• 제목/요약/키워드: similar range

검색결과 3,386건 처리시간 0.032초

진공청소기용 저소음 터보팬 내부 유동 특성 해석 (Flow Analysis of a Low-Noise Turbo Fan for a Vacuum Cleaner)

  • 이기춘;김창준;허남건;전완호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.631-634
    • /
    • 2002
  • The study of the flow characteristics in two types of turbo-fans for a vacuum cleaner was performed in a previous study. In present study an analysis of a new modified model to reduce fan noise was performed by using CFD. The characteristics of three models calculated for various rotating speeds and flow rates are obtained and compared with available measured data. The results show that the modified model gives stable flow characteristics in operating range than the original model, while both models show similar performance characteristics at the range of high flow rate. Since in the modified model it takes much longer for an impeller blade to pass a diffuser blade than in the original model, and thus the peak pressure at BPF can be relieved, it is anticipated that the modified model gives much lower noise level with similar performance than the original one, which remains to be verified by unsteady computation and measurements.

  • PDF

실험실 공기질 개선을 위한 라인디퓨져의 특성 평가 (Characteristic Evaluation of Line Diffusers for Air Quality Improvement of Laboratory)

  • 조수현;이철구
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.14-22
    • /
    • 2008
  • This study is aimed at suggesting a linear-type diffuser which is excellent in terms of range and elegance like existing diffusers in which amount and direction of wind can be freely controled, out of linear-type diffusers with the highest possibility to be adopted for living space of apartments whose height between floors is not so high and utilizing the linear-type diffuser in design. For the purpose, I examined necessary flow and noise properties of linear-type diffusers. Besides, I evaluated its ventilation capacity for persons in there by applying this in the actual living space. I evaluated features and air blast and found that in time of horizontal and vertical effusion, its T/L ratio is 1-1.5, similar to existing cardioid-type linear diffusers, while in time of slope effusion, it is similar to horizontal effusion in terms of range and it has medium figure in terms of pressure drop and effusion speed, indicating it can provide safe and pleasant indoor environment for persons in there in terms of ventilation.

Reversed Two Station Method (RSTM)에 의한 중부지방 $Q_{Lg}^{-1}$ 연구 (A study of $Q_{Lg}^{-1}$ by the reversed two station method in the crust of central South Korea)

  • 정태웅
    • 지구물리
    • /
    • 제5권3호
    • /
    • pp.211-218
    • /
    • 2002
  • $Q_{Lg}^{-1}$를 구하는 방법 중에서 Chun et al. (1987)이 고안한 Reversed two station method (RSTM)는 진앙거리 90 km 이상의 Lg파에 대하여 시행되고 있다. 진앙거리 95 km 에서 381 km에 이르는 중부지역 지진자료에 대하여 RSTM에 의한 $Q_{Lg}^{-1}$를 구한 결과, 비슷한 진앙거리에 대한 동일한 방법으로부터 얻어진 남한 남동부지역의 값과 비슷한 높은 값이 도출되었다. 남한 남동부 및 중부지방의 높은 $Q_{Lg}^{-1}$는 실제와 다른 것으로, RSTM이 본 연구 진앙거리 구간에서는 감쇠율이 표면파 감쇠율 0.5 보다 크기 때문인 것으로 해석된다.

  • PDF

협력필터링 시스템을 위한 평가 등급 범위 기반의 예측방법 (A Rating Range-based Prediction Method for Collaborative Filtering Systems)

  • 이수정
    • 컴퓨터교육학회논문지
    • /
    • 제14권4호
    • /
    • pp.63-70
    • /
    • 2011
  • 인터넷 상에서 사용자 흥미에 부합하는 항목을 예측하여 추천해 주는 추천 시스템은 e-commerce가 발달함에 따라 다양한 분야에서 적용되어 왔다. 추천 시스템의 주요 방법인 협력 필터링은 사용자가 선호했던 항목들과 유사한 항목을 추천하거나 또는 유사한 기호의 다른 사용자가 선호했던 항목을 추천하는 것이다. 따라서 유사도의 정확한 측정과 추천한 항목의 실제 평가등급 예측은 협력 필터링의 성능을 결정하는 두가지 중요한 문제이다. 본 연구에서는 후자의 문제를 다룬다. 기존 연구에서는 평가 등급의 평균값을 기반으로 하여 실제 평가등급을 예측하였으나, 본 연구에서는 평가 등급 범위 기반의 방법을 제시하고 실험을 통해 성능을 조사하였다. 실험 결과 기존 방법에 비해 제안 방법은 평균 절대 오차에 있어서 성능이 크게 향상됨을 입증하였다.

  • PDF

A new cyclopoid copepod from Korean subterranean waters reveals an interesting connection with the Central Asian fauna (Crustacea: Copepoda: Cyclopoida)

  • Karanovic, Tomislav;Yoo, Hyunsu;Lee, Wonchoel
    • Journal of Species Research
    • /
    • 제1권2호
    • /
    • pp.156-174
    • /
    • 2012
  • Monchenkocyclops gen. nov. was erected to accommodate M. changi sp. nov. from South Korea (type species), M. mirabdullayevi sp. nov. from Kazakhstan, M. biarticulatus (Monchenko, 1972) comb. nov. from Uzbekistan, and M. biwensis (Ishida, 2005) comb. nov. from Japan. The latter species was originally described from surface-water habitats of the ancient Lake Biwa in the genus Diacyclops Kiefer, 1927, while two Central Asian species were previously collected from groundwater habitats and assigned to the genus Acanthocyclops Kiefer, 1927. Monchenkocyclops changi is also found in subterranean waters, and described here in detail. It is morphologically most similar to its Uzbek congener (not to the Japanese one), which rises some interesting zoogeographical questions about the disjunct distribution of this genus. Range fragmentation is a more plausible explanation for this distribution pattern than range expansion, and we emphasize four lines of evidence that support this hypothesis. Four species of Monchenkocyclops share not only the same segmentation of the swimming legs, but also the exact same armature formula of all swimming legs, in addition to many other morphological characters, such as the caudal rami shape and armature, absence of exopod on the antenna, similar shape of the seminal receptacle, fifth leg, etc. They can be distinguished mostly by the relative length of different armature elements, such as the innermost terminal caudal setae, and inner setae and apical spines on the third endopodal segment of the fourth leg. A dichotomous key to species is provided.

장거리 수송 연무 발생과 연관된 우리나라 대도시 대기질 특성 (Characteristics of Air Quality over Korean Urban Area due to the Long-range Transport Haze Events)

  • 조현영;김철희
    • 한국대기환경학회지
    • /
    • 제27권1호
    • /
    • pp.73-86
    • /
    • 2011
  • Haze phenomena were analyzed to assess the impact of long range transport process on the air quality of Seoul and Busan. We statistically classified haze days observed in both Seoul and Busan into two types of haze cases: stagnant case and long-range transport case, and analyzed the air pollutant levels comparatively for each of the two cases for the period of 2000~2007. The results showed that the long-range transport haze case occurs less frequently with the occurrence frequency of 35.5% than stagnant case with the occurrence frequency of 64.5%. During the observed all haze days, all pollutants have high concentration in comparison with those under other meteorological conditions (Rain, Mist, Dust, Clear, Rain+Mist) except for only $PM_{10}$ of Dust case where its level shows highest among total 6 categorized conditions. The long range transport haze case shows similar levels of $PM_{10}$ and $NO_2$, but higher $SO_2$ and lower $O_3$ compared with stagnant haze cases, suggesting the importance of sulfur chemistry for long range transport haze case and local photochemistry for stagnant haze case. In addition, by employing the NOAA/HYSPLIT-4 backward trajectory model, we subdivided the long range transport haze cases into two different sources: urban anthropogenic high emission areas of central China, and natural emission sources over north China and/or Mongolia. The former long range transport haze case shows higher occurrence (with Seoul 70% and Busan 85%) than the latter haze case (with Seoul 30% and Busan <10%). This is also implying that the long haze phenomena occurred over Korea have been influenced by not only the anthropogenic emissions but also the natural dust emissions. These both emission sources can be good contributors in calculating the source-receptor relationship over Korean atmospheric environment.

수직관내 발달 유동의 층류혼합대류 연구 (Study on Laminar Mixed Convection of Developing Flow in Vertical Pipe)

  • 고봉진;정범진
    • 대한기계학회논문집B
    • /
    • 제34권5호
    • /
    • pp.481-489
    • /
    • 2010
  • 수직관내 발달 유동의 층류혼합대류에 관한 본 연구는 Re 1,000에서 3,000, $Gr_H\;10^5$에서 $10^8$, Pr 2,000 에서 7,000 그리고 종횡비 1부터 7에 대한 범위에 대해서 수행되었다. 유사성(Analogy)의 원리를 이용하여 수직관내 발달 유동의 층류혼합대류 열전달계를 물질전달계로 모사하였다. 물질전달계로써 Nu 수는 기존의 문헌들의 그것들보다 상당히 큰 값이었는데, 이는 본 실험의 높은 Pr 수 때문이다. 본 연구에서의 종횡비는 완전발달 할 만큼 크지 않았기 때문에, 실험 결과는 긴 수직관내 혼합대류 유동보단 평행평판에서의 혼합대류 유동과 유사하였다. 본 연구의 결론으로서 낮은 종횡비와 $Gr_H$ 수를 갖는 수직관내 발달 유동의 층류혼합대류 유동은 수직 평판에서의 층류혼합대류 유동과 유사한 거동을 보인다는 것이다. 그리고 종횡비와 $Gr_H$ 수가 증가할 때 유체의 거동은 수직관내 완전발달 유동과 유사한 현상을 보였다.

산초(Zanthoxylum Schinifolium) 뿌리, 줄기 및 잎 추출물의 항산화, DDPH Radical 소거 작용 및 항혈전 효과 (Effects of Antioxidative, DPPH Radical Scavenging Activity and Antithrombogenic by the Extract of Sancho (Zanthoxylum Schinilolium))

  • 장미진;우미희;김영호;전도연;이순재
    • Journal of Nutrition and Health
    • /
    • 제38권5호
    • /
    • pp.386-394
    • /
    • 2005
  • Effects of root, stem and leaf extract of sancho (Zanthoxylum schinifolium) on the inhibition of lipid peroxidation in the hepatic microsome of rat, DPPH radical scavenging activity and activated partial thromboplastin times (APTT) were examined in vitro. The highest inhibition of hepatic microsomal lipid peroxidation was observed by ethyl acetate fraction than that of methylene chloride fraction of the root and stem extracts. The high inhibition of lipid peroxidation was determined in the leaf, the root and the stem in order. The DPPH radical scavenging activity of ethyl acetate fraction was higher than that of n-butanol fraction and it was similar to the root and the steam extract. It was similar to the inhibition of hepatic microsomal lipid peroxidation. The DPPH radical scavenging activity was the highest in 2.500mg/mL of ethyl acetate fraction and it was 4.4 fold higher than that of $\alpha-tocopherol$, as an antioxidant standard. The DPPH radical scavenging activity was dependent on the extract concentration in the range of 0.125-5.000 mg/mL. The throm-boplastin times were higher than that of n-butanol fraction and it was similar to the root and the steam extracts. The leaf extract showed the highest antithrombogenic effect followed by the stem and then the root extract. The activated partial thromboplastin times were ependent on the extract concentration in the range of 0.100-2.000 mg/mL. Consequently, the effects of antioxidative, DPPH radical scavenging activity and antithrombogenic of Z. schinifolium was observed due to the inhibition of lipid peroxidation and the DPPH radical scavenging activity by methylene chloride, n-butanol and ethyl acetate fraction of the leaf extract. (Korean J Nutrition 38(5): 386 - 394, 2005)

SOME PROSODIC FEATURES OBSERVED IN THE PASSAGE READING BY JAPANESE LEARNERS OF ENGLISH

  • Kanzaki, Kazuo
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 1996년도 10월 학술대회지
    • /
    • pp.37-42
    • /
    • 1996
  • This study aims to see some prosodic features of English spoken by Japanese learners of English. It focuses on speech rates, pauses, and intonation when the learners read an English passage. Three Japanese learners of English, who are all male university students, were asked to read the speech material, an English passage of 110 word length, at their normal reading speed. Then a native speaker of English, a male American English teacher. was asked to read the same passage. The Japanese speakers were also asked to read a Japanese passage of 286 letters (Japanese Kana) to compare the reading of English with that of japanese. Their speech was analyzed on a computerized system (KAY Computerized Speech Lab). Wave forms, spectrograms, and F0 contours were shown on the screen to measure the duration of pauses, phrases and sentences and to observe intonation contours. One finding of the experiment was that the movement of the low speakers' speech rates showed a similar tendency in their reading of the English passage. Reading of the Japanese passage by the three learners also had a similar tendency in the movement of speech rates. Another finding was that the frequency of pauses in the learners speech was greater than that in the speech of the native speaker, but that the ration of the total pause length to the whole utterance length was about tile same in both the learners' and the native speaker's speech. A similar tendency was observed about the learners' reading of the Japanese passage except that they used shorter pauses in the mid-sentence position. As to intonation contours, we found that the learners used a narrower pitch range than the native speaker in their reading of the English passage while they used a wider pitch range as they read the Japanese passage. It was found that the learners tended to use falling intonation before pauses whereas the native speaker used different intonation patterns. These findings are applicable to the teaching of English pronunciation at the passage level in the sense that they can show the learners. Japanese here, what their problems are and how they could be solved.

  • PDF

정규화된 분산을 이용한 프랙탈 압축방법 (A Fast Fractal Image Compression Using The Normalized Variance)

  • 김종구;함도용;위영철;김하진
    • 정보처리학회논문지A
    • /
    • 제8A권4호
    • /
    • pp.499-502
    • /
    • 2001
  • 프랙탈 코딩은 높은 압축률을 포함한 여러 가지 장점을 가지고 있으나 유사블록 탐색에 긴 시간이 소요되는 문제점을 가지고 있다. 본 논문은 각 블록의 정규화 된 분산 값은 명도(contrast)와 밝기(brightness)에 독립적임을 발견하고, 이를 이용하여 d(key의 수)차원 공간에서 최근접부근탐색(nearest neighbor search)을 하여 효율적인 유사블록을 탐색하는 방법을 제안한다. 본 방법은 각 치역 블록 당 Ο(log N), (N : 정의역블록 수) 시간에 유사 정의역 블록 찾을 수 있음을 보였다. 압축처리 된 이미지는 각 치역 블록 당 Ο(N) 시간이 요구되는 전체탐색의 PSNR (Peak Signal Noise Ratio)과 거의 같은 값을 얻게 되었다. 또한, 본 방법은 에지가 많은 이미지에도 전체탐색과 거의 유사한 PSNR로 압축되는 장점을 가진다.

  • PDF