• 제목/요약/키워드: silica fume content

검색결과 143건 처리시간 0.044초

잔골재 치환율별 저탄소 무기결합재를 사용한 PVA섬유 모르타르의 유동 및 강도특성 (The Strength and Flowing Properties of PVA Fiber Mortar using the Low-carbon Inorganic Composite according the Replacement Ratio of Fine Aggregate)

  • 박종필;문지환;김규용;이상수;송하영
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2012년도 춘계 학술논문 발표대회
    • /
    • pp.89-90
    • /
    • 2012
  • This study analyzed and compared the flowing and strength properties of mortar depending on the different fine aggregate replacement ratios and whether or not the mixing of PVA fiber was applied. blast furnace slag, red mud, and silica fume that are industrial by-products were used for the analysis. The findings showed that higher replacement level of fine aggregate increased air content while decreasing the table flow. In addition, in case of the compressive strength, Plain mortar and PVA fiber with the replacement ratios of 15% and 30%, respectively showed the greatest strength development.

  • PDF

적산온도에 의한 고강도콘크리트의 압축강도 예측에 관한 실험적 연구 (An Experimental Study on the Compressive Strength Prediction of High-Strength Concrete by Maturity)

  • 길배수;조민형;전진환;남재현
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1996년도 가을 학술발표회 논문집
    • /
    • pp.225-231
    • /
    • 1996
  • Prediction of the early-stage strength of concrete is useful for modernized concrete construction. An experiment was attempted on the high-strength of concrete produced by ordinary portland cement under the curing temperatures of 30, 20, $10^{\cire}C$ and the various mixing proportions such as water-binder ratio of 0.30, 0.35 and silica fume content of 10% by weight of cement. It is the aim of this study to investigare and compare the development of concrete strength with maturity and analyze the application of Maturity as a parameter to correlation estimate test results of concrete. They are statistically analyzed to infer the correlation coefficient between the Maturity and the compressive strength of high-strength concrete.

  • PDF

EVA 개질 고강도 콘크리트의 강도 및 수밀 특성 (Strength and Watertightness Properties of EVA Modified High Strength Concrete)

  • 김영익;성찬용
    • 한국농공학회논문집
    • /
    • 제49권1호
    • /
    • pp.45-54
    • /
    • 2007
  • This study was performed to evaluate strength and watertightness properties of EVA modified high strength concrete in order to improve durability of concrete used in agricultural water utilization facilities that are in constant contact with water. Materials used were cement, coarse and fine aggregates, silica fume, EVA and AE water reducing agent. Tests for the slump, compressive and flexural strengths, absorption ratio and permeability coefficient according to curing condition (water and water+dry curing) and content ratio of EVA were performed. The slump results of EVA modified high strength concrete similarly showed in the content ratio of EVA powder less than 4% and decreased in the content ratio of EVA powder more than 6% compared to that of concrete without EVA powder. The compressive strength of EVA modified high strength concrete decreased with increasing the content ratio of EVA powder. The flexural strength of EVA modified high strength concrete increased with increasing the content ratio of EVA powder in the content ratio of EVA powder ratio less than 4% and had similar or slightly decreased in the content ratio of EVA powder more than 6% compared to that of concrete without EVA powder. The absorption ratio and permeability coefficient of EVA modified high strength concrete decreased with increasing the content ratio of EVA powder in the content ratio of EVA powder less than 4% and slightly increased in the content ratio of EVA powder more than 6%.

Investigations on the tensile strength of high-performance fiber reinforced concrete using statistical methods

  • Ramadoss, P.;Nagamani, K.
    • Computers and Concrete
    • /
    • 제3권6호
    • /
    • pp.389-400
    • /
    • 2006
  • This paper presents the investigations towards developing a better understanding on the contribution of steel fibers on the tensile strength of high-performance fiber reinforced concrete (HPFRC). An extensive experimentation was carried out with w/cm ratios ranging from 0.25 to 0.40 and fiber content ranging from zero to 1.5 percent with an aspect ratio of 80. For 32 concrete mixes, flexural and splitting tensile strengths were determined at 28 days. The influence of fiber content in terms of fiber reinforcing index on the flexural and splitting tensile strengths of HPFRC is presented. Based on the test results, mathematical models were developed using statistical methods to predict 28-day flexural and splitting tensile strengths of HPFRC for a wide range of w/cm ratios. The expressions, being developed with strength ratios and not with absolute values of strengths and are applicable to wide range of w/cm ratio and different sizes/shapes of specimens. Relationship between flexural and splitting tensile strengths has been developed using regression analysis and absolute variation of strength values obtained was within 3.85 percent. To examine the validity of the proposed model, the experimental results of previous researchers were compared with the values predicted by the model.

혼화재를 사용한 콘크리트의 응결 시간에 미치는 초지연제의 영향 (Super Retarding Agent Affecting Setting Time of Concrete Using Mineral Admixture)

  • 전충근;김종;한민철;신동안;오선교;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.643-646
    • /
    • 2005
  • This paper reports the influence of super retarding agent(SRA) on the setting time of concrete incorporating mineral admixture including fly ash(FA), expansive additive(EA), silica fume(SF), blast furnace slag(BS) and blast furnace slag along with fly ash(BS+FA). An increase in SRA resulted in retarding the setting time of control concrete, while the use of mineral admixture led to a delay of setting time markedly, compared with that of control concrete under no SRA content. Meanwhile, An increase in SRA in concrete with mineral admixture exhibited comparable setting delay with control concrete. Furthermore, in case of the use of BS and SF, acceleration of setting time was observed with increase of SRA content. It is considered that proper dosage of SRA of concrete with SF and BS to secure similar setting delay with control concrete require rather larger than that of control concrete. Accordingly, For concrete with mineral admixture, in order to decide the proper dosage of SRA, application of correction factors is needed.

  • PDF

Flexural performance of RC beams incorporating Zinc-rich and epoxy bonding coating layers exposed to fire

  • Tobbala, Dina E.;Rashed, Ahmed S.;Tayeh, Bassam A.
    • Structural Engineering and Mechanics
    • /
    • 제82권2호
    • /
    • pp.163-172
    • /
    • 2022
  • Zinc-rich epoxy (ZRE) is used to overcome corrosion problems in reinforced concrete (RC) beams and coat steel rebars to protect them from humidity and chlorides. An extra coating layer of Sikadur-31 epoxy (SDE) is utilised to increase bond strength because the use of ZRE reduces the bond strength between concrete and steel rebars. However, the low melting point of SDE indicates that concrete specimens are vulnerable to fire. An experimental investigation on flexural performance of RC beams incorporating ZRE-SDE coating of steel rebars that were destroyed by fire is performed in this study. Twenty beams of five concrete mixes with different cementitious contents were tested to compare fire exposure for coated and uncoated rebars of the same beams at room temperature and determine the optimal cementitious content. Scanning electron microscopy (SEM) was also applied to investigate characteristics of fired mixture samples. Results showed that the use of SDE-ZRE at room temperature improves flexural strengths of the five mixes compared with uncoated rebars with percentages ranging from 8.5% to 12.3%. All beams with SDE-ZRE lost approximately 50% of their flexural strength due to firing. Moreover, the mix incorporating SF (silica fume) of 15% and cement content of 400 kg/m3 introduces optimum behaviour compared with other mixes. All results were supported and verified by the SEM analysis and compressive strength of cubic specimens of the same mixes.

초기재령에서 각종 혼합콘크리트의 염소이온 고정화능력에 관한 연구 (A Study on Chloride Binding Capacity of Various Blended Concretes at Early Age)

  • 송하원;이창홍;이근주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권5호
    • /
    • pp.133-142
    • /
    • 2008
  • 본 연구에서는 보통포틀랜드시멘트(OPC: ordinary Portland cement), 플라이애쉬(PFA: pulverised fly ash), 고로슬래그미분말(GGBFS: ground granulated blast furnace slag), 실리카퓸(SF: Silica fume)등의 각종 결합재를 적용한 시멘트 페이스트의 염소이온 고정화능력에 관하여 연구하였다. 각각의 사용 시멘트 페이스트는 40%의 물/결합재로 PFA, GGBFS 및 SF 혼화제의 각기 다른 치환률을 갖도록 하였으며 미리 혼합수내에 결합재 중량당 0.1~0.3%의 염소이온을 배합수내에 혼입 포함시켜 배합되어 제조되었다. 염소이온의 측정은 7일간 양생 후 수분 추출 방법을 이용하여 측정하였다. 실험을 통해 염소이온 고정화 능력이 결합재 종류 및 치환률에 의존하고 있음을 확인하였고, 총 염소이온량의 증가는 염소이온 고정화능력을 제한하여 결론적으로 염소이온 고정화를 감소시키고 있음을 보였다. 본 연구에서 최대 30%의 치환율을 가진 PFA와 60%의 치환률을 가진 GGBFS의 경우는 OPC보다 염소이온고정화 능력이 작았으며, SF의 치환률의 증가는 고정화를 감소시키고 있음을 확인하였으며, 이는 포졸란계 재료의 잠재 수화반응 혹은 공극수의 pH 저하등의 이유로 판단된다. 재령 7일에서의 염소이온의 고정화능력은 염해부식에 대한 저항성으로 나타내어지며, 염분을 혼입한 경우의 고정화능력의 순서는 30%PFA > 10%SF > 60%GGBFS > OPC로 나타났다. 더욱이 염소이온의 고정화 거동은 Langmuir isotherm 및 Freundlich isotherm으로 잘 표현될 수 있음을 보였다.

Predicting sorptivity and freeze-thaw resistance of self-compacting mortar by using deep learning and k-nearest neighbor

  • Turk, Kazim;Kina, Ceren;Tanyildizi, Harun
    • Computers and Concrete
    • /
    • 제30권2호
    • /
    • pp.99-111
    • /
    • 2022
  • In this study, deep learning and k-Nearest Neighbor (kNN) models were used to estimate the sorptivity and freeze-thaw resistance of self-compacting mortars (SCMs) having binary and ternary blends of mineral admixtures. Twenty-five environment-friendly SCMs were designed as binary and ternary blends of fly ash (FA) and silica fume (SF) except for control mixture with only Portland cement (PC). The capillary water absorption and freeze-thaw resistance tests were conducted for 91 days. It was found that the use of SF with FA as ternary blends reduced sorptivity coefficient values compared to the use of FA as binary blends while the presence of FA with SF improved freeze-thaw resistance of SCMs with ternary blends. The input variables used the models for the estimation of sorptivity were defined as PC content, SF content, FA content, sand content, HRWRA, water/cementitious materials (W/C) and freeze-thaw cycles. The input variables used the models for the estimation of sorptivity were selected as PC content, SF content, FA content, sand content, HRWRA, W/C and predefined intervals of the sample in water. The deep learning and k-NN models estimated the durability factor of SCM with 94.43% and 92.55% accuracy and the sorptivity of SCM was estimated with 97.87% and 86.14% accuracy, respectively. This study found that deep learning model estimated the sorptivity and durability factor of SCMs having binary and ternary blends of mineral admixtures higher accuracy than k-NN model.

Corrosion of Steel in Blended Concretes Containing OPC, PFA, GGBS and SF

  • Song, Ha-Won;Lee, Chang-Hong;Lee, Kewn Chu
    • Corrosion Science and Technology
    • /
    • 제8권5호
    • /
    • pp.171-176
    • /
    • 2009
  • The chloride threshold level (CTL) in mixed concrete containing, ordinary Portland cement (OPC), pulverized fuel ash (PFA) ground granulated blast furnace slag (GGBS), and silica fume (SF) is important for study on corrosion of reinforced concrete structures. The CTL is defined as a critical content of chloride at the steel depth of the steel which causes the breakdown of the passive film. The criterion of the CTL represented by total chloride content has been used due to convenience and practicality. In order to demonstrate a relationship between the CTL by total chloride content and the CTL by free chloride content, corrosion test and chloride binding capacity test were carried out. In corrosion test, Mortar specimens were cast using OPC, PFA, GGBS and SF, chlorides were admixed ranging 0.0, 0.2, 0.4, 0.8, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binder. All specimens were cured 28 days, and then the corrosion rate was measured by the Tafel's extrapolation method. In chloride binding capacity, paste specimens were casting using OPC, PFA, GGBS and SF, chlorides were admixed ranging 0.1, 0.2, 0.3, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0% by weight of binders. At 28days, solution mixed with the powder of ground specimens was used to measure binding capacity. All specimens of both experiments were wrapped in polythene film to avoid leaching out of chloride and hydroxyl ions. As a result, the CTL by total chloride content ranged from 0.36-1.44% by weight of binders and the CTL by free chloride content ranged from 0.14-0.96%. Accordingly, the difference was ranging, from 0.22 to 0.48% by weight of binder. The order of difference for binder is OPC > 10% SF > 30% PFA > 60% GGBS.

혼화재 종류 및 섬유 혼입률 변화에 따른 고강도 콘크리트의 내화특성 (Fire Resistance Properties of High Strength Concrete Made with Various Admixture Types and Fiber Content)

  • 장기현;배장춘;김호림;지석원;양성환;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.63-66
    • /
    • 2007
  • This study investigates the fire resistance properties of high strength concrete, around 60MPa class, designed with various admixture types and fiber content. Test showed that the increase of fiber content decreased the fluidity and slightly inclined the air content of fresh concrete. However, the fiber content in concrete did not affect the compressive strength. For the addition of admixture, specimens adding the shrinkage-reducing-agent (SR) indicated the strength value at 70MPa, which is followed by incorporating silica fume (SF) at 66MPa, the combination of expansive admixture (EA) and SR at 63MPa, only EA at 59MPa, blast furnace slag (BS) at 58MPa and fly ash (FA) at 50MPa in an order. After completing the fire test, all specimens adding 0.05vol.% of polypropylene fiber exhibited protection of spatting, except for the specimens incorporating loft of SF and incorporating 20% of SF with only SR and the combination of EP and SRA, respectively. Therefore the most effective result of this study was shown in the specimens incorporating love of FA and 30% of BS and incorporating 20% of SF with 5 % of EA. It is expected that this test results will be crucial references in near future to develope the spatting resistance method of high strength concrete.

  • PDF