• Title/Summary/Keyword: silicone-epoxy

Search Result 56, Processing Time 0.04 seconds

Fabrication and Its Biomedical Application of the pH-ISFET Microprobe (pH-ISFET 마이크로프로브의 製作과 그 生醫學的 應用)

  • Lee, Kwang-Man;Sohn, Byung-Ki
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.11
    • /
    • pp.1335-1341
    • /
    • 1988
  • A pH-ISEFET microprobe for in vivo measurements has been fabricated by combining ISFET (SL-IIS) chip and capillary thin film reference electrode. A two-step TCE oxidation for the gate oxide layer and multilayer encapsulation using silicone rubber and epoxy were specially used for the improvement of the stability and temperature dependence of the ISFET's. The measured sensitivit, response time and temperature dependence of the pH-ISFET microprobes are 50 mV/pH, less than one second, and - 0.01 pH/$^{\circ}$ , respectively. By operating continuously more than 40 days, a long term stability of 0.016 pH/day is obtained. The result of pH monitoring of femoral arterial blood in a rabbit is fairly good agreement with the value of blood gas analysis.

  • PDF

The present state and developing trend of the vacuum/automatic pressure gelating resin-casting technology for electric applications (전기산업분야에서 이용되고 있는 진공/자동가압 겔화 수지-주형기술의 현황과 개발동향)

  • 왕종배;정일형;김재환
    • Electrical & Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.64-72
    • /
    • 1994
  • 본 고는 현재 전기적 응용을 위한 수지 절연물의 진공/가압 수지-주형처리 분야에서 가장 앞선 기술과 연구개발력을 보유하고 있는 스위스의 Ciba-Geigy사와 최신의 진공성형 시스템을 개발, 생산하고 있는 독일의 Hedrich사 및 진공주형/자동가압 성형장비를 생산하는 스위스의 Vogel사 등을 최근에 방문하여 Epoxy, Polyurethane, Polyester 및 Silicone 수지 등의 수지절연시스템을 가지고 구조적으로 기포가 없으며 전기적, 기계적, 열적특성이 매우 우수하고 매끄러운 표면이 요구되는 수지 mold제품을 생산하는데 적용되고 있는 진공 수지-주형처리기술의 현황과 아울러 경화시간을 크게 단축시켜 생산자동화가 가능한 최신의 자동가압겔화(Automatic pressure gelation)/주입몰드공정(Injection molding process)의 특징 및 기술개발현황에 대해 파악한 내용을 소개하고자 한다.

  • PDF

Adhesives and Sealants Used in Machinery and Equipment Assembly, Maintain and Repair

  • Zhai, Haichao;Li, Yinbai;Lin, Xinsong
    • Journal of Adhesion and Interface
    • /
    • v.3 no.1
    • /
    • pp.30-36
    • /
    • 2002
  • In this paper, some idea about the use of Metal and ceramic filled epoxy adhesive, Anaerobic adhesive and RTV silicone in the assembly, maintain and repair of machinery and equipment is given. Many examples which have been successfully used in Chinese industry are introduced: ${\bullet}$ Wear, Abrasion, Corrosion/Erosion Resistance and Metal Rebuilding Worn shafts, Scored Hydraulic Ram, Bearing Housings, Slurry Pumps (Bodies & Impellers), Slide-ways, Heat Exchangers, Cracked Castings and Molds. Leaking Pipes and Tanks. ${\bullet}$ Locking and Retaining Thread, Bearing, Keyways, Bolts, Nuts, Studs, Gears, Collars, Motors. ${\bullet}$ Scaling and Gasketing Flanges, Pipe Joints, Machined surfaces.

  • PDF

Evaluation of different approaches for using a laser scanner in digitization of dental impressions

  • Lee, Wan-Sun;Kim, Woong-Chul;Kim, Hae-Young;Kim, Wook-Tae;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.1
    • /
    • pp.22-29
    • /
    • 2014
  • PURPOSE. This study aimed to investigate the potential clinical application of digitized silicone rubber impressions by comparing the accuracy of zirconia 3-unit fixed partial dentures (FPDs) fabricated from 2 types of data (working model and impression) obtained from a laser scanner. MATERIALS AND METHODS. Ten working models and impressions were prepared with epoxy resin and vinyl polysiloxane, respectively. Based on the data obtained from the laser scanner (D-700; 3Shape A/S, Copenhagen, Denmark), a total of 20 zirconia frameworks were prepared using a dental CAD/CAM system (DentalDesigner; 3shape A/S, Copenhagen, Denmark / Ener-mill, Dentaim, Seoul, Korea). The silicone replicas were sectioned into four pieces to evaluate the framework fit. The replicas were imaged using a digital microscope, and the fit of the reference points (P1, P2, P3, P4, P5, P6, and P7) were measured using the program in the device. Measured discrepancies were divided into 5 categories of gaps (MG, CG, AWG, AOTG, OG). Data were analyzed with Student's t-test ($\alpha$=0.05), repeated measures ANOVA and two-way ANOVA (${\alpha}=0.05$). RESULTS. The mean gap of the zirconia framework prepared from the working models presented a narrower discrepancy than the frameworks fabricated from the impression bodies. The mean of the total gap in premolars (P=.003) and molars (P=.002) exhibited a statistical difference between two groups. CONCLUSION. The mean gap dimensions of each category showed statistically significant difference. Nonetheless, the digitized impression bodies obtained with a laser scanner were applicable to clinical settings, considering the clinically acceptable marginal fit ($120{\mu}m$).

Development of a process to apply uniform pressure to bond CFRP patches to the inner surface of undercut-shaped sheet metal parts (언더컷 형상의 판재 성형품에 보강용 CFRP 패치의 접합을 위한 공정기술 개발)

  • Lee, Hwan-Ju;Jeon, Yong-Jun;Cho, Hoon;Kim, Dong-Earn
    • Design & Manufacturing
    • /
    • v.14 no.4
    • /
    • pp.65-70
    • /
    • 2020
  • Partial reinforcement of sheet metal parts with CFRP patch is a technology that can realize ultra-lightweight body parts while overcoming the high material cost of carbon fiber. Performing these patchworks with highly productive press equipment solves another issue of CFRP: high process costs. The A-pillar is the main body part and has an undercut shape for fastening with other parts such as roof panels and doors. Therefore, it is difficult to bond CFRP patches to the A-pillar with a general press forming tool. In this paper, a flexible system that applies uniform pressure to complex shapes using ceramic particles and silicone rubber is proposed. By benchmarking various A-pillars, a reference model with an undercut shape was designed, and the system was configured to realize a uniform pressure distribution in the model. The ceramic spherical particles failed to realize the uniform distribution of high pressure due to their high hardness and point contact characteristics, which caused damage to the CFRP patch. Compression equipment made of silicone rubber was able to achieve the required pressure level for curing the epoxy. Non-adhesion defects between the metal and the CFRP patch were confirmed in the area where the bending deformation occurred. This defect could be eliminated by optimizing the process conditions suitable for the newly developed flexible system.

Marginal fit evaluation of 3 unit fixed dental prostheses fabricated by rapid prototyping method (쾌속 조형 기술을 이용하여 제작된 3본 고정성 보철물의 적합도 평가)

  • Kim, Ki-Baek;Kim, Jae-Hong;Kim, Woong-Chul;Kim, Hae-Young;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.105-111
    • /
    • 2012
  • Purpose: The purpose this study was to evaluate the marginal fitness of metal copings fabricated using rapid prototyping method and to compare the fitness with copings by conventional method. Then clinical availability of fixed dental prostheses (FDPs) fabricated using rapid prototyping method shall be confirmed based on marginal fitness. Methods: Ten same cases of3 unit FDPs epoxy models (abutment teeth 14 and 16) were manufactured. Each of ten epoxy models were scanned by 3shape D-700 scanner to be designed by experienced technician, and photopolymer 3 unit FDPs were fabricated using rapid prototyping methodand fabricated using Lost wax technique (LW) with same models. Marginal fitness of 3 unit FDPs were measured by silicone replica technique. T-test of independent sample for statistical analysis was executed with SPSS 12.0K for Windows. (${\alpha}$=.05) Results: Significantly higher mean (SD) marginal fitness (P<.000) were observed in the RP group $(95.9(18.0){\mu}m$ compared to the conventionally LW group $(80.1(13.8){\mu}m$. Conclusion: Marginal fitness of LW group showed excellent rather than RP group. However marginal fitness of 3 unit FDPs fabricated by RP method did not get out of clinical allowance value range significantly to allow clinical application.

Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study

  • Lee, Beom-Il;You, Seung-Gyu;You, Seung-Min;Kang, Seen-Young;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.1
    • /
    • pp.24-35
    • /
    • 2021
  • PURPOSE. This study was to evaluate the effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing. MATERIALS AND METHODS. The maxillary right first molar master die was duplicated using a silicone material, while a study die was produced using epoxy resin. Scans of the epoxy resin die were used in combination with CAD software to design a maxillary right first molar interim crown. Based on this design, 24 interim crowns were fabricated with digital light processing. This study examined the trueness and precision of products that were processed with one of the three different postprocessing rinsing times (1 min, 5 min, and 10 min). Trueness was measured by superimposing reference data with scanned data from external, intaglio, and marginal surfaces. Precision was measured by superimposing the scan data within the group. The trueness and precision data were analyzed using Kruskal-Wallis, nonparametric, and post-hoc tests, and were compared using a Mann-Whitney U test with Bonferroni correction (α=.05). RESULTS. The trueness of the external and intaglio surfaces of crowns varied significantly among the different rinsing times (P=.004, P=.003), but there was no statistically significant difference in terms of trueness measurements of the marginal surfaces (P=.605). In terms of precision, statistically significant differences were found among the external, intaglio, and marginal surfaces (P=.001). CONCLUSION. Interim crowns rinsed for 10 minutes showed high accuracy.

Cold resistance investigation of joint materials of electric power XLPE cable (XLPE 전력케이블 접속자재 내한성 평가)

  • Choi, A-Leum;Jung, Sun-Young;Lee, Ji-Hun;Lee, Kyoung-Yong;Kim, Dong-Hun;Kang, Seung-Hun;Kim, Han-Hwa;Chang, Woo-Seog
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1497-1498
    • /
    • 2011
  • 본 논문에서는 -50[$^{\circ}C$]환경에서 케이블 접속함의 극한지역 적용가능 여부를 확인하기 위해 접속함의 주재료인 Etylene Propylene Rubbe(EPR), Silicone Rubber(SR) 및 Epoxy의 물성 및 특성 평가 시험을 진행하였다. 실험방법은 DSC(Differential Scanning Calorimetry)를 사용하여 10[$^{\circ}C$]/min의 승온속도로 각각의 온도구간에서 샘플들의 Tg(Glass Transition Temperature)를 측정하였고, UTM(Universal Testing Machine)으로 -50[$^{\circ}C$]~ 상온에서 인장강도 및 신율을 측정하였다. 본 연구를 동하여, 극한지역의 전력계통 연계 안정성 및 신뢰성 향상을 위한 기초적인 Data-base를 구축했다.

  • PDF

Improvement of surface insulation properties of engineering thermoplastics by using nano/micro composite (나노/마이크로 컴포지트를 이용한 엔지니어링 열가소성 플라스틱의 표면 절연 개선)

  • Jung, Eui-Hwan;Lim, Kee-Joe;Hur, Jun;Jeong, Jong-Hun;Kim, Pyung-Jung;Jeong, Su-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.29-29
    • /
    • 2010
  • Engineering plastics have excellent electrical properties, mechanical strength and various characteristic which include chemical resistance, environmental resistance, weatherability at a wide temperature range. It has good characteristic(light weight, good productivity) as compare with epoxy or porcelain insulators. However, engineering plastics not suited to outdoor insulator because it isn't hydrophobic. Therefore, to over come these critical problems, we improve the surface insulation characteristics of engineering plastic by coating micro-, nano- size inorganic fillers added to RTV-SIR(Room temperature vulcanized-silicone rubber) at this plastic surface. The effect is analyzed through salt-fog test, tracking test. In conclusion, the engineering plastic coated RTV with micro-$Al_2O_3$20[phr], nano-Al(OH)3 1 ~ 3[phr] improved much better than the others.

  • PDF

The Characteristics of Dielectric Breakdown for Epoxy Resin irradiated Electron Beam (전자선 조사된 에폭시 수지의 절연파괴 특성)

  • Hong, Nung-Pyo;Cho, Dong-Chan;Park, Heung-Kyu;So, Byung-Mun;Kim, Wang-Kon;Hong, Jin-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.430-432
    • /
    • 1995
  • In this paper, the electron beam with 1[Mrad], 2[Mrad], 4[Mrad], 8[Mrad] and 24[Mrad] is irradiated for specimen experiments on physical properties which is investigated by FTIR, and dielectric breakdown among the electrical characteristics of specimen are carried out. For the dielectric breakdown experiment, external 60 [Hz] AC voltage is applied to specimen with the rising voltage of 3[kV/cm] until dielectric breakdown occured. We made a breakdown experiment under the temperature condition of 50[$^{\circ}C$], 100[$^{\circ}C$], 150[$^{\circ}C$] in the silicone oils of dynamic viscosity of 100[cSt].

  • PDF