• Title/Summary/Keyword: silver chloride

Search Result 89, Processing Time 0.029 seconds

Organopalladium(II) Complexes as Ionophores for Thiocyanate Ion-Selective Electrodes

  • Kim, Dong-Wan;Lee, So-Hyun;Kim, Jung-Hwan;Kim, Jin-Eun;Park, Jong-Keun;Kim, Jae-Sang
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.10
    • /
    • pp.2303-2308
    • /
    • 2009
  • A thiocyanate poly(vinyl chloride) (PVC) membrane electrode based on [1,2-bis(diphenylphosphino)ethane]dihalopalladium( II), [(dppe)$PdX_2$, X = Cl ($L^1$), X = I ($L^2$)] as active sensor has been developed. The diiodopalladium complex, [(dppe)$PdI_2](L^2$) displays an anti-Hofmeister selectivity sequence: $SCN^-\;>\;I^-\;>\;{ClO_4}^-\;>\;Sal^-\;>\;Br^-\;>\;{NO_2}^-\;>\;{HPO_4}^-\;>\;AcO^-\;>\;{NO_3}^-\;>\;{H_2PO_4}^-\;>\;{CO_3}^{2-}$. The electrode exhibits a Nernstian response (-59.8 mV/decade) over a wide linear concentration range of thiocyanate ($(1.0\;{\times}\;10^{-1}\;to\;5.0\;{\times}\;10^{-6}$ M), low detection limit ($(1.1\;{\times}\;10^{-6}$ M), fast response $(t_{90%}$ = 24 s), and applicability over a wide pH range (3.5∼11). Addition of anionic sites, potassium tetrakis[p-chlorophenyl] borate (KTpClPB) is shown to improve potentiometric anion selectivity, suggesting that the palladium complex may operate as a partially charged carrier-type ionophore within the polymer membrane phase. The reaction mechanism is discussed with respect to UV-Vis and IR spectroscopy. Application of the electrode to the potentiometric titration of thiocyanate ion with silver nitrate is reported.

Do Paneth Cells Regulate the Zinc Body Burden? (Zinc 대사와 관련된 Paneth 세포활성의 변화에 관한 조직화학적 연구)

  • Jo, Seung-Mook;Kim, Sung-Jun;Park, Seung-Kook;Kang, Tae-Cheon;Won, Moo-Ho
    • Applied Microscopy
    • /
    • v.30 no.4
    • /
    • pp.357-365
    • /
    • 2000
  • Paneth cells have been suggested to contribute to the elimination of excess metals into the intestinal lumen. The purpose of this study wat to investigate the changes of the zinc pools in rats subjected to functional loading with zinc salt by mean of both light and electron microscopical autometallography (AMG). Wistar rats 4 were administrated with zinc chloride (20 mg/kg body weight) intraperitoneally dissolved in 1 ml distilled water. The control group received 1 ml saline IP. After further one hour the animals were transcardially perfused with 0.4% sodium sulphide dissolved in 0.1 M PB fellowed by 3% glutaraldehyde solution for 10 minutes. Pieces of ileum were frozen with solid $CO_2$ and sectioned on a cryostat. The sections $(20{\mu}m)$ were autometallographically developed. Sections selected for EM were reembedded on top of a blank Epon block, from which ultrathin sections (100 nm) were cut. The ultrathin sections were double stained with uranyl acetate (30 min) and lead citrate (5 min), then examined under electron microscope. Studies of comparable sections from control and zinc loaded animals with the AMG selenium method gave quite different results. The control animals demonstrated a weakly positive staining in the cytoplasm of the Paneth cells. In the electron microscope the AMG silver grains were found to be located in the cytoplasm, while the electron dense secretary granules and other cell organelles were void of staining. Few AMG grains were located at the apical surface of the Paneth cells. In sections from zinc loaded rats, the AMG grains were seen in abundance in the lumen of the Lieberkuhn crypts at light microscopic levels. At EM levels the zinc revealing silver grains were located in the cytoplasm as in the controls, but much more AMG grains were shifted into the secretary granules. Furthermore, profound AMG grains were found in the lumen of the crypts and surrounding vessels. And a few grains were seen in the endothelium. The AMG technique demonstrated a pattern of AMG grains in the Paneth cells that strongly suggests a transport of zinc ions through these cells.

  • PDF

Scientific Analysis and Conservation Treatment on the Buddhist Scriptures of Paper Relics Excavated from Sum Tolgoi, Mongolia (몽골 숨 톨고이 출토 지류 유물의 과학적 분석 및 보존처리)

  • Bae, Su Bin;Yang, Min Jeong;Kwon, Yun Mi;Yoo, Ji Hyun;Jeong, Hee Won
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.723-737
    • /
    • 2021
  • This study analyzed the composition and structure of materials with Buddhist paper scriptures excavated from architectural sites in 'Sum Tolgoi' of the 17th century and carried out conservation treatment base on the result of the analysis. The scriptures were covered in dust and foreign sub stances, and were so crumpled that it was impossible to identify the form. The damage, loss, and discoloration have been identified. Buddhist scriptures written in Tibetan used indigo and ink sticks on paper as a result of UV-Vis analysis, and ink sticks as black character materials from scriptures written ancient Mongolian. SEM-EDS and Micro-XRF analyses revealed that the outlines were drawn with red lines using a mix of Minium (Pb3O4) and Cinnabar (HgS), or Cinnabar (HgS) alone, and the contents of the scriptures were written with silver paint. Silver chloride (AgCl) and Calcium (Ca) were identified in the silver paint component of the characters, while Calcium and Orpiment (As2S3) were identified in the yellow lines. Concerning the paper ground, Buddhist scriptures written in ancient Mongolian were characterized by herbal plant fiber and bast fiber, and those written in Tibetan, by bast fiber. Radiocarbon dating indicates that the paper for the scriptures was produced between the 15th and 17th centuries. Conservation treatment of the scriptures was carried out based on the experiment on the production of pre-coated paper and how to coat that to prevent the second damage due to the deformation and fragility of the excavated paper. The scriptures were preserved and mounted, and a neutral box was made to identify the contents of the scriptures recorded on both sides after the treatment. This conservation treatment is the result of a study that applied new conservation treatment materials and methods according to the principle of conservation treatment reversibility.

Comparison of General Test Methods of Various Organs on Synthetic Food Colors (여러 기관의 일반시험법에 의한 식용 타르색소의 규격 비교 시험)

  • Shin Dong-Hwa;Kim Yong-Suk;Lee Young-Hwan;Bang Jeong-Ho;Om Ae-Son;Shin Jae-Wook;Lee Tal-Soo;Hong Ki-Hyoung;Park Sung-Kwan;Choi Duck-Jang;Kim Hee-Yun
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.1
    • /
    • pp.64-68
    • /
    • 2005
  • An analytical method of nine synthetic foods colors in Korea, Japan, Joint FAO/WHO Expert Committee of Food Additives (JECFA), and USA were compared. Contents of water insoluble matter in synthetic food colors tested were not different by general test methods of various organs. Contents of chloride and sulfate salts in Food Green No.3, Food Red No.3, Food Blue No.2, and Food Yellow No.4 slightly differed in various methods, and but up to the standard, and general test methods of JECFA and USA needed far more time. For the measurement of arsenic contents in food colors, colorimetric method in Korea and Japan, and silver diethyldithiocarbamate colorimetric method in USA and JECFA were used, but the standards of them were different. Content of heavy metals was up to the standard, but the methods were used colorimetric method in Korea, atomic absorption method in Japan, and both methods in JECFA and USA.

Electrochemical Reduction of Carbon Dioxide Using a Proton Exchange Membrane (양이온 교환막을 이용한 이산화탄소의 전기화학적 환원)

  • Kim, Hak-Yoon;Ahn, Sang Hyun;Hwang, Seung Jun;Yoo, Sung Jong;Han, Jonghee;Kim, Jihyun;Kim, Soo-Kil;Jang, Jong Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.15 no.4
    • /
    • pp.216-221
    • /
    • 2012
  • Electrochemical reduction of carbon dioxide has been widely studied by many scientists and researchers. Recently, the production of formic acid, which is expensive but highly useful liquid material, is receiving a great attention. However, difficulties in the electrochemical reduction process and analyzing methods impede the researches. Therefore, it is important to design an adequate system, develop the reduction process and establish the analyzing methods for carbon dioxide reduction to formic acid. In this study, the production of formic acid through electrochemical reduction of carbon dioxide was performed and concentration of the product has been analyzed. Large scale batch cell with proton exchange membrane was used in the experiment. The electrochemical experiment has been performed using a series of metal catalysts. Linear sweep voltammetry (LSV) and chronoamperometry were performed for carbon dioxide reduction and electrochemical analysis using silver chloride and platinum electrode as a reference electrode and counter electrode, respectively. The concentration of formic acid generated from the reduction was monitored using high performance liquid chromatography (HPLC). The results validate the appropriateness and effectiveness of the designed system and analyzing tool.

Comparison of General Test Methods of Various Organs on Synthetic Food Colors (여러 기관의 일반시험법에 의한 식용 타르색소의 규격 비교 시험)

  • Shin Dong-Hwa;Kim Yong-Suk;Lee Young-Hwan;Bang Jeong-Ho;Om Ae-Son;Shin Jae-Wook;Lee Tal-Soo;Hong Ki-Hyoung;Park Sung-Kwan;Choi Jang-Duck;Kim Hee-Yun
    • Journal of Food Hygiene and Safety
    • /
    • v.19 no.4
    • /
    • pp.171-175
    • /
    • 2004
  • An analytical method of nine synthetic food colors in Korea, Japan, Joint FAO/WHO Expert Committee of Food Additives (JECFA), and USA were compared. Contents of water insoluble matter in synthetic food colors tested were not different by general test methods of various organs. Contents of chloride and sulfate salts in Food Green No.3, Food Red No.3, Food Blue No.2, and Food Yellow No.4 slightly differed in various methods, and but up to the standard, and general test methods of JECFA and USA needed far more time. For the measurement of arsenic contents in food colors, colorimetric method in Korea and Japan, and silver diethyldithiocarbamate colorimetric method in USA and JECFA were used, but the standards of them were different. Content of heavy metals was up to the standard, but the methods were used colorimetric method in Korea, atomic absorption method in Japan, and both methods in JECFA and USA.

Effect of Mesoporous TiO2 in Facilitated Olefin Transport Membranes Containing Ag Nanoparticles (나노입자가 포함된 촉진수송 분리막에서의 메조기공 티타늄산화물의 영향)

  • Kim, Sang Jin;Jung, Jung Pyu;Kim, Dong Jun;Kim, Jong Hak
    • Membrane Journal
    • /
    • v.25 no.5
    • /
    • pp.398-405
    • /
    • 2015
  • Facilitated transport is considered to be a possible solution to simultaneously improve permeability and selectivity, which is challenging in normal polymeric membranes based on solution-diffusion transport only. We investigated the effect of adding mesoporous $TiO_2$ ($m-TiO_2$) upon the separation performance of facilitated olefin transport membranes comprising poly(vinyl pyrrolidone), Ag nanoparticles, and 7,7,8,8-tetracyanoquinodimethane as the polymer matrix, olefin carrier, and electron acceptor, respectively. In particular, $m-TiO_2$ was prepared by means of a facile, mass-producible method using poly(vinyl chloride)-g-poly(oxyethylene methacrylate) graft copolymer as the template. The crystal phase of $m-TiO_2$ consisted of an anatase/rutile mixture, of crystallite size approximately 16 nm as determined by X-ray diffraction. The introduction of $m-TiO_2$ increased the membrane diffusivity, thereby increasing the mixed-gas permeance from 1.6 to 16.0 GPU ($1GPU=10^{-6}cm^3$(STP)/($s{\times}cm^2{\times}cmHg$), and slightly decreased the propylene/propane selectivity from 45 to 37. However, both the mixed-gas permeance and selectivity of the membrane containing $m-TiO_2$ rapidly decreased over time, whereas the membrane without $m-TiO_2$ had more stable long-term performance. This difference might be attributed to specific chemical interactions between $TiO_2$ and Ag nanoparticles, causing Ag to lose activity as an olefin carrier.

Comparision of Signal-Averaged Electrocardiography (SAECG) Determined by Flank Lead System (FLS) and Pyramidal Lead System (PLS) in Healthy Young Adults (정상 성인의 직교유도체제와 피라미드유도체제에 의한 신호 가산 평균심전도의 비교)

  • Jang, Byeong-Ik;Kang, Seung-Ho;Kim, Hyeung-Il;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.179-189
    • /
    • 1993
  • It has recently become possible to record electrical activity originating from abnormally conducting myocardium from the body surface with high - gain amplification and averaging technique. These signals, which result from delayed ventricular activation(late potentials), have been recorded in patients with documented ventricular tachyarrythmia. Several electrode lead system for detecting ventricular late potential were introduced. Pyramidal electrode lead system(PLS) is useful. Also interpretation of SAECG in the young could be of value in detecting those at risk for episodic ventricular tachycardia, but suffer from a lack of data in normal young people. Selection of subjects : For this study, normal healthy young adult volunteers (age: mean 24 years) were recruited from the medical students at Yeungnam University Hospital, Internal Medicine. Twenty fourths male and seventeenths female subjects were selected. All subjects had normal resting ECGs as judged from both the standard 12 channel lead and echocardiography, and none had a history of cardiovascular disease. All subjects were considered to be in good general physical condition. Signal-averaged electrocardiography : In order to obtain low noise recordings with a small number of averaging cycles, all subject ware asked to relax completely in the supine position. Silver/silver chloride electrodes were attached after the skin was cleaned with alcohol, to constitute classic flank lead system(FLS) and pyramidal lead system(PLS). Signals were recorded and processed using a commercially available microprocessor-augmented ECG cart(Marquette Electronics, USA) suitable for portable bedside recording. There was no difference between normal values, determined by FLS and PLS at high pass filtering of 25 Hz and 80 Hz, but significant, difference was found in HFLAD and RMS-40 of 40 Hz(p<0.05). These results will provide a basis for interpretations of SAECG, determined by FLS and PLS in healthy young adults with normal QRS duration.

  • PDF

A Study on the Precise End-Point Detection in Titration by Using the Phase Angle Measurements (위상각 측정에 의한 적정의 정확한 종말점 검출법에 관한 연구)

  • Park, Byung-Bin;Shin, Ho-Sang;Lee, Han-Hyoung
    • Analytical Science and Technology
    • /
    • v.12 no.4
    • /
    • pp.290-298
    • /
    • 1999
  • A study on the application of impedance phase angle for redox titration, acid-base titration, chelate titration and precipitation titration has been carried out. A constant alternating current was passed between two platinum electrodes. One of them was a polarizable micro-electrode of $0.1cm^2$ or $0.026cm^2$ surface area and the other a non-polarizable large electrode of $1cm^2$ surface area dipped in the solution to be titrated. The impedance and the phase angle of the titration cell were measured with lock-in amplifier to obtain well behaved titration curve respectively. In titration of oxalic acid vs. potassium permanganate, the end-point was obtained successfully from the phase angle titration curve. In this experiment, the concentration of 0.0005 M to 0.05 M, the current of $50{\mu}A$ and the frequency of near 50 Hz were used. In titration of phosphoric acid vs. sodium hydroxide, the first end-point was obtained successfully on the optimum experimental condition of 0.001 M concentration, $50{\mu}A$ current and 25~97 Hz frequency. However, the end-point in titration of cupric sulfate vs. disodium-EDTA couldn't be obtained clearly. The end-point was obtained with the out-of-phase impedance curve on the experimental condition of 0.01 M concentration, $100{\mu}A$ current, 5~35 Hz frequency range. In titration of sodium chloride vs. silver nitrate, the end-point was obtained successfully on the experimental condition of 0.1 M concentration, $100{\mu}A$ current and 5~47 Hz frequency range. This study showed that the impedance phase angle was applicable for the detection of the end-points in redox titration curve, acid-base titration curve, chelate titration curve and precipitation titration curve.

  • PDF