• Title/Summary/Keyword: signal detector

Search Result 1,005, Processing Time 0.032 seconds

Analysis of fluctuations in ex-core neutron detector signal in Krško NPP during an earthquake

  • Tanja Goricanec;Andrej Kavcic;Marjan Kromar;Luka Snoj
    • Nuclear Engineering and Technology
    • /
    • v.56 no.2
    • /
    • pp.575-600
    • /
    • 2024
  • During an earthquake on December 29th 2020, the Krško NPP automatically shutdown due to the trigger of the negative neutron flux rate signal on the power range nuclear instrumentation. From the time course of the detector signal, it can be concluded that the fluctuation in the detector signal may have been caused by the mechanical movement of the ex-core neutron detectors or the pressure vessel components rather than the actual change in reactor power. The objective of the analysis was to evaluate the sensitivity of the neutron flux at the ex-core detector position, if the detector is moved in the radial or axial direction. In addition, the effect of the core barrel movement and core inside the baffle movement in the radial direction were analysed. The analysis is complemented by the calculation of the thermal and total neutron flux gradient in radial, axial and azimuthal directions. The Monte Carlo particle transport code MCNP was used to study the changes in the response of the ex-core detector for the above-mentioned scenarios. Power and intermediate-range detectors were analysed separately, because they are designed differently, positioned at different locations, and have different response characteristics. It was found that the movement of the power range ex-core detector has a negligible effect on the value of the thermal neutron flux in the active part of the detector. However, the radial movement of the intermediate-range detector by 5 cm results in 7%-8% change in the thermal neutron flux in the active part of the intermediate-range detector. The analysis continued with an evaluation of the effects of moving the entire core barrel on the ex-core detector response. It was estimated that the 2 mm core barrel radial oscillation results in ~4% deviation in the power and intermediate-range detector signal. The movement of the reactor core inside baffle can contribute ~6% deviation in the ex-core neutron detector signal. The analysis showed that the mechanical movement of ex-core neutron detectors cannot explain the fluctuations in the ex-core detector signal. However, combined core barrel and reactor core inside baffle oscillations could be a probable reason for the observed fluctuations in the ex-core detector signal during an earthquake.

RF Power Detector for Location Sensing

  • Kim, Myung-Sik;Kubo, Takashi;Chong, Nak-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1771-1774
    • /
    • 2005
  • Recently, RFID has become popular in the field of remote sensing applications. Location awareness is one of the most important keys to deploying RFID for advanced object tracking. Generally, multiple reference RF stations or additional sensors are used for the location sensing with RFID, but, particularly in indoor environments, spatial layout and cost problems limit the applicability of those approaches. In this paper, we propose a novel method for location sensing with active RFID systems not requiring the need for reference stations or additional sensors. The system triangulates the position of RF signal source using the signal pattern of the loop antenna connected to the power detector. The power detector consists of a signal strength detector and a signal analysis unit. The signal analysis unit indicates the signal strength and serial number using the signal from the strength detector, and provides the direction of the signal to the application target. We designed three different signal analysis units depending on the threshold type. The developed system can sense the direction to the transponder located over 10 m away within the maximum error of $5^{\circ}$. It falls within a reasonable range in our normal office environment.

  • PDF

DSP based Narrow-Band Signal Power Detector for Tracking Control of Satellite Antenna (위성통신안테나 추적제어를 위한 DSP 기반의 협대역신호 전력 검출기)

  • Kim, Won-Ho
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.7 no.4
    • /
    • pp.184-188
    • /
    • 2006
  • This paper presents DSP based narrow band satellite communication signal power detector for tracking control of mobile satellite antenna system. An analog filter based conventional power detector has poor performance due to frequency drift of carrier. Also, it is very difficult to change an analog filter bandwidth according to changed bandwidth of transmitted signal. To solve these difficulties, we proposed DSP based signal power detector, which is easy to change bandwidth of filter and to match shifted frequency of carrier. The proposed signal power detector consists of a FFT function to measure frequency drift of carrier, a programmable filter bank function to limit of received signal bandwidth and a power calculation function to measure power of filtered signal in 12-bit linear scale. Test results of implemented signal power detector, based on TMS320C5402 DSP, showed that it satisfied required functions and performances and properly operated.

  • PDF

Monte-Carlo Simulation on Properties of X-ray Detector with Multi-layer Structure (몬테카를로 시뮬레이션을 통한 다층 구조 엑스선 검출기의 특성 평가)

  • Shin, Jung-Wook;Park, Ji-Koon;Seok, Dea-Woo;Lee, Chae-Hoon;Kim, Jea-Hyung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.427-430
    • /
    • 2003
  • The properties of digital X-ray detectors depend on the absorption extent of X-rays, the generated signal of each X-ray photon and the distribution of the generated signal between pixels. In digital X-ray detector with single layer, signal is generated by X-ray photon captured in photoconductor. In X-ray detector with multi structure that scintillator formed above the top of photoconductor, signal is generated both by X-ray photon captured each in scintillator and photoconductor. X-ray detector with multi structure is generated more signal than single layer detector. In this paper, we simulated absorption fraction of X-ray detector with multi-layer using Monte Carlo program. The results compared with single-layer detector to be formed scinillator or photoconductor.

  • PDF

Performance Comparisons of some nonparametric detectors (몇가지 비모수 검파기의 성능 비교)

  • 김홍길;송익호;장태주;배진수
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1996.06a
    • /
    • pp.9-15
    • /
    • 1996
  • In this paper, we propose a new detector based on the median-shift sign. We call it the median-shift sign (MSS) detector, which is an extension of the classical sign detector. We first analyze the problem of detecting a dc signal in noise of known probability density function (pdf). The MSS detector with the optimum median-shift value, the optimum MSS detector, performs better than the sign detector in Gaussian noise: it has the best performance among the detectors compared in Laplacian and Cauchy noise. It is shown that the MSS detectors with constant median-shift values are nearly equal to the optimum MSS detector. We also analyze the problem of detecting a dc signal when only partial information is available on the noise. The MSS detectors with constant median-shift values are almost equal to the sign detector in Gaussian noise: they perform better than the sign and Wilcoxon detectors for most signal ranges in Laplacian and Cauchy noise.

  • PDF

Linear-Quadratic Detectors for Spectrum Sensing

  • Biglieri, Ezio;Lops, Marco
    • Journal of Communications and Networks
    • /
    • v.16 no.5
    • /
    • pp.485-492
    • /
    • 2014
  • Spectrum sensing for cognitive-radio applications may use a matched-filter detector (in the presence of full knowledge of the signal that may be transmitted by the primary user) or an energy detector (when that knowledge is missing). An intermediate situation occurs when the primary signal is imperfectly known, in which case we advocate the use of a linear-quadratic detector. We show how this detector can be designed by maximizing its deflection, and, using moment-bound theory, we examine its robustness to the variations of the actual probability distribution of the inaccurately known primary signal.

Signal Shapes from a Closed-ended Coaxial HPGe Detector

  • Park, H. D.
    • Nuclear Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.451-458
    • /
    • 1997
  • Signal shapes from a closed-ended coaxial HPGe detector are investigated by numerical methods. The detector used in this study has a volume of 72 ㎤ with relative efficiency of 15%. The electric field and potential distributions in the detector are determined by solving the Poisson equation at the depletion and operating bias. Hence the time dependent signal shapes induced on the electrode are obtained from the energy balance consideration and tv solving the equation of motion for the charge carriers. For various initial positions of a charge carrier pair, the collection times of induced charge vary in the range of 70 - 404 nsec.

  • PDF

Study for improvement of zero-cross detector of control element drive mechanism control system in PWR (경수로 제어봉구동장치제어계통의 영점위상탐지기 성능개선에 관한 연구)

  • 김병문;이병주;한상준
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.609-611
    • /
    • 1996
  • Zero-Cross Detector makes pilot signal to control the power to CEDM(Control Element Drive Mechanism). Existing Zero-Cross Detectors has had a problem which can cause unexpected reactor trip resulted from fluctuating frequency of input signal coming from M/G Set. The existing Zero-Cross Detector can't work properly when power frequency is varying because it was designed to work under stable M/G Set operation, and produces wrong pilot signal and output voltage. In this report the Zero-Cross Detector is improved to resolve voltage fluctuating problem by using new devices such as digital noise filtering circuit, variable cycle compensator and alarm circuit. And through the performance verification it shows that new circuit is better than old one. If suggested detector is applied to plant, it is possible to use it under House Load Operation because stable voltage can be generated by new Zero-Cross Detector.

  • PDF

Audio Watermarking Using Independent Component Analysis

  • Seok, Jong-Won
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.2
    • /
    • pp.175-180
    • /
    • 2012
  • This paper presents a blind watermark detection scheme for an additive watermark embedding model. The proposed estimation-correlation-based watermark detector first estimates the embedded watermark by exploiting non-Gaussian of the real-world audio signal and the mutual independence between the host-signal and the embedded watermark and then a correlation-based detector is used to determine the presence or the absence of the watermark. For watermark estimation, blind source separation (BSS) based on independent component analysis (ICA) is used. Low watermark-to-signal ratio (WSR) is one of the limitations of blind detection with the additive embedding model. The proposed detector uses two-stage processing to improve the WSR at the blind detector; the first stage removes the audio spectrum from the watermarked audio signal using linear predictive (LP) filtering and the second stage uses the resulting residue from the LP filtering stage to estimate the embedded watermark using BSS based on ICA. Simulation results show that the proposed detector performs significantly better than existing estimation-correlationbased detection schemes.

Design and Implementation of Broadband Power Detector for Six-port Direct Conversion Receiver (Six-port 직접 변환 수신을 위한 광대역 Power detector 설계 제작)

  • Lee, Yong-Ju;Kim, Yeong-Wan;Park, Dong-Cheol
    • Journal of Satellite, Information and Communications
    • /
    • v.1 no.1
    • /
    • pp.59-64
    • /
    • 2006
  • The broadband power detector for power amplitude envelope detection of the direct-conversion Six-port output signal was designed and implemented in this paper. The power detector should be linearly operated to produce the linear amplitude and phase signal for input RF signals in required broadband frequency range. The power detector should be designed under conditions of matching circuit with low VSWR, which protect unbalanced phase signal from reflection signal due to mismatch between the output port of a six-port and the input port of a power detector. The designed power detectors, which were implemented in L-band with 50 ohm matching and Ku-band with multiple LC matching circuits and isolator, respectively, were analyzed in viewpoints of the utilization as a power detector of direct conversion Six-port. The dynamic range of designed power detectors were also measured and rvaluated as a power detector of Six-port circuit.

  • PDF