• Title/Summary/Keyword: signal sequence

Search Result 1,264, Processing Time 0.039 seconds

Intramedullary Spinal Cord Lipoma Extending from the Cervicomedullary Junction to the Upper Thoracic Cord

  • Lee, Deok-Gu;Yoon, Seok-Mann;Shim, Jai-Joon;Bae, Hack-Gun
    • Journal of Korean Neurosurgical Society
    • /
    • v.38 no.1
    • /
    • pp.71-73
    • /
    • 2005
  • A case of intramedullary spinal cord lipoma is presented. A one month-old male infant presented with irritability and weakness on his upper extremities. A magnetic resonance[MR] image of the cervical spine demonstrated a well defined, high signal intensity lesion on both T1 and T2-weighted MR images and suppression on the fat saturation sequence. The tumor mass extended from the foramen magnum to T2 vertebra level. Ventral displacement of the spinal cord with kinking of the cervico-medullary junction was evident on the T2-weighted sagittal image. Partial resection of the tumor mass through laminoplastic laminotomy from C1 to T2 resulted in improved motor weakness on his upper extremities.

The Receptor-Ligand Interaction Revealed by a Homology Modelling of the Receptor Binding Domain of Human Thrombopoietin

  • Song, Jin-Soo;Park, Heung-Rok;Hong, Hyo-Jeong;Yu, Myeong-Hee;Ryu, Seong-Eon
    • Proceedings of the Korean Biophysical Society Conference
    • /
    • 1997.07a
    • /
    • pp.43-43
    • /
    • 1997
  • Platelet production in blood is regulated by a lineage specific humoral factor called thrombopoietin (TPO). The amino terminal domain of TPO (TPO-N) has a sequence homology to erythropoietin (EPO) and is responsible for the signal transduction mediated by the TPO receptor, c-mpl.(omitted)

  • PDF

Dimming Control of LED Light Using Pulse Frequency Modulation in Visible Light Communication

  • Lee, Seong-Ho
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.4
    • /
    • pp.269-275
    • /
    • 2021
  • Light-emitting diodes (LEDs) are modulated using a square wave pulse sequence for flicker prevention and dimming control in visible light communication (VLC). In a VLC transmitter, the high and low bits of the non-return-to-zero (NRZ) data are converted to two square waves of different frequencies, which continue for a finite time defined by the fill ratio in an NRZ bit time. As the average optical power was kept constant and independent of data transmission, the LED was flicker-free. Dimming control is carried out by changing the fill ratio of the square wave in the NRZ bit time. In the experiments, the illumination of the LED light was controlled in the range of approximately 19.2% to 96.2% of the continuous square wave modulated LED light. In the VLC receiver, a high-pass filter combined with a latch circuit was used to recover the transmitted signal while preventing noise interference from adjacent lighting lamps.

Nuclear Effectors in Plant Pathogenic Fungi

  • Surajit De Mandal;Junhyun Jeon
    • Mycobiology
    • /
    • v.50 no.5
    • /
    • pp.259-268
    • /
    • 2022
  • The nuclear import of proteins is a fundamental process in the eukaryotes including plant. It has become evident that such basic process is exploited by nuclear effectors that contain nuclear localization signal (NLS) and are secreted into host cells by fungal pathogens of plants. However, only a handful of nuclear effectors have been known and characterized to date. Here, we first summarize the types of NLSs and prediction tools available, and then delineate examples of fungal nuclear effectors and their roles in pathogenesis. Based on the knowledge on NLSs and what has been gleaned from the known nuclear effectors, we point out the gaps in our understanding of fungal nuclear effectors that need to be filled in the future researches.

A Band Stop Filter for Pre-Processing Image Sequences

  • Cho, Nam-Ik;Lee, Sang-Uk
    • Journal of Electrical Engineering and information Science
    • /
    • v.1 no.1
    • /
    • pp.70-76
    • /
    • 1996
  • In this paper, we have proposed a band stop filter (BSF) for pre-processing of image sequences before encoding. By pixel-wise temporal filtering of the image sequences using the BSF, the bandwidth and noise of the signal are reduced, while preserving the image quality in view of human visual perceptions. As a result, when compared to the original image sequences, te pre-filtered image sequence requires lower bit-rates for encoding, while there is not much degradation in quality. Also, it has been shown that the proposed BSF causes less smearing and blurring than the conventional recursive low pass filter for bandwidth and noise reductions.

  • PDF

Performance Analysis of MC-DS/CDMA System with Phase Error and Hybrid SC/MRC-(2/3) Diversity (위상 에러와 하이브리드 SC/MRC-(2/3)기법을 고려한 MC-DS/CDMA 시스템의 성능 분석)

  • Kim Won-Sub;Park Jin-Soo
    • The KIPS Transactions:PartC
    • /
    • v.11C no.6 s.95
    • /
    • pp.835-842
    • /
    • 2004
  • In this paper, we have analyzed the MC-DS/CDMA system with input signal synchronized completely through adjustment of the gain in the PLL loop, by using the hybrid SC/MRC-(2/3) technique, which is said to one of the optimal diversity techniques under the multi-path fading environment, assuming that phase error is defined to the phase difference between the received signal from the multi-path and the reference signal in the PLL of the receiver. Also, assuming that the regarded radio channel model for the mobile communication is subject to the Nakagami-m fading channel, we have developed the expressions and performed the simulation under the consideration of various factor, in the MC/DS-CDMA system with the hybrid SC.MRC-(2/3) diversity method, such as the Nakagami fading index(m), $the\;number\;of\;paths\;(L_p),$ the number of hybrid SC.MRC-(2/3) $diversity\;branches\;(L,\;L_c),$ the number of users (K), the number of subcarriers (U), and the gain in the PLL loop. As a result of the simulation, it has been confirmed that the performance improvement of the system can be achieved by adjusting properly the PLL loop in order for the MC/DS-CDMA system with the hybrid SC/MRC-(2/3) diversity method to receive a fully synchronized signal. And the value of the gain in the PLL loop should exceed 7dB in order for the system to receive the signal with prefect synchronization, even though there might be a slight difference according to the values of the fading index and the spread processing gain of the subcarrier.

Clinical diagnostic study on Physiological Signal data measured on 31 cases of lumbago with EAV(Electro-puncture According to Voll) (요통환자(腰痛患者) 31례(例)에 대(對)한 EAV측정치(測定値)의 진단적(診斷的) 고찰(考察))

  • Han, Sang-Gyun;Ha, Chi-Hong;Kim, Jae-Hong;Cho, Myung-Rae;Bae, Eun-Jeong;Shin, Young-Il;Yang, Ki-Yong;Hwang, Kyu-Jung;Lee, Byung-Ryul
    • Journal of Acupuncture Research
    • /
    • v.19 no.1
    • /
    • pp.101-110
    • /
    • 2002
  • Background and Purpose : Most diagnostic method for lumbago were invasive and complex. So we need to simplify and objectify diagnostic method for lumbago. Some study with EAV which is one of Physiological Signal Measuring Instruments, report significantly result as objective diagnostic method for other clinical symptom. By using EAV, we have obtained some physiological signal data from meridian-acupoints of 31 lumbago cases. Objective and Methods : This study researched into the clinical statistics for 31 case who ware in lumbago, and they ware treated with oriental medical care at the Dong-shin university oriental hospital during 6 month from June 1 2001 to November 10 2001. The data were analyzed and interpreted to compare with traditional differentiation of symptom-complexes, then further evaluated as the Five Evolutive Phases to make them differentiated. The EAV valus of Five Evolutive Phases were identified with the sequence of wood(木), fire(火), earth(土)steel(金), water(水). Results and Conclusion : These values of physiological signal were identical with standard differentiation of symptom-complexes of lumbago which is the main cause of deficiency of Qi and blood of the kidney and bladder. Among Five Evolutive Phases, Earth and wood values were increased, steel, fire and water were decreased significantly. This data imply the possibility of somewhat generalization from measuring instruments.

  • PDF

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Chromosome Analysis Using GISH and FISH of Interspecific Hybrids between Allium cepa L. and A. fistulosum L. (GISH와 FISH를 이용한 양파와 파간 종간교잡계통의 염색체 분석)

  • Kim, Cheol-Woo;Lee, Eul-Tai;Kim, Hwa-young;Choi, In-Hu;Bang, Jin-Ki;Koo, Dal-Hoe;Bang, Jae-Wook
    • Korean Journal of Breeding Science
    • /
    • v.41 no.4
    • /
    • pp.468-473
    • /
    • 2009
  • Fluorescence in situ hybridization (FISH) and genomic in situ hybridization (GISH) were used for chromosome analysis of hybrids (2n=16) between onion (Allium cepa L., 2n=2X=16) and welsh onion (A. fistulosum L., 2n=2X=16). 5S rDNA, 45S rDNA, and tandemly repeated DNA (TSD) sequence were used as probes for FISH analysis. A. fistulosum specific DNA probe of telomeric repeats and A. fistulosum DNA were used for GISH analysis. In the analysis of meiotic chromosome GISH revealed that hybrids have 7 bivalants and 2 univalents chromosome and 2 univalents were derived from A. fistulosum chromosomes. In somatic chromosomes of hybrid each 8 chromosomes were derived from A. cepa and A. fistulosum, respectively. FISH signal of 45S rDNA probe in A. fistulosum was detected at secondary constriction of chromosomes, while FISH signal in A. cepa was observed in both secondary constriction and telomere of chromosomes. TDS signals in A. fistulosum chromosomes were detected at all subtelomeric of 8 chromosomes and also in 2 pericentromeric of the chromosomes, whereas TDS signals in A. cepa were observed only in subtelomeric in all chromosomes. The pattern of TDS signal in hybrid chromosomes was similar to those of A. fistulosum chromosomes.

Cell ID Detection Schemes Using PSS/SSS for 5G NR System (5G NR 시스템에서 PSS/SSS를 이용한 Cell ID 검출 방법)

  • Ahn, Haesung;Kim, Hyeongseok;Cha, Eunyoung;Kim, Jeongchang
    • Journal of Broadcast Engineering
    • /
    • v.25 no.6
    • /
    • pp.870-881
    • /
    • 2020
  • This paper presents cell ID (cell identity) detection schemes using PSS/SSS (primary synchronization signal/secondary synchronization signal) for 5G NR (new radio) system and evaluates the detection performance. In this paper, we consider two cell ID detection schemes, i.e. two-stage detection and joint detection schemes. The two-stage detection scheme consists of two stages which estimate a channel gain between a transmitter and receiver and detect the PSS and SSS sequences. The joint detection scheme jointly detects the PSS and SSS sequences. In addition, this paper presents coherent and non-coherent combining schemes. The coherent scheme calculates the correlation value for the total length of the given PSS and SSS sequences, and the non-coherent combining scheme calculates the correlation within each group by dividing the total length of the sequence into several groups and then combines them non-coherently. For the detection schemes considered in this paper, the detection error rates of PSS, SSS and overall cell ID are evaluated and compared through computer simulations. The simulation results show that the joint detection scheme outperforms the two-stage detection scheme for both coherent and non-coherent combining schemes, but the two-stage detection scheme can greatly reduce the computational complexity compared to the joint detection scheme. In addition, the non-coherent combining detection scheme shows better performance under the additive white Gaussian noise (AWGN), fixed, and mobile environments.