• 제목/요약/키워드: side drop

검색결과 294건 처리시간 0.026초

사용후 핵연료 수송용기의 수평낙하충격에 관한 연구 (A Study on the Side Drop Impact of a Nuclear Spent Fuel Shipping Cask)

  • 정성환;이영신
    • 대한기계학회논문집A
    • /
    • 제21권3호
    • /
    • pp.457-469
    • /
    • 1997
  • A nuclear spent fuel shipping cask is required by IAEA and domestic regulations to withstand a 9m free drop condition. In this paper, the structural analysis under the 9m side drop condition was performed to understand the dynamic impact behavior and to evaluate the safety of the cask for 7 PWR nuclear spent fuel assemblies. The analysis result was compared with the measured value of the 9m side drop test for the 1/3 scaled-down model and the accuracy of the 3D analysis was confirmed. Analysis in accordance with the diameter of impact limiters for the proto-type cask were performed. Through the analysis, the impact behaviors due to the side drop and the effects dependent on the diameter of impact limiters were grasped. Maximum stress intensities on each part of the cask were respectively calculated by using the stress evaluation program and the structural safety of the cask was finally evaluated in accordance with the regulations.

An Experimental Investigation of Side-Orifice Effects on Pressure Drop for Single-Phase Flow

  • Seo, Kyong-Won;Chun, Moon-Hyun;Nam, Ho-Yun;Park, Seok-Ki;Lee, Yong-Bum
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.295-300
    • /
    • 1996
  • To investigate the effects of the side-orifice on the pressure drop for single-phase flow, a series of experiments have been carried out with 16 different downstream test sections with various combinations of side-orifice shapes, different numbers of side-orifices, and different arrangements of the side-orifice using water as a working fluid. From the measurements of the pressure drop and the flow rate, the pressure loss coefficient of the side-orifice(s) has been evaluated. Based on the total number of 529 present data, an empirical correlation for the pressure loss coefficient has been developed in terms of Reynolds number and geometric parameters, such as area ratio, equivalent diameter, leading edge, and average width of side-orifice.

  • PDF

평행류 열교환기 내부의 열유동 해석 (Heat and Flow Analysis Inside a Parallel-Flow Heat Exchanger)

  • 오석진;정길완;이관수
    • 대한기계학회논문집B
    • /
    • 제27권6호
    • /
    • pp.781-788
    • /
    • 2003
  • In the present study, the heat and flow characteristics of a parallel-flow heat exchanger are numerically analyzed by using three-dimensional turbulent modeling. Heat transfer rate and pressure drop are evaluated using the concept of the efficiency index by varying the locations, the shapes and angles of inlet/outlet, and the protrusion height of flat tube. It is found that negative angle of the inlet improves the heat transfer rate and pressure drop. Results show that the locations of the inlet and outlet should be toward the right side and the left side to the reference model, respectively, in order to enhance the heat transfer rate and pressure drop. Increasing the height of the lower header causes pressure drop to decrease and yields the good flow characteristics. The lower protrusion height of flat tube shows the improvement of the heat transfer rate and pressure drop. The heat transfer rate is greatly affected by the parameters of outlet side such as the location and angle of the outlet. However, the pressure drop is influenced by the parameters of inlet side such as the location and angle of inlet and the height of the header.

원통다관식 열교환기의 쉘측 압력 손실의 연구 (Investigation of Pressure drop on shell side of shell and tube heat exchanger)

  • 이용범;한성건;고재명
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.32-37
    • /
    • 2008
  • The present work aims to determine the overall pressure losses in the shell from the point of entry of the fluid to the outlet point of fluid of shell and tube heat exchanger. The main contribution of the present work is concerned with calculating the pressure drop in the interior section and window section. Shell-side flow velocity distributions have been evaluated. We assume that the shell-side fluid is turbulent. The calculation procedure is based upon the Delaware method. Evaluation of pressure drop on the shell side will be helpful for a designer or manufacturer of a heat exchanger.

  • PDF

편마비 환자의 족하수에 운동성 테이핑 적용이 보행능력에 미치는 영향 (Influence of Kinesio Taping of Patient with Foot Drop following CVA)

  • 정삼희;공세진;윤정규
    • 대한물리치료과학회지
    • /
    • 제7권2호
    • /
    • pp.607-613
    • /
    • 2000
  • Objective: This study is designed to examine how an application of a kinesio taping to the foot drop of a hemiplegic patient affects the functional recovery of a gait. Method: The patient was a man with left hemiplegia of about 11 months' duration. a single subject design (ABAB design) was used to investigate the timing difference at a stance phase between an unaffected side and an affected side in the gait ability of the hemiplegic patient by using the kinesio taping. The study was divided into four phase: an initial base-line, an experimental, a second base-line, and second experimental phase. Result: The timing difference at a stance phase between an unaffected side and an affected side in the gait was decreased in the case of the affected side by following the result of applying the kinesio taping to a lower extremity. Conclusion: The kinesio taping applied to the foot drop of a hemiplegic patient affects the improvement of the gait ability.

  • PDF

공기측 파울링에 의한 에어컨 열교환기의 성능분석 연구 (Performance Evaluation of Heat Exchangers due to Air-side Particulate Fouling in the Air Conditioners)

  • 안영철;조재민;이재근;이현욱;안승표;윤덕현;하삼철;강태욱
    • 설비공학논문집
    • /
    • 제15권6호
    • /
    • pp.447-453
    • /
    • 2003
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate the cooling performance and pressure drop on the air-side particulate fouling of heat exchangers for air conditioners. Air conditioners being used in the field such as inn, restaurant, and office are collected in chronological used order. Test results show 15% decrease of the cooling capacity and 44% increase of the pressure drop for the 7 years air conditioners used in the seaside inn.

평판관-루버핀 열교환기의 공기측 열전달 및 압력강하 특성에 관한 실험적 연구 (An Experimental Study on Heat Transfer and Pressure Drop of Air Side in a Plate-Louvered Fin Heat Exchanger)

  • 강병하;김석현;장혁재;박병규
    • 설비공학논문집
    • /
    • 제14권6호
    • /
    • pp.485-492
    • /
    • 2002
  • Heat transfer and pressure drop on the air side of a plate-louvered fin heat exchanger with new shape of louver fin have been investigated experimentally. Water is employed inside the flat tube to transfer heat with air for convenience. This problem is of particular interest in the design of a plate-louvered heat exchanger. The effect of air flow rate, water flow rate and water temperature on pressure drop as well as heat transfer in air side are studied in detail. The present results showed a good agreement qualitatively with the previous results in general. Based on the experimental data, f-factor and j -factor correlations of the present louvered-fin are suggested. It is also found that heat transfer could be enhanced with new shape of louver fin, compared with the conventional louvered-fin, while the f-factor remains unchanged.

슬릿휜-관 열교환기의 설계조건에서 공기측 압력강하 산출 (Evaluation of Air-side Friction Characteristics on Design Conditions of Slit Fin and Tube Heat Exchanger)

  • 조성철;김창덕;김창업;권정태;임효재
    • 에너지공학
    • /
    • 제16권3호
    • /
    • pp.149-154
    • /
    • 2007
  • 본 연구에서는 슬릿 휜-관 열교환기의 공기측 압력강하 특성을 실험적으로 고찰하였다. 물을 작동유체로 사용한 기존의 실험은 공기측 압력강하에 대해 일관된 방법을 제시하지 못하고 있다. 따라서 본 연구에서는 R22를 적용하여 휜-관 열교환기의 전표면과 습표면에 공기측의 압력강하 특성을 나타내는 표준 방법을 제시하고자 하였다. 기존의 실험 상관식과 본 연구에서 제시한 실험 데이터를 증발기와 응축기의 설계조건에서 레이놀즈수와 f-factor의 관계식으로 나타내었다. 본 실험은 공기의 속도가 $0.38{\sim}1.6\;m/s$ 일 때 냉매의 질량 유속 범위를 $150{\sim}250\;kg/m^2s$하여 수행하였다.

직관 마이크로채널 PCHE의 열전달특성 및 압력강하 (Heat Transfer Characteristics and Pressure Drop in Straight Microchannel of the Printed Circuit Heat Exchangers)

  • 김윤호;문정은;최영종;이규정
    • 대한기계학회논문집B
    • /
    • 제32권12호
    • /
    • pp.915-923
    • /
    • 2008
  • The performance experiments for a microchannel printed circuit heat exchanger (PCHE) of high-performance and high-efficiency on the two technologies of micro photo-etching and diffusion bonding were performed in this study. The microchannel PCHE were experimentally investigated for Reynolds number in ranges of 100 $\sim$ 700 under various flow conditions in the hot side and the cold side. The inlet temperatures of the hot side were conducted in range of $40^{\circ}C\;{\sim}\;50^{\circ}C$ while that of the cold-side were fixed at $20^{\circ}C$. In the flow pattern, the counter flow was provided 6.8% and 10 $\sim$ 15% higher average heat transfer rate and heat transfer performance than the parallel flow, respectively. The average heat transfer rate, heat transfer performance and pressure drop increases with increasing Reynolds number in all the experiment. The increasing of inlet temperature in the experiment range has not an effect on the heat transfer performance while the pressure drop decrease slightly with that of inlet temperature. The experimental correlations to the heat transfer coefficient and pressure drop factor as a function of the Reynolds number have been suggested for the microchannel PCHE.

Comparisons of Test-Retest Reliability of Strength Measurement of Gluteus Medius Strength between Break and Make Test in Subjects with Pelvic Drop

  • Jeon, In-Cheol
    • The Journal of Korean Physical Therapy
    • /
    • 제31권3호
    • /
    • pp.147-150
    • /
    • 2019
  • Purpose: The purpose of this study was to compare the reliability of unilateral hip abductor strength assessment in side-lying with break and make test in subjects with pelvic drop. Hip abduction muscles are very important in the hip joint structures. Therefore, it is essential to evaluate their strength in a reliable way. Methods: Twenty-five subjects participated in this study. Unilateral isometric hip abductor muscle strength was measured in side-lying, with use of a specialized tensiometer using smart KEMA system for make test, of a hand held dynamometer for break test. Coefficients of variation, and intra class correlation coefficients were calculated to determine test-retest reliability of hip abductor strength. Results: In make test, maximal hip abductor strength in the side-lying position was significantly higher compared with break test (p<0.05). Additionally, Test-retest reliability of hip abductor strength measurements in terms of coefficients of variation (3.7% for make test, 16.1% for break test) was better in the side-lying position with make test. All intraclass correlation coefficients with break test were lower than make test (0.90 for make test, 0.73 for break test). Conclusion: The side-lying body position with make test offers more reliable assessment of unilateral hip abductor strength than the same position with break test. Make test in side-lying can be recommended for reliable measurement of hip abductor strength in subjects with pelvic drop.