• Title/Summary/Keyword: simple procedure

Search Result 1,836, Processing Time 0.03 seconds

A Study on the Correction Factor of Flow Angel by using the One Dimentional Performance Model of Torque Converter (토크 컨버터의 1차원 성능 모델을 이용한 유동 각도 보정 계수에 관한 연구)

  • Im, Won-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.2 s.173
    • /
    • pp.506-517
    • /
    • 2000
  • One dimensional performance model has been used for the design of torque converter. The model is based on the concept of constant mean flow path and constant flow angle. These constant-assumed para meters make the design procedure to be simple. In practice, some parameters are usually replaced with geometric raw data and, the constant experiential correction factors have been used to minimize the design error. These factors have no definite physical meaning and so they cannot be applied confidently to the other design condition. In this study, the detail dynamic model of torque converter is presented to establish the theoretical background of correction factors. To verify the validity of theoretical model, steady state performance test was carried out on the several input speed. The oil temperature effect on the performance is analysed and adjusted. The constant equivalent flow angles are determined at a part of performance region by comparing the theoretical model and the test data. The sensitivity of correction factors to the input speeds are studied and the change of torus flow is presented.

Institutional Applications of Eclipse Scripting Programming Interface to Clinical Workflows in Radiation Oncology

  • Kim, Hojin;Kwak, Jungwon;Jeong, Chiyoung;Cho, Byungchul
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.122-128
    • /
    • 2017
  • Eclipse Scripting Application Programming Interface (ESAPI) was devised to enhance the efficiency in such treatment related workflows as contouring, treatment planning, plan quality measure, and data-mining by communicating with the treatment planning system (TPS). It is provided in the form of C# programming based toolbox, which could be modified to fit into the clinical applications. The Scripting program, however, does not offer all potential functionalities that the users intend to develop. The shortcomings can be overcome by combining the Scripting programming with user-executable program on Windows or Linux. The executed program has greater freedom in implementation, which could strengthen the ability and availability of the Scripting on the clinical applications. This work shows the use of the Scripting programming throughout the simple modification of the given toolbox. Besides, it presents the implementation of combining both Scripting and user-executed programming based on MATLAB, applied to automated dynamic MLC wedge and FIF treatment planning procedure for promoting the planning efficiency.

For the development of software industry, extensive software certification scheme (소프트웨어 산업의 발전을 위한 확장된 소프트웨어 인증체계)

  • Seo, Hee Suk;Kim, Sang Ho;Lee, Seung Jae
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.6 no.3
    • /
    • pp.121-129
    • /
    • 2010
  • For the development of software industry, offers an expanded software authentication scheme caused by the unauthorized copying of software is to reduce the damage to software developers, retail sales and to promote the development of the software industry was studied. Serial Number of the current software registration is conducted in such a simple verification procedure if the Serial Number only illegal and can be installed on multiple computers, such as program code to allow third parties to enter the Serial Number, or the extract can be used without is a reality. The proposed extension to the software authentication system when you install the software, my phone authentication and MAC Address Authentication Service introduced to distinguish normal user, the user of the MAC Address of the server and software development company that was sent to the registered MAC Address of the computer to be run only by the use of genuine software and to make unauthorized copies of software generated by the software developer can reduce the damage of the proposed plan.

Simultaneous Quantification of Sulfonamide and Tetracyclines in Fish Muscle Tissue by Matrix Solid Phase Dispersion (MSPD) Extraction and HPLC (MSPD와 HPLC를 이용한 어류의 잔류 설파제와 테트라사이클린계 항생물질의 동시분석)

  • 하대식;김종수;김곤섭
    • Journal of Food Hygiene and Safety
    • /
    • v.12 no.2
    • /
    • pp.117-124
    • /
    • 1997
  • A simple, rapid and simultaneous analytical method is described for the detection of Sulfonamide and Tetracycline residues, i.e., Sulfamerazine (SMR), Sulfamethazine (SMT), Sulfamonomethoxine (SMM), Sulfadimethoxine (SDM), Sulfaquinoxaline (SQN), Oxytetracycline (OXY), Tetracycline (TC), Chlortetracycline (CTC). Blank control and sulfonamide and tetracycline fortified fish muscle samples (0.5 f) were blended with octadecylsilyl (C18, 40 ${\mu}{\textrm}{m}$, 21% load, 60$\AA$) derivatized silica packing material (2 g). Blended fish samples were washed with hexane, then, benzene and dichloromethace were used for the elution of tetracycline and sulfonamide were analyzed by HPLC. Correlation coefficients of standard curves for individual sulfonamide and tetracycline isolated from fortified samples were linear (0.9993$\pm$0.0003~0.9997$\pm$0.0003, 0.9493$\pm$0.078~0.9753$\pm$0.036), respectively. The average percentage recoveries of sulfonamide and tetracycline ranged as 80.86~96.52% to 85.88~92.23%, and 30.01~37.12% to 65.89~73.40%, for the concentration range (0.1~1.0 ppm) examined, respectively. Limit of detection for sulfonamide was 0.0012 ppm for SMR in Paralichthys Olivacleus and 0.0020 ppm for SMR, 0.015 ppm for SMM in Cyprinus Carpio. The applicability of this procedure is demonstrated by separation and detection of incurred tetracycline and sulfonamide residues in fish muscle tissue.

  • PDF

Research for the Analytical Method of Various Pesticides in Raw Milk by Gas Chromatography-Mass Spectrometry (GC/MSD를 사용한 원유 내 잔류농약의 분석법 연구)

  • Oh, N.S.;Shin, Y.K.;Baick, S.C.
    • Food Science of Animal Resources
    • /
    • v.29 no.4
    • /
    • pp.482-486
    • /
    • 2009
  • The aim of this study was to optimize a simple, fast, and economical analysis procedure for the determination of 16 different pesticides in raw milk via GC/MSD. Analyses were performed via gas chromatography with electron impact mass spectrometric detection in the selected ion monitoring mode (GC/MSD-SIM) using Pentachloronitrobenzene as the internal standard. The modified sample preparation methodology was based on the Pesticide Analytical Manual (PAM) of the FDA concerning fat extraction, ACN-ether partitioning, and clean-up of the Sep-Pak florisil cartridge. The modified methodology for the determination of the 16 pesticides was validated. The range of LOQs of the 16 pesticides was likely three times lower than their Maximum Residence Levels (MRLs). The recoveries of most of the pesticides were acceptable at the fortification levels of 0.5 and 1.0 ${\mu}g/mL$ and their RSD (%) level was less than 20%. None of the 16 pesticides were detected in the selected raw milk samples.

Magnetic Circuit Design Methodology of MR CDC Dampers for Semi-Active Suspensions (반능동 서스펜션용 MR CDC 댐퍼의 자기회로 설계기법)

  • Park, Jae-Woo;Jung, Young-Dae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.10
    • /
    • pp.48-57
    • /
    • 2008
  • MR Fluid, one of functional fluids, is developed for the application to automobile products. MR CDC damper using MR fluid has following principles. When ar electric current is applied to the solenoid, apparent viscosity of MR fluid passing through the annular gap which acts as magnetic circuits varies directly as the intensity of the current. These devices have a simple structure and excellent lime response characteristics, emerging as the alternatives of the conventional semi-active suspension systems. In this study, a design procedure of the magnetic circuit through the solenoid fore and the flux ring functioning as a magnetic path is investigated so as to optimize the design and performance of MR CDC dampers for the vehicles. In addition, an operating point on the B-H curve, the magnetization according to the variation in the annular gap, the pole piece width and the density of MR fluid are studied to design the optimal piston head within the restrained dimension range.

Prediction of thermal shock failure of glass during PDP manufacturing process (PDP 제조 공정시 유리의 열충격 파손 예측)

  • 김재현;최병익;이학주
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.2
    • /
    • pp.122-129
    • /
    • 2004
  • There is an increasing need for large flat panel display devices. PDP (Plasma Display Panel) is one of the most promising candidates for this need. Thermal shock failure of PDP glass during manufacturing process is a critical issue in PDP industry since it is closely related to the product yield and the production speed. In this study, thermal shock resistance of PDP glass is measured by water quenching test and an analysis scheme is described for estimating transient temperature and stress distributions during thermal shock. Based on the experimental data and the analysis results, a simple procedure for predicting the thermal shock failure of PDP glass is proposed. The fast cooling process for heated glass plates can accelerate the speed of PDP production, but often leads to thermal shock failure of the glass plates. Therefore, a design guideline for preventing the failure is presented from a viewpoint of high speed PDP manufacturing process. This design guideline can be used for PDP process design and thermal -shock failure prevention.

Clinical Study of 53 Patients Requiring open Thoracotomy After Thoracic Injuries (흉부외상 환자중 개흉술이 필요했던 53례에 관한 임상적 고찰)

  • 김규만
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1115-1124
    • /
    • 1991
  • Recently the thoracic injuries have been markedly increasing due to the vast increase of traffic accident, industrial disaster, and incidental accident as well as the frequent use of the murderous weapons including gun or rifle. Because the thoracic injuries could involve the heart, lung, and great vessels, and would influence the lives, prompt diagnosis and adequate treatment are essential. Most of thoracic injuries can be managed with the conservative treatment and simple surgical procedure such as closed thoracostomy, but certain cases require open thoracotomy to preserve lives and to return to their normal environment. The authors have analysed the result of 53 cases of open thoracotomy after thoracic injuries mainly according to the patient`s chart review. The mean age was 33.4 years old and male to female ratio was about 5: l. Injury mechanisms that elicited thoracic trauma indicated for open thoracotomy were penetrating[47%] and non-penetrating[53%] injuries. The Most common type of the thoracic lesion was hemothorax with or without pneumothorax and diaphragm rupture was the second. 58\ulcornero of thoracic injuries were accompanied by abdominal injuries and 47% by bone fractures. 34 patients were operated within 24 hours after injury and their average elapsed time was 13.6 hour. The remained patients were operated after 24 hours and their average elapsed time was 7.8 days. 71 cases of operative procedures containing some overlappings were performed: diaphragm repair[28], bleeding control[12], pulmonary and cardiac repair[4 cases] Postoperative complication rate was 32.1% and operative mortality rate was 9.4%[5/53].

  • PDF

Quantitative Analysis of Epicardial fat (심외막 지방의 정량분석)

  • O, Jung-Hwan;Gang, Cheong-Hui;Lee, Jong-Guk
    • Journal of Chest Surgery
    • /
    • v.28 no.3
    • /
    • pp.233-236
    • /
    • 1995
  • Subepicardial space is one of the regions in which fat in moderate amount is normally deposited. When excess deposits of epicardial fat occur, penetration or infiltration of fat into the connective tissues between muscle bundles is observed. In some cases with very extensive involvement of epicardial fat,myocardial insufficiency and conduction system defect such as heart block have been implicated. More fat is deposited over the right ventricle than over left and the anterior surface contains more fat than dose the posterior surface. We studied 40 patients who underwent open heart surgery under the cardiopulmonary bypass. This study was designed to evaluate the percentage of the area of epicardial fat of the right ventricular anterior surface, which is more accessible area during the operative procedure. Other variables included thickness of subcutanous tissue of anterior chest wall, the ratio of waist to hip circumference, body weight and age. In conclusion, the amount of the epicardial fat correlates with thickness of the subcutaneous fat of the anterior chest wall and simple linear regression analysis indicates good correlation with body weight. Increased age results in large amount of epicardial fat.

  • PDF

Nondestructive Determination of Humic Acids in Soils by Near Infrared Reflectance Spectroscopy

  • Seo, Sang-Hyun;Park, Woo-Churl;Cho, Rae-Kwang;Xiaori Han
    • Near Infrared Analysis
    • /
    • v.1 no.1
    • /
    • pp.31-35
    • /
    • 2000
  • Near-infrared reflectance spectroscopy(NIRS) was used to determine the humic acids in soil samples from the fields of different crops and land-use over Youngnam and Honam regions in Korea. An InfraAlyzer 500 scanning spectrophotometer was obtained near infrared relectance spectra of soil at 2-nm intervals from 1100 to 2500nm. Multiple linear regression(MLR) or partial least square regression (PLSR) was used to evaluate a NIRS method for the rapid and nondestructive determination of humic acid, fulvic acid and its total contents in soils. The raw spectral data(log 1/R) can be used for estimating humic acid, fulvic acid and its total contents in soil by MLR procedure between the content of a given constituent and the spectral response of several bands. In which the predicted results for fulvic acid is the best in the constituents. The new spectral data are converted from the raw spectra by PLSR method such as the first derivative of each spectrum can also be used to predict humic acid and fulvic acid of the soil samples. A low SEC, SEP and a high coefficient of correlation in the calibration and validation stages enable selection of the best manipulation. But a simple calibration and prediction method for determining humic acid and fulvic acid should be selected under similar accuracy and precision of prediction. NIRS technique may be an effective method for rapid and nondestructive determination for humic acid, fulvic acid and its total contents in soils.