• Title/Summary/Keyword: signal to ratio

Search Result 4,395, Processing Time 0.032 seconds

Analysis of the Relationships Between ESD and DAP, and Image SNR·CNR According to the Frame Change of Cine Imaging in CAG : With Focus on 10 f/s and 15 f/s (심장혈관 조영술에서 씨네(cine)촬영의 프레임변화에 따른 ESD와 DAP 및 영상의 SNR·CNR 관계 분석: 10f/s과 15f/s을 중심으로)

  • Jung, Myo-Young;Seo, Young-Hyun;Song, Jong-Nam;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.669-675
    • /
    • 2018
  • This study aimed to investigate the difference of X-ray exposure by comparing and analyzing entrance surface dose and absorbed dose according to the frame change in coronary angiography using an X-ray machine. Moreover, appropriate frame selection measures for examination, including the effect of frame change on the image quality, were sought by measuring and analyzing the SNR and CNR of the image through image J. The study was conducted on 30 patients (19 males and 11 females) who underwent CAG at this hospital from June 2017 to October 2017. In regard to the patients, their age range was 49-82 years (mean of $65{\pm}9$ years), body weight was 45-91 kg (mean of $67{\pm}8.9kg$), height was 150-179cm (mean of $165.1{\pm}8.9kg$), and BMI was 19.5-30.5(mean of $24.5{\pm}2.9$). For the entrance surface dose and absorbed dose, air kerma value and DAP were obtained and analyzed retrospectively. The SNR and CNR were measured and analyzed through imageJ, and the result values were derived by applying the values to the formula. As for the statistical analyses, the correlations between the entrance surface dose and absorbed dose, and between the SNR and CNR were analyzed by using the SPSS statistical program. The relationship between the entrance surface dose and absorbed dose was not statistically significant for both 10 f/s and 15 f/s (p>0.05). In terms of the relationship between the SNR and CNR, the SNR ($3.374{\pm}2.1297$) and CNR ($0.234{\pm}0.2249$) in 10 f/s were $1.43{\pm}0.4861$ and $0.132{\pm}0.0555$ lower, respectively, than the SNR ($4.929{\pm}2.8532$) and CNR ($0.391{\pm}0.3025$) in 15 f/s, which were not statistically significant (p>0.05). In the correlation analysis, statistically significant results were obtained among the BMI, air kerma, and DAP; between air kerma and DAP; and between SNR and CNR (p<0.001, p<0.001). In conclusion, there was no significant difference between the entrance surface dose and absorbed dose even when the images were taken by changing the frame from 10 f/s to 15 f/s at the time of the coronary angiography. SNR and CNR increased at 15 f/s than at 10 f/s, but they were not statistically significant. Therefore, this study suggests that the concern of the patient and practitioner regarding image quality degradation, as well as the problem of X-ray exposure caused by imaging at 10 f/s and 15 f/s, may be reduced.

Measurement of Regional Cerebral Blood Volume in Normal Rabbits on Perfusion-weighted MR Image (MR 관류강조영상에서 정상 가토의 국소 뇌혈류량 측정)

  • 박병래;예수영;나상옥;김학진;이석홍;전계록
    • Investigative Magnetic Resonance Imaging
    • /
    • v.4 no.2
    • /
    • pp.100-106
    • /
    • 2000
  • Purpose : To evaluate the usefulness of cerebral blood flow measurement applied to perfusion weighted image with short-scan time single shot gradient echo-planar technique in measuring cerebral blood volume(rCBV) of normal rabbits. Materials and methods : With 2.1-3.6 kg weighted rabbits, image is acquired when they are in supine position in children positioner. Perfusion weighted image is acquired to 44 seconds per 1 second successively. After 4 seconds later, Gd-DTPA 2ml are injected into int. jugular vein with 2 ml per second and normal saline is also injected after that. Same technique is applied 2 times per 30 minites in same rabbit. After Image is obtained in two part of cerebral cortex at vertex, convexity, in one of basal ganglia with choosing about $3-5{\textrm{mm}^2}$ areas. Curve of signal intensity changes in time sequence is drawn. After this images are transmitted by PC and software IDL, regional cerebral blood volume is measured with imaging processing program made by us. Results : With 22 of 24 rabbits, satisfactory 1-2 signal intensity versus time curve is made. Cerebral blood capacity and contrast media stay time (ST) is measured in two cerebral cortex and basal ganglia refering in parietal cerebral cortex. Mean focal cerebral blood flow capacity ratio in cortex was $0.97{\pm}0.35$ and in basal ganglia, $0.99{\pm}0.37$, mean contrast media stay time in cortex was $9.83{\pm}1.63$ sec and in basal gaiglia, $9.42{\pm}1.14$ sec, but there was no statistically significant difference between two areas ($\rho$=0.05). Conclusion : In cerebral cortex and basal ganglia, there is no difference in mean focal blood volume and mean contrast stay time. Therefore, PWI is useful in cerebral blood flow and early diagnosis, prognosis of cerebral ischemic disease. Hereafter, it is helpful in analysing cerebral blood flow changes with comparison difference in rCBV between normal tissue and ischemic tissue, and that with DWI finding in infarcted patient.

  • PDF

Investigation of Correlations of Double Inversion Recovery and MR Spectroscopy on Breast MR Imaging (유방 자기공명영상에의 이중반전회복기법과 자기공명분광영상법의 상관관계 연구)

  • Ryu, Jung Kyu;Rhee, Sun Jung;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • Purpose : To evaluate the correlation of lesion-to-normal ratio (LNR) of signal intensity from double inversion recovery MR imaging and total choline-containing compound (tCho) resonance from single voxel MR spectroscopy in breast cancers. Materials and Methods: Between August 2008 and December 2009, 28 patients who were diagnosed as breast cancer and had undergone both double inversion recovery (DIR) MR imaging and MR spectroscopy (MRS) were included in this study. The signal intensities of the lesion (L) and ipsilateral normal breast tissue (N) were measured in region of interest of each breast cancer in DIR and contrast enhance MR image (CE-T1WI) to calculate the LNR value for each technique. MRS was performed using single-voxel MR spectroscopy. The height, width and area of tCho resonance were compared with each LNR of DIR and CE-T1WI. We used Pearson's correlation coefficient(r) for correlation analysis and the significance level was p=0.05. Results: There was no statistically significant correlation between LNR of CE-T1WI and height (r=-0.322, p=0.094), width (r=-0.233, p=0.232) and area (r=-0.309, p=0.109) of MRS tCho. There was no statistically significant correlation between LNR of DIR and height (r=0.067, p=0.735), width (r=-0.287, p=0.139) and area (r=0.012, p=0.953) of MRS tCho, either. The Pearson's correlation coefficient was 0.186 between LNRs of CET1WI and DIR (p=0.344). Conclusion: There was no statistically significant correlation between LNR of DIR and relative amount of tCho resonance of MRS.

Quantitative Assessment and Ligament Traceability of Volume Isotropic Turbo Spin Echo Acquisition (VISTA) Ankle Magnetic Resonance Imaging: Fat Suppression versus without Fat Suppression (발목관절 VISTA 자기공명영상에서 정량평가와 인대의 Traceability: 지방억제 대비 지방억제기법)

  • Cho, Kyung Eun;Yoon, Choon-Sik;Song, Ho-Taek;Lee, Young Han;Lim, Daekeon;Suh, Jin-Suck;Kim, Sungjun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.110-122
    • /
    • 2013
  • Purpose : To compare the image quality and ligament traceability in ankle images obtained using Volume Isotropic Turbo Spin Echo Acquisition (VISTA) MRI with and without fat suppression. Materials and Methods: The signal-to-noise ratios (SNRs) in images from a phantom and from the ankle of a volunteer were compared. Ten ankles from 10 non-symptomatic volunteers were imaged for comparisons of contrast ratio (CR) and ligament traceability. All examinations were performed using VISTA sequences with and without fat suppression on a 3T MRI scanner. The SNRs were obtained from images with subjects and without subjects (noise-only). Contrast ratios from images of the 10 ankles were acquired between fluid and tendon (F-T), F-cartilage (C), F-ligament (L), fat (f)-T, f-C and f-L. Two musculoskeletal radiologists independently scored the traceability of 7 ligaments, in sagittal, axial and coronal images respectively, based on a 4-point scale (1 as not traceable through 4 as clearly traceable). The Wilcoxon signed-rank test was used to compare the CR. Fisher's exact test and Pearson's chi-squared test were used to compare the ligament traceability. Results: The SNRs did not differ significantly between the two sequences except in bone marrow. VISTA SPAIR showed the higher CR only in F-T (p = 0.04), whereas VISTA showed higher CR in f-T (p = 0.005), f-C (p = 0.005) and f-L (p = 0.005). The calcaneofibular ligament traceability with VISTA was superior to that obtained with VISTA SPAIR (p < 0.05) in all planes. Conclusion: VISTA showed significant superiority to VISTA SPAIR in tracing CFL due to the superior CR between fat and ligament.

A Method to Quantify Breast MRI for Predicting Tumor Invasion in Patients with Preoperative Biopsy- Proven Ductal Carcinoma in Situ (DCIS) (유방 자기공명영상법을 이용한 수술 전 관상피내암으로 진단된 환자의 침윤성 유방암을 예측하는 정량적 분석법)

  • Ko, Myung-Su;Kim, Sung Hun;Kang, Bong Joo;Choi, Byung Gil;Song, Byung Joo;Cha, Eun Suk;Kiraly, Atilla Peter;Kim, In Seong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.73-82
    • /
    • 2013
  • Purpose : To determine the quantitative parameters of breast MRI that predict tumor invasion in biopsy-proven DCIS. Materials and Methods: From January 2009 to March 2010, 42 MRI examinations of 41 patients with biopsy-proven DCIS were included. The quantitative parameters, which include the initial percentage enhancement ($E_1$), peak percentage enhancement ($E_{peak}$), time to peak enhancement (TTP), signal enhancement ratio (SER), arterial enhancement fraction (AEF), apparent diffusion coefficient (ADC) value, long diameter and the volume of the lesion, were calculated as parameters that might predict invasion. Univariate and multivariate analyses were used to identify the parameters associated with invasion. Results: Out of 42 lesions, 23 lesions were confirmed to be invasive ductal carcinoma (IDC) and 19 lesions were confirmed to be pure DCIS. Tumor size (p = 0.003; $6.5{\pm}3.2$ cm vs. $3.6{\pm}2.6$ cm, respectively) and SER (p = 0.036; $1.1{\pm}0.3$ vs. $0.9{\pm}0.3$, respectively) showed statistically significant high in IDC. In contrast, E1, Epeak, TTP, ADC, AEF and volume of the lesion were not statistically significant. Tumor size and SER had statistically significant associations with invasion, with an odds ratio of 1.04 and 22.93, respectively. Conclusion: Of quantitative parameters analyzed, SER and the long diameter of the lesion could be specific parameter for predicting invasion in the biopsy-proven DCIS.

Detection of Hepatic Lesion: Comparison of Free-Breathing and Respiratory-Triggered Diffusion-Weighted MR imaging on 1.5-T MR system (국소 간 병변의 발견: 1.5-T 자기공명영상에서의 자유호흡과 호흡유발 확산강조 영상의 비교)

  • Park, Hye-Young;Cho, Hyeon-Je;Kim, Eun-Mi;Hur, Gham;Kim, Yong-Hoon;Lee, Byung-Hoon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.15 no.1
    • /
    • pp.22-31
    • /
    • 2011
  • Purpose : To compare free-breathing and respiratory-triggered diffusion-weighted imaging on 1.5-T MR system in the detection of hepatic lesions. Materials and Methods: This single-institution study was approved by our institutional review board. Forty-seven patients (mean 57.9 year; M:F = 25:22) underwent hepatic MR imaging on 1.5-T MR system using both free-breathing and respiratory-triggered diffusion-weighted imaging (DWI) at a single examination. Two radiologists retrospectively reviewed respiratory-triggered and free-breathing sets (B50, B400, B800 diffusion weighted images and ADC map) in random order with a time interval of 2 weeks. Liver SNR and lesion-to-liver CNR of DWI were calculated measuring ROI. Results : Total of 62 lesions (53 benign, 9 malignant) that included 32 cysts, 13 hemangiomas, 7 hepatocellular carcinomas (HCCs), 5 eosinophilic infiltration, 2 metastases, 1 eosinophilic abscess, focal nodular hyperplasia, and pseudolipoma of Glisson's capsule were reviewed by two reviewers. Though not reaching statistical significance, the overall lesion sensitivities were increased in respiratory-triggered DWI [reviewer1: reviewer2, 47/62(75.81%):45/62(72.58%)] than free-breathing DWI [44/62(70.97%):41/62(66.13%)]. Especially for smaller than 1 cm hepatic lesions, sensitivity of respiratory-triggered DWI [24/30(80%):21/30(70%)] was superior to free-breathing DWI [17/30(56.7%):15/30(50%)]. The diagnostic accuracy measuring the area under the ROC curve (Az value) of free-breathing and respiratory-triggered DWI was not statistically different. Liver SNR and lesion-to-liver CNR of respiratory-triggered DWI ($87.6{\pm}41.4$, $41.2{\pm}62.5$) were higher than free-breathing DWI ($38.8:{\pm}13.6$, $24.8{\pm}36.8$) (p value < 0.001, respectively). Conclusion: Respiratory-triggered diffusion-weighted MR imaging seemed to be better than free-breathing diffusion-weighted MR imaging on 1.5-T MR system for the detection of smaller than 1 cm lesions by providing high SNR and CNR.

Biodistribution of Iodine-131-Iodomisonidazole and Imaging of Tumor Hypoxia in Mice bearing CT-26 Adenocarcinoma (CT-26 선암을 접종한 마우스에서 Iodine-131-Iodomisonidazole의 생체분포 및 종양저산소증의 영상화)

  • Kim, Hye-Won;Kim, Chang-Guhn;Yoon, Kwon-Ha;Kim, Hyun-Jeong;Juhng Seon-Kwan;Roh, Byung-Suk;Yang, David J.;Kim, E.Edmund;Lee, Hyun-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.3
    • /
    • pp.289-297
    • /
    • 1999
  • Purpose: Misonidazole is a radiosensitizer that binds in hypoxic cells. The purpose of this study was to find out the feasibility of I-131-Iodomisonidazole (IMISO) for imaging of tumor hypoxia. Materials and Methods: Tosyl precursor was dissolved in acetonitrile and I-131-NaI was added to synthesize IMISO. Balb/c mice inoculated with CT-26 adenocarcinoma were injected with IMISO. Mice were sacrificed at 1, 2, 4, 24 hr and % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy and MRI, mouse bearing CT-26 adenocarcinoma was administered with IMISO and imaging was performed 4 hr after. Then, mouse body was fixed and microtomized slice was placed on radiographic film for autoradiography Results: %ID/g of tumor was 1.64 (1h), 0.98 (2h), 0.85 (4h) and 0.20 (24h), respectively. At 24h, %ID/g of tumor was higher than that of all other tissues except thyroid. Tumor to muscle ratio increased with time and tumor to blood ratio also increased with time and reached 1.53 at 24 hr. On autoradiogram, tumor was well visualized as an increased activity in central hypoxic area of the tumor which corresponds to the area of high signal intensity on T2-weighted MR image. On scintigraphy, tumor uptake was visualized. Conclusion: This results suggest that IMISO may have a potential for tumor hypoxia imaging in mouse model. However, further study is needed to improve it's localization in tumor tissue and to achieve acceptable images of tumor hypoxia.

  • PDF

Utility Evaluation of Supportive Devices for Interventional Lower Extremity Angiography (인터벤션 하지 혈관조영검사를 위한 보조기구의 유용성 평가)

  • Kong, Chang gi;Song, Jong Nam;Jeong, Moon Taek;Han, Jae Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.4
    • /
    • pp.613-621
    • /
    • 2019
  • The purpose of this study is to evaluate the effectiveness of supportive devices which are for minimizing the patient's movement during lower extremity angiography and to verify image quality of phantom by analyzing of Mask image, DSA image and Roadmap image into SNR and CNR. As a result of comparing SNR with CNR of mask image obtained by DSA technique using the phantom alone and phantom placed on the supportive devices, there was no significant difference between about 0~0.06 for SNR and about 0~0.003 for CNR. The study showed about 0.11~0.35 for SNR and 0.016~0.031 for CNR of DSA imaging by DSA technique about only water phantom of the blood vessel model and the water phantom placed on the device. Analyzing SNR and CNR of Roadmap technique about water phantom on the auxiliary device (hardboard paper, pomax, polycarbonate, acrylic) and water phantom alone, there was no significant difference between 0.02~0.05 for SNR and 0.002~0.004 for CNR. In conclusion, there was no significant difference on image quality by using supportive devices made by hardboard paper, pomax, polycarbonate or acryl regardless of whether using supportive devices or not. Supportive devices to minimize of the patient's movement may reduce the total amount of contrast, exam-time, radiation exposure and eliminate risk factors during angiogram. Supportive devices made by hardboard paper can be applied easily during angiogram due to advantages of reasonable price and simple processing. It is considered that will be useful to consider cost efficiency and types of materials and their properties in accordance with purpose and method of the study when the operator makes and uses supportive devices.

Seismic Imaging of a Tidal Flat: A Case Study for the Mineopo Area (조간대(갯벌)에서의 탄성파 탐사: 민어포 지역의 사례)

  • Jou, Hyeong-Tae;Kim, Han-Joon;Lee, Gwang-Hoon;Lee, Sang-Hoon;Jung, Baek-Hoon;Cho, Hyun-Moo;Jang, Nam-Do
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.3
    • /
    • pp.197-203
    • /
    • 2008
  • A shallow high-resolution seismic reflection survey was carried out at the Mineopo tidal flat on the western coast of Korea. The purpose of the survey was to investigate shallow sedimentary structure of the tidal flat associated with the recent sea level change. A total of 795 shots were generated at 1 m interval from a 5-kg hammer source and recorded on 48 channels of 100 Hz geophones along two mutually perpendicular profiles. The water-saturated ground condition resulted in suppressed ground rolls by significantly decreasing rigidity. In addition, seismic velocities over 1500 m/s provided easy segregation of reflected arrivals from lower velocity noise. As a consequence, seismic sections from the study area show significantly higher resolution and signal to noise ratio than conventional land seismic sections. The tidal flat consists of 5 sedimentary sequences above acoustic basement. The seismic sections reveal the continuous structure of the tidal flat formed in association with sea level rise during the Holocene.

The study of PbO's sintering effect for high efficiency x-ray detection sensor (고효율 방사선 검출 센서를 위한 PbO 박막의 소결효과에 대한 연구)

  • Jung, Suk-Hee;Kim, Yoon-Suk;Kim, Young-Bin;Kim, Min-Woo;Oh, Kyung-Min;Yun, Min-Seok;Nam, Sang-Hee;Park, Ji-Koon
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.3
    • /
    • pp.37-40
    • /
    • 2009
  • In this study, we made a high efficiency x-ray detecting sensor using the lead oxide(PbO) that are used in direct method of x-ray detector. PbO with nano size particles is produced by sol-gel method for high efficiency. The produced PbO with nano size is deposited on ITO(Induim Tin Oxide) glass in several temperature using the PIB(particle-in-binder) method. The thickness of the deposited PbO is about $200{\mu}m$. Through the measurement of dark current, sensitivity and SNR(Signal To Noise Ratio), an electrical properties of the produced PbO film are analyzed. Therefore, we show that an electrical properties are changed according to a temperature and that the PbO film that was treated at $500^{\circ}C$ in O2 atmosphere is the most high efficiency x-ray detecting sensor.

  • PDF