• Title/Summary/Keyword: signal tube

Search Result 316, Processing Time 0.032 seconds

Analysis of RPC Probe Signal for S/G Tube in Nuclear Power Plant Considering Defect Factor (결함인자를 고려한 원전 SG세관에서의 RPC 프로브의 신호 해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.53-55
    • /
    • 2005
  • The signals of the eddy current testing(ECT) for the examination of the steam generator(SG) tubes in the nuclear power plant(NPP) determine the existence, size, and kind of defects using the variation of impedance signals when a testing coil, driven by alternating current, passes through the SG tube contains defects. The aim of this paper is building a database of the RPC probe signals on the basis of the sizes variation of defects and frequency variation of probe. In this paper 3-D numerical analysis of the ECT signals using the finite element method is performed. Through this study, it is shown variation of magnitude and phase of impedance according to variation of defect size and frequency. From the result of this paper, we can obtain the information which is useful in defect discrimination of SG tube in nuclear power plant.

  • PDF

A Direct Detection of $CO_2$ in Sealed-off $CO_2$ Discharge Tube by Optoacoustic Effect

  • Kim Sung-Ho;Choi Joong-Gill;Cho Ung-In
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.1
    • /
    • pp.23-25
    • /
    • 1994
  • A simple analytical method that allows direct monitoring of small amount of CO$_2$ in a CO$_2$ discharge tube which utilizes the optoacoustic detection technique is described. The dependence of the optoacoustic signal on the mole fraction of CO$_2$ was shown that the system responded linearly to the amount of CO$_2$ present in the miniature discharge cavity equipped with Cu electrodes. It was also found that fraction of dissociated CO$_2$ varied from 14 to 37% of the initial concentration which depended on the current and the pressure in the tube. This simple and easy detection method has proven to possess the practical advantages over the conventional systems for the study of CO$_2$ laser electrodes.

A study on the Relationship between the Size of Defect and the Intensity of Eddy Current Signal in Heat Exchanging Tube made of STS 304. (Stainless강(鋼) 전열관(傳熱管)에 있어서 과전류(過電流) 신호강도(信號强度)와 결함(缺陷)크기와의 관계에 관한 연구(硏究))

  • Han, E.K.;Eom, H.S.;Park, I.G.;Choi, M.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.6 no.2
    • /
    • pp.7-16
    • /
    • 1987
  • Eddy Current Examination is expected as the effective technique for nondestructive inspection of steam generator and various kinds of heat exchanging tubes made of STS - 304. In Case of E. C. T, a study on the various factors which have an effect on coil impedance is very important to the sensitivity of defect detection and the ratio of signal to noise. Therefore, this study analyzed coil impedance by means of the variational principle, the minimized theory of energy functional and the application of Finite Element Method. Really by using E. C. T, the relationship between the size of defects and the intensity of Eddy Current Signals can be obtained. Signal intensity becomes maximum at certain frequency. This frequency is affected by the characteristics and the position of signal sources.

  • PDF

Changes in the Optogalvanic Signal Amplitude in a Hollow Cathode Discharge

  • Lee, Jun-Hoi;Koo, Kyung-Wan;Lee, Ki-Sik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.212-216
    • /
    • 2009
  • The spatial distribution of the optogalvanic (OG) signal in argon at the 801.489 nm ($1s_5-2p_8$ transition at the metastable level in Paschen notation) was investigated in the radial direction of a hollow cathode discharge tube. The results of this experiment showed that the OG signal amplitude decreases in accordance with the following two conditions; first, the level of discharge current and second, the distance from the cathode dark space. These results can be quantified by analyzing the electron density profile along the discharge regions, which can directly influence the collisional ionization induced by electron impact.

A Study on Field Vibration for Fault Cause Analysis of Glass Insulator on High-speed Railway (고속철도 유리애자 파손원인을 위한 현장 진동 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Bang, Sun-Bae;Kim, Sun-Gu;Ryu, Young-Tae
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.189-190
    • /
    • 2008
  • This study was investigated a possibility of fault of glass insulator due to vibration on high-speed railway. The proper vibration of 1-glass insulator have many frequency band and high amplitude showed in high frequency than low frequency. The proper vibration of strut tube insulator was lowest 170Hz, highest 1.5kHz. The field signal amplitude of viaduct and open route were biggest moment pantograph of high-speed rail. The surface vibration(V3) amplitude of strut tube insulator was biggest. From the FFT analysis of viaduct and open route, the strut tube insulator effect by vertical vibration was big, the frequency was 82.5Hz and 105Hz, respectively. However, in comparison with the proper vibration of strut tube insulator, the resonance was not observed. Although the amplitude of insulator is high, the possibility of fault is low because the glass insulator deterioration by the accumulation of vibration do not happen.

  • PDF

Fabrication and Characteristics of HARP Image Pickup Tube Using a-Se Photoconductive Film (a-Se 광도전막을 이용한 HARP 촬상관의 제작 및 특성)

  • Park, Wug-Dong;Kim, Ki-Wan;Kubota, Misao;Kato, Tsutomu;Suzuki, Shiro;Tanioka, Kenkichi
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.1
    • /
    • pp.17-22
    • /
    • 1998
  • A HARP (high-gain avalanche rushing amorphous photoconductor) image pickup tube using $4{\mu}m$ thick a-Se photoconductive film was fabricated and its characteristics were investigated. When the target voltage was increased more than 360 V, the signal current increases rapidly but the dark current of the tube was suppressed less than 3.2 nA up to the voltage of 490 V And the quantum efficiency of the target was about 4.3 at the electric field of $1.1{\times}10^{6}V/cm$ and the wavelength of 440 nm. Also the amplitude response of the HARP tube was 7.5% at 800 TV lines, and the decay lag was 3.4%.

  • PDF

A study on dynamic characteristics in extension tube and correction of pressure distortion for a S/P type pressure transducer (스파크 플러그형 압력센서에서 연결관로의 동적특성과 압력왜곡의 보상에 관한 연구)

  • 한승국;김승수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.3
    • /
    • pp.32-42
    • /
    • 1991
  • In SI engine research the pressure data in cylinder is the most important fundamental ones leading to engine efficiencies and performances. It is, therefore, necessary to obtain accurate pressure data and yet it is often impossible to install a reliable data producing, flush-mounted type pressure transducer in a cylinder of small and medium size multicylinder SI engines. When flush mounting the transducer is not possible, the spark-plug type pressure transducer is commonly used as an alternative. In this case, the transmission tube of spark-plug type pressure transducer introduces distortions in the pressure signal. Efforts were made to understand the dynamic characteristics of spark-plug pressure transducer by shock tube tests and real engine experiments. In engine experiment the cylinder pressure data were simultaneously obtained by both flush mounted and spark-plug type pressure transducers of certain transmission tube geometry. Those pressure data collected by spark-plug type pressure transducer were tested for correction to flush mounted ones by the application of transfer function. As a result of the calibration the IMEP difference between F/M data and improved S/P data was shown to be corrected about 75-98% from the original ones.

  • PDF

Remote field Eddy Current Technique Development for Gap Measurement of Neighboring Tubes of Nuclear Fuel Channel in Pressurized Heavy Water Reactor (중수로 핵연료채널과 인접관의 간격측정을 위한 원거리장 와전류검사 기술개발)

  • Jung, H.K.;Lee, D.H.;Lee, Y.S.;Huh, H;Cheong, Y.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.164-170
    • /
    • 2004
  • Liquid Injection Nozzle(LIN) tube and Calandria tube(CT) in pressurized Heavy Water Reactor (PHWR) are .ross-aligned horizontally. These neighboring tubes can contact each other due to the sag of the calandria tube resulting from the irradiation creep and thermal creep, and fuel load, etc. In order to judge the contact which might be the safety concern, the remote field eddy current (RFEC) technology is applied for the gap measurement in this paper. LIN can be detected by inserting the RFEC probe into pressure tube (PT) at the crossing point directly. To obtain the optimal conditions of the RFEC inspection, the sensitivity, penetration and noise signals are considered simultaneously. The optimal frequency and coil spacing are 1kHz and 200mm respectively. Possible noises during LIN signal acquisition are caused by lift-off, PT thickness variation, and gap variation between PT and CT. The simulated noise signals were investigated by the Volume Integral Method(VIM). Signal analysis on the voltage plane describes the amplitude and shape of LIN and possible defects at several frequencies. All the RFEC measurements in the laboratory were done in variance with the CT/LIN gap and showed the relationship between the LIN gap and the signal parameters by analyzing the voltage plane signals.

Signal Analysis of Eddy Current Array Probe According to Size Variation of FBH Defects (배열 와전류 프로브의 FBH 결함 크기 변화에 따른 신호 해석)

  • Kim, Ji-Ho;Lim, Geon-Gyu;Lee, Hyang-Beom
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.2
    • /
    • pp.137-144
    • /
    • 2009
  • In this paper, the signal analysis of eddy current array probe was performed to analyze the electromagnetic characteristics with the variation of FBH(flat bottomed hole) defects size on steam generator tube in NPP(nuclear power plants) using the electromagnetic finite element method. To obtain the electromagnetic characteristic of probes, the governing equation was derived from Maxwell's equations, and the individual problem was analyzed by using the 3-dimensional finite element method. For the simulation FBH defects were used. The depth of FBH defects were 20%, 40%, 60%, 80% and 100% of steam generator(SG) tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequencies of 100 kHz, 300 kHz and 400 kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the size variation of depth of FBH defects and operation frequencies. The results in this paper can be helpful when the ECT(eddy current testing) signals from EC array probe are evaluated and analyzed.

Image Evaluation of Projection Method in Chest Radiography (흉부 엑스선 촬영 시 촬영기법에 따른 영상 평가)

  • Ahn, Byung-Ju;Lee, Jun-Haeng
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.3
    • /
    • pp.217-223
    • /
    • 2022
  • In this study, images taken using a grid and images taken using Air Gap Technique were evaluated in X-ray chest radiography. Subjective Evaluation The ROC (Receiver Operating Characteristic) evaluation was evaluated by 5 radiologists who had worked for more than 10 years in the radiology department of a university hospital. Objective evaluation SNR (Signal to noise ratio) was evaluated. As a result of the analysis, the Cronbach Alpha value was 0.714, which was significantly higher. In the Air Gap Technique, the distance between the phantom and the subject was set at 20 cm, and the image was taken with a tube voltage of 100 kVp, a tube current and a recording time of 8 mAs. In the ROC (Receiver Operating Characteristic) evaluation, the highest score was obtained with 18 score and an objective evaluation SNR (signal to noise ratio) of 6,149 scored. Also, in the imaging method using a grid, when the distance between the phantom and the constant receptor is 15 cm apart, and the tube voltage is 110 kVp, the tube current and the recording time are taken at 8 mAs, the ROC evaluation score is 19 and the objective evaluation SNR (Signal to noise ratio) is the highest with 6.622 scored. Therefore, if the Air Gap Technique imaging method is used, which overcomes the shortcomings such as delay in reading, increase in patient's exposure dose, and shortening of mechanical lifespan, as well as re-radiography due to the cut-off phenomenon of the grid that appears using the grid, the It is thought that it will be very helpful for chest imaging, including the case of using a portable X-ray imaging device.