Browse > Article
http://dx.doi.org/10.7781/kjoss.2014.26.1.043

Design Methods for Eccentrically Loaded Bolt Groups for the Single Plate Connections Considering Sloped Edge Distance  

Choi, Sun Kyu (Sunyoung Architects & Engineering Consultants)
Yoo, Jung Han (School of Architecture, Seoul National University of Science & Technology)
Park, Jai Woo (Gayoon Co. Ltd., Department of Architectural Engineering, Kwangwoon University)
Publication Information
Journal of Korean Society of Steel Construction / v.26, no.1, 2014 , pp. 43-53 More about this Journal
Abstract
A single plate connection(SPC) consists of a plate welded to the columns and bolts connected to the beam web. The SPC is widely used for a simple shear connection of steel structure because it is easy-to-fabricated, easy-to-installed and economical. The conventional SPC is used for 2 to 12 bolts in a single vertical row. It is designed to limit the plate thickness by bolt diameter to obtain flexible and ductile connections. The design strength for eccentric shear shall be the lesser of the shear strength of bolts or bearing strength of plate and when the design strength is decided by edge distance failure, the results can be very conservative. Although the research on special solution for 'weak-plate/strong-bolt' model with 2 to 4 bolts has been conducted by L. S. Muir, and W. A. Thonton, 2004, study on generalized design procedures did not conduct. This study proposed design procedure for evaluation of the design strength of eccentric shear bolt groups on a single plate connection based on the actual edge distance and the direction of bolt reaction forces by using elastic vector method(EVM) and instantaneous center of rotation method(ICM).
Keywords
Single plate connection(SPC); EVM; ICM; Design table;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 최선규, 유정한, 이강민, 박재우(2012) 비보강받침접합의 용접강도와 설계도표, 한국강구조학회논문집, 한국강구조학회, 제24권, 제2호, pp.199-206. Choi, S.K., Yoo, J.H., Lee, K.M., and Park, J.W. (2012) "The weld strength and design table for the unstiffened seated connections", Journal of Korean Society of Steel Construction, Vol.24, No.2, KSSC, pp.199-206.   과학기술학회마을   DOI
2 Muir, L.S. and Thornton, W.A. (2004) An alternative approach to design of eccentrically loaded bolt groups, Connections in Steel Structures V, Amsterdam, pp.273-279.
3 최선규(2011) 단순전단접합부의 설계와 표준상세, 한국강구조학회지, 한국강구조학회, 제23권, 제4호, pp.6-10. Choi, S.K. (2011) Design & Standard Details of Simple Shear Connections for Steel Structures, Magazine of the Korean Society of Steel Construction, Vol.23, No.4, KSSC, pp.6-10 (in korean).
4 AISC (2010) Specification for Structural Steel Buildings, American Institute of Steel Construction, USA.
5 최선규, 박재우, 유정한(2012) 편심전단을 받는 단일판접합부 볼트군에 대한 연구, 한국강구조학회 학술발표대회논문집, 한국강구조학회, pp.145-146. Choi, S.K., Park, J.W., and Yoo, J.H. (2012) "A Study on the Design of Eccentrically Loaded BoltGroups for the Single Plate Connections", Conference Journal of Korean Society of Steel Construction, KSSC, pp.145-146.
6 Astaneh, A., Call, S.M., and Mcmullin, K.M. (1989) Design of single plate shear connections., Engineering Journal, AISC, pp.21-32.