• Title/Summary/Keyword: silicone coating

Search Result 86, Processing Time 0.027 seconds

Microwave Absorbance of Polymer Composites Containing SiC Fibers Coated with Ni-Fe Thin Films

  • Liu, Tian;Kim, Sung-Soo;Choi, Woo-cheal;Yoon, Byungil
    • Journal of Powder Materials
    • /
    • v.25 no.5
    • /
    • pp.375-378
    • /
    • 2018
  • Conductive and dielectric SiC are fabricated using electroless plating of Ni-Fe films on SiC chopped fibers to obtain lightweight and high-strength microwave absorbers. The electroless plating of Ni-Fe films is achieved using a two-step process of surface sensitizing and metal plating. The complex permeability and permittivity are measured for the composite specimens with the metalized SiC chopped fibers dispersed in a silicone rubber matrix. The original non-coated SiC fibers exhibit considerable dielectric losses. The complex permeability spectrum does not change significantly with the Ni-Fe coating. Moreover, dielectric constant is sensitively increased with Ni-Fe coating, owing to the increase of the space charge polarization. The improvements in absorption capability (lower reflection loss and small matching thickness) are evident with Ni-Fe coating on SiC fibers. For the composite SiC fibers coated with Ni-Fe thin films, a -35 dB reflection loss is predicted at 7.6 GHz with a matching thickness of 4 mm.

Properties of UV Curable Coating Film Containing Colloidal Silica Acrylate (콜로이드실리카아크릴레이트를 함유한 자외선 경화형 코팅필름의 특성)

  • Lee, Bong-Woo;Hong, Jin-Who;Bang, Moon-Soo;Oh, Hyung-Sik;Kim, Dae-Jun;Kim, Hyun-Joong
    • Journal of Adhesion and Interface
    • /
    • v.4 no.1
    • /
    • pp.9-17
    • /
    • 2003
  • The UV hard coating materials are attracting more and more attention to modern industry, in terms of the development of low or non solvent coating materials which will contribute to economizing both materials and energy and to reducing pollution. This study was performed in order to invent UV curable coating materials containing colloidal silica which have actual industrial applications. As results of experiments, the oligomers type and the concentration of colloidal silica acrylate oligomer (SAOC) have an influence on various especially, The properties of UV hardening cooling, such as chemical, abrasion resistance and weatherability, were greatly enhanced, the impact properties of coated polycarbonate substrate were improved compared with the noncoated that. The UV cured films containing 30 wt% SAOC obtained showed the best properties.

  • PDF

Change in Molecular Weight Distribution of Diffusible Species on RTV Silicone Rubber Using Solvent Extraction and Recovery Rate of Hydrophobicity (용매추출에 의한 옥외용 RTV 실리콘고무의 분자량 변화와 발수성 회복속도)

  • Lee, Chang-R.;Kim, Dong-H.;Choi, Yong-C.;Kim, Jong-G.;Homma, H.;Izumi, K.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1337-1339
    • /
    • 2001
  • We have investigated the relation between the molecular weight distribution (MWD) of diffusible species and the recovery rate of hydrophobicity of room-temperature vulcanizing (RTV) silicone rubber (SIR) using solvent extraction at various temperatures. It was observed that the extract had a MWD ranging from a few hundreds g/mol to hundreds of thousands g/mol. By measuring the migration of siloxane to the extracted SIR surface through a thin carbon coating, the aspect of migration of diffusible species was observed as a real time plot, and the time constant of the migration was also calculated. According to the time dependence of IR-absorbance, the time constant was increased with the increase of MW of the extracts.

  • PDF

Design and Development of Sputter-evaporation System for Micro-wiring on Medical Catheter (의료용 도뇨관 표면의 도선용 구리 박막 증착을 위한 스퍼터링-열증착 연속공정장비의 설계 및 개발)

  • Chang, Jun-Keun;Chung, Seok
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.3 s.96
    • /
    • pp.62-71
    • /
    • 1999
  • Integrating micro-machined sensors and actuators on the conventional devices with the copper power lines was incompatible to fabricate the mass produced micro electromechanical system (MEMS) devices. To achieve the compatibility of the wiring method between MEMS parts and devices, we developed the three-dimensional sputter-evaporation system that coats micropatterned thin copper films on the surface of the MEMS element. The system consists of a process chamber, two branch chambers, the substrate holder, and a linear-rotary motion feedthrough. Thin copper film was sputtered and evaporated on the biocompatible polymer, Pellethane$^{circed{R}}$ and silicone, catheter that is 2 mm in diameter and 700 mm in length. The metal film coating technique with three-dimensional thin film sputter-evaporation system was developed to apply the power and signal lines on the micro active endoscope. In this paper, we developed the three-dimensional metal film sputter-evaporation system operated on the low temperature for the biopolymeric substrates used in the medical MEMS devices.

  • PDF

Light Efficiency of LED Package with TiO2-nanoparticle-dispersed Encapsulant (TiO2 나노입자가 혼합된 봉지재를 적용한 LED 패키지의 광효율 특성 평가)

  • Lee, Tae-Young;Kim, Kyoung-Ho;Kim, Mi-Song;Ko, Eun-Soo;Chio, Jong-Hyun;Moon, Kyoung-Sik;Kim, Mok-Soon;Yoo, Sehoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.3
    • /
    • pp.31-35
    • /
    • 2014
  • $TiO_2$-nanoparticle-dispersed silicone was applied to a LED package and the light efficiency of the LED package was evaluated in this study. The addition of $TiO_2$ nanoparticles in silicone increased refractive index, which improved the light efficiency of the LED package. The $TiO_2$ nanoparticles were fabricated by hydrothermal synthesis and were dispsersed by a vinyl silane coating treatment. After the silane treatment, the $TiO_2$ nanoparticles dispersed with diameters of 10~40 nm but rod-shape $TiO_2$ nanoparticles with lengths of 100 nm were also observed. The refractive index increased with the $TiO_2$ concentration in silicone, while the transmittance decreased with the $TiO_2$ concentration. The light efficient of the LED package with $TiO_2$+silicone encapsulant was higher than that of the LED package with no $TiO_2$ in silicone encapsulant.

Physical Properties of Covered Stent in Gastric Acid Environment: In Vitro Study (위산 환경에서 피막형 스텐트의 물성 변화)

  • Park, Sung Chul;Park, Nark-Soon;Kim, Dong-Gon;Nah, Jae-Woon;Jeen, Yoon Tae;Cho, Hye Jin;Kim, Eun Sun;Keum, Bora;Seo, Yeon Seok;Lee, Hong Sik;Chun, Hoon Jai;Um, Soon Ho;Kim, Chang Duck;Ryu, Ho Sang
    • Polymer(Korea)
    • /
    • v.38 no.3
    • /
    • pp.351-357
    • /
    • 2014
  • In membrane covered stent, occlusion and fracture from membrane degradation by gastric acid sometimes occurred. Therefore, we investigated the physical properties of membrane covered stent according to its ingredient and concentration in gastric acid environment. Membrane covered stents consisted of silicone and polyurethane with 15%, 18%, 20% concentrations were used. After incubating stents in a condition of pH 1.2, we checked any changes at every 3 weeks for 18 weeks. The changes of membrane surface, radial expansion and recovery force of stent were investigated. Coating thickness increased proportionally to an increase in ingredient concentration. Surface was evenly coated with silicone compared to the case with polyurethane and its homogeneity was excellent in a high concentration. Degradation was much severe in the case of polyurethane. The radial force of silicone was higher than polyurethane, and the decrease of radial and recovery force was higher in the case of polyurethane. In conclusion, high concentration of silicone membrane was more stable than polyurethane in acid environment of in vitro study.

Measurement Method of Broadband Dynamic Characteristics of Viscoelastic Material for Compliant Coating (유연벽면 점탄성 소재의 광대역 동특성 계측 기법)

  • Seoudi, Basel M.;Boiko, Andrey V.;Chun, Ho-Hwan;Lee, In-Won
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.45 no.1
    • /
    • pp.73-80
    • /
    • 2008
  • An improved method to measure the dynamic viscoelastic properties of elastomers is proposed. The method is based on the analysis of forced oscillation of a cylindrical sample loaded with inertial mass. No special equipment or instrumentation other than the ordinary vibration measurement apparatus is required. Typical measurement of the viscoelastic properties of a silicone rubber $Silastic^{(R)}$ S2 were measured over the wide frequency range from 10 Hz to 3 kHz under the action of wide region of deformation from $10^{-4}%$ to 5%. It was shown that modulus of elasticity and loss tangent fall on the single curves when the ratio of load mass to sample mass changed from 1 to 20.

Synthesis and Characterization of Amphiphilic Polyurethanes as Coating Materials for Urinary Catheters (요도용 카테타 도포용 양친성 폴리우레탄의 합성 및 분석)

  • Park Jae-Hyung;Kim Kwang-Meyung;Chung Hes-Son;Kwon Ick-Chan;Bae You-Han;Jeong Seo-Young
    • Polymer(Korea)
    • /
    • v.30 no.3
    • /
    • pp.247-252
    • /
    • 2006
  • The long-term use of indwelling urinary catheters can allow bacterial adhesion to their surfaces, followed by the catheter-associated urinary tract infection. In an attempt to minimize the bacterial adhesion, various amphiphilic polyurethanes (APUs) were synthesized as potential coating materials for urinary catheters. By varying composition of the soft segments such as PEO, PTMO, and PDMS, four different polyurethanes were synthesized. All the APU-coated urinary catheters had the smooth surfaces and showed higher hydrophilicity, compared to the commercial silicone catheters. In particular, the use of APUs with the higher PEG content significantly augmented hydrophilicity and remarkably reduced the total amount of bacteria adhering to the surface. Overall, the APUs prepared in this study provided the promising potential as coating materials for urinary catheters.

Morphological and Chemical Analysis of Various Disposable Acupuncture Needles Used in South Korea

  • Dong Yong, Park;JiYoon, Ahn;Hyeon Jeong, Park;Doo Suk, Lee;Dae-Hyun, Jo;Jonghoon, Kim;Choulmin, Kim;Heebum, Chung;Ji Hye, Hwang
    • Journal of Pharmacopuncture
    • /
    • v.25 no.4
    • /
    • pp.382-389
    • /
    • 2022
  • Objectives: The Korean Industrial Standard (KS) for sterile acupuncture needles was established in 2009 based on research on the quality control of acupuncture needles. We aimed to determine the quality of acupuncture needles available in South Korea in 2021 by examining their surface condition and chemical composition using field-emission scanning electron microscopy (FE-SEM) and energy-dispersive X-ray spectroscopy (EDS). Methods: In South Korea, there are 23 brands of acupuncture needles, and we examined 10-15 needles from each brand, resulting in a total of 285 needles. The microstructures of the needles were assessed by SEM. Using SEM images, we evaluated the acupuncture needle tips for the following defects/aspects: scratches, lumps, detached coating, bent tip, and tip sharpness. EDS was used to determine the chemical composition of the selected acupuncture needles. Results: Overall, 88.4% of 285 needles were found to have at least one type of abnormality. The most frequently observed abnormalities were scratches and dents on the surface (68.1%), followed by detached coating (63.2%), and lumps (61.8%); blunt tips were observed in about 24% of them. Of 252 needles with at least one defect, 86.9% had two or more types of defects. The ratio of the number of needles with any defect to that of needles without any defect varied among brands, ranging from 50% to 100%. Regarding foreign materials, higher proportions of Si and O were observed on the needles, indicating incomplete or detached silicone coating. Conclusion: The quality of acupuncture needles varied among brands, suggesting that further improvements can be made through various inspection methods.

Durability and Evaluation of Plastic Insulator for the Outdoor (옥외용 프라스틱 애자의 내구성과 평가)

  • 조한구;강동필;한동희;김인성
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1993.10a
    • /
    • pp.97-102
    • /
    • 1993
  • The application of epxy composite materials for the outdoor insulating systems has some significant advan-tages compared with conventional inorganic materials, that is low weight in combination with high mechanical strength, small dimensions and design versatility. The paper describes the results of high voltage investigations carried out different aging types of epoxy resin insulator and silicone grease coating. The insulators have been exposed 3000 hours to weather-o-meter and 12 months to outdoor. In this connection, the main study of paper is form the basis of develop-ment of principal technologies of epoxy composites which ard: (1)manufacturing of insulator, (2)high vol-tage testing under dry and wet condition, (3)mechani-cal properties, (4)accelerated weather-ometer test and outdoor exposed, artificial polution.

  • PDF