• 제목/요약/키워드: silicone/acrylic resin

검색결과 35건 처리시간 0.031초

STRAIN CHANGES OF ACRYLIC RESIN SPECIMENS CURED BY THREE CURING CYCLES

  • Kang, In-Ho;Kim, Yung-Soo;Kim, Chang-Whe
    • 대한치과보철학회지
    • /
    • 제40권3호
    • /
    • pp.236-245
    • /
    • 2002
  • The acrylic resin was first introduced as denture base materials in 1937 and it is commonly used for denture base fabrication nowadays. Three different curing cycles (Conventional curing cycle, short curing cycle and long curing cycle) and three commercially available heat-activated acrylic resins (Vertex RS, Lucitone 199 and ProBase Hot) were investigated to find the curing cycle and material that showed the minimum shrinkage of the resin during polymerization process. A brass master mold was fabricated and duplicated by additional silicone impression material. Stone molds were made by pouring of type III dental stone (SILKY-ROCK YELLOW, Whip-Mix, Louisville, Kentucky). It was embedded in the flask. Strain gauge and thermocouple were embedded in the specimen. Strain gauge and thermocouple were connected to signal conditioning amplifier and data was recorded by pre-programmed software. The parameters ESmax (Maximum expansion strain), Sb (Strain measured just before deflasking procedure), Sa (Strain measured just after deflasking procedure) and Sf (Strain measured at the end of the experiment) were measured. ${\Delta}$S was calculated from Sb and Sa (${\Delta}$S=Sb-Sa). In the experiment concerned about materials, the parameters 90-ESmax (Maximum expansion strain measured during early 90 minutes of curing procedure), 180-ESmax (Maximum expansion strain measured from 90 minutes to 180 minutes), Sb, Sa, ${\Delta}$S and Sf were measured and the following conclusions were made. 1. The ESmax value of conventional curing cycle showed the largest value and the 180-ESmax value of Lucitone 199 showed the smallest value. 90-ESmax values showed no significant difference (p<0.05). 2. ${\Delta}$S values of conventional curing cycle showed the positive values. ${\Delta}$S values of short curing cycle and long curing cycle showed the negative values. All three materials cured by conventional curing cycle showed the positive values. 3. The Sf values of long curing cycle and ProBase Hot (cured by conventional curing cycle) showed the smallest values.

초내후성 도료용 실리콘/아크릴수지의 합성 (Synthesis of Silicone/Acrylic Resins for Super-Weatherable Coatings)

  • 김성길;최용호;박홍수
    • 한국응용과학기술학회지
    • /
    • 제16권2호
    • /
    • pp.171-177
    • /
    • 1999
  • The objectives of this study is to investigate the optimum reaction conditions and to identify the product formula in the synthesis of a silicone/acrylic resin that curing in moisture at room temperature. By the addition polymerization of monomers, n-butyl acrylate, methyl methacrylate, n-butyl methacrylate, and 3-methacryloxypropyltrimethoxysilane. a quarter polymer was obtained. Among various initiators investigated in this study, 2.2'-azobisisobutyronitrille was found to be the most suitable initiator. The optimum reaction conditions found in this study are 70 wt% of initial solvent amount, 120 minutes of dropping time, 3 times of initiator addition, $82{\sim}105^{\circ}C$ of reaction temperature, and 8 hrs of reaction time. Also, number average molecular weight of $11700{\sim}33100$ and molecular weight distribution of $1.81{\sim}3.44$ were obtained.

Porcelain laminate veneer의 수복 (Porcelain Laminate Veneer Restoration)

  • 신수연
    • 구강회복응용과학지
    • /
    • 제28권2호
    • /
    • pp.191-200
    • /
    • 2012
  • 도재 라미네이트 비니어(Porcelain laminate veneer, PLV)는 아주 얇은 도재를 치면에 직접 적용시키는 술식으로 전치부 심미 개선을 목적으로 전부피개관 대신에 보존적으로 사용될 수 있다. 그러나 PLV의 성공을 높이기 위해 치질 삭제량을 적절히 조절하는 것은 어려울 뿐만 아니라, 각 치아마다 법랑질 두께가 다양하고 증령에 따라 치관구조 역시 변화하기 때문에 치아 삭제시 주의가 필요하다. 즉 치아 순면을 따라 일관되게 삭제하는 기존의 방법을 이용할 경우 법랑질이 얇아진 부위에서는 상아질이 노출될 위험이 있다. 이를 방지하기 위해 다양한 치아 삭제 방법들이 소개되고 있는데 진단 납형제작을 통한 실리콘 인덱스와 아크릴릭 레진 mock-up을 이용한 방법은 최종적인 수복물의 형태에 기초하여 치아를 삭제할 수 있어 불필요한 법랑질 삭제를 줄이고 상아질 노출을 최소화할 수 있다. 또한 비정상적으로 배열된 치아 삭제시에도 적절한 삭제량 결정이 어려워 삭제량이 과도해지거나 부족해지기 쉬운데, 최종 보철물의 형태를 기준으로 실리콘 인덱스를 제작하면 이를 방지할 수 있다.

실리콘 수식 비닐아세테이트-아크릴 공중합체 수지의 방수성 및 열적 성질 (Water Resistance and Thermal Properties of Resin Based on Silane-modified Vinyl Acetate-Acrylic Emulsion Copolymers)

  • Naghash, Hamid Javaherian
    • 폴리머
    • /
    • 제34권4호
    • /
    • pp.306-312
    • /
    • 2010
  • Triphenylvinylsilane (TPVS) containing vinyl acetate (VAc), butyl acrylate (BA), and Nmethylolacrylamide (NMA) copolymers were prepared by emulsion polymerization. The polymerization was performed at $80^{\circ}C$ in the presence of auxiliary agents and ammonium peroxodisulfate (APS) as the initiator. Sodium dodecyl sulphate (SDS) and Arkupal N-300 were used as anionic and nonionic emulsifiers, respectively. The resulting copolymers were characterized by using Fourier transform infrared spectroscopy (FTIR), gel permeation chromatography (GPC), and dynamic light scattering (DLS). Thermal properties of the copolymers were studied by using thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). The morphology of copolymers was also investigated by scanning electron microscopy (SEM) and then the effects of silicone concentrations on the properties of the TPVS-containing VAc-acrylic emulsion copolymers were discussed. The obtained copolymers have high solid content (50%) and can be used in weather resistant emulsion paints as a binder.

경천사 10층 석탑 구열 및 파손부위 보존처리에 대한 연구 (Study on Conservation Treatment of Cracks and Damaged parts of Kyoung Chun-Sa 10-Story Pagodas)

  • 김사덕;김병호;김창석
    • 보존과학연구
    • /
    • 통권17호
    • /
    • pp.39-47
    • /
    • 1996
  • In this research, many effects were examined by testing of adhesive intensity and accelerated weathering with synthetic resins for the conservation treatment of cracks and damaged parts of Kyound Chun-Sa10-story Pagodas, the National Treasure No. 86.It was tested with two kinds of Epoxy resins, Acrylic, Silicone resin, and five kinds of Acetics vinyl resins, and then which was ensured a successful result with Epoxy resins. According to these consequences, they are determined to treat damaged parts with Epoxy resin.

  • PDF

의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구 (THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS)

  • 장복숙;김창회;김영수
    • 대한치과보철학회지
    • /
    • 제31권2호
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

유리단국부의치(遊離端局部義齒) 사용시(使用時) 지태치(支台齒) 동요(動搖)에 대한 Splingting의 효과(效果)(II) (Effect of splinting on abutment tooth movement when a distal extension partial denture used(II))

  • 정종현
    • 대한치과기공학회지
    • /
    • 제8권1호
    • /
    • pp.85-90
    • /
    • 1986
  • The effect of splinting on aqbutment tooth distal movement was performed in vitro study. An acrylic resin mandibular model with missing 2nd premolars, molars and a removable partial denture framework were constructed. The roots of the canines, 1st premolars and edentulous ridges were coated with silicone rubber. A modified Ney Surveyor was used for vertical load appkication, and abutment tooth distal movement were measured with a dial gauge with four conditions of splinting methods were tested by applying unilateral vertical loadings. The results are follows; 1. The magnitude of abutment tooth distal movement on the non-load side was less 40$\sim$69% than that occurred on the load side. 2. On the load side, reducing effect of splinting on abutment tooth movement in the condition of load side double abutment(30%), non-load side double abutment(10%), double abutments of both sides(40%) was compared with single abutments of both sides. 3. On the non-load side, reducing effect of splinting on abutment tooth movement in the condition of load side double abutment(5%), non-load side double abutment(22%), double abutments of both sides(59%) was compared with single abutments of both sides. 4. The magnitude of abutment tooth distal movement in the condition of double abutments of both sides was less 40$\sim$59% than that in the condition of single abutments of both sides.

  • PDF

침적법과 전기화학법을 이용한 티타늄의 갈바닉 부식에 관한 연구 (A STUDY ON THE GALVANIC CORROSION OF TITANIUM USING THE IMMERSION AND ELECTROCHEMICAL METHOD)

  • 계기성;정재헌;강동완;김병옥;황호길;고영무
    • 대한치과보철학회지
    • /
    • 제33권3호
    • /
    • pp.584-609
    • /
    • 1995
  • The purpose of this study was to evaluate the difference of the galvanic corrosion behaviour of the titanium in contact with gold alloy, silva-palladium alloy, and nickel-chromium alloy using the immersion and electrochemical method. And the effects of galvallit couples between titanium and the dental alloys were assessed for their usefulness as materials for superstructure. The immersion method was performed by measuring the amount of metal elementsreleased by Inductivey coupled plasma emission spectroscopy(ICPES) The specimen of fifteen titanium plates, the five gold alloy, five silver-palladium, five nickel-chromium plates, and twenty acrylic resin plates ware fabricated, and also the specimen of sixty titanium plugs, the thirty gold alloy, thirty silver-palladium, and nickelc-hromium plugs were made. Thereafter, each plug of gold alloy, silver-palladium, and nickel-chromium inserted into the the titanium and acrylic resin plate, and also titanium plug inserted into the acrylic resin plate. The combination specimens uf galvanic couples immersed in 70m1 artificial saliva solution, and also specimens of four type alloy(that is, titanium, gold, silver-palladium and nickel-chromium alloy) plugs were immersed solely in 70m1 artificial sativa solution. The amount of metal elements released was observed during 21 weeks in the interval of each seven week. The electrochemical method was performed using computer-controlled potentiosta(Autostat 251. Sycopel Sicentific Ltd., U.K). The wax patterns(diameter 11.0mm, thickness,in 1.5mm) of four dental casting alloys were casted by centrifugal method and embedded in self-curing acrylic resin to be about $1.0cm^2$ of exposed surface area. Embedded specimens were polished with silicone carbide paper to #2,000, and ultrasonically cleaned. The working electrode is the specimen of four dental casting alloys, the reference electrode is a saturated calmel electrode(SCE) and the ounter electrode is made of platinum plate. In the artificial saliva solution, the potential scanning was carried out starting from-700mV(SCE) TO +1,000mV(SCE) and the scan rate was 75mV/min. Each polarization curve of alloy was recorded automatically on a logrithmic graphic paper by XY recorder. From the polarization curves of each galvanic couple, corrosion potential and corrosion rates, that is, corrosion density were compared and order of corrosion tendency was determined. From the experiments, the following results were obtained : 1. In the case of immersing titanium, gold alloy, silver-palladium alloy, and nickel-chromium alloysolely in the artificial saliva solution(group 1, 2, 3, and 4), the total amount of metal elements released was that group 4 was greater about 2, 3 times than group 3, and about 7.8 times than group 2. In the case of group 1, the amount of titanium released was not found after 8 week(p<0.001). 2. In the case of galvanic couples of titanium in contact with alloy(group 5, 6), the total amount of metal elements released of group 5 and 6 was less than that of group 7, 8, 9, and 10(p<0.05). 3. In the case of galvanic couples of titanium in contact with silver-palladium alloy(group 7, 8), the total amount of metal elements released of group 7 was greater about twice than that of group 5, and that of group 8 was about 14 times than that of group 6(p<0.05). 4. In the case of galvanic couples of titanium in contact with nickel-chromium alloy(group 9, 10), the total amount of metal elements released of group 9 and 10 was greater about 1.8-3.2 times than that of group 7 and 8, and was greater about 4.3~25 times than that of group 5 and 6(p<0.05). 5. In the effect of galvanic corrosion according to the difference of the area ratio of cathode and anode, the total amount of metal elements released was that group 5 was greater about 4 times than group 6, group 8 was greater about twice than group 7, and group 10 was greater about 1.5 times than group 9(p<0.05). 6. In the effect of galvanic corrosion according to the elasped time during 21 week in the interval of each 7 week, the amount of metal elements released was decreased markedly in the case of galvanic couples of the titanium in contact with gold alloy and silver-palladium alloy but the total amount of nickel and beryllium released was not decreased markedly in the case of galvanic couples of the titanium in contact with nickel-chromium alloy(p<0.05). 7. In the case of galvanic couples of titanium in contact with gold alloy, galvanic current was lower than any other galvanic couple. 8. In the case of galvanic couples of titanium in contact with nickel-chromium alloy, galvanic current was highest among other galvanic couples.

  • PDF

ACCURACY OF THE IMPRESSION TECHNIQUE USING THERMOFORMING POLYMETHYL METHACRYLATE TRAY

  • Miyashita, Yuko;Suzuki, Hiroki;Kishi, Masataka;Ko, Sok-Min
    • 대한치과보철학회지
    • /
    • 제45권3호
    • /
    • pp.389-400
    • /
    • 2007
  • Statement of problem. Use of the conventional dental impression procedure is problematic in patients who have difficulty opening their mouth, difficulty breathing through their nose or tendency to gag. Purpose. It is necessary to make individual trays more comfortable for patients during impression taking procedure. It was reported at the KAP Annual Meeting 2001 Seoul that an improved impression technique was suitable for this purpose. In this study, the accuracy of the improved dental impression method for implant was compared with the conventional dental impression method. Material and methods. An oral simulator was made from clear acrylic resin block which had similar form of edentulous ridge. For setting up the standard, five fixtures were installed on it. Study casts were made using two kinds of impression techniques. One was the conventional method that was taken using silicone impression material and an individual resin tray under connection of inter-fixture relation. The other was the improved method in which was the connection of the impression coping and the thermoformed polymethyl methacrylate tray. In addition, two different study casts were made from the improved impression body. The coordinates of the fixture on the study model were measured by three-dimensional coordinate measuring equipment. Then the distances between each fixture were calculated and compared with that of oral simulator. Accuracy of the each impression method was also assessed. Results. The differences of inter-fixture dimension between study casts and simulator in the improved impression technique showed $0.014{\pm}0.016mm$ and $0.017{\pm}0.022mm$, respectively and that of the conventional method was $0.017{\pm}0.014mm$. There was no significant difference between the improved impression technique and conventional method. Conclusion. The improved impression technique is useful for multiple support implants.

A SHEAR BOND STRENGTH OF RESIN CEMENT BONDED TO HUMAN UNCUT ENAMEL, CUT ENAMEL, AND DENTIN IN VITRO

  • Lee Jong-Yeop
    • 대한치과보철학회지
    • /
    • 제41권3호
    • /
    • pp.319-324
    • /
    • 2003
  • Statement of problem. Adhesives in dentistry playa major role in the success of restorative treatments. In the treatment of all ceramic restoration it is needed to find the adequate bond strength between enamel and dentin. Purpose. The purpose of this study was to evaluate shear bond strength of resin cement bonded to extracted human uncut enamel, cut enamel, and dentin in vitro. Material and methods. Ten freshly extracted anterior teeth without any previous restorative treatments were chosen. The extracted teeth were embedded in PMMA cold acrylic in the shape of a cylinder, 25 mm in diameter by 25 mm in height. The bonding system used was as follow: Uni-Etch (32% phosphoric acid), One-Step adhesive, Duolink resin cement. The specimens were acid etched and rinsed with water. Two layers of One-Step adhesive were coated with a disposable brush on the uncut enamel. VIP curing light at $500mV/cm^2$ was used to cure the adhesive. For cut enamel shear bond test, the specimen used for uncut enamel was further reduced approximately $0.3{\sim}0.5mm$ using a laminate preparation diamond bur (0.3 mm in depth). The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit SiC paper and cleaned with distilled water. The bonding procedure on the cut enamel was same as uncut enamel bonding procedure. For dentin bonding test, the specimen used for cut enamel was further reduced approximately $0.5mm{\sim}1.0mm$ using a laminate preparation diamond bur (0.5 mm in depth of diamond cutting). The amount of reduction was evaluated with the silicone mold. The specimens were subsequently treated with 320-grit SiC paper followed by 600-grit silicon carbon paper and cleaned in distilled water. The bonding procedure on the dentin was same as uncut enamel bonding procedure. All samples were mounted and secured on the Ultradent shear bond test sample holder, and Ultradent restricted shear bond testing device was used with Universal Instron machine until fracture. Analysis of variance (ANOVA) test was performed comparing the result at P<0.05. Multiple comparison (Tukey) was used to compare each groups. Result. The result showed that the mean value in shear bond strength of resin cement bonded to uncut enamel, cut enamel and dentin were 27.04 Mpa, 30.25 Mpa and 26.39 Mpa with respect. Conclusion. Within the limitation of this study, the mean value of the shear bond strength of cut enamel was higher than those of uncut enamel or dentin. However there existed no statistical differences between three different human dentition substrates due to increased adhesive characteristics.