Ho-Yun;Cho, Byung-Chae;Kim, Gui-Rak;Choi, Kang-Young;Lee, Jung-Hun;Park, Ho-Yong
    • Archives of Plastic Surgery
    • /
    • v.37 no.6
    • /
    • pp.736-741
    • /
    • 2010
  • Purpose: Radical surgical extirpation in advanced breast cancer patients produces extensive loss of skin with large defects requiring plastic surgical procedures for the closure. Many reconstructive methods exist, the choice of which depends upon the characteristic of the wound, extent of resection and patient comorbidities. For adequate coverage of the large skin defects following resection of advanced breast cancer, current authors have performed a thoracoabdominal flap. Methods: From August 2008 to June 2009, 4 cases of thoraco-abdominal flap were performed for chest wall reconstruction after mastectomy of advanced breast cancer. Flap dissection was entirely performed in a subfascial plane and the flap involving the external oblique abdominal muscle. The flap was rotated clockwise in left chest wall defects and counterclockwise in right chest defects and the donor site was closed directly. Results: Their mean age, 55.7 years and the average follow-up interval was 9 months. Patients' oncologic status ranged from stage IIIc to stage IV, it was classified according to the TNM staging system. Flap dimensions ranged between $15{\times}15$ and $25{\times}25\;cm$. One flap sustained a partial loss at the distal margin and revision with pectoralis major musculocutaneous island flap. Conclusion: Large chest wall reconstructions are usually required after radical excision of advanced cancer stages patients with poor general conditions. Thoracoabdominal flap is a simple, quick single-stage procedure, and offer to patient fast recovery, low complication rate, enabling further concomitant adjuvant therapy.

Experimental Studies of the Pericardial Substitutes in Rabbits (가토에서 심낭대치물에 관한 실험적 연구)

  • Baeck, Seung-Hwan;Yang, Suk-Rhin;Kim, Sun-Han;Nam, Choong-Hee;Lee, Khil-Rho
    • Journal of Chest Surgery
    • /
    • v.22 no.5
    • /
    • pp.724-730
    • /
    • 1989
  • The development of severe pericardial adhesion after cardiovascular surgical procedures often increases the risk of injuring the heart, great vessels, or extracardiac grafts during resternotomy. Several pericardial substitutes have been tested in an attempt to facilitate reoperation with inconclusive results. This study was designed to evaluate the applicability of two different materials as pericardial substitutes to minimize the pericardial adhesion and epicardial reaction. A procedure for induction of pericardial adhesion was carried out in 30 rabbits. Rabbits were divided into three groups of ten rabbits each: Group 1[control, simple pericardial closure]: Group 2[bovine pericardium as pericardial substitute]: Group 3[e-polytetrafluoroethylene surgical membrane, e-PTFE as a pericardial substitute]. Bovine pericardium or e-PTFE surgical membrane was interposed between the sternum and the heart. Rabbits were sacrificed at 4 weeks after operation. The development of adhesions and epicardial reactions were graded as: none [I]; minimal[II]; moderate[Ill]; and severe[1V]. Histologic studies of the substitute, the pericardium, and the epicardium were performed. The results were as follows; l. In group 1[control group], the degree of pericardial adhesions were grade I in none, grade II in 1, grade III in 3, and grade 1V in 6 animals. Epicardial reactions were grade I in none, grade II in 3, grade K in 4, grade 1V in 3 animals respectively. 2. In group 2[bovine pericardium], the degree of pericardial adhesions were grade I in 1, grade II in 5, grade III in 3, and grade 1V in 1 animal. Epicardial reactions were grade I in 1, grade II in 2, grade III in 4, and grade 1V in 3 animals respectively. 3. In group 3[e-PTFE], the degree of pericardial adhesions were grade I in 7 animals, grade II in 2, grade III in 1, and grade g in none. Epicardial reactions were grade I in 4, grade II in 3, grade III in 2, and grade IV in 1 animal respectively. Pericardial adhesions more than grade II were 90.9% in group 1, 40 % in group 2, and 10% in group 3. Pericardial adhesions were significantly reduced in group 3 compared to group 1 or 2. Epicardial reactions more than grade II were 70 % in group 1, 70 % in group 2 and 30 % in group 3. We concluded that this 0.1mm thick polytetrafluoroethylene surgical membrane is a suitable pericardial substitute to minimize the development of pericardial adhesion or epicardial reaction following cardiovascular surgery.

  • PDF

The Study of the Influence on Long Term Streamflow Caused by Artificial Storage Facilities Based on SWAT Modeling Process (SWAT모형을 이용한 인공저류시설물의 하류장기유출 영향분석 기법에 관한 연구)

  • Shin, Hyun-Suk;Kang, Du-Kee
    • Journal of Korea Water Resources Association
    • /
    • v.39 no.3 s.164
    • /
    • pp.227-240
    • /
    • 2006
  • In the several decades, various storage facilities have been developed and operated to supply water resource, flood control or environmental preservation etc. Then, how those man-maid storage facilities affect on the downstream water and environment and how the hydrologists can evaluate those features for water resources problem-solving are high-concentrated problems in this field. Most large watersheds in Korea contain various types of artificial facilities such dams, reservoirs, in-land ponds, wetlands etc. But the study to develop the technology for achieving the effect of the variances and properties of the long term streamflow caused by the artificial storage facilities have been on the simple watershed models and experimental modeling in the real fields. In this paper, we introduce the procedure and methods to consider the above problems based on continuous and semi-distributed featured SWAT model. At the first, we describe the elements and mechanisms of storage facilities in SWAT model to see how we can apply that in proper and appropriate manner for real field problems. Then, we applied the process to a sample watershed, Taewha River basin which covers the most of Ulsan region. Specially, we concentrate on our effort to the effect of upper reservoirs on down stream long term flows based on various scenario basis. The result was described and analysed in spacial and temporal variations on that basin using the precise manner.

Evaluation of the Clark Unit Hydrograph Parameters Considering Basin and Meteorologic at Conditions : 1. Selection and Analysis of Representative Storm Events (유역 및 기상상태를 고려한 Clark 단위도의 매개변수 평가: 1. 대표 호우사상의 선정 및 분석)

  • Yoo, Chul-Sang;Kim, Kee-Wook;Lee, Ji-Ho
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.2 s.175
    • /
    • pp.159-170
    • /
    • 2007
  • This study evaluated the parameters of Clark unit hydrograph (UH) estimated using the rainfall-runoff measurements and evaluated their variability. This also includes the quantification of basin and meteorological factors using probability density functions, selection of storm events with mean affecting factors, and derivation of average parameters of the Clark UH from storm events selected. Summarizing the results from this procedure are as follows. (1) It is not easy to avoid much uncertainty on the decision of runoff characteristics (that is, the concentration time and storage coefficient) even with some rainfall-runoff events are available. (2) As the distribution function of concentration time is very skewed, a simple arithmetic mean may lead a biased estimate. That is, the arithmetic mean based on the normal distribution can not be representative anymore. The mode may well be the representative in this case. On the other hand, the storage coefficient shows a symmetric distribution function, so the arithmetic mean may be used use for its representative. For the basin in this study, the concentration time in this study is estimated to be about 7 hours, and the storage coefficient about 22 hours.

Scintigraphy with Indium-111-oxine Labeled Leukocytes for Localization of Abscesses (복부농양진단을 위한 Indium-111 표지백혈구스캔)

  • Kim, Byung-Tae;Lee, Dong-Soo;Lee, Kyung-Soo;Choi, Hyung-Shik;Kim, Myung-Joon;Yang, Seung-O;Lee, Jae-Hoon;Choi, Chang-Soon;Kim, Taek-Kyu;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.24 no.1
    • /
    • pp.37-48
    • /
    • 1990
  • Detection of deep-seated abscesses is sometimes difficult with ultrasonogrpahy or computed tome graphy alone. Indium-111-labeled leukocyte has widely used in the localization of abscesses after introduction by Segal and Thakur in 1976. But there are some difficulties in using indium-111-oxine in our country because of hardness to get the radiopharmaceutical timely and long time for labeling leukocytes. So we peformed the indium-111-labeled leukocyte scan for establishment of the labeling procedure and clinical application. We labeled the mixed leukocytes from 36 ml of patient's blood using 4 ml of ACD solution, 7 ml of 6% hydroxyethyl starch solution $(HESPAN^{(R)})$, 1 mCi of indium-111 oxine, 5 ml of normal saline and centrifuge. It took about 2 hours for the preparation of radiolabeled leukocytes and attention for contamination was needed. The average injected dose of labeled mixed leukocytes was 465 uCi. The average number of injected leukocytes was $2.5\times10^8$ and the labeling ratio was $57{\pm}13%$ (Table 2, Fig. 5). These number and ratio were sufficient for the localization of abscess. About twenty per cent of indium was labeled to red blood cells and platelets (Fig. 6) and the half-life of injected radiolabeled leukocytes was 8.3 hours. Scan was performed in 9 patients who were suspected to have abscesses clinically or radiologically. Three patients were positive, in one patient who had abscess close to lower lumbar vertebrae was surgically drained and another 2 positive cases did not show abscess clearly on computed tomography, so only antibiotics were administrated and treated successfully. The negative 6 patients were improved without specific treatment. In conclusion, the use of indium-111 oxine labeled leukocytes for localization of abscesses were very specific and helpful in the decision of treatment considering its relatively simple labeling method, and could be easily performed providing timely supply of the radiopharmaceutical.

  • PDF

Quantitative Analysis of Acid Value, Iodine Value and Fatty Acids Content in Sesame Oils by NIRS (근적외선분광광도법을 이용한 참기름의 산가, 요오드가, 지방산정량법에 관한 연구)

  • Kim, Jae-Kwan;Lee, Myung-Jin;Kim, Myung-Gill;Kim, Kyung-A;Park, Eun-Mi;Kim, Young-Sug;Ko, Hoan-Uck;Son, Jin-Seok
    • Journal of Food Hygiene and Safety
    • /
    • v.21 no.4
    • /
    • pp.204-212
    • /
    • 2006
  • This study was conducted to investigate the possibility of rapid and non-des tructive evalution of AV (Acid Value), IV (Iodine Value) and fatty acids in sesame oils. The samples were scanned over the range $400\sim2500nm$ using transmittance spectrum of NIRS(Near-infrared spectroscopy). A calibration equation calculated by MPLS regression technique was developed and correlation coefficient of determination for AV, IV, palmitic acid, stearic acid, linoleic acid and linolenic acid content were 0.9907, 0.9677, 0.9527, 0.9210, 0.9829, 0.9736 and 0.9709 respectively. The validation model for measuring the AV content had R of 0.989, SEP of 0.058 and IV content had R of 0.944, SEP of 0.562 and palmitic acid content had R of 0.924, SEP of 0.194 and stearic acid content had R of 0.717, SEP of 0.168 and oleic acid content had R of 0.989, SEP of 0.221 and linoleic acid content had R of 0.967, SEP of 0.297 and linolenic acid content had R of 0.853, SEP of 0.480 by MPLS. The obtained results indicate that the NIRS procedure can potentially be used as a non-destructive analysis method for the purpose of rapid and simple measurement of AV, IV and fatty acids in sesame oils.

Method for Screening and Confirming Meldonium in Human Urine by High-Resolution Mass Spectrometry and Identification of Endogenous Interferences for Anti-Doping Testing

  • Kim, Yongseok;Jeong, Dawon;Min, Hophil;Sung, Changmin;Park, Ju-hyung;Son, Junghyun;Lee, Kang Mi;Kim, Ho Jun;Lee, Jaeick;Kwon, Oh-Seung;Kim, Ki Hun
    • Mass Spectrometry Letters
    • /
    • v.8 no.2
    • /
    • pp.39-43
    • /
    • 2017
  • Meldonium is a drug for treating ischemia by expanding the arteries but it can also enhance the performance of sports players. The World Anti-Doping Agency (WADA) has included it in the list of prohibited substances since 2016. Meldonium is one of the challenging substances for anti-doping testing because it is difficult to recover by general liquid-liquid or solid phase extraction due to its permanent charge and high polarity. Therefore, high-performance liquid chromatography (HPLC) is currently used by injecting a diluted urine sample (known as the "dilute-and-shoot" strategy). There is no loss of target compounds in the extraction/cleanup procedure but its high matrix effect could interfere in their separation or detection from the endogenous urinary compounds. We report a single method using high-resolution mass spectrometry that can be used for both screening and confirmation, which follows the "dilute-and-shoot" strategy. In this method, the endogenous compounds' interfering peaks in the mass spectrum are separated at a high resolution of FWHM 140,000, and the results are suitable for substance detection following the WADA guidelines. The interferences in the obtained mass spectrum of the urine matrix are identified as acetylcholine, lysine, and glutamine by further analysis and database searching. Validation of the method is performed in routine anti-doping testing, and the limit of detection is 50 ng/mL. This method uses simple sample preparation and a general reverse phase HPLC column, and it can be easily applied to other substances.

Guidelines for Free-Hand Aspiration(FHA) of Putaminal Hemorrhage (피각부 자발성 뇌내출혈의 혈종흡입술을 위한 지표)

  • Yim, Sin Gil;Oh, Min Suk;Lim, Jun Seob;Kang, Myung Gi;Kwak, Yeon Sang;Park, Seung Gyu;Song, Gyung Bae;Kim, Han Yung
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.294-299
    • /
    • 2001
  • Objectives : CT-guided stereotactic evacuation for spontaneous intracerebral hemorrhage can minimize the brain damage and can be performed safely and simply under local anesthesia. But that procedure is time consuming and has a risk of rebleeding because of the stress during head pin fixation. So authors describe easy and precise guidelines for FHA of putaminal hemorrhage without stereotactic instrument. Methods and Materials : We analyzed the data of 298 patients who underwent CT-guided stereotactic aspiration of putaminal hematoma in our hospital between January 1990 and December 2000. We divided the patients into three groups according to the location of hematoma : anterior portion, middle portion and posterior portion of putamen. Total number of catheters inserted into the hematoma were 345 and there were with regard to the direction and depth of catheters. Results : Proposed guidelines of catheter insertion to putaminal hemorrhage in our institution. 1) hematoma at the anterior portion of putamen ; Direction of catheter was the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between external auditory meatus(EOM) and 1cm posterior to EOM. Depth of catheter was 6-6.5cm. 2) hematoma at the middle portion of putamen ; Direction of catheter was the midpupillary line of the the eye and the point intersecting a line drawn from the burr hole to a point between 1cm and 2cm posterior to EOM. Depth of catheter was 6.5-7cm. 3) hematoma at the posterior portion of putamen ; Direction of catheter was 15 degree laterally from the midpupillary line of the eye and the point intersecting a line drawn from the burr hole to a point between 2cm and 3cm posterior to EOM. Depth of catheter was 7-7.5cm. We have performed FHA of putaminal hemorrhage in 48 cases according to this guideline. All catheter were inserted exactly at the center of hematoma and average operation time was about 30 minutes. Conclusion : Our proposed guidelines for putaminal hemorrhage are considered to be safe and simple method with similar accuracy and rapid decompression compared with traditional stereotactic method. Main advantages of this technique were unnecessity of stereotactic frame application and less time requirement for hematoma removal.

  • PDF

Association-Based Knowledge Model for Supporting Diagnosis of a Capsule Endoscopy (캡슐내시경 검사의 진단 보조를 위한 연관성 기반 지식 모델)

  • Hwang, Gyubon;Park, Ye-Seul;Lee, Jung-Won
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.6 no.10
    • /
    • pp.493-498
    • /
    • 2017
  • Capsule endoscopy is specialized for the observation of small intestine that is difficult to access by general endoscopy. The diagnostic procedure through capsule endoscopy consists of three stages: examination of indicant, endoscopy, and diagnosis. At this time, key information needed for diagnosis includes indicant, lesions, and suspected disease information. In this paper, these information are defined as semantic features and the extracting process is defined as semantic-based analysis. It is performed in whole capsule endoscopy. First, several symptoms of patient are checked before capsule endoscopy to get some information on suspected disease. Next, capsule endoscopy is performed by checking the suspected diseases. Finally, diagnosis is concluded by using supporting information. At this time, some association are used to conclude diagnosis. For example, there are the disease association between the symptom and the disease to identify the expected disease, and the anatomical association between the location of the lesion and supporting information. However, existing knowledge models such as MST and CEST only lists the simple term related to endoscopy and cannot consider such semantic associations. Therefore, in this paper, we propose association-based knowledge model for supporting diagnosis of capsule endoscopy. The proposed model is divided into two; a disease model and anatomical model of small intestine, interesting area(organs) of capsule endoscopy. It can effectively support diagnosis by providing key information for capsule endoscopy.